* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ILUMEN PID SOLUTION
Survey
Document related concepts
Pulse-width modulation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrical substation wikipedia , lookup
Stray voltage wikipedia , lookup
Opto-isolator wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Voltage optimisation wikipedia , lookup
Resilient control systems wikipedia , lookup
Alternating current wikipedia , lookup
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Distributed control system wikipedia , lookup
Power inverter wikipedia , lookup
Distribution management system wikipedia , lookup
Mains electricity wikipedia , lookup
Control theory wikipedia , lookup
Control system wikipedia , lookup
Transcript
ILUMEN PID SOLUTION ILUMEN PID BOX & ILUMEN PID CONTROL BOX What is PID? PID or Potential Induced Degradation is a problem that occurs on many photovoltaic panels when they are exposed to a negative voltage to ground. The Ilumen PID solution can regenerate panels affected with PID and prevent PID from happening. This without affecting the inverter and any loss of yield. The 100% solution is easy to implement and compatible with all inverters and string sizes, it’s the ideal solution for medium and large scale projects. The Ilumen PID Control Box has integrated GPRS communication (to www.myilumen.be) so we can control the solution without going on site. 20% Compatible with all inverters and string sizes Easy to implement The best solution for large scale systems Regenerates panels affected with PID 2yr Common yield loss as result of PID problem 4yr Switch example monostring Switch example multistring Technical data ILUMEN PID BOX & ILUMEN PID CONTROL BOX PV array / inverter input Maximum PV voltage Output voltage to ground Maximum PV current Maximum output current in operation 1000 V Up to 1250 V 34 A 100 mA GRID (AC) Nominal AC voltage Nominal AC grid frequency Power consumption in standby operation Typical power consumption in operation Maximum power consumption 110 to 240 V 50 to 60 Hz < 0.2 W 2 W per PID BOX 600 W General data Dimensions PID BOX (∅ / H) Dimensions PID CONTROL BOX (W x D x H) Weight Operating temperature range Environmental conditions PID BOX Environmental conditions PID CONTROL BOX PID BOX PV connectors 130 / 25 mm 255 x 210 x 315 mm 200 g -25 to 60 °C (-13 to 140 °F) IP65 - indoor and outdoor use IP44 - indoor use only MC4 (optional SUNCLIX) Configuration One ILUMEN PID CONTROL BOX per project Maximum one MPPT per PID BOX Number of PID BOXes per PID CONTROLLER Up to 100 (more on request) Communication On board GPRS Various Warranty Certificates Registration before use Up to 20 years www.ilumen.be www.myilumen.be www.ilumen.be To measure is to know Ilumen