* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 901-106 D SLP.qxp
Variable-frequency drive wikipedia , lookup
Electrical ballast wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Switched-mode power supply wikipedia , lookup
History of electric power transmission wikipedia , lookup
Current source wikipedia , lookup
Voltage regulator wikipedia , lookup
Single-wire earth return wikipedia , lookup
Buck converter wikipedia , lookup
Protective relay wikipedia , lookup
Electrical substation wikipedia , lookup
Power electronics wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Power MOSFET wikipedia , lookup
Ground (electricity) wikipedia , lookup
Stray voltage wikipedia , lookup
Alternating current wikipedia , lookup
Opto-isolator wikipedia , lookup
Mains electricity wikipedia , lookup
National Electrical Code wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
SLP Series Ultra-slim user-friendly devices for protecting electronic equipment and systems against surges on signal and I/O cabling G Surge protection for two loops per SLP (or one 4-wire circuit) G Range of ATEX Certified intrinsically safe surge protectors G Space-saving design; easy installation G Multi-stage hybrid protection circuitry – 20kA maximum surge current G Range of voltage ratings -- to suit all process I/O applications G Designed for high bandwidth, low resistance applications The SLP Series is a range of surge protection devices combining high packing densities, application versatility, proven hybrid circuitry and simple installation – features which make the series the most cost effective surge protection solution for process control equipment systems and communications networks. The multi-stage hybrid surge protection network at the heart of the SLP uses a combination of solid state electronics and a gas filled discharge tube (GDT) to provide surge protection up to 20kA. This impressive surge protection circuit is designed to exhibit exceptionally low line resistance and adds only a tiny voltage drop to the circuit. In operation, the SLP device does not adversely affect the performance or operation of the loop or combined equipment. The device allows signals to pass with very little attenuation while diverting surge currents safely to earth and clamping output voltages to safe levels. provides the essential high-integrity earth connection. Fully automatic in operation, SLP devices react immediatley to make sure that equipment is never exposed to damaging surges between lines or the lines and earth. Reacting instantaneously, the SLP redirects surges safely to earth and then resets automatically. A 10 Year ‘No Fuss’ warranty is available as standard for the SLP so if a correctly connected device should fail for any reason, simply return it for a free replacement. The versatile SLP series design considers the need for high packing densities and has a product combining protection for two process loops into one case. Each module provides full hybrid surge protection for two process loops. ‘Top-hat’ (T-section) DIN rail is generally suitable for mounting SLP modules although for adverse environments, a specially-plated version is available from MTL Surge Technologies. For higher bandwidth applications, the SLP series has been developed to meet the demands of today’s highest speed communication systems. One simple manual operation clamps modules securely onto DIN rail, which automatically Data & Signal Protection Specification (all figures typical at 25°C unless otherwise stated) Model Maximum surge current 20kA (8/20μs waveform) per line Leakage Current <1μA @ working voltage Maximum rated load current 1.50A Loop resistance 2 Ohm Capacitance Line - Line - 60pF Bandwidth -0.1db @9kHz - 37MHz -3dB @50MHz Response time <1ns Ambient temperature –40°C to +80°C (working) –40°F to +176°F (working) –40°C to +80°C (storage) –40°F to +176°F (storage) Humidity 5 to 95% RH (non-condensing) Terminals 2.5mm2 (12 AWG) Electrical connections Plug/header screw terminal strip Mounting T-section DIN-rail (35 x 15mm rail) Weight 5oz (140g approximately) Case flammability UL94-V0 EMC compliance BS EN 60950:1992 BS EN 61000-6-2:1999 BS EN 61010-1:1993 Nominal voltage Un Uc In Rated voltage (MCOV) Nominal current Nominal discharge current (8/20µs) SLP07D SLP16D SLP32D 7V 16V 24V 8V 18V 32V 1.50A 1.50A 1.50A Lightning impulse current (10/350µs) isn Imax Iimp 2.5kA 2.5kA Residual voltage @ isn Voltage protection level @ 1kV/µs Up Up 10V 23V 40V <8V <18V <38V Bandwidth fG C 50MHz 50MHz 50MHz Capitance 60pF 60pF 60pF Series resistance R 1.0 1.0 1.0 Max discharge current (8/20µs) 3kA 3kA 3kA 20kA 20kA 20kA 2.5kA Operating Temperature Range Category tested -40°C to +80°C A2, B2, C1, C2, C3, D1 Overstressed fault mode in=3kA Impulse durability (8/20µs) 22kA 22kA 22kA 10kA 10kA 10kA Degree of protection IP20 AC durability 1Arms, 5T 80kPa - 160kPa 5% - 95% RH Service conditions Tested in accordance to IEC 61643-21. Loop 1 Loop 2 Figure 1 Dimensions Figure 2 Connection details To order specify Order by module, as listed in the specification table. Note: In accordance with our policy of continuous improvement, we reserve the right to change the product’s specification without notice. Figure 3 Installation Approvals WWW: www.mtlsurge.com A member of the MTL Instruments Group plc Country (Authority) Standard Certificate/ File No. Approved for ATEX BS EN 60950:1992 BS EN 61000-6-2:1999 BS EN 61010-1:1993 ATEX0377X EEx N IIC T4 SLP07D, SLP16D, SLP32D EN50014:1997-A1 & A2 Baseefa 04 EN50020:2002 ATEX0303X EN50284:1999 EEx ia IIC T4 SLP07D, SLP16D, SLP32D EC [Baseefa] Product 901-106 Rev E 1/9/07 MTL Surge Technologies Power Court, Luton, Bedfordshire, England LU1 3JJ Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 E-mail: [email protected] SD Series Ultra-slim user-friendly devices for protecting electronic equipment and systems against surges on signal and I/O cabling G Range of ATEX Certified intrinsically safe surge protectors G Ultra-slim space-saving design; easy installation G Multistage hybrid protection circuitry – 10kA maximum surge current G Range of voltage ratings -- to suit all process I/O applications G High bandwidth, low resistance, RTD, PSTN and 3-wire transmitter versions available The SD Series is a range of surge protection devices combining unparalleled packing densities, application versatility, proven reliable hybrid circuitry, simple installation and optional ‘loop disconnect’ facilities – features which make the series the ultimate surge protection solution for process equipment, I/O systems and communications networks. The exceptionally high packing densities are the consequence of an ultra slim ‘footprint’ for individual modules which can thus ‘double-up’ as feedback terminals. Each module provides full hybrid surge protection for 2 and 3 wire loop protection. Modules with a comprehensive range of voltage ratings cover all process related signals such as RTDs, THCs, 4 to 20mA loops, telemetry outstations, shut-down systems and fire and gas detectors. Optional ‘loop disconnect’, is a feature which allows commissioning and maintenance to be carried out without removal of the surge protection device. This facility is provided by the SD07, SD16, SD32 and SD55 units. In addition, a third connection on the field and safe side of the protector is provided in order to terminate screens safely. For three wire applications the specially (Resistance designed SDRTD Temperature Detector) and the SD32T3, (for separately powered 4-20mA loops) provide full 3-wire protection in a single compact unit. The recommended choice for the protection of 3-wire pressure transducers on low power circuits is the SD07R3. Telephone networks can be protected by the SDPSTN. One simple manual operation clamps modules securely onto DIN rail, which automatically provides the essential highintegrity earth connection. ‘Top-hat’ (T-section) DIN rail is generally suitable for mounting SD modules although for adverse environments, a specially-plated version is available from MTL Surge Technologies. A comprehensive range of mounting and earthing accessories can also be supplied, see page 7 for further details. For higher bandwidth applications, the SDR series has been developed to meet the demands of today’s highest speed communication systems. 120V and 240V AC versions are available for I/O and power supplies up to three Amps of load current. Data & Signal Protection Guide to applications and selection The SD Series of SPDs includes models for almost all possible applications operating at voltages up to 250V ac. The optional ‘fuse/disconnect’ package provides both fused protection against fault currents and a convenient method of isolating field circuitry from protected circuitry without needing additional disconnect terminals. The standard fuse (which is replaceable) is rated 250mA with 50mA fuses also being available by special request. Where only the disconnect feature is required, solid links can be used. As an example, this feature is of particular value in applications in which an SPD is used with a bulk power supply feeding multiple loops. The individual module fuse prevents a fault or follow on current on one loop disrupting the power supply to the others. Also, loops can be removed from the circuit for maintenance reasons or added without needing additional disconnect terminals. The following guide to selection suggests the most suitable SDs for a number of specific applications. For technical information, see the detailed specifications on the back page of this publication (some field circuit protection is shown for completeness). FIELD CIRCUIT Analogue inputs (high-level) 2-wire transmitters, 4-20mA, conventional and smart The SPDs recommended for use with ‘conventional’ and ‘smart’ 4-20mA transmitters (fed by a wellregulated supply) are the SD32 and SD55, the choice depending upon the maximum working voltage of the system (32V and 55V respectively). The diagram illustrates a prime example of an application for which the fuse/disconnect facility is particularly useful, however, both models are available in ‘X’ versions without the optional fuse/disconnect feature. 2-wire transmitters Analogue inputs (low-level) RTDs These applications are best served using the SDRTD. For optimum accuracy, the energising current should be chosen to ensure the voltage across the RTD does not exceed 1V over the full measurement range. When using a PT100 device, we recommend an energising current of 1mA. 3 wire RTDs Photocells, THCs, mV sources and turbine flowmeters The SD07 or SD16 (depending upon the operational voltage) are the favoured choices for this application. SD07X and SD16X are also suitable. photocells, THCs, mV sources and turbine flowmeters 2 PROTECTED CIRCUIT FIELD CIRCUIT PROTECTED CIRCUIT Analogue outputs Controller outputs (I/P converters) For this application, the recommendations are the SD16, SD32 and SD55 (and the equivalent ‘X’ versions), the final choice depending upon the operating voltage. Controller outputs (I/P converters) Digital (on/off) inputs Switches Suitable SPDs for switches include the SD07, SD16, SD32 and SD55 modules – the choice depending upon the operating voltage of the system. The ‘X’ versions of these are also suitable. Switches Digital (on/off) outputs Alarms, LEDs, solenoid valves, etc The recommended choice for this application is the SD32 or SD32X. Alarms, LEDs, solenoid valves, etc. Telemetry (PSTN) Telemetry outstations The SDPSTN has been designed specifically for the protection of signals transmitted on public switched telephone networks. Telecom line AC supplied equipment PLC, I/O systems For systems on 110-120V ac, the SD150X is the recommended choice and for 220-240V ac systems, the SD275X is recommended. PLC, I/O systems 3 Transmitter and sensor protection Transmitters and sensors are widely used in highly exposed areas and where lightning damage is common. In many cases, the ideal solution for 2-wire transmitters or sensors is the TP48 which mounts directly onto the transmitter housing via spare cable entries. Where these entries are not available or 3-wire devices are used, the compact design and simple installation of the SD series makes it the obvious choice for transmitter protection. The SDs within the junction box should be installed no further than one metre away but as close as possible to the sensor or transmitter they are protecting. A bond is required from the general mass of steelwork to the sensor or transmitter housing either using a flat short braid or a cable of at least 4mm2 cross sectional area. In most instances this bond is automatically made by fixing the metallic transmitter housing to the plant structure. This bond ensures the voltage difference between the signal conductors and the transmitter housing is below the transmitter’s insulation rating. Please note that the transmitters or sensors are connected to the ‘Protected Equipment’ terminals of the SD and not the ‘Field Cables’. SD PROTECTED FIELD CIRCUIT 2-wire transmitters or sensors 4-20mA transmitters, conventional and smart Where the TP48 is not an acceptable solution, either because of technical suitability or difficulties in mounting, the SD16X, SD32X and SD55X are an excellent alternative. 2-wire transmitter or sensor 3-wire transmitters or sensors Vibration Sensors and 4-20mA loop process control systems invariably require three wire connections, when powered from an external source. This may be accomplished in one unit by using the SD32T3 three terminal Surge Protection Device (SPD). Because the SD32T3 protects all three conductors within the same unit, higher protection is achieved, as the SPD hybrid circuitry is common to all three wires. The SD07R3 is available for the protection of 3wire pressure transducers on low power circuits. 3-wire transmitter or sensor 4-wire transmitters or sensors Flow meters, level detectors, etc. 4-wire systems such as level detectors require two SDs, one for the supply and the other for the transmitter output. Generally the voltages across the pairs are similar and so the recommended choice would be a pair of SD16X, SD32X or SD55Xs. However, mains powered transmitters should be protected with an SD150X or 275X (depending upon supply voltage) for the supply inputs. Loadcells are catered for by MTL Surge Technologies’ LC30 which is suitable for both 4 and 6-wire load cells. 4 4-wire transmitter or sensor TO HOST CIRCUIT Communication systems protection High speed data links between buildings or one part of a plant to another have become more common with the widespread use of smart transmitters and the increase in unmanned installations. The SD series has an SPD suitable for all process I/O applications with a choice of low resistance units, high bandwidth and a variety of voltage variants. The SDR series has been specially designed to meet the requirements for high speed data links with an extremely high bandwidth. TP PROTECTED FIELD CIRCUIT SD PROTECTED HOST CIRCUIT Communication systems RS232, RS422, RS485 The recommended choice for these applications is the SD16R or SD32R depending on the maximum driver signal. RS232, RS422, RS485 Bus powered systems There are a variety of bus powered systems specially designed for the process industry. The ideal surge protection device for these systems is the SD32R as it has a very high bandwidth and a modest in-line resistance. PROTECTED FIELD CIRCUIT SD PROTECTED HOST CIRCUIT Bus powered systems Table 1 Typical Applications Table 1 shows suitable SD devices for different applications. In some applications alternative devices may be used, for example, where lower in-line resistance or a higher voltage power supply is used. Telematic have operationally tested the recommended SD series with representative highways listed but no formal approval for their use in systems by the respective bodies has been sought. Application Allen Bradley Data Highway Plus Preferred SPD Alternative SD16R Foundation Fieldbus 31.25kbits/s voltage mode SD32R 1.0/2.5 Mbits/s SD55R HART SD32X SD32, SD32R Honeywell DE SD32X SD32, SD32R LonWorks FFT-10 SD32R LPT-10 SD55R TP-78 SD07R IS78† SD32R Modbus ‘& Modbus Plus (RS485) SD16R PROFIBUS DP PA (IEC 1158, 31.25 kbits/s) SD32R FP32 RS232 SD16 RS422 SD07R RS423 SD07R RS485 SD07R WorldRP (IEC 1158) SD32R SD16X 31.25 kbits/s voltage mode 1.0/2.5 Mbits/s SD55R 5 Hazardous area applications Zone 0/Zone 1 Installation The dangers from lightning induced sparking in Zone 0 are considered real enough to require preventative measures. IEC 60079-14 (199612) Electrical apparatus for explosive gas atmospheres Part 14: Electrical installations in hazardous areas (other than mines) stresses the importance of SPDs in hazardous areas. An outdoor installation where there is a high likelihood of both lightning induced transients and combustible gases requires the installation of SPDs to prevent possible ignition of the gases. Areas seen particularly at risk include flammable liquid storage tanks, effluent treatment plants, distillation columns in petrochemical works and gas pipelines. Positioning The SDs should be mounted on the field wiring side to ensure that any surges entering from the field do not damage any intrinsically safe barriers or galvanic isolators in the system. The SDs and IS interfaces should be mounted close to each other but on separate DIN rails in order to maintain the required 50mm clearance between safe area and hazardous area terminals. SPDs for transmitter protection should be installed in Zone 1 but sufficiently close to the Zone 0 boundary to prevent high voltages entering Zone 0. The distance from the SPD to Zone 0 should be less than one metre where possible. However, in practice the SPD would normally be mounted on the transmitter or sensor housing which usually lies in Zone 1 and is very close to Zone 0. Because there is only a very small free volume, the SD Series is suitable for mounting in flameproof or explosion proof enclosures. Zone 2 The SD series is suitable for protecting electrical circuits in Division 2, Zone 2 and can be used without affecting the safety aspects of the circuit. Non-incendive (low-current) circuits can be protected using any SD series unit mounted in either the safe or hazardous area including those with the fuse disconnect facility. Non arcing (high current) circuits can also be protected except that SPDs with the fuse disconnect facility may only be mounted in the safe area. For use in these circuits the units must be mounted in a suitable enclosure, normally the minimum requirements are IP54 and 7Nm resistance to impact. The SD series is self certified by Telematic Ltd as being suitable for this purpose. Certification Introducing surge protection into Intrinsically Safe (IS) circuits is trouble free as long as the current and power parameters are not exceeded. In the SD Series, the SD**X, SD**R, SD**R3, SDRTD and SD**T3 all have ATEX certification for use in IS circuits located in Zones 0, 1 or 2. The certification parameters for the SD**X and SD**T3 are: EEx ia IIC T4, Li = 0.22mH Ii = 260mA for Ui up to 20V Ii = 175mA for Ui up to 26V Ii = 140mA for Ui up to 28V Ii = 65mA for Ui up to 60V The certification parameters for the SD**R, SD**R3 and SDRTD are: EEx ia IIC T4, Li = 0 Ii = 260mA for Ui up to 60V The power rating for each of the above is dependent on the table shown below. Pi = 1W (–30°C to +75°C) Pi = 1.2W (–30°C to +60°C) Pi = 1.3W (–30°C to +40°C) 6 The SD** Series are classifed as simple apparatus and are intended for use in Zone 2 or safe areas only, because their fuses are not fully encapsulated. Earthing The recommended earthing for field mounted devices has been illustrated previously but it is the earthing at the control panel that is more critical as there are usually a number of earthing systems, each with their own requirements. The earthing system illustrated here replaces the instrument 0V bond, the control system PSU bond and the IS earth with one single earth connection to meet all the design requirements and give the most effective protection against the effects of lightning induced surges. SD Series mounting kits and accessories The SD Series has a full range of mounting kits and accessories to simplify installation and tagging of individual loops. Insulating spacers (ISP7000) are available to allow mounting of the units onto backplanes without compromising correct earthing practice. These are placed at regular intervals along the rail or at each end as required. Earth connections can be made to the DIN rail via the earth terminal (ETL7000). Weatherproof enclosures are also available with all the necessary mounting accessories to install the SD series surge protection devices. Two tagging systems are available. One consists of tagging strips (TAG57) with labels (TGL57) mounted on posts (IMB57) at each end of a row of surge protection devices (SPDs). The other consists of separate tagging identifiers (BRI7000) mounted on the tops of individual SPDs. Both methods can be used conjointly. Replaceable fuses or solid links are available in packs of 5 (SDF25, SD-F05 and SD-LNK). Mounting accessories ISP7000 Insulating spacer THR2 Standard DIN rail, 35mm x 7.5mm THR7000 T-section DIN rail, specially nickel plated, 35mm x 7.5mm, 1m length Earthing/earth rail accessories ETL7000 Earth terminal, DIN rail mounted IMB57 Insulated mounting block (two needed) ERB57S Earth rail bracket, straight ERB57O Earth rail bracket, offset ERL7 Earth rail, 1m length ETM7 Earth terminal, pack of 50 Tagging accessories TAG57 Tagging strip, 1m length TGL57 Tagging strip labels, set of 10 x 0.5m BRI7000 Barrier identifier BIL7000 Barrier indentification labels, sheet of 120 BIL7000L Barrier identification labels, A4 sheet of 126 Enclosures DX070 Enclosure for up to 9 x SD series SPDs DX170 Enclosure for up to 22 x SD series SPDs DX430 Enclosure for up to 58 x SD series SPDs Accessories (replacement) SD-F25 Replaceable fuse pack - 250mA standard (available in packs of 5) SD-F05 Replaceable fuse pack - 50mA special (available in packs of 5) SD-LNK Solid Link (available in packs of 5) DIMENSIONS (mm) 7 Specification (all figures typical at 25°C unless otherwise stated) Model Protection Full hybrid line to line Each line to screen/ground Max. discharge surge current (Imax ) (Vdc) (8/20µs) 10kA 6.5kA (SD150X and SD275X only) Max. discharge surge current (i sn ) (10/350µs) 2.5kA 1.0kA (SD150X and SD275X only) Response time <1ns RTD resistance range (SDRTD) 10 to 1500Ω Degradation accuracy (SDRTD at 1mA) 0.1% (RTD resistance > 100Ω) 0.1Ω (RTD resistance < 100Ω) Ambient temperature –40°C to +80°C (working) –40°C to +80°C (storage) Humidity 5 to 95% RH (non-condensing) Category tested A2, B2, C1, C2, C3 Overstressed fault mode i n=3kA 12kA 9kA (SD150X and SD275X only) Impulse durability (8/20 μs) 10kA 6.5kA (SD150X and SD275X only) Terminals 2.5mm2 (12 AWG) Mounting T-section DIN-rail (35 x 7.5 or 35 x 15mm rail) Weight 70g approximately Case flammability UL94 V-2 AC durability 1Arms, 5T Service conditions 80kPa - 160kPa 5% - 95% RH EMC compliance To Generic Immunity Standards, EN 50082, part 2 for industrial environments R&TTE compliance EN 50082-2 : 1995 EN 41003 : 1999 EN 60950 : 1992 (not applicable to SD150X and SD275X) LVD compliance SD150X & SD275X EN 60950 : 1992 EN 61010 : 1995 SDPSTN EN 41003 : 1999 IEC compliance EN 61643-21:2001 To order specify Order by module, as listed in the specification table and/or accessory part numbers as defined on page 7. Note: In accordance with our policy of continuous improvement, we reserve the right to change the product’s specification without notice. (Vac) Rated Voltage voltage Protection (MCOV) level (U p) Residual voltage Bandwidth (Frequency) @1kV/ μs @isn (mA) (Ω/line) (µA) (Uc) (V) (V) (f G) Special feature SD07 7 5 250 4.2† 500 7.7 <12 30 25kHz SD16 16 11 250 4.2† 5 17 <25 40 25kHz Fuse Disconnec SD32 32 22 250 4.2† 5 36 <45 60 25kHz Fuse Disconnect SD55 55 38 250 4.2† 5 62 <90 100 25kHz Fuse Disconnect Fuse Disconnect 5 400 2.7 500 7.7 <12 30 50MHz High Bandwidth 11 400 4.7 5 17 <25 40 50MHz High Bandwidth SD07R 7 SD16R 16 SD32R 32 22 400 10 5 36 <45 60 50MHz High Bandwidth SD55R 55 38 400 10 5 62 <90 100 50MHz High Bandwidth 5 400 2.2 500 7.7 <12 30 25kHz Low Resistance 11 400 2.2 5 17 <25 40 25kHz Low Resistance SD07X 7 SD16X 16 SD32X 32 22 400 2.2 5 36 <45 60 25kHz Low Resistance SD55X 55 38 400 2.2 5 62 <90 100 25kHz Low Resistance SD32T3 32 22 400 2.2^ 5 10** 36 <45 60 720kHz 3 Terminal SD07R3 7 SD16R3 16 SD32R3 32 SD55R3 55 5 400 2.7 500 7.7 <12 30 50MHz 3 Terminal 11 400 4.7 5 17 <25 40 50MHz 3 Terminal 22 400 10 5 36 <45 60 50MHz 3 Terminal 38 400 10 5 62 <90 100 50MHz 3 Terminal 0.75 10 2.7 0.3 5 <12 30 50MHz 3-wire RTD 5 175 <200 235 4MHz PSTN SDRTD 1 SDPSTN 162 114 550 4.7 SD150X 170 20 3A‡ 0.1 250 ac dc rms 170 130 <400 450 - High current SD275X 339 240 3A‡ 0.1 250 350 275 <700 850 - High current ac rms Note: all figures are typical at +25°C unless otherwise stated; *standard fuse; +over full working temperature range; †at 20mA with a 250mA standard fuse; ‡these units need external 3A fuses; ^Signal; **Power & Common; maximum energising current depends upon RTD resistance. Blue colour signifies products ATEX certified EEx ia IIC T4. Definitions of terminology used in table 1 Working voltage (Un) 2 Maximum voltage between lines or lines/ ground for the specified leakage current Maximum leakage current (I c) 3 Maximum current drawn by the SPD at the working voltage Maximum continuous operating voltage (U c) 4 protected terminals without damage Voltage protection level (Up) 5 Peak output voltage after injection of test impulse from 1kV/μs generator (often known as ‘let-through’ voltage) Bandwidth Frequency range up to which ac signals can be transmitted without undue attenuation; 3dB into 50Ω (600Ω for the SDPSTN) Maximum voltage that can be applied to the Approvals Country (Authority) Standard Certificate/ File No. Approved for BASEEFA (EC) EN 50014:1997 EN 50020:2002 EN 50284:1999 BASEEFA 02ATEX0211X EEx ia IIC T4* Product SD07X,SD16X,SD32X, SD55X,SD07R, SD16R, SD32R,SD55R,SDRTD, SD32T3,SD07R3,SD16R3, SD32R3,SD55R3 CSA/C/US CSA C22.2 No. 0-M1991 LR 103652-3 EEx ia Class 1, SD07,SD16,SD32,SD55, (Canada, USA) CSA C22.2 No. 157-M1992 Groups A, B SD07X,SD16X,SD32X, UL 913, 5th edition C and D, T4 SD55X,SD07R,SD16R, CSA C22.2 No. 142-M1987 Class 1, Div 2 SD32R,SD55R,SDRDT, CSA C22.2 No. 213-M1987 Groups A,B,C, D T4 SD32T3,SD07R3,SD16R3, UL 508, 17th edition SD32R3,SD55R3 UL 1604, 3rd edition UL UL 497B Listed E220693 Isolated loop SD07,SD16,SD32,SD55 (USA) communication SD07X,SD16X,SD32X circuits SD55X,SD07R,SD16R SD32R,SD55R,SD07R3 SD16R3,SD32R3,SD55R3 SD32T3,SD55T3, SD07X3,SD16X3,SD32X3, SD55X3,SDRTD UL UL 1449 2nd Edition E217523 AC power SD150X,SD275X (USA, Canada) Recognised Component protection Austel AS/NZ3548:1995 __ Private Wire SD07R (Australia) AS/NZS4117:1996 TS001: 1997 * See page 6 for further details MTL Surge Technologies Power Court, Luton, Bedfordshire, England LU1 3JJ Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 E-mail: [email protected] WWW: www.mtlsurge.com A member of the MTL Instruments Group plc Nominal Series Max. current resistance leakage (I n) current 901-107 Rev H 5/03/06 3kA (8/20µs) Lightning impulse current (Iimp) Nominal voltage+ (U n) FP32 Din rail mounting, 20kA surge protection for Fieldbus systems G DIN rail mounting for easy installation and automatic earthing G 20kA maximum surge current per line G Plug connectors for quick and easy connection or rewiring G Meets the requirements of IEC 611582:2000 for FOUNDATION FIELDBUS G 10 year product warranty The FP32 surge protection device prevents surges and transient overvoltages conducted along the Trunk or Spurs of fieldbus systems from damaging the associated electronics such as terminators, spur blocks and the bus control equipment. The FP32 is designed to be used at both ends of the Trunk where a Spur is connected to safely divert any surges to earth. The multi-stage hybrid surge protection network at the heart of the FP32 uses a combination of solid state electronics and a gas filled discharge tube (GDT) to provide surge protection up to 20kA. This impressive surge protection circuit is designed to exhibit exceptionally low line resistance and adds only a tiny voltage drop to the bus. As a result, no matter how many FP32 devices are connected to a Trunk or Spur the system will still be able to support its full 32 transmitters as specified by IEC 61158-2. In operation the FP32 device does not adversely effect the performance or operation of the fieldbus or connected equipment, it allows signals to pass with very little attenuation while diverting surge currents safely to earth and clamping output voltages to safe levels. removing a device or re-patching a simple operation. Fully automatic in operation, FP32 devices react immediately to make sure that equipment is never exposed to damaging surges between lines or the lines and earth. Reacting instantaneously the FP32 redirects surges safely to earth and then resets automatically. The FP32 meets IEC 61158-2:2000 for 31.25kB/s systems such as FOUNDATION Fieldbus, PROFIBUS-PA and WorldFIP. A 10 Year ‘No Fuss’ warranty is available as standard for the FP32, so if a correctly connected device should fail for any reason, simply return it for a free replacement. Din rail mounting and a small footprint allow the FP32 to be conveniently located near terminators and spur blocks while plug connectors for Trunk / spur cables and the earth & shield of the cable make Fieldbus Protection Specifications All figures typical at 25°C - 70°C (77°F - 158°F) unless otherwise stated Maximum surge current 20kA (8/20µs waveform) per line Leakage current <1μA @ working voltage Working voltage ±32Vdc Maximum continuous operating voltage ±36V peak normal mode ±225V peak common mode Limting voltage 62V @ 3kA 8/20µs Line resistance 0.5Ω per line Capacitance Line - Line - 40pF Line - Earth - 80pF Attenuation -1dB - 7kHz-7.5mHz Ambient temperature limits -20C - +70C (working) -40C - +80C ( storage) Humidity 5% to 95% RH (non-condensing) Electrical connections Plug/header screw terminal strip Weight 5.0 oz (140g approx) Dimensions See figure 1 EMC compliance BS EN 60950:1992 BS EN 61000-6-2:1999 BS EN 61010-1:1993 Electrical Safety ATEX II 3 G DOC #MTL02ATEX0032X Figure 1 Dimensions Figure 2 Installation Figure 3 Connection details Approvals Standard/Authority Certificate/File No. Approved for Product ATEX Directive 94/9/EC FISCO (BASEEFA) BASEEFA04ATEX0260X EEx ia IIC T4 EEx ia IIB T3 (-40°C≤Ta≤70°C) FP32 USA (FM) 3022293 Class Nos. 3600 (1998), 3610 (1999), 3611 (1999), 3615 (1989), 3810 incl. Supp 1 (1995-07 (1989-03), ANSI/NEMA 250 (1991), ISA-S12.0.01 (1999) 3025374 C22.2 No. 213, 142, 94, 157, 30 ANSI/NEMA 250 CAN/CSA-E79-0 CAN/CSA-E79-11 IS/I/1/ABCD I/0/Ex ia/IIC I/0/Ex ib/IIC NE/I/2/ABCD NE/I/2/IIC FP32 India Petroleum & Explosives Safety Organisation (PESO) EEx ia IIB T3 FP32 MTL Surge Technologies Power Court, Luton, Bedfordshire, England LU1 3JJ Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 E-mail: [email protected] WWW: www.mtlsurge.com 901-103 Rev G 12/21/06 Canada (FM) Surge protection devices are designed and manufactured by MTL Surge Technologies. A member of the MTL Instruments Group plc FP32 Intrinsically Safe: I/1/A-D, I/O/II C Non incendive: I/2/A-D, I/2/II C TP48 Series Safeguards electronic process transmitters against induced surges and transients from field cabling G Protects 2, 3, and 4 wire transmitters G Easy and direct mounting - simply screws into spare conduit entry G Models for intrinsically safe and flameproof installations available G Parallel connection avoids introduction of any resistance into loop G FM for US and Canada and ATEX approved G 10 year product warranty The TP Series of surge protection devices uniquely provide a level of protection for 2, 3 and 4 wire field-mounted transmitters that is far in excess of the optional transient protection facilities available from the transmitter manufacturers - without involving any additional wiring, conduit modifications or other expensive extras. The TP protection network consists of highpower, solid-state electronics and a gasfilled discharge tube capable of diverting 10kA impulses. The whole unit is encased in an ANSI 316 stainless steel housing, threaded for the common conduit entries used on process transmitters. Versions are available for 1/2” NPT, 20mm ISO, and G1/2” (BSP 1/2 inch) threaded entries. Installation is very simple and can easily be carried out retrospectively to existing installations. The TP is screwed into any unused conduit entry on the transmitter case and flying leads are connected to the terminal block and the internal earth stud. The 3-wire TP protects +ve, -ve and signal. The 4-wire TP protects +ve, -ve, and signal +ve and -ve. They both operate without in any way affecting normal operation - passing ac or dc signals without attenuation while diverting surge currents safely to earth and clamping output voltages to specific levels. The all important earthing connection is made to the local casing of the transmitter with no separate earth connection or ground stake at the transmitter being needed. In operation, the TP makes sure that the transmitter electronics are never exposed to damaging transients between lines or between lines and casing/earth. Any surge current appearing as a series-mode or common-mode transient is converted into a common-mode voltage - whereupon the transmitter electronics are temporarily raised to some higher voltage level before ‘floating’ down automatically (and without damage) to resume normal operation. (explosionproof) operation are available in all gas groups and apparatus temperature classification up to T4 for the TP48 3 & 4 wires and T6 for the TP48. Where transmitters are used in circuits suitable for Div 2/Zone 2 installations, the TP can be added without adversely affecting the level of safety. For fieldbus applications, use the TP32 which meets the requirements of IEC61158-2:2000 and ANSI/ISA-50.02-2 1992 for 31.25kbit/s sytems as used by FOUNDATIONTM Fieldbus, PROFIBUS-PA and WorldFIP. For hazardous-area use, approvals for both intrinsically safe and flameproof Data & Signal Protection Specification (all figures typical at 25°C unless otherwise stated) TP48-3-N & TP 48-4-N TP48-3-I & TP48-4-I TP48-3-G & TP48-4-G 1/2” NPT 20mm ISO (M20 x 1.5) G 1/2” (BSP 1/2”) Weight 175g Dimensions See figure 1 EMC compliance To Generic Immunity Standards EN50082, part 2 for industrial environments Electrical safety EEx ia IIC T4, Ceq=O, Leq=0; the unit can be connected without further certification into any intrinsically safe loop with open circuit voltage <60V and input power <1.2W. EEx d IIC T4; the unit is apparatus-approved to flameproof (explosionproof) standards, and can be fitted into a similarly approved housing. Installation The TP units are designed for mounting directly into an unused conduit entry on a process transmitter housing. Generally, two such entries are provided, one of which is used for the loop wiring. On the unused entry, the blanking plug or other closure device is removed and an appropriately threaded TP screwed into its place. The transmitter specification should provide information indicating the required thread type. TP units can be installed using thread adaptors if necessary, including certified adaptors in hazardous area applications. For applications where two conduit entries are not provided or where both are used for electrical connections, TP units can be housed in conventional conduit hub or junction boxes, provided access to the loop terminals is possible. Figure 2 shows connection details for 3 & 4 Wire process transmitters. Note: In accordance with our policy of continuous improvement, MTL Surge Technologies reserves the right to change the product’s specification without notice. MTL Surge Technologies Power Court, Luton, Bedfordshire, England LU1 3JJ Tel: +44 (0)1582 723633 Fax: +44 (0)1582 483180 E-mail: [email protected] WWW: www.mtlsurge.com A member of the MTL Instruments Group plc (Dimensions across flats 23mm) Figure 1 Dimensions (mm) Figure 2 Connection detail for 3 & 4 wire process transmitters Approvals Country (Authority) Standard No. Certificate/File EC (BASEEFA) EN 50014:1997 + Amendments 1 & 2 BASEEFA04ATEX0251X EN 50020:1994, EN 50284:1999 EC (BASEEFA) EN 50014:1997 + Amendments 1 & 2 BASEEFA04ATEX0053X EN 50018:2000 + Amendment 1 Atex Directive BS EN 50021:1999 TML02ATEX0032X 94/9/EC USA (FM) Class Nos. 3600 (1998), 3610 (1999), 3022293 3611 (1999), 3615 (1989), 3810 incl. Supp 1 (1995-07 (1989-03), ANSI/NEMA 250 (1991), ISA-S12.0.01 (1999) Canada (FM) C22.2 No. 157 C22.2 No. 213 C22.2 No 142 C22.2 No. 94 C22.2 No. 30 3025374 Approved for Product EEx ia IIC T6 (Tamb = -40 to 60°C) EEx ia IIC T5 (Tamb = -40 to 85°C) EEx ia IIC T4 (Tamb = -40 to 60°C) EEx d IIC T6 (Tamb = -40 to 60°C) EEx d IIC T5 (Tamb = -40 to 80°C) EEx d IIC T4 (Tamb = -40 to 85°C) Ex n II T6 (-40°C<Tamb<+60°C) EEx n II T5 (-40°C<Tamb<+85°C) Intrinsically Safe: I, II, III/1/A-G, I/0/IIC Explosionproof: I/1/A-D Non incendive: I/2/A-D, I/2/IIC Dust ignition proof: II,III/1/EFG Special protection: II/2/FG Intrinsically Safe: I, II, II/1/A-G, I/O/IIC Explosionproof: I/1/A-D Nonincendive: I/2/A-D, I/2/IIC Dust ignition proof: II, III/1/EFG Special protection: II/2/FG TP48-X-Y-Z TP48-X-Y-Z TP48-X-Y TP48-X-Y-Z TP48-X-Y-Z To order specify TP48-N-NDI TP48-I-NDI TP48-G-NDI TP48-N TP48-I TP48-G TP48-3-N-NDI TP48-3-I-NDI TP48-3-G-NDI TP48-3-N TP48-3-I TP48-3-G TP48-4-N-NDI TP48-4-I-NDI TP48-4-G-NDI TP48-4-N TP48-4-I TP48-4-G Certified process transmitter surge protection device - 1/2” NPT thread Certified process transmitter surge protection device - 20mm ISO thread Certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) Non-certified process transmitter surge protection device - 1.2” NPT thread Non-certified process transmitter surge protection device - 20mm ISO thread Non-certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) Certified process transmitter surge protection device - 1/2” NPT thread Certified process transmitter surge protection device - 20mm ISO thread Certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) Non-certified process transmitter surge protection device - 1.2” NPT thread Non-certified process transmitter surge protection device - 20mm ISO thread Non-certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) Certified process transmitter surge protection device - 1/2” NPT thread Certified process transmitter surge protection device - 20mm ISO thread Certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) Non-certified process transmitter surge protection device - 1.2” NPT thread Non-certified process transmitter surge protection device - 20mm ISO thread Non-certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) 901-100 Rev G 11/10/05 Maximum surge current 10kA peak current (8/20μs waveform) Leakage current Less than 10μA at maximum working voltage Working voltage 48V dc maximum Bandwidth 1MHz Resistance No resistance introduced into loop Ambient temperature limits -20°C to +60°C (working) -40°C to +80°C (storage) Humidity 5% to 95% RH (non-condensing) Electrical connections TP48 3 flying leads (line 1, line 2 & earth) TP48 3 Wire 4 flying leads (+ve, -ve, signal & earth) TP48 4 Wire 5 flying leads (+ve, -ve, signal +ve, signal -ve, earth) Wire size 32/0.2 (1.0mm2, 18 AWG) Lead length 250mm (minimum) Casing ANSI 316 stainless steel hexagonal barstock, male thread Threads TP-Pipe Series Safeguards electronic process transmitters against induced surges and transients from field cabling G Easy and direct mounting - simply screws into conduit entry G Straightforward and simple installation G Intrinsically safe and flameproof to CENELEC standards G Low impedance series connection avoids signal degradation of the loop G ATEX approved G 10 year product warranty The TP-Pipe Series of surge protection device is a unique unit providing a level of protection for field-mounted transmitters that is far in excess of the optional transient protection facilities available from the transmitter manufacturers - without involving any additional wiring, conduit modifications or other expensive extras. The TP-Pipe protection network consists of high-power, solid-state electronics and a gas-filled discharge tube capable of diverting 10kA impulses. The whole unit is encased in an ANSI 316 stainless steel housing, threaded for the common conduit entries used on process transmitters. Versions are available for 1/2” NPT, 20mm ISO, and G 1/2” (BSP 1/2 inch) threaded entries. Installation is very simple and can easily be carried out retrospectively to existing installations. The TP-P is screwed into the conduit entry on the transmitter case and flying leads are connected to the terminal block and the internal earth stud. Field wiring is connected to a three position socket and then connected to the provided header. They operate without in any way affecting normal operation - passing ac or dc signals without attenuation while diverting surge currents safely to earth and clamping output voltages to specific levels. The all important earthing connection is made to the local casing of the transmitter with no separate earth connection or ground stake at the transmitter being needed. In operation, the TP-P makes sure that the transmitter electronics are never exposed to damaging transients between lines or between lines and casing/earth. Any surge current appearing as a seriesmode or common-mode transient is converted into a common-mode voltage whereupon the transmitter electronics are temporarily raised to some higher voltage level before ‘floating’ down automatically (and without damage) to resume normal operation. For hazardous-area use, approvals for both intrinsically safe and flameproof (explosionproof) operation are available in all gas groups and apparatus temperature classification up to T4. Where transmitters are used in circuits suitable for Div 2/Zone 2 installations, the TP-P can be added without adversely affecting the level of safety. For fieldbus applications, use the TP-P32 which meets the requirements of IEC61158-2:2000 and ANSI/ISA50.02-2 1992 for 31.25kbit/s systems as used by FOUNDATIONTM Fieldbus, PROFIBUS-PA and WorldFIP. Data & Signal Protection Specification (all figures typical at 25°C unless otherwise stated) Maximum surge current 10kA peak current (8/20µs waveform) Leakage current Less than 10µA at maximum working voltage Working voltage 48V dc and 32V dc maximum Bandwidth 1MHz Resistance Loop resistance: 1ohm Ambient temperature limits -40°C to +85°C (-40°F to +185°F) (working) -40°C to +85°C (-40°F to +185°F) (storage) Humidity 5% to 95% RH (non-condensing) Electrical connections Input: 3 position socket/header (max wire Figure 1 Dimensions [mm] 2 #14AWG (2mm ) Output: 3 flying leads (line 1, line 2 & earth) Wire size 32/0.2 (1.0mm2, 18AWG) Lead length 250mm (9.85”) minimum Casing ANSI 316 stainless steel hexagonal barstock,male and female thread Weight 175g Dimensions See figure 1 EMC compliance To Generic Immunity Standards EN50082, part 2 for industrial environments Electrical safety EEx ia IIC T4, Ceq=O, Leq=0; the unit can be connected without further certification into any intrinsically safe loop with open circuit voltage <60V and input power <1.2W. Ex d IIC T4; the unit is apparatus-approved to flameproof (explosionproof) standards, and can be fitted into a similarly approved housing. Installation The TP-Pipe units are designed for mounting directly into the conduit entry on a process transmitter housing. Generally, two such entries are provided, one of which is used for the loop wiring. The transmitter specification should provide information indicating the required thread type. TP-Pipe units can be installed using thread adaptors if necessary, including certified adaptors in hazardous area applications. Figure 2 shows connection details for typical process transmitters. Note: In accordance with our policy of continuous improvement, MTL Surge Technologies reserves the right to change the product’s specification without notice. Figure 2 Connection detail for a typical process transmitter Approvals Country (Authority) Standard No. Certificate/File Approved for Product EC (BASEEFA) EN 50014:1997 + Amendments 1 & 2 BASEEFA06ATEX0034X EEx ia IIC T6 (Tamb = -40 to 60°C) EEx ia IIC T5 (Tamb = -40 to 85°C) TP-P32-X-NDI TP-P48-X-NDI BASEEFA06ATEX0035X Ex d IIC T6 (Tamb = -40 to 60°C) Ex d IIC T5 (Tamb = -40 to 80°C) TP-P32-X-NDI TP-P48-X-NDI MTL06ATEX4832 EEx n II T6 (-40°C<Tamb<+60°C) EEx n II T5 (-40°C<Tamb<+85°C) TP-P32-X-NDI TP-P48-X-NDI EN 50020:1994, EN 50284:1999 EC (BASEEFA) EN 50014:1997 + Amendments 1 & 2 EN 50018:2000 + Amendment 1 Atex Directive 94/9/EC BS EN 50021:1999 TP-P32-X TP-P48-X X = I, N, or G To order specify Fieldbus Applications TP-P-32-N-NDI TP-P-32-I-NDI TP-P-32-G-NDI TP-P-32-N TP-P-32-I TP-P-32-G Certified process transmitter surge protection device - 1/2” NPT thread Certified process transmitter surge protection device - 20mm ISO thread Certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) Non-certified process transmitter surge protection device - 1/2” NPT thread Non-certified process transmitter surge protection device - 20mm ISO thread Non-certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) TP-P-48-N-NDI TP-P-48-I-NDI TP-P-48-G-NDI TP-P-48-N TP-P-48-I TP-P-48-G MTL Surge Technologies Power Court, Luton, Bedfordshire, England LU1 3JJ Tel: +44 (0)1582 723633 Fax: +44 (0)1582 483180 E-mail: [email protected] WWW: www.mtlsurge.com A member of the MTL Instruments Group plc Certified process transmitter surge protection device - 1/2” NPT thread Certified process transmitter surge protection device - 20mm ISO thread Certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) Non-certified process transmitter surge protection device - 1/2” NPT thread Non-certified process transmitter surge protection device - 20mm ISO thread Non-certified process transmitter surge protection device - G 1/2” (BSP 1/2 inch) 901-130 Rev A 11/16/06 Transmitter Applications TP32, TP32-T (Terminator) Series Protects transmitters and smart transmitters from induced surges and transients on fieldbus cabling. G TP32 is a Fieldbus specific surge protector designed to meet the requirements of IEC 61158-2:2000 & ANSI/ISA-50.02-2 1992 G TP32-T includes a TERMINATOR for Fieldbus in addition to surge protection G Easy and direct mounting – simply screws into a spare conduit entry on the transmitter G Parallel connection ensures ‘transparent’ operation - zero voltage drop across device G ATEX approved, Certified FISCO Terminator G 10 year product warranty The TP32 surge protection device is specifically designed to protect process transmitters and devices on Fieldbus systems. The TP32 builds on the high specification of the acclaimed TP48 range to provide a level of surge protection for fieldbus transmitters that is well in excess of the optional transient protection available from some transmitter manufactures. The terminated TP32-T has the same protection circuit as the standard product, but also includes a Foundation Fieldbus termination circuit. This unique combination eliminates the need to purchase and install additional termination circuitry for the FF segment. The TP32-T provides excellent transient protection control and terminates the bus segment in one simple-to-install package. The termination circuit is designed to the requirements described in ANSI/ISA 50.02-2. Note: Two (and only two) terminators are required per bus segment. The all important earth connection is made via the casing of the transmitter negating the need for a separate earth connection or ground stake at the transmitter. In operation, the TP32 makes sure that the transmitter electronics are never exposed to damaging transients between the lines and ground. Any surge current appearing as a series-mode or common-mode transient is converted into a common-mode voltage whereupon the transmitter electronics are temporarily raised to some higher voltage level before ‘floating’ down automatically (and without damage) to resume normal operation. The TP32 protection network is a hybrid design consisting of high-power, solid state electronics and a gas discharge tube which is capable of diverting surges up to 10kA. Encased in an ANSI 316 stainless steel enclosure, the TP32 exhibits unparalleled mechanical durability providing years of maintenance free operation in harsh environments. The enclosure is available threaded for all the common conduit entries. 1 Versions are available for /2” NPT, 20mm ISO, 1 1 and G /2” (BSP /2 inch) threaded entries. adding increased voltage drop across the segment while consistently diverting surge currents safely to ground and clamping output voltages to safe levels. Approvals for intrinsically safe, flameproof/ explosionproof and non incendive operation are available, in all gas groups and apparatus temperature classification up to T6. The TP32 is designed to meet the requirements of IEC 61158-2:2000 and ANSI/ISA-50.022:1992 for 31.25kB/sec systems as used by FOUNDATION Fieldbus, PROFIBUS-PA and WorldFIP. Installation is very simple and can easily be carried out retrospectively to existing installations. By connecting in parallel to the transmitter circuit the TP32 does not interfere with the normal operation of the bus – passing AC or DC signals without Data & Signal Protection Field device protection using TP32 Non Hazardous Installation Install a TP32 on every instrument critical to the operation of the process system. Install TP32 on each instrument with a spur length greater than 50m horizontal and 10m vertical. Critical Instrument For a detailed risk analysis (to minimize the number of protectors required) and guidance for total Fieldbus system protection, please see TAN 1010. Hazardous Area Explosionproof/Flameproof/ Increased Safety Install TP32-X-NDI (where X = thread type) on every instrument critical to the operation of the process. Install TP32-X-NDI on each instrument with a spur length greater than 50m horizontal, 10m vertical. See TAN 1010 for details of total Fieldbus protection. Hazardous Area Intrinsically Safe System; FISCO Install TP32-X-NDI (where X = thread type) on every instrument critical to the operation of the process. Install TP32-X-NDI on each instrument with a spur length greater than 50m horizontal, 10m vertical. See TAN 1010 for details of total Fieldbus protection. NOTE: The TP32 NDI is FISCO compatible. NOTE: Protection at the host end of the trunk is mandatory, see FP32 datasheet and TAN 1010 for more information. Use of the TP32-T to terminate a Fieldbus trunk Conventional Installation Junction block and terminator are required at the far end of a Fieldbus trunk. Installation Using TP32-T Use of TP32-T eliminates the need for an extra junction block and terminator. Terminator Why Use a TP32-T TERMINATOR? N Saves the expense of extra junction blocks and terminators. N Saves time during installation N Provides the correct termination of a Fieldbus trunk with the added benefit of high performance surge protection. Specification All figures typical at 25°C (77°F) unless otherwise stated EEx ia IIC T4, Ceq=0, Leq=0; the unit can be connected into any FISCO application with the following input parameters Pi=5.32W. EEx d IIC T6; the unit is apparatus-approved to explosionproof (flameproof) standards, and can be fitted into a similarly approved housing. Figure 1 Dimensions Figure 2 Connection detail for a typical transmitter Approvals Country (Authority) Approved for Product EC (BASEEFA) EN 50014:1997 + Amendments 1 & 2 BASEEFA04ATEX0251X EN 50020:1994, EN 50284:1999 EEx ia IIC T6 (Tamb = -40 to 60°C) EEx ia IIC T5 (Tamb = -40 to 85°C) EEx ia IIC T4 (Tamb = -40 to 60°C) TP32-N-NDI TP32-I-NDI TP32-G-NDI EC (BASEEFA) EN 50014:1997 + Amendments 1 & 2 BASEEFA04ATEX0053X EN 50018:2000 + Amendment 1 EEx d IIC T6 (Tamb = -40 to 60°C) EEx d IIC T5 (Tamb = -40 to 80°C) EEx d IIC T4 (Tamb = -40 to 85°C) TP32-N-NDI TP32-I-NDI TP32-G-NDI Atex Directive BS EN 50021:1999 94/9/EC Ex n II T6 (-40°C<Tamb<+60°C) EEx n II T5 (-40°C<Tamb<+85°C) TP32-N TP32-I TP32-G Note: In accordance with our policy of continuous improvement, we reserve the right to change the product’s specification without notice. MTL Surge Technologies Power Court, Luton, Bedfordshire, England LU1 3JJ Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283 E-mail: [email protected] WWW: www.mtlsurge.com A member of the MTL Instruments Group plc Certificate/File TML02ATEX0032X USA (FM) Class Nos. 3600 (1998), 3610 (1999), 3022293 3611 (1999), 3615 (1989), 3810 incl. Supp 1 (1995-07 (1989-03), ANSI/NEMA 250 (1991), ISA-S12.0.01 (1999) Intrinsically Safe: I, II, III/1/A-G, I/0/IIC Explosionproof: I/1/A-D Non incendive: I/2/A-D, I/2/IIC Dust ignition proof: II,III/1/EFG Special protection: II/2/FG TP32-N-NDI TP32-I-NDI TP32-G-NDI Canada (FM) C22.2 No. 157 C22.2 No. 213 C22.2 No 142 C22.2 No. 94 C22.2 No. 30 Intrinsically Safe: I, II, II/1/A-G, I/O/IIC Explosionproof: I/1/A-D Nonincendive: I/2/A-D, I/2/IIC Dust ignition proof: II, III/1/EFG Special protection: II/2/FG TP32 All Installation The TP32 is designed for mounting directly into an unused conduit entry on a fieldbus transmitter housing (see figure 2). Generally, two such entries are provided, one of which is used for the bus wiring. On the unused entry, the blanking plug or other closure device is removed and an appropriately threaded TP32 screwed into its place. The transmitter specification should provide information indicating the required thread type. TP32 units can be installed using thread adaptors (such as a tee piece) if necessary, including certified adaptors in hazardous area applications. For applications where two conduit entries are not provided or where both are used for electrical connections, TP32 units can be housed in conventional conduit hub or junction boxes, provided access to the loop terminals is possible. Standard No. 3025374 To order specify TP32-N, TP32-T-N TP32-N-NDI, TP32-T-N-NDI TP32-I, TP32-T-I TP32-I-NDI, TP32-T-I-NDI TP32-G, TP32-T-G TP32-G-NDI, TP32-T-G-NDI 1 / ” NPT thread ” NPT thread, with EEx ia, EEx d, approval 20mm ISO thread 20mm ISO thread, with EEx ia, EEx d, approval 1 1 G /2” (BSP /2 inch) 1 1 / G 2” (BSP /2 inch), with EEx ia, EEx d, approval 2 1 / 2 901-114 Rev D 11/9/05 Maximum surge current 10kA peak (8/20μs waveform) Leakage current Line-line: < 1μA at working voltage Line-earth: < 1μA at 120V common-mode Working voltage ±32V dc maximum ±120V peak (or DC) maximum common-mode Maximum continuous operating voltage 35V Limiting voltage Line-line with 250mm cable: < 49V (10A, 10/1000μs pulse) Line-earth with 75mm cable: <635V (3kA, 8/20μs waveform) <635V (6kV, 1.2/50μs waveform) Line resistance No resistance introduced into the loop Capacitance Line-line: < 50pF Line-earth: < 100pF Terminator (TP32-T only): 100 ohm, 1μF Attenuation 7.8KHz–7.5MHz monotonic & better than –1dB typical bandwidth, 150MHz on 100Ω system Ambient temperature limits T6 –40°F to +140°F (–40°C to +60°C) T5 –40°F to +185°F (–40°C to +85°C) Humidity 5% to 95% RH (non-condensing) Electrical connections 3 flying leads: line 1 & line 2 plus non-polarised earth Wire size: 32 / 0.2 (1.0mm2, 18 AWG) Lead length: 250mm minimum supplied ≤ 75mm recommended Casing ANSI 316 stainless steel hexagonal barstock, male thread Threads 1 / ” 2 NPT TP32-N TP32-I 20mm ISO (M20 x 1.5) 1 1 TP32-G G /2” (BSP /2 inch) Weight 175g (6.18oz) Dimensions See figure 1 ATEX compliance See Approvals table for details EMC compliance BS EN 61643-1 Electrical Safety EEx ia IIC T6, Ceq=0, Leq=0; the unit can be connected without further certification into any intrinsically safe loop with open circuit voltage <30V and input power <1.2W.