* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download MODEL: M6DVS
Linear time-invariant theory wikipedia , lookup
Stray voltage wikipedia , lookup
History of electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Phone connector (audio) wikipedia , lookup
Control system wikipedia , lookup
Current source wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Audio power wikipedia , lookup
Power engineering wikipedia , lookup
Power inverter wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Voltage optimisation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Integrating ADC wikipedia , lookup
Mains electricity wikipedia , lookup
Voltage regulator wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Distribution management system wikipedia , lookup
Two-port network wikipedia , lookup
Alternating current wikipedia , lookup
Buck converter wikipedia , lookup
Power electronics wikipedia , lookup
Schmitt trigger wikipedia , lookup
MODEL: M6DVS Euro Terminal Ultra-Slim Signal Conditioners M6D Series SIGNAL TRANSMITTER Functions & Features • 5.9-mm wide ultra-slim design • Low profile allows the M6D module mounted in a 120-mm deep panel • Galvanically isolates process instrumentation signals • High-density mounting • Power indicator LED • UL approval 5.9 (.23) 94 (3.70) 5W: -5 – +5 V DC (Input resistance 1 MΩ min.) 0: Specify voltage (See INPUT SPECIFICATIONS) [2] OUTPUT Current A: 4 – 20 mA DC (Load resistance 550 Ω max.) D: 0 – 20 mA DC (Load resistance 550 Ω max.) G: 0 – 1 mA DC (Load resistance 11 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 3: 0 – 1 V DC (Load resistance 1000 Ω min.) 4: 0 – 10 V DC (Load resistance 10 kΩ min.) 5: 0 – 5 V DC (Load resistance 5000 Ω min.) 6: 1 – 5 V DC (Load resistance 5000 Ω min.) 4W: -10 – +10 V DC (Load resistance 20 kΩ min.) 5W: -5 – +5 V DC (Load resistance 10 kΩ min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) [3] POWER INPUT MODEL: M6DVS-[1][2]-[3][4] AC Power M2: 100 – 240 V AC (Operational voltage range 90 – 264 V, 47 – 66 Hz) (UL not available) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) ORDERING INFORMATION [4] OPTIONS (multiple selections) • Code number: M6DVS-[1][2]-[3][4] Specify a code from below for each [1] through [4]. (e.g. M6DVS-4W4W-R/K/UL) • Special input and output ranges (For codes Z & 0) RESPONSE TIME (0 – 90 %) blank: Standard (≤ 0.5 sec.) /K: Fast Response (Approx. 3.5 msec. voltage output; Approx. 25 msec. current output) STANDARDS & APPROVALS blank: CE marking /UL: UL approval (CE marking) 102 (4.02) mm (inch) [1] INPUT Current A: 4 – 20 mA DC (Input resistance 50 Ω) B: 2 – 10 mA DC (Input resistance 100 Ω) C: 1 – 5 mA DC (Input resistance 200 Ω) D: 0 – 20 mA DC (Input resistance 50 Ω) E: 0 – 16 mA DC (Input resistance 50 Ω) F: 0 – 10 mA DC (Input resistance 100 Ω) G: 0 – 1 mA DC (Input resistance 1000 Ω) H: 10 – 50 mA DC (Input resistance 20 Ω) Z: Specify current (See INPUT SPECIFICATIONS) Voltage 3: 0 – 1 V DC (Input resistance 1 MΩ min.) 4: 0 – 10 V DC (Input resistance 1 MΩ min.) 5: 0 – 5 V DC (Input resistance 1 MΩ min.) 6: 1 – 5 V DC (Input resistance 1 MΩ min.) 4W: -10 – +10 V DC (Input resistance 1 MΩ min.) SENTRONIC AG Produkte, Support und Service GENERAL SPECIFICATIONS Connection Input and output: Euro terminal (torque 0.3 N·m) Power input: Via the Installation Base (model: M6DBS) (not available for AC power input) or Euro terminal (torque 0.3 N·m) Applicable wire size: 0.2 to 2.5 mm2 Housing material: Flame-resistant resin (black) Isolation: Input to output to power Zero adjustment: -2 to +2% (front) (Output code 4W, 5W: Adjustable at 0V. No output below 0mA for the code D.) Span adjustment: 98 to 102 % (front) Power LED: Green light turns on when the power is supplied. Rugghölzli 2 CH - 5453 Busslingen Tel. +41 (0)56 222 38 18 Fax +41 (0)56 222 10 12 [email protected] www.sentronic.com MODEL: M6DVS INPUT SPECIFICATIONS • DC Current: Input resistor incorporated Specify input resistance value for code Z. (R ≤ 0.125 W ÷ [F.S. Current]2) • DC Voltage: -30 – +30 V DC Minimum span: 100 mV Offset: Max. 1.5 times span Input resistance: 1 MΩ min. (10 kΩ min. with no power supplied) UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D hazardous locations (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 61010-1, CAN/CSA-C22.2 No.61010-1) OUTPUT SPECIFICATIONS • DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 11 V max. • DC Voltage: 0 – 10 V DC Minimum span: 1 V Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 1 V INSTALLATION Power Consumption •AC Power input: Max. 2 VA •DC Power input: Approx. 0.5 W Operating temperature: -20 to +55°C (-4 to +131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Installation Base (model: M6DBS) or DIN rail Weight: 60 g (2.1 oz) PERFORMANCE in percentage of span Accuracy: ±0.1 % Temp. coefficient: ±0.01 %/°C (±0.006 %/°F) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EN 61000-6-4 (EMI) EN 61000-6-2 (EMS) Low Voltage Directive (2006/95/EC) EN 61010-1 Installation Category II Pollution Degree 2 Max. operating voltage 300 V Input or output to power: Reinforced insulation Input to output: Basic insulation Approval: SENTRONIC AG Produkte, Support und Service Rugghölzli 2 CH - 5453 Busslingen Tel. +41 (0)56 222 38 18 Fax +41 (0)56 222 10 12 [email protected] www.sentronic.com MODEL: M6DVS EXTERNAL VIEW (With the cover open) Power LED Zero Adj. Span Adj. DIMENSIONS unit: mm (inch) WIRE INSERTION ANGLE: approx. 7° 8–M3 EURO TERMINAL 5 6 7 8 DIN RAIL HOOK 94 (3.70) DIN RAIL 35mm wide 1 5.9 (.23) 2 3 4 SCREWDRIVER INSERTION ANGLE : approx. 40° [0.5 (.02)] 102 (4.02) • When mounting, no extra space is needed between units. SENTRONIC AG Produkte, Support und Service Rugghölzli 2 CH - 5453 Busslingen Tel. +41 (0)56 222 38 18 Fax +41 (0)56 222 10 12 [email protected] www.sentronic.com MODEL: M6DVS SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Z Isolation + 1 INPUT * Low Drift Amplifier S Output Driver – 2 5 + OUTPUT 6 – POWER LED 3 7 U(+) POWER 4 CONNECTOR 8 V(–) POWER** *Input shunt resistor incorporated for current input. **Available only for DC power input type Specifications are subject to change without notice. SENTRONIC AG Produkte, Support und Service Rugghölzli 2 CH - 5453 Busslingen Tel. +41 (0)56 222 38 18 Fax +41 (0)56 222 10 12 [email protected] www.sentronic.com M6DVS INSTRUCTION MANUAL SIGNAL TRANSMITTER BEFORE USE .... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System’s Sales Office or representatives. ■ PACKAGE INCLUDES: Signal conditioner.......................................................... (1) ■ MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. ■ INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. MODEL M6DVS ■ WIRING •Do not install cables (power supply, input and output) close to noise sources (relay drive cable, high frequency line, etc.). •Do not bind these cables together with those in which noises are present. Do not install them in the same duct. •Install lighting surge protectors for those wires connected to remote location. ■ AND .... The unit is designed to function as soon as power is supplied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet. COMPONENT IDENTIFICATION Body POINTS OF CAUTION ■ CONFORMITY WITH EC DIRECTIVES •This equipment is suitable for use in a Pollution Degree 2 environment and in Installation Category II, with the maximum voltage of 300V. Basic insulation is maintained between signal input and output. Prior to installation, check that the insulation class of this unit satisfies the system requirements. •The equipment must be mounted inside a panel. •Altitude up to 2000 meters •The actual installation environments such as panel configurations, connected devices, connected wires, may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conformity. Front Cover Spec. Marking DIN Rail Adaptor ■ FRONT PANEL CONFIGURATION (with the cover open) Power LED Zero Adj. Span Adj. ■ POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below: 100 – 240V AC rating: 90 – 264V, 47 – 66 Hz, max. 2VA 24V DC rating: 24V ±10%, approx. 0.5W ■ GENERAL PRECAUTIONS Before you remove the unit or mount it, turn off the power supply and input signal for safety. ■ ENVIRONMENT •Indoor use •When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. •Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. •Environmental temperature must be within -20 to +55°C (-4 to +131°F) with relative humidity within 30 to 90% RH in order to ensure adequate life span and operation. EM-7822 Rev.4 SENTRONIC AG Produkte, Support und Service Rugghölzli 2 CH - 5453 Busslingen Tel. +41 (0)56 222 38 18 Fax +41 (0)56 222 10 12 P. / 3 [email protected] www.sentronic.com M6DVS INSTALLATION Set the unit so that its DIN rail adapter is at the bottom. When the unit is installed to an Installation Base (model M6DBS), refer to its instruction manual. ■ MOUNTING THE UNIT ON A DIN RAIL A)Hang the upper hook at the rear side of unit on the DIN rail. B)Push in the lower in keeping pressing the unit to the DIN rail. ■ REMOVING THE UNIT A)Pull down the DIN rail adaptor using a minus screwdriver. B)Pull out the lower part of the unit. C)Remove the upper part from the DIN rail. C B A B DIN Rail DIN Rail Adaptor A TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit. ■ EXTERNAL DIMENSIONS unit: mm (inch) WIRE INSERTION ANGLE: approx. 7° 8–M3 EURO TERMINAL 5 6 7 8 DIN RAIL HOOK 94 (3.70) DIN RAIL 35mm wide 1 2 3 4 SCREWDRIVER INSERTION ANGLE : approx. 40° 5.9 (.23) [0.5 (.02)] 102 (4.02) • When mounting, no extra space is needed between units. ■ CONNECTION DIAGRAM + 1 5 + – 2 6 – OUTPUT INPUT 7 U (+) POWER CONNECTOR 8 V (–) POWER* *Available only for DC power input type EM-7822 Rev.4 SENTRONIC AG Produkte, Support und Service Rugghölzli 2 CH - 5453 Busslingen Tel. +41 (0)56 222 38 18 Fax +41 (0)56 222 10 12 P. / 3 [email protected] www.sentronic.com M6DVS Wire exposure 8 mm Recommended ferruled wire 3.7 mm dia. max. 3.7 mm dia. max. ■ WIRING INSTRUCTIONS • Applicable wire size Solid: 0.2 to 2.5 mm2 (0.55 to 1.75 dia.) Stranded: 0.2 to 2.5 mm2 (Tinning wire ends may cause contact failure and therefore is not recommended.) Ferruled: 0.2 to 1.5 mm2 (0.55 to 1.35 dia.) • Expose wire conductors by 8 mm (0.31”). 1) Terminal wiring: Check that all cables are correctly connected according to the connection diagram. 2) Power input voltage: Check voltage across the terminal 7 – 8 with a multimeter. 3) Input: Check that the input signal is within 0 – 100% of the full-scale. 4) Output: Check that the load resistance meets the described specifications. ADJUSTMENT PROCEDURE This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do not need any calibration. For matching the signal to a receiving instrument or in case of regular calibration, adjust the output as explained in the following. 8 mm How to Connect Wires Wire CHECKING Screwdriver ■ HOW TO CALIBRATE THE OUTPUT SIGNAL Use a signal source and measuring instruments of sufficient accuracy level. Turn the power supply on and warm up for more than 10 minutes. 1) ZERO: Apply 0% input and adjust output to 0%. For a bidirectional output (e.g. -5 – +5V DC), apply an input signal corresponding to 0V DC output. (Same procedure in (3)) 2) SPAN: Apply 100% input and adjust output to 100%. 3) Check ZERO adjustment again with 0% input. 4) When ZERO value is changed, repeat the above procedure 1) – 3). Insert a wire. Confirm that the wire tip hits the bottom and tighten the screw with a screwdriver. Confirm that the wire’s insulation tube is not caught in the terminal. Screwdriver 8 mm 6 m m Wire MAINTENANCE Regular calibration procedure is explained below: ■ CALIBRATION Warm up the unit for at least 10 minutes. Apply 0%, 25%, 50%, 75% and 100% input signal. Check that the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the “ADJUSTMENT PROCEDURE” explained earlier. M-SYSTEM WARRANTY M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice. THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER. M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected] EM-7822 Rev.4 SENTRONIC AG Produkte, Support und Service Rugghölzli 2 CH - 5453 Busslingen Tel. +41 (0)56 222 38 18 Fax +41 (0)56 222 10 12 P. / 3 [email protected] www.sentronic.com