Technical Article Parallel & Series Operation CONTENTS • Parallel Operation • Series Operation This is only recommended with power converters specifically designed for parallel connection. A general comment is that it is much lower cost and causes far fewer problems to use a single power converter correctly rated for the application rather than two or more in parallel. However, there are power converters which feature master slave parallel operation. These units are intended for modular expansion schemes and fault tolerant parallel redundant power systems. Where power converters are overload protected by constant current limiting simple parallelling of the outputs can work to an acceptable standard. Output voltages must be set the same (as precisely as possible). In a two unit system the unit with the slightly higher output voltage will reach its current limit and the voltage will drop to equal that of the other unit. xppower.com Parallel Operation This converter will then supply the remaining current demanded by the load. So regulation can never be better than the difference between the output voltage settings of the two converters, and one unit will always be operating in current limit, therefore above its rating. Where current limits are adjustable to below maximum rating simple parallelling is satisfactory if the degradation of regulation can be tolerated. To improve load current sharing, equal series resistors can be used (See Fig. 1). Figure 1. Current sharing resistors used to parallel two converters For the best results the wiring resistance must also be exactly balanced. Small differences in the output voltage settings of the converter output still creates considerable current unbalance. In the example illustrated, the load is 5V at 2A. Converter output voltage settings are 5V but if they are unequal by 0.1V, the current out of balance from the nominal 1A is 0.5A. This requires that each unit is individually rated at 1.5A. It is clearly not a cost effective method of proving 5V 2A of stabilized power. Also the 100m series resistors degrade the regulation to worse than 2%. It should be bourne in mind that as the output power of the supply rises, the voltage drop and power dissipated rise. The power rating of the resistor should be carefully calculated. At higher currents, the series resistance should be reduced to perhaps 25-30mΩ. In critical applications where continuous operation is essential, parallel redundant power systems are often specified. The system has to keep running even when a power unit fails. Current sharing is not such an important criterion since each power unit must be rated to supply the total load. But to enable both units to be continuously monitored for faults it is advisable that some measure of current sharing takes place. Both units are then always operating. Isolating series diodes which are continuously rated at the full load current allow either power converter to continue operation unaffected by a fault in the other. Matching the forward resistance of the diodes and balancing the wiring resistance helps with the current sharing. However, these series impedance degrade the regulation. Some power converters, which are specifically designed for use in fault tolerant systems allow remote sense downstream of the parallelling diodes to maintain full regulation at the load. In a parallel redundant scheme one of the power converters could be replaced by a battery followed by a DC-DC converter to provide a no-break power system in the event of main supply failure (See Fig. 2) Figure 2. Isolated diodes used for parallel redundant connections of two converters 2 xppower.com Series Operation Most power converters can be operated in series if they have overload limit characteristics, constant current or constant power circuits. With some switching converters series operation is prohibited because one unit upsets the feedback regulation system of the other. With linear and switched mode units using foldback current limiting, lock out at switch ON can occur because of the different ramp up times of two units in series. Care must be taken not to exceed the safe working voltage at the outputs of converters in series. This may be considerably lower than the dielectric strength test voltage which is a short-term test between outputs and ground. The output ripple of converters in series is additive but this of course does not change the value of ripple expressed as a percentage of total output voltage. To protect each output from the reverse voltage applied by the other unit in the event of load short circuits, reverse biased diodes are used. It is common practice to include these protection diodes in laboratory power supplies. Figure 3. Outputs connected in series showing reverse voltage protection diodes 3 --www.xppower.com North American HQ Asian HQ XP Power 990 Benecia Avenue, Sunnyvale, CA 94085 Phone : +1 (408) 732-7777 Fax : +1 (408) 732-2002 Email : [email protected] XP Power 401 Commonwealth Drive, Haw Par Technocentre, Lobby B, #02-02, Singapore 149598 Phone : +65 6411 6900 Fax : +65 6741 8730 Email : [email protected] Web : www.xppowerchina.com / www.xppower.com North American Sales Offices Toll Free.........................+1 (800) 253-0490 Central Region...............+1 (972) 578-1530 Eastern Region ............+1 (973) 658-8001 Western Region.............+1 (408) 732-7777 Asian Sales Offices Shanghai ....................... +86 21 51388389 Singapore.......................... +65 6411 6902 European HQ German HQ Distributors XP Power Horseshoe Park, Pangbourne, Berkshire, RG8 7JW, UK Phone : +44 (0)118 984 5515 Fax : +44 (0)118 984 3423 Email : [email protected] XP Power Auf der Höhe 2, D-28357 Bremen, Germany Phone : +49 (0)421 63 93 3 0 Fax : +49 (0)421 63 93 3 10 Email : [email protected] Australia ..........................+61 2 9809 5022 Balkans ...........................+386 1 583 7930 Czech Rep. ...................+420 235 366 129 Czech Rep. ...................+420 539 050 630 Estonia ................................+372 6228866 Greece ..........................+30 210 240 1961 Israel ................................+972 9 7498777 Japan ..............................+81 48 864 7733 Korea ..............................+82 31 422 8882 Latvia ................................+371 67501005 Lithuania...........................+370 5 2652683 Poland..............................+48 22 8627500 Portugal..........................+34 93 263 33 54 Russia ...........................+7 (495)234 0636 Russia ...........................+7 (812)325 5115 South Africa.....................+27 11 453 1910 Spain..............................+34 93 263 33 54 Taiwan ..............................+886 3 3559642 Turkey ...........................+90 212 465 7199 European Sales Offices Austria ........................+41 (0)56 448 90 80 Belgium .....................+33 (0)1 45 12 31 15 Denmark ..........................+45 43 42 38 33 Finland........................+46 (0)8 555 367 01 France ......................+33 (0)1 45 12 31 15 Germany....................+49 (0)421 63 93 3 0 Italy ................................+39 039 2876027 Netherlands ...............+49 (0)421 63 93 3 0 Norway.............................+47 63 94 60 18 Sweden ..................... +46 (0)8 555 367 00 Switzerland ................ +41 (0)56 448 90 80 United Kingdom.........+44 (0)118 984 5515 Amtex Elbacomp Vums Powerprag Koala Elektronik Elgerta ADEM Electronics Appletec Bellnix Hanpower Caro Elgerta Gamma Venco Prosoft Gamma Vepac Venco Fullerton Power EMPA Global Catalog Distributors Americas ........................................Newark Europe & Asia...................................Farnell China ............................Premier Electronics newark.com farnell.com premierelectronics.com.cn May-07