Download Type K Current Limiting Fuse Canister Technical and Installation
Ground (electricity) wikipedia , lookup
Mains electricity wikipedia , lookup
Current source wikipedia , lookup
History of electric power transmission wikipedia , lookup
Buck converter wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Rectiverter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Single-wire earth return wikipedia , lookup
Alternating current wikipedia , lookup
Surge protector wikipedia , lookup
Earthing system wikipedia , lookup
Type K Current Limiting Fuse Canister Technical and Installation Guide Table of contents 1 2 3 4 5 6 7 8 Page 2 of 8 Introduction ...................................................................................................................3 Ratings...........................................................................................................................3 Details ............................................................................................................................3 Interlocking....................................................................................................................4 Mounting........................................................................................................................4 Fuse Compatibility........................................................................................................4 Ordering Details ............................................................................................................5 Outline Drawing ............................................................................................................7 1 Introduction The Type K, current limiting fuse canister provides an air-insulated receptacle for generalpurpose current limiting fuses used on pad mounted or submersible transformers. The canister is mounted, typically, on the front wall of a single or three-phase distribution transformer or the cover of a submersible transformer. The Type K canister allows the operator easy access to the current limiting fuse for inspection or replacement. The Type K canister is of dead front construction once it is properly installed onto the transformer. Figure 1 shows the internal and external details of the canister. 2 Ratings The Type K current limiting canister is available in three voltage / BIL combinations: 1) 8.5 kV / 95 kV BIL, 175 A 2) 15 kV / 125 kV BIL, 175 A 3) 23 kV / 125 kV BIL, 175 A 3 Details The Type K current limiting canister features dead front construction, hermetic sealing, self-aligning spring contacts and stainless steel, corrosion-resistant components. The fuse canister is a dead break device and ABB recommends that it be used in conjunction with an interlocked LBOR, load break oil switch. The Type K, current limiting fuse canister consists of two major components: the first is a reinforced fiberglass tube welded to the tank by means of a stainless steel flange or bolted to the tank by means of an optional plated steel clamp and gasket. The second component is a removable fuse assembly consisting of the top closure, an insulated operating shaft, the fuse attachment clamp, top spring contact and guide washer. See Figure 3 and Figure 4. Figure 1 An operating lever combined with the internal cylindrical gasket creates an over toggle mechanism which when in the closed position provides a “bottle stopper” type seal between the inside of the canister and the atmosphere. Moving the operating lever into the closed position compresses the cylindrical gasket against the inside walls of the canister. Page 3 of 8 This action seals the canister. Moving the operating lever into the open (upright) position relaxes the gasket and the internal assembly can be removed for fuse replacement or inspection. Two spring clips provide the grounding of external metal parts. The spring clips are fixed to the body of the canister by the stainless steel hose clamp. The coil spring contacts at the top and bottom of the fuse assure positive fuse to transformer circuit connections. The top spring fits over the fuse attachment clamp on the holder assembly. The bottom spring is part of fiberglass tube assembly and makes contact when the fuse assembly is inserted into the holder and locked into position 4 Interlocking The Type K current limiting canister is a dead break device. ABB recommends that the fuse canister be mechanically interlocked to an LBOR, load break oil switch or other mechanism so that the fuse cannot be removed from or inserted into an energized transformer. 5 Mounting The Type K canister provides two means for attaching the canister to the transformer tank. The canister may be either welded to the transformer tank or bolted to the transformer tank. If the canister is welded onto the transformer, you must use heat sinks to prevent the welding heat from damaging the canister. The fuse canister can be bolted onto the transformer by using the optional mounting clamp and nitrile gasket. The mounting flange has a lip to capture the mounting gasket for these applications. Note that the grounding clips must be removed in order to slide the mounting flange into place. Once the mounting flange is secured, reinstall the grounding clips. 6 Fuse Compatibility The Type K canister accepts current limiting fuses of the type known as Full Range or General Purpose such as the Hi-Tech Trans-Guard™ FX fuse. The table below provides the maximum fuse dimensions for proper fit into the Type K canister. Voltage Class Maximum OD A (in) 8.3 kV 15.5 kV 23 kV 2.25 2.25 2.25 Figure 2 Page 4 of 8 Maximum Total Length B (in) 10.2 14.4 17.3 Connector Length C (in) 1.05 1.05 1.05 Connector OD D (in) 0.625 0.625 0.625 7 Ordering Details Item Number Voltage Dimensions See Figure 4 BIL A B C Clamp Gasket Welded to the Transformer 4260079-901 8.5 kV 95 kV 18.75 20.31 9.97 n/a n/a 4260079-902 15 kV 125 kV 23.13 24.69 14.35 n/a n/a 4260079-903 23 kV 125 kV 25.94 27.50 17.16 n/a n/a Bolted to the Transformer 4260079-904 8.5 kV 95 kV 18.75 20.31 9.97 9820A33H01 1210221-021 4260079-905 15 kV 125 kV 23.13 24.69 14.35 9820A33H01 1210221-021 4260079-906 23 kV 125 kV 25.94 27.50 17.16 9820A33H01 1210221-021 . Page 5 of 8 Figure 3: Type K Canister Part Detail Page 6 of 8 8 Outline Drawing Figure 4 Page 7 of 8 ABB Inc Components & Insulation Product Group 1128 South Cavalier Drive Alamo, Tennessee 38001, USA +1 731 696 5561 +1 800 955 8399 Fax: +1 731 696 5377 Email: Alamo.customer_service @us.abb.com www.abb.com/electricalcomponents Page 8 of 8 DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY THERE ARE NO UNDERSTANDINGS, AGREEMENTS, REPRESENTATIONS OR WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THOSE SPECIFICALLY SET OUT BY AN EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF SEELER. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT, COMMITMENT OR RELATIONSHIP. THE INFORMATION, RECOMMENDATIONS, DESCRIPTION AND SAFETY NOTATIONS IN THIS DOCUMENT ARE BASED ON OUR EXPERIENCE AND JUDGEMENT WITH RESPECT TO BUSHINGS. THIS INFORMATION SHOULD NOT BE CONSIDERED TO BE ALL INCLUSIVE OR COVERING ALL CONTINGENCIES. IF FURTHER INFORMATION IS REQUIRED. ABB INC. SHOULD BE CONSULTED. NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OR WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE, ARE MADE REGARDING THE INFORMATION, RECOMMENDATIONS, DESCRIPTIONS AND SAFETY NOTATIONS CONTAINED HEREIN. IN NO EVENT WILL ABB INC BE RESPONSIBLE TO THE USER IN CONTRACT, IN TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY OR OTHERWISE FOR ANY SPECIAL. INDIRECT. INCIDENTAL OR CONSEQUENTIAL DAMAGE OR LOSS WHATSOEVER INCLUDING BUT NOT UMITED TO DAMAGE TO OR LOSS OR USE OF EQUIPMENT, PLANT OR POWER SYSTEM, COST OF CAPITAL, LOSS OF PROFITS OR REVENUES, COST OF REPLACEMENT POWER, ADDITIONAL EXPENSES IN THE USE OF EXISTING POWER FACILITIES, OR CLAIMS AGAINST THE USER BY ITS CUSTOMERS RESULTING FROM THE USE OF THE INFORMATION, RECOMMENDATIONS, DESCRIPTION AND SAFETY NOTATIONS CONTAINED HEREIN Copyright 2009, ABB Inc. Document Number 1ZUA5670-301 Contact us