Download PowerRite® Pro UPS

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Three-phase electric power wikipedia , lookup

Electric power system wikipedia , lookup

Islanding wikipedia , lookup

Power inverter wikipedia , lookup

Electrical substation wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Stray voltage wikipedia , lookup

Rectifier wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power engineering wikipedia , lookup

Opto-isolator wikipedia , lookup

Buck converter wikipedia , lookup

Metadyne wikipedia , lookup

Alternating current wikipedia , lookup

Power electronics wikipedia , lookup

Voltage optimisation wikipedia , lookup

Electric battery wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Uninterruptible power supply wikipedia , lookup

Transcript
PowerRite® Pro UPS
G
N
I
N
IN RO
W
RD ITE® P
A
W
A ERR
POW
Features
◆
Advanced Battery Management
(ABM™) doubles battery life
◆
Buck/Boost Voltage Regulation
◆
Compatible with LanSafe III and
FailSafe III Power Management
Software
◆
SNMP capabilities via PowerLink
Adapter
◆
Exclusive 10-Year Pro-Rated
Warranty (including two years
full coverage) and $25,000
computer protection guarantee
◆
Rack-mount and international
versions available
◆
Compliance with international
safety, performance and
environmental standards
Uninterruptible Power Systems for LANs, Fileservers, PCs,
Workstations & other Sensitive Electronic Equipment
I
n a continuing effort to supply power
protection for LANs, fileservers, PCs,
workstations, and other sensitive electronic equipment, Deltec presents its
award winning line of PowerRite® Pro
UPSs. Selected over 29 UPSs, the
PowerRite Pro was PC Magazine Editors’
Choice for the lowest priced, best quality backup power system that delivers
full power protection. These systems are
available in 120, 208, and 230 volt models with pure sinewave output from 400
to 3000 VA.
D
eltec’s PowerRite Pro series features
advanced protection from power
outages, brownoutss, surges, and line
noise. Because of its unique approach
to extending UPS battery life, the
PowerRite Pro came to life bearing three
international patents along with the
industry’s longest warranty. The
PowerRite Pro incorporates Deltec’s
microprocessor-based Advanced Battery Management (ABM™) technology
that doubles battery life, speeds recharge
time, and provides early notification of
battery service requirements. The ABM
feature includes a proven automatic battery check that assures UPS reliability.
2727 Kurtz Street
◆
San Diego, California 92110
◆
F
or ultimate computer grade power
the PowerRite Pro also features
Deltec’s exclusive Buck/Boost Voltage
Regulation. In addition, easy to read
front panel status indicators and audible
alarms compliment intelligent communications capabilities. The PowerRite
Pro also takes full advantage of Deltec’s
LanSafe III and FailSafe III Power Management Software for all popular platforms and provides SNMP capabilities
via Deltec’s PowerLink SNMP Adapter.
Rack-mount and international versions
are also available.
T
he PowerRite Pro meets or exceeds
international standards for excellence, performance, and safety. Created
by an International design team, backed
by Deltec’s exclusive Triple Power Warranty, bearing full agency approvals, and
manufactured to ISO 9000 quality standards, the PowerRite Pro series provides
the highest level of design and performance to keep your critical applications
running without interruption.
Deltec is an ISO 9000 certified company,
meaning, we meet the highest
manufacturing, design and customer
service standards.
1-800-DELTEC-1 ◆ 619/291-4211
◆
FAX 619/296-8039
PowerRite Pro Technical Specifications
Front Panel Display
INPUT
Power On
Input Level
Battery Level
Load Level
Comm Port
Battery Service
Site Wiring Fault
Alarm Silence
Exclusive Triple Power Warranty
◆
$25,000 Load Protection
Guarantee
Resettable circuit breaker and
battery fuse
On Line Efficiency
›96%
On Line Regulation
-10%, +6%; surpasses CBEMA
recommendation; low-line boost
and high-line buck control to
provide finer output regulation
without depleting batteries
te
an
ar
Gu
on
ra
Lo
ad
ar
W
$2
5,0
00
nty
(Minutes and seconds)
UPS w/ABM™
UPS w/Trickle
Charge
12:00
9:00
6:00
24
30
36
42
48
54
Battery Age
(in months)
Data based upon tests performed in
1993 by an independent battery manufacturer.
60
66
72
Noise Filtering
MOVs and line filter for
normal and common
mode noise
Electro Static
Susceptibility
Receptacles
>15 KV
Standard NEMA receptacles or
IEC-320 female plugs; British
Standard and Schuko plugs
available. See Owner’s Manual
for details
INDICATORS AND CONTROLS
OUTPUT
On Battery
VAC Regulation
±5%; Sinusoidal wave
On Battery
Freq Regulation
±0.5%
Battery
Advanced charging for faster
recovery; 3 to 6 hours
North American units —
6-foot line cord with appropriate
NEMA plug; International units
— IEC 10 A Inlet Coupler
Protection
d
Pr
te
Battery Backup Time
Connections
60-Day Money Back
Guarantee
15:00
12 18
50/60 Hz; ±5%
◆
The lead-acid batteries typically used
in a UPS are considered viable as long
as they can maintain backup times of
at least half that of new batteries. The
illustration below shows that
batteries which are constantly trickle
charged (as are virtually all other
UPSs on the market today) reach the
end of their useful life in less than half
the time of batteries charged using
Advanced Battery Management
(ABM™). Our ABM uses a patented
three-stage charging technique that
not only doubles battery life, but also
speeds battery recharge time and provides up to a 60-day advanced notification of pending battery failure.
6
Nominal Input
Frequency
400-3000 VA; see Model
Selection Guide
Patented Advanced Battery
Management (ABM™) Technology
Doubles Battery Life
0
±20% standard;
also selectable for ±25%
Power Levels
e
Ra
cti
o-
ote
r
rP
te e
uaran
er Sati
sfaction G
On Line
Voltage Range
10-Year Pro-Rated
Warranty
ea
-Y
Cust
om
120, 208, or 230 VAC nominal;
see Model Selection Guide for
user selectable voltages
◆
10
TRIPLE
POWER
WARRANTY
Voltage
Battery Charging
Sealed, maintenance-free,
lead-acid
Battery Monitoring
Advanced monitoring for earlier
failure detection and warning
Backup Time
5 to 10 minutes at full load;
10 to 30 minutes and more with
typical partial load, depending
on model; see Estimated Backup
Times table
Serial
Communication
Intelligent serial communication
to provide alarms with history,
measured parameters, self-test,
and many other features
Front Panel
Interface
Ergonomic indicators including
Wiring Fault, Battery Service,
Communication Operation,
System Normal; bar graphs for
Input Level, Battery Charge
Level, % Load
Contact Closures
Input failure, Low battery
ON/OFF Control
Local and remote
PHYSICAL
Dimensions and
Weight
See Model Selection Guide
Audible Noise
Less than 45 dB, most models
Operating Temp
0°C - 40°C (32°F - 104°F)
Operating Humidity 0 to 95% non-condensing
Operating Altitude
Up to 10,000 feet above sea
level
Conformance
Standards
CE, IEEE 446, NEMA PE 1,
ANSI C62.41, FCC Class A & B,
CISPR, NSTA and others
Safety Standards
UL 1778, CSA C22.2, and VDE
PowerLink II SNMP Adapter
In addition to the comprehensive network power management available with
LanSafe III software, Deltec’s optional PowerLink II SNMP Adapter adds control
and monitoring capabilities for nonintelligent devices in SNMP-based networks. Working in concert with Deltec’s
LanSafe III, PowerLink II is a standard
MIB II compliant 10Base-T and 10Base-2
adapter, ideal for management of hubs,
routers, and other non-intelligent devices.
The compact device can be mounted
conveniently on the rear or side panel of
the UPS or any other suitable location.
Buck/Boost Voltage Regulation
Deltec’s exclusive Buck/Boost Voltage Regulation ensures consistent input voltage to your critical load. If the input voltage is too high, the PowerRite Pro
Bucks the voltage instantaneously (demonstrated in the illustration below) or
Boosts the voltage if it is too low. Deltec’s PowerRite Pro has the widest input
voltage window and tightest output regulation available which corrects
input voltage variations as large as
±25% without depleting the battery.
It is the only UPS in its class to meet
Computer & Business Equipment
Manufacturers Association (CBEMA)
voltage recommendations.
Power Management
Software Compatibility
The PowerRite Pro UPSs are compatible
with Deltec’s LanSafe III and FailSafe
III Power Management Software.
Together they ensure maximum data
integrity for computer users by
providing flexible, reliable, and
comprehensive control of UPSs
in networked or standalone
applications.
Via an RS-232 port on the rear
panel of the UPS, LanSafe III
gives network administrators
automatic orderly shutdown of
all network devices — including multiple servers and workstations during extended
power failures.
Indicates use of Buck/Boost
voltage regulation with Deltec’s
proprietary control circuitry
Utility power input voltage
Remaining run time while
on battery
Load capacity to
evaluate UPS utilization
Shows Deltec’s Advanced Battery
Management (ABM)TM in action —
preserving the life of your battery
Output voltage to
the computer
Features
◆
◆
◆
◆
PowerRite Pro Rack-Mount and Trim-Rack
◆
PowerRite Pro Rack-Mount UPSs offer ideal backup for rack-based computer
systems, servers, routers, hubs, multiplexers, and other sensitive electrical
equipment. Rack-Mount and Trim-Rack units incorporate all the advanced technology of the standard PowerRite Pro and are designed to fit in standard 19-inch
equipment racks. These UPSs are available in 120, 208, and 230 volt models with
power ratings from 600 to 3000 VA. Both the Rack-Mount and the Trim-Rack are
compatible with LanSafe III and FailSafe III power monitoring software and both
work with Deltec’s PowerLink SNMP Adapter.
◆
◆
◆
◆
Exclusive SafetyNetTM Sequential
Shutdown of all network devices
Work in progress is saved throughout the network
Remote control, testing and monitoring for all UPSs on the network
Paging and e-mail notification in
the event of a power failure
Customizable alerts with personalized message text and user list
Supports up to 64 network devices
with a single UPS
Multiple network device support
with a single UPS
Comprehensive power status data
displays
Supports other manufacturers’ UPSs
Operating Systems
◆
◆
The photograph to the left shows the PowerRite Pro
Trim-Rack mounted in a standard equipment rack.
The Trim-Rack also features Hot Swappable batteries.
FailSafe III Stand-alone Solutions
Windows 95, OS/2, Windows 3.x,
and Windows NT
LanSafe III Network Solutions
Windows 95, OS/2, UNIX, Novell
NetWare, MS DOS, Windows 3.x,
Windows NT, and Macintosh
TM
for OS/2
for IBM LAN
Model Selection Guide
Model
Nominal Input
Number
Frequency (Hz)1
North American Models
PRA400
50/60
PRA600
50/60
PRA1000
50/60
PRA1500
50/60
PRA20002
50/60
2
PRA2200
50/60
PRA30002
50/60
2
PRA2200b
50/60
PRA2200b L62
50/60
2
PRA3000b
50/60
International Models
PRA400i
50/60
PRA600i
50/60
PRA1000i
50/60
PRA1400i
50/60
2
PRA1800i
50/60
PRA2200i2
50/60
2
PRA3000i
50/60
Battery Box
—
Power
Out (VA)
Input/Output
Voltage (VAC)
Nominal Output
Current (Amp)
Dimensions
WxHxD (Inches/cm)
Weight
(lb/kg)
400
600
1000
1440
1920
2200
3000
2200
2200
3000
110/120/127
110/120/127
110/120/127
110/120/127
110/120/127
110/120/127
110/120/127
199/208/217
199/208/217
199/208/217
3.3
5.0
8.3
12.0
16.0
18.3
25.0
10.6
10.6
14.4
4.5x6.5x15.7/11x17x40
4.5x6.5x15.7/11x17x40
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
25/11.3
25/11.3
53/24
53/24
31/14.1
32.1/14.6
42/19.1
32.1/14.6
32.1/14.6
42/19.1
400
600
1000
1400
1800
2200
3000
48 V
220/230/240
220/230/240
220/230/240
220/230/240
220/230/240
220/230/240
220/230/240
—
1.7
2.6
4.3
6.1
7.8
9.6
13.0
—
4.5x6.5x15.7/11x17x40
4.5x6.5x15.7/11x17x40
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
7x9x16.7/18x23x42
25/11.3
25/11.3
53/24
53/24
31/14.1
32.1/14.6
42/19.1
65/29.5
1. 120 and 127 V operation for 60 Hz only. All other voltages for 50 and 60 Hz. 2. Uses PRA Battery Box. See Battery Box row for dimensions & weight.
Estimated Backup Times (in minutes)
PowerRite Pro Applications
External Hard Drive
80x86 or 680x0 PC, Hub
Intelligent Terminal, POS
80x86/680x0 PC w/Monitor
Pentium or Power PC
Router or Tape Drive
Workstation w/16" Monitor
Workstation w/19" Monitor
File Server w/Monitor
RISC Workstation
Super Workstations
Small Tower Mini
Telecom Equipment (high-end)
Multiple Workstations
Midrange Systems
Multiple Servers
Load
100 VA
250 VA
300 VA
350 VA
400 VA
450 VA
500 VA
600 VA
800 VA
1000 VA
1200 VA
1400 VA
1800 VA
2200 VA
2500 VA
3000 VA
PRA400
57
18
14
10
6
PRA600
95
33
24
19
15
13
11
6
PRA1000
155
55
40
36
30
27
23
19
12
8
PRA1500
235
90
59
52
43
39
35
29
20
13
10
7
PRA2000
395
255
205
180
140
125
100
75
53
33
26
22
14
PRA2200
395
255
205
180
140
125
100
75
53
33
26
22
14
10
PRA3000
395
255
205
180
140
125
100
75
53
33
26
22
14
10
8
7
This guide provides typical application information. Battery times are approximate and may vary with equipment, configuration, disk access, battery age, temperature, etc.
Call today for more information.
Innovators in Power Protection
2727 Kurtz Street ◆ San Diego, California 92110 ◆ USA
1-800-DELTEC-1 ◆ 619/291-4211 ◆ FAX 619/296-8039
e-mail: [email protected]
www: http://www.deltecpower.com
Windows is a registered trademark of Microsoft Corporation. OS/2 is a
registered trademark of International Business Machine Corporation.
Novell and NetWare are registered trademarks of Novell, Inc. Other
brand or product names are trademarks or registered trademarks of
their respective holders. Due to continuing product improvement
programs, specifications are subject to change without notice.
© Deltec Electronics Corporation 1996, my6/60-560