* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Product Presentation
Survey
Document related concepts
Electric battery wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrification wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power over Ethernet wikipedia , lookup
Audio power wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power engineering wikipedia , lookup
Buck converter wikipedia , lookup
Rechargeable battery wikipedia , lookup
Opto-isolator wikipedia , lookup
Power inverter wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Transcript
Powerware 9330 9910 - P93 p93pres.ppt rev 4.16.03 ! Developed for global market ! Incorporated proven technology previously only available at higher kVA levels ! Meets uptime and low cost of ownership requirements 1 P93 Features • Double-conversion, online technology protects against the 9 power problems • One year ProActive Service • UPS installation and start-up service included when purchase with Powerware Field Installation (IBM PN 97P3604) • Lowest cost of ownership • Complete battery care package • Compact footprint • Easy to use interface panel • Flexible communication capability Product Snapshot Power Rating: 20 kVA / 14 kW Input Voltage: 208 Vac, three-phase Output Voltage: 208/120 Vac Frequency: 50/60 Hz Input Connection: Hardwired Output Receptacles: (2) IEC-309, 3P, 4W, 60A; (3) NEMA (varies) 2 P93 Applications The P93 was specifically designed, engineered and approved for IBM applications • • • • • • • • • iSeries and AS/400 pSeries and RS/6000 xSeries and other eServers Storage and networking devices Server farms Networking Telecommunications Medical Small data centers P93 is the ideal power protection for pSeries 690 Regatta (image shown above) and the iSeries 890 (image shown on the left). 3 Applications 4 5 6 Series 9 Power Protection The P93 provides double-conversion online power protection from all 9 of the most common power problems that threaten your equipment and data Power failures High voltage spikes Power sags Frequency variations Power surges Switching transients Brownouts Harmonic distortion Line noise 7 Lowest Cost of Ownership – In normal operational mode (online, double conversion) continuous power protection with very high efficiency (>96% @ 0.7 pf and greater than 92% @ unity pf) – In Energy Optimizer Mode* - dynamically optimized performance • Stable utility power - continuous line filtering with highest efficiency • Unstable or out-of-tolerance utility power – automatically resumes online double conversion operations without operator intervention – Intelligent programmable operation allows switching between modes without operator intervention. – *>97% w/unity power factor loads There is NEVER a trade off between EFFICIENCY and AVAILABILITY 8 Highest Availability From component selection to system configuration, the P93 is designed to deliver the highest availability with premium standard features such as: • Air filters • Internal maintenance bypass Battery care Dual input Generator compatible Powerware Hot Sync redundant and capacity systems • • • • 9 Comprehensive Battery Management Package A UPS is only as good as the batteries that support it. Therefore, we rely on the best technology available to prevent unexpected battery disruption. • DC ExpertTM – Provides battery string state of health and dynamically updates battery time available when on battery or utility. • Advanced Battery Management (ABM®) – Patented charging technique that extends battery service life • Battery Circuit Test – Pulses the battery periodically to ensure the battery circuit is intact. • Temperature Compensated Charging – Optimizes the charge voltage throughout the operating temperature range. 10 Compact Footprint H Dimens ions : Height 20 kVA (mm) (in) 1132 45 Width Depth 557 22 786 31 F ootprint includes 17 minutes of battery back up time at full load and maintenance bypas s s witch D W 11 P93 Capabilities Internal features • 17 minutes of back up time for the highest kVA rating • 10% Input current THD filter (optional) • (4) Programmable building alarms • (2) Summary contacts • Integrated AS/400 interface card and 25-foot (7.62m), interface cable and serial card (for Remote Monitoring feature) • Accepts up to two optional communication cards: – Web/SNMP card (IBM Feature Code 2934) – AS/400 interface card (IBM Feature Code 2936) 12 Informative User Interface • Large LCD panel is tilted upward 15 degrees for easy viewing • Illuminated indicators for UPS status • Navigation is straightforward with the soft keys • Smart Load Off button 13 Flexible Communication Capability • Local communication – Monitor panel – Illuminated indicators (LED status) – Control panel • Remote communication – – – – – – Relay interface contacts Building alarm contacts (programmable) Summary alarm contacts RS232 ports EPO kit Remote monitor panel 14 Technical Specifications Input – 120/208 Volt, 60 Hz • 3 wire + G - Rectifier • 3 wire + G + N - Bypass – ~ 0.96 Input PF – Input Range +10% to -15% – < 10% input current THD with internally mounted filter Output – – – – 120/208 Volt, 60 Hz 0.7 Output PF ~92% Efficiency Voltage Distortion • <3% - Linear Load • <5% - Non-linear Load – Voltage Regulation • < ± 3 % with 100% unbalanced load • < ± 5 % dynamic at 100% load change • < 5 Ms recovery time to 3% of nominal 15 System Descriptions • Input – Soft start circuit charges capacitors (boost circuit) – Backfeed contactor closes and uncontrolled rectifier provides raw DC – Discharge circuit discharges capacitors in < 5 seconds when all power sources removed – Black start from battery • Boost converter/neutral regulator – Boost stage powers DC Link (Inverter primary power source) from raw DC – Boost circuit includes neutral regulator which regulates the neutral voltage, allows for 100% unbalanced loads 16 System Description • Inverter – A pulse-width-modulated IGBT inverter is powered from regulated DC Link (+/- 210 Volts) – Inverter output contactor closes to power load • Bypass – Backfeed contactor normally on – SCR switches gated to power load as required • Maintenance Bypass – A wrap-around maintenance bypass with service test position completely isolates UPS for service – Shrouded to provide safe service environment without interruption to the critical load 17 System Description Battery/Charger – 144 cells – Independent charger powered from raw DC – Isolated from power except for charge and reserve mode operation to maximize battery life (ABM) – High speed SCR/contactor switch connects battery at power failure, powering boost converter 18 Normal Mode Traditional Double Conversion Online Operation B YP AS S UT IL IT Y OUT P UT B AT T E R Y P OWE R F L OW Inverter powers load with bypass in standby – Inverter powered by utility via rectifier and boost converter – Battery in standby, (charging or resting) • Conditions: Input within specified range (typically +/- 15%) Selected preferred mode Bypass quality unacceptable 19 Energy Optimizer Mode User selectable, high efficiency parallel source operation BYPASS UTILTIY OUTPUT BATTERY POWER FLOW Bypass and inverter operate (inverter in hot-standby) – Bypass provides power (kW) and inverter stands ready to operate when and if input voltage exceeds preset range – Battery in standby, (charging or resting) • Conditions: Bypass within specified range (typical +/- 5%) Bypass quality acceptable Not on generator 20 Battery Mode BYPASS UTILITY OUTPUT BATTERY POWER FLOW Inverter powers load from battery source – Inverter powered by battery • Conditions: Utility failed or outside acceptable window 21 Bypass Mode BYPASS UTILITY OUTPUT BATTERY POWER FLOW Bypass circuit powers load – Load powered by bypass with inverter off • Conditions: UPS output overload Inverter circuit failure Temporary user-selected mode 22 Powerware Extensions Software for IBM Director • • • • • Seamless UPS and software integration into IBM Director Network Management System (NMS) Real time monitoring, management and alarm notification of all UPSs in the network: e.g. battery status, battery replacement, load level and metering information Automatically launches LanSafe and ConnectUPS Web/SNMP Card applications from within Director Available on Powerware web FREE-OF-CHARGE 23 Power Management Software Powerware Software Suite The industry’s most comprehensive software bundle, The Powerware Software Suite, is free and included with every P93. Software Wizard guides you through software selection and installation. In addition to multimedia demonstrations, product data sheets, and video clips, the Software Suite contains the following power management software: • • • LanSafe™ Network UPS shutdown and monitoring software PowerVision® (30-day trial version) UPS performance analysis and monitoring software Foreseer® (demonstration) facility and data center management software 24 Software Application Application LanSafe Single pSeries (serial/TTY) non-LPAR " Single pSeries (network) non-LPAR "* Multiple pSeries (LPAR) "* "* Single pSeries (LPAR) Multiple pSeries (non-LPAR) Powerware Extensions for NetWatch IBM Director " "* "* IBM Director Network Device * "* Co-requisite FC 2934 or 2935 ConnectUPS Web/SNMP network card. Note: UPS for iSeries applications utilize OS/400 UPS monitoring functions. 25 Software Comparison Application LanSafe NetWatch ConnectUPS Web/ SNMP Card SSL/SSH1 Security Ambient Temperature Humidity Monitoring Shutdown GUI Email/ SMTP Yes Yes Yes Yes / Yes No/No No/No - Yes - No/No No/No No/No Yes2 Yes3 Yes Yes / Yes Yes / Yes Yes / Yes4 1SSL = Secure Sockets Layer. SSH = Secure Shell. 2Via Web Browser, LanSafe or Network Management System (e.g. IBM Director, Tivoli). 3In conjunction with NetWatch software. 4With optional FC 2938 EMP (Environmental Monitoring Probe) device attached. 26 Connectivity What you need by application Software Solution zSeries iSeries LanSafe " LanSafe and ConnectUPS MultiServer card (IBM FC 2933) NetWatch and ConnectUPS Web/SNMP card (IBM FC 2934 or 2935) " pSeries xSeries " " "! LPARs ConnectUPS Relay card and AS/400 cable (IBM FC 2936) " Networking " " " " " " " " " " Powerware Extensions for IBM Director NetWatch Storage " " !Use ConnectUPS Web/SNMP/xHub card, IBM FC 2934 or 2935 to support LPAR (POWER 4 Chip Set) servers. For pSeries configurations, each LPAR needs a network connection and will install Powerware provided NetWatch or LanSafe 5 software. 27 Connectivity • Optional • FC 2933 ConnectUPS MultiServer • FC 2934 ConnectUPS Web/SNMP/xHub • FC 2936 ConnectUPS Relay & interface cable – Min: 0, Max: 2 Description IBM Part No. Feature Code Powerware Part No. Minimum # of FC Maximum # of FC ConnectUPS X-Slot Web/ SNMP/xHub Card 53P4619 2934 103002974-5501 0 2* ConnectUPS X-Slot MultiServer Card 04N7027 2933 05146447-3901 0 2* ConnectUPS X-Slot Relay Card & 25 ft. cable 97P3886 2936 103003564 0 2* *Maximum combination of optional ConnectUPS cards is two 28 ConnectUPS-X Web/SNMP/xHub Interface Card Option The Web/SNMP/xHub card is ideal for managing UPSs providing protection for network devices and gives network managers the ability to monitor and control UPS over the network via web browser, SNMP or Telnet. Features include: • Enables network administrators to remotely monitor and reset hung network devices Web/SNMP/xHub card shown • Ability to remotely control selected power outlets • Built-in three port switching hub with UPS protection • Compatible with leading SNMP network management software packages (IBM NetView, HP OpenView, SunNet Mgr, etc.). Powerware’s PowerMIB and UPS Standard MIB software included • Compatible with 100Mb and 10Mb networks • Unattended graceful shutdown of client operating systems • Automatically records UPS events and alarms • Alarm notification through email, SMNP or NetWatch client software • Monitor multiple web cards simultaneously through MultiView Software • Fast and easy firmware upgrades available at no charge • Configurable over the network via BOOTP • IBM FC 2934, IBM PN 53P4619, Powerware PN 103002974-5501 Software included with ConnectUPS Web/SNMP/xHub card: NetWatch, MultiView and PowerMIB 29 ConnectUPS-X Multi-Server Interface Card Option The Multi-Server card connectivity device that provides direct serial connection to up to five computers for unattended, graceful shutdown and power monitoring. The card operates in conjunction with LanSafe software (included with the UPS). Features include: • Real-time monitoring of critical power parameters • Graceful, unattended shutdown of multiple computers • Supports simple signaling (relay contacts) through additional DB-9 Port • IBM FC 2933, IBM PN 04N7027, Powerware PN 05146447-3901 Multi-Server card shown 30 ConnectUPS-X Relay Interface Card Option The Relay Interface card provides monitoring of UPS status through isolated, dry contact, Form-C relays. It also provides the interface for AS/400 (iSeries) computers as well as many industrial applications. Features include: • Isolated, dry contact Form-C relays for “utility failure”, “low battery”, “UPS Alarm/OK” or “on bypass” • User-selectable “normally open” or “normally closed” contacts • Remote shutdown of UPS through integrated shutdown functions • Hot-swappable - - UPS maintains power to critical applications while changing cards • 25 foot MT 9406 interface cable included • IBM FC 2936, IBM PN 97P3886, Powerware PN 103003564* *Single part number for Relay card and 25 ft. interface cable Relay card shown 31 P93 Base Configuration Overview • UPS • Connectivity – Relay card & 25 foot cable (iSeries) – Serial card and modem (ProActive service) • Input filter • Options Cabinet • 42 Pole Panel • Maintenance bypass • Output distribution housing • Output power cords* • FC 9880 • FC 9881** two (2) 60A 3 phase 4 wire IEC 309 460R9W three (3) 15A to 30A NEMA receptacles *Upon ordering, customer must stipulate length of power cord (up to 50 ft.) for FC 9880 and 9881. Power cords are supplied by installer. ** Customer must choose NEMA type for FC 9881. FC 9881 are NEMA receptacles and are not water tight connections 32 Extended Battery Cabinet (EBC) • • • • • • • Optional feature IBM Part Number: 97P2663 IBM Feature Code: 6635 Powerware Part Number: A13031 Connect up to two EBCs to extend battery runtime Line up and match battery cabinet If Base Installation purchased, installation of EBC included (concurrent to P93) 33 P93 Battery Runtimes Battery Runtime (in minutes)* Watts 7000 10500 14000 Standard (Std) +1 EBM Internal Batteries (FC 6635) 45 90 26 65 17 48 +2 EBMs (FC 6635) 155 90 75 34 Options Cabinet • Distribution housing* • Connections to output power cords for loads including eServer CPU and I/O cabinets – FC 9880 included as part of P93 base configuration (in configurator) – FC 9881 quantity and types dependent on server configuration and number of cabinets Description IBM Part No. Feature Code Powerware Part No. Minimum # of FC Maximum # of FC Output Power Cords NEMA 15A to 30A 97P2660 9881 103003673 0 6 Out Power Cords IEC 309 3P4W (460R9W) 97P2659 9880 103003672 1 1 *Must purchase P93 Installation to order output power cords. Options Cabinet Cutaway 35 UPS, Options & Battery Cabinet Front View 36 ProActive Service • Optional – Additional years of ProActive Service – – – – – 7x24 corrective maintenance coverage 7x24 annual performance check Annual power protection audit 7x24 remote monitoring advance response service Monthly UPS performance report with web access to account information and site service activity • FC 7001 • FC 7002 IBM Part No. Feature Code Powerware Part No. ProActive Concurrent 97P2657 7001 155102012-001 0 4 ProActive Non-concurrent 97P2658 7002 155102013-001 0 4 Description Minimum Maximum # of FC # of FC 37 P93 ProActive Service •Concurrent & Non concurrent •Delivered in an envelope •Min: 0, Max: 4 Envelope & labeling Document inside of envelope38 P93 Base Installation • Description delivered in an envelope • Installation on site by contractor • Min: 1, Max: 1 Text: Field Installation of one 9330-20 20kVA UPS (A21201110133113) 208V input with standard internal batteries and/or options cabinet with Output Distribution Housing (A3BBAS0MR3) for bypass and 42 circuit load panel within the 50 United States. All installations performed using locally licensed and insured contractors. Installed as per NEC, State, Local codes and manufacturer's guidelines. Installation is warranted for five years by installation vendor. Installation includes: move UPS and Options Cabinet from customer's loading dock or ground level to installation area using customer provided freight elevator if different floor and/or level, uncrate, set-inplace and dispose of packaging materials. Run AC input feeder a maximum of 150 feet from existing building service to UPS. Include feeder breaker and supplemental ground. Installation performed during normal business hours (Monday - Friday) 8AM to 5PM. Adequate space must be available to complete installation. Document inside of envelope 39 P93 Install Package A • Description delivered in an envelope • Installation on site by contractor • Min: 1, Max: 1 Document inside of envelope 40 P93 Install Package B • Description delivered in an envelope • Installation on site by contractor • Min: 0, Max: 6 Document inside of envelope 41 P93 Site Evaluation • Powerware site evaluation is available five days a week during normal business hours (5x8) prior to installation. • During the evaluation, the Powerware Power Consultant will: – Work with IBM IPR to determine output connection requirements – Contact customer to discuss UPS installation and output configuration. If only new IBM supplied equipment will be connected to the UPS, a site visit will not be required. – Provide site visit report to IBM. 42 Scope of Work Tasks to be performed by the IBM Installation Planning Representative (IPR) once the configuration and customer contact information is supplied: 1. Run a power profile on the configuration. Identify the type and quantity of line cords and the maximum power consumption. 2. Review the 9910-P93 configuration. Key features on the order are: a. #9880 – Specifies quantity two (2) 60 A, 3 phase, 4 wire receptacles. b. #9881 – Specifies quantity three (3) 15 A to 30 A NEMA non or locking receptacles. 3. Work with the customer to determine if there is any other equipment he /she wants to protect with the UPS. A site visit is recommended, whether is it by the IPR or an IPR designee, but a phone call or other means of contact is acceptable. 4. Determine if there are any 9910-P93 limitations in receptacles or capacity that need to be immediately addressed. Important UPS items to know: a. Besides the 20kVA / 14 kWatts maximum output, the amount of imbalance on any one phase cannot exceed 1/3 of the total UPS capacity. c. Voltage input and output is 208 Vac line-to-line. d. The Options Cabinet that is always part of the base 9910-P93 configuration contains a maintenance bypass and 42 pole circuit breaker panel. 5. Provide a summary report to key contacts in IBM and Powerware. 43 Options Cabinet Cutaway Install Install Package Package A A and/or and/or B. B. Output Output power power cord cord up up to to 50’ 50’ length. length. Rated Rated for for raised raised floor. floor. 44 UPS Cabinet Rear View P93 P93 X-Slots: X-Slots: #1 #1 Populated Populated with with Serial Serial Card Card and and Modem Modem #2 #2 Populated Populated with with Relay Relay Card Card #3 #3 & & #4 #4 unpopulated unpopulated 45 P93 Collateral • Additional information available at www.oem.powerware.com/ibm-ups – Select your region. Click “Products”, click “9910 Solutions” then click “Powerware pSeries” or “Powerware iSeries” • Materials available – – – – Data sheet Application overview chart Product presentation Documents (Installation and Operation Manual, IBM Applications Installation Guide) 46