Download PowerRite® Pro UPS
Survey
Document related concepts
Three-phase electric power wikipedia , lookup
Electric power system wikipedia , lookup
Power inverter wikipedia , lookup
Electrical substation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Stray voltage wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power engineering wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Alternating current wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electric battery wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Transcript
PowerRite® Pro UPS G N I N IN RO W RD ITE® P A W A ERR POW Features ◆ Advanced Battery Management (ABM™) doubles battery life ◆ Buck/Boost Voltage Regulation ◆ Compatible with LanSafe III and FailSafe III Power Management Software ◆ SNMP capabilities via PowerLink Adapter ◆ Exclusive 10-Year Pro-Rated Warranty (including two years full coverage) and $25,000 computer protection guarantee ◆ Rack-mount and international versions available ◆ Compliance with international safety, performance and environmental standards Uninterruptible Power Systems for LANs, Fileservers, PCs, Workstations & other Sensitive Electronic Equipment I n a continuing effort to supply power protection for LANs, fileservers, PCs, workstations, and other sensitive electronic equipment, Deltec presents its award winning line of PowerRite® Pro UPSs. Selected over 29 UPSs, the PowerRite Pro was PC Magazine Editors’ Choice for the lowest priced, best quality backup power system that delivers full power protection. These systems are available in 120, 208, and 230 volt models with pure sinewave output from 400 to 3000 VA. D eltec’s PowerRite Pro series features advanced protection from power outages, brownoutss, surges, and line noise. Because of its unique approach to extending UPS battery life, the PowerRite Pro came to life bearing three international patents along with the industry’s longest warranty. The PowerRite Pro incorporates Deltec’s microprocessor-based Advanced Battery Management (ABM™) technology that doubles battery life, speeds recharge time, and provides early notification of battery service requirements. The ABM feature includes a proven automatic battery check that assures UPS reliability. 2727 Kurtz Street ◆ San Diego, California 92110 ◆ F or ultimate computer grade power the PowerRite Pro also features Deltec’s exclusive Buck/Boost Voltage Regulation. In addition, easy to read front panel status indicators and audible alarms compliment intelligent communications capabilities. The PowerRite Pro also takes full advantage of Deltec’s LanSafe III and FailSafe III Power Management Software for all popular platforms and provides SNMP capabilities via Deltec’s PowerLink SNMP Adapter. Rack-mount and international versions are also available. T he PowerRite Pro meets or exceeds international standards for excellence, performance, and safety. Created by an International design team, backed by Deltec’s exclusive Triple Power Warranty, bearing full agency approvals, and manufactured to ISO 9000 quality standards, the PowerRite Pro series provides the highest level of design and performance to keep your critical applications running without interruption. Deltec is an ISO 9000 certified company, meaning, we meet the highest manufacturing, design and customer service standards. 1-800-DELTEC-1 ◆ 619/291-4211 ◆ FAX 619/296-8039 PowerRite Pro Technical Specifications Front Panel Display INPUT Power On Input Level Battery Level Load Level Comm Port Battery Service Site Wiring Fault Alarm Silence Exclusive Triple Power Warranty ◆ $25,000 Load Protection Guarantee Resettable circuit breaker and battery fuse On Line Efficiency ›96% On Line Regulation -10%, +6%; surpasses CBEMA recommendation; low-line boost and high-line buck control to provide finer output regulation without depleting batteries te an ar Gu on ra Lo ad ar W $2 5,0 00 nty (Minutes and seconds) UPS w/ABM™ UPS w/Trickle Charge 12:00 9:00 6:00 24 30 36 42 48 54 Battery Age (in months) Data based upon tests performed in 1993 by an independent battery manufacturer. 60 66 72 Noise Filtering MOVs and line filter for normal and common mode noise Electro Static Susceptibility Receptacles >15 KV Standard NEMA receptacles or IEC-320 female plugs; British Standard and Schuko plugs available. See Owner’s Manual for details INDICATORS AND CONTROLS OUTPUT On Battery VAC Regulation ±5%; Sinusoidal wave On Battery Freq Regulation ±0.5% Battery Advanced charging for faster recovery; 3 to 6 hours North American units — 6-foot line cord with appropriate NEMA plug; International units — IEC 10 A Inlet Coupler Protection d Pr te Battery Backup Time Connections 60-Day Money Back Guarantee 15:00 12 18 50/60 Hz; ±5% ◆ The lead-acid batteries typically used in a UPS are considered viable as long as they can maintain backup times of at least half that of new batteries. The illustration below shows that batteries which are constantly trickle charged (as are virtually all other UPSs on the market today) reach the end of their useful life in less than half the time of batteries charged using Advanced Battery Management (ABM™). Our ABM uses a patented three-stage charging technique that not only doubles battery life, but also speeds battery recharge time and provides up to a 60-day advanced notification of pending battery failure. 6 Nominal Input Frequency 400-3000 VA; see Model Selection Guide Patented Advanced Battery Management (ABM™) Technology Doubles Battery Life 0 ±20% standard; also selectable for ±25% Power Levels e Ra cti o- ote r rP te e uaran er Sati sfaction G On Line Voltage Range 10-Year Pro-Rated Warranty ea -Y Cust om 120, 208, or 230 VAC nominal; see Model Selection Guide for user selectable voltages ◆ 10 TRIPLE POWER WARRANTY Voltage Battery Charging Sealed, maintenance-free, lead-acid Battery Monitoring Advanced monitoring for earlier failure detection and warning Backup Time 5 to 10 minutes at full load; 10 to 30 minutes and more with typical partial load, depending on model; see Estimated Backup Times table Serial Communication Intelligent serial communication to provide alarms with history, measured parameters, self-test, and many other features Front Panel Interface Ergonomic indicators including Wiring Fault, Battery Service, Communication Operation, System Normal; bar graphs for Input Level, Battery Charge Level, % Load Contact Closures Input failure, Low battery ON/OFF Control Local and remote PHYSICAL Dimensions and Weight See Model Selection Guide Audible Noise Less than 45 dB, most models Operating Temp 0°C - 40°C (32°F - 104°F) Operating Humidity 0 to 95% non-condensing Operating Altitude Up to 10,000 feet above sea level Conformance Standards CE, IEEE 446, NEMA PE 1, ANSI C62.41, FCC Class A & B, CISPR, NSTA and others Safety Standards UL 1778, CSA C22.2, and VDE PowerLink II SNMP Adapter In addition to the comprehensive network power management available with LanSafe III software, Deltec’s optional PowerLink II SNMP Adapter adds control and monitoring capabilities for nonintelligent devices in SNMP-based networks. Working in concert with Deltec’s LanSafe III, PowerLink II is a standard MIB II compliant 10Base-T and 10Base-2 adapter, ideal for management of hubs, routers, and other non-intelligent devices. The compact device can be mounted conveniently on the rear or side panel of the UPS or any other suitable location. Buck/Boost Voltage Regulation Deltec’s exclusive Buck/Boost Voltage Regulation ensures consistent input voltage to your critical load. If the input voltage is too high, the PowerRite Pro Bucks the voltage instantaneously (demonstrated in the illustration below) or Boosts the voltage if it is too low. Deltec’s PowerRite Pro has the widest input voltage window and tightest output regulation available which corrects input voltage variations as large as ±25% without depleting the battery. It is the only UPS in its class to meet Computer & Business Equipment Manufacturers Association (CBEMA) voltage recommendations. Power Management Software Compatibility The PowerRite Pro UPSs are compatible with Deltec’s LanSafe III and FailSafe III Power Management Software. Together they ensure maximum data integrity for computer users by providing flexible, reliable, and comprehensive control of UPSs in networked or standalone applications. Via an RS-232 port on the rear panel of the UPS, LanSafe III gives network administrators automatic orderly shutdown of all network devices — including multiple servers and workstations during extended power failures. Indicates use of Buck/Boost voltage regulation with Deltec’s proprietary control circuitry Utility power input voltage Remaining run time while on battery Load capacity to evaluate UPS utilization Shows Deltec’s Advanced Battery Management (ABM)TM in action — preserving the life of your battery Output voltage to the computer Features ◆ ◆ ◆ ◆ PowerRite Pro Rack-Mount and Trim-Rack ◆ PowerRite Pro Rack-Mount UPSs offer ideal backup for rack-based computer systems, servers, routers, hubs, multiplexers, and other sensitive electrical equipment. Rack-Mount and Trim-Rack units incorporate all the advanced technology of the standard PowerRite Pro and are designed to fit in standard 19-inch equipment racks. These UPSs are available in 120, 208, and 230 volt models with power ratings from 600 to 3000 VA. Both the Rack-Mount and the Trim-Rack are compatible with LanSafe III and FailSafe III power monitoring software and both work with Deltec’s PowerLink SNMP Adapter. ◆ ◆ ◆ ◆ Exclusive SafetyNetTM Sequential Shutdown of all network devices Work in progress is saved throughout the network Remote control, testing and monitoring for all UPSs on the network Paging and e-mail notification in the event of a power failure Customizable alerts with personalized message text and user list Supports up to 64 network devices with a single UPS Multiple network device support with a single UPS Comprehensive power status data displays Supports other manufacturers’ UPSs Operating Systems ◆ ◆ The photograph to the left shows the PowerRite Pro Trim-Rack mounted in a standard equipment rack. The Trim-Rack also features Hot Swappable batteries. FailSafe III Stand-alone Solutions Windows 95, OS/2, Windows 3.x, and Windows NT LanSafe III Network Solutions Windows 95, OS/2, UNIX, Novell NetWare, MS DOS, Windows 3.x, Windows NT, and Macintosh TM for OS/2 for IBM LAN Model Selection Guide Model Nominal Input Number Frequency (Hz)1 North American Models PRA400 50/60 PRA600 50/60 PRA1000 50/60 PRA1500 50/60 PRA20002 50/60 2 PRA2200 50/60 PRA30002 50/60 2 PRA2200b 50/60 PRA2200b L62 50/60 2 PRA3000b 50/60 International Models PRA400i 50/60 PRA600i 50/60 PRA1000i 50/60 PRA1400i 50/60 2 PRA1800i 50/60 PRA2200i2 50/60 2 PRA3000i 50/60 Battery Box — Power Out (VA) Input/Output Voltage (VAC) Nominal Output Current (Amp) Dimensions WxHxD (Inches/cm) Weight (lb/kg) 400 600 1000 1440 1920 2200 3000 2200 2200 3000 110/120/127 110/120/127 110/120/127 110/120/127 110/120/127 110/120/127 110/120/127 199/208/217 199/208/217 199/208/217 3.3 5.0 8.3 12.0 16.0 18.3 25.0 10.6 10.6 14.4 4.5x6.5x15.7/11x17x40 4.5x6.5x15.7/11x17x40 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 25/11.3 25/11.3 53/24 53/24 31/14.1 32.1/14.6 42/19.1 32.1/14.6 32.1/14.6 42/19.1 400 600 1000 1400 1800 2200 3000 48 V 220/230/240 220/230/240 220/230/240 220/230/240 220/230/240 220/230/240 220/230/240 — 1.7 2.6 4.3 6.1 7.8 9.6 13.0 — 4.5x6.5x15.7/11x17x40 4.5x6.5x15.7/11x17x40 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 7x9x16.7/18x23x42 25/11.3 25/11.3 53/24 53/24 31/14.1 32.1/14.6 42/19.1 65/29.5 1. 120 and 127 V operation for 60 Hz only. All other voltages for 50 and 60 Hz. 2. Uses PRA Battery Box. See Battery Box row for dimensions & weight. Estimated Backup Times (in minutes) PowerRite Pro Applications External Hard Drive 80x86 or 680x0 PC, Hub Intelligent Terminal, POS 80x86/680x0 PC w/Monitor Pentium or Power PC Router or Tape Drive Workstation w/16" Monitor Workstation w/19" Monitor File Server w/Monitor RISC Workstation Super Workstations Small Tower Mini Telecom Equipment (high-end) Multiple Workstations Midrange Systems Multiple Servers Load 100 VA 250 VA 300 VA 350 VA 400 VA 450 VA 500 VA 600 VA 800 VA 1000 VA 1200 VA 1400 VA 1800 VA 2200 VA 2500 VA 3000 VA PRA400 57 18 14 10 6 PRA600 95 33 24 19 15 13 11 6 PRA1000 155 55 40 36 30 27 23 19 12 8 PRA1500 235 90 59 52 43 39 35 29 20 13 10 7 PRA2000 395 255 205 180 140 125 100 75 53 33 26 22 14 PRA2200 395 255 205 180 140 125 100 75 53 33 26 22 14 10 PRA3000 395 255 205 180 140 125 100 75 53 33 26 22 14 10 8 7 This guide provides typical application information. Battery times are approximate and may vary with equipment, configuration, disk access, battery age, temperature, etc. Call today for more information. Innovators in Power Protection 2727 Kurtz Street ◆ San Diego, California 92110 ◆ USA 1-800-DELTEC-1 ◆ 619/291-4211 ◆ FAX 619/296-8039 e-mail: [email protected] www: http://www.deltecpower.com Windows is a registered trademark of Microsoft Corporation. OS/2 is a registered trademark of International Business Machine Corporation. Novell and NetWare are registered trademarks of Novell, Inc. Other brand or product names are trademarks or registered trademarks of their respective holders. Due to continuing product improvement programs, specifications are subject to change without notice. © Deltec Electronics Corporation 1996, my6/60-560