* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Radio Telemetry System
Buck converter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Wireless power transfer wikipedia , lookup
Opto-isolator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Mains electricity wikipedia , lookup
Regenerative circuit wikipedia , lookup
RADIO TELEMETRY SYSTEM FOR STRAIN GAGES, THERMOCOUPLES, AND VOLTAGE SIGNALS TX20B RX20B-M, receiver with display, $2350, with TX20B-S1, strain gage module, $1950, and TX-BCA-100, clamp assembly, $1250, shown smaller than actual size. Complete System 5550 $ See S Selectioection Y for a Technic n of Scientific al, , Books A and Reference vailable omega.c from om SM Extended Warranty Program ⻬ Eliminates Cumbersome Slip Ring Installation ⻬ Does Not Require FCC License ⻬ Small, Lightweight ⻬ Wireless Sensor Interface ⻬ Battery-Powered or Induction-Powered Models Available OMEGA’s TX20B radio telemetry system is ideal for transmitting signals from sensors that are mounted on rotating shafts. The TX20B Series miniature transmitters modulate sensor signals from thermocouples, voltage transducers, or strain gage bridge circuits onto an RF carrier and transmit them to a stationary receiver. The RX20B receiver demodulates the signals and converts them into ±2V analog output. Two analog output signals are available simultaneously. A wideband output provides frequency response from DC to 1250 Hz. For maximum stability of the signal, a filtered output is also available with a 0 to 10 Hz bandwidth. TX20B transmitters incorporate a crystal oscillator that is tuned to a specific frequency, eliminating the C-41 OMEGACARESM extended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARESM covers parts, labor and equivalent loaners. need for tuning by the operator. Transmitter frequencies can be staggered, allowing multiple transmitters to operate in proximity with no interference. Multichannel receivers are available. Transmitters are small enough to be taped or strapped to the rotating shaft, and they can be powered by a 9V battery. For applications in which continuous uninterrupted monitoring is necessary, an inductively coupled power supply and transmitter are also available. The TX20B operates in a band that does not require an FCC license. RADIO TELEMETRY SYSTEM ORDERING GUIDE AND SPECIFICATIONS SYSTEM SPECIFICATIONS Accuracy: ±0.25% FS Non-Linearity: ±0.1% FS Repeatability: ±0.05% FS Modulation Type: FM RECEIVER SPECIFICATIONS Frequency Response: Wideband, DC to 1250 Hz; filtered, DC to 10 Hz Output Ripple: Wideband, <15 mV; filtered, <5 mV Dimensions: 89 H x 211 W x 203 mm L (3.5 x 8.3 x 8") To order typical batterypowered system: 1. Select transmitter module 2. Select clamp assembly with 9V battery housing 3. Select receiver To order typical inductionpowered system: 1. Select transmitter module 2. Select clamp assembly with built-in induction power supply circuitry 3. Select stationary loop induction power supply 4. Select receiver for use with stationary loop induction power supply Recommended Reference Book: Classical Feedback Control with MatLab, CM-4356, $93. See Section Y For Additional Books To Order (Specify Model Number) TRANSMITTER MODULES MODEL NO. INPUT RANGE DESCRIPTION PRICE TX20B-S1 0.3 mV/V Strain gage transmitter $1950 TX20B-S2 1.0 mV/V Strain gage transmitter 1950 TX20B-S3 2.0 mV/V Strain gage transmitter 1950 TX20B-S4 3.0 mV/V Strain gage transmitter 1950 TX20B-E1 0.1V Voltage transmitter 1950 TX20B-E2 1.0V Voltage transmitter 1950 TX20B-E3 5.0V Voltage transmitter 1950 TX20B-E4 10.0V Voltage transmitter 1950 TX20B-J1 -17 to 93°C (0 to 200°F) Type J T/C transmitter 1950 TX20B-J2 -17 to 204°C (0 to 400°F) Type J T/C transmitter 1950 TX20B-J3 -17 to 427°C (0 to 800°F) Type J T/C transmitter 1950 TX20B-J4 -17 to 538°C (0 to 1000°F) Type J T/C transmitter 1950 TX20B-K1 -17 to 260°C (0 to 500°F) Type K T/C transmitter 1950 TX20B-K2 -17 to 538°C (0 to 1000°F) Type K T/C transmitter 1950 TX20B-K3 -17 to 816°C (0 to 1500°F) Type K T/C transmitter 1950 TX20B-K4 -17 to 1093°C (0 to 2000°F) Type K T/C transmitter 1950 CLAMP ASSEMBLIES BATTERY POWER PRICE INDUCTIVE PRICE DESCRIPTION mm (in) TX-BCA-100 $1250 TX-ICA-100 $1190 Clamp assembly for 25.4 (1) shafts TX-BCA-125 1250 TX-ICA-125 1190 Clamp assembly for 31.8 (11⁄4) shafts TX-BCA-150 1250 TX-ICA-150 1190 Clamp assembly for 38.1 (11⁄2) shafts TX-BCA-175 1250 TX-ICA-175 1190 Clamp assembly for 44.5 (13⁄4) shafts TX-BCA-200 1250 TX-ICA-200 1190 Clamp assembly for 50.8 (2) shafts TX-BCA-250 1250 TX-ICA-250 1190 Clamp assembly for 63.5 (21⁄2) shafts TX-BCA-300 1250 TX-ICA-300 1190 Clamp assembly for 76.2 (3) shafts TX-BCA-400 1300 TX-ICA-400 1190 Clamp assembly for 101.6 (4) shafts TX-BCA-500 1300 TX-ICA-500 1190 Clamp assembly for 127.0 (5) shafts TX-BCA-600 1300 TX-ICA-600 1190 Clamp assembly for 152.4 (6) shafts RECEIVERS MODEL NO. DESCRIPTION PRICE RX20B-M Receiver for battery-powered systems $2350 RX20B-I-M Receiver for induction-powered systems 2540 SL20 Stationary loop for induction-powered systems 1890 RX24B-BP 4-channel plug-in receiver backplane 1950 RX28B-BP 8-channel plug-in receiver backplane 2600 RX22 Plug-in receiver module (battery transmitter) 1575 RX22-I Plug-in receiver module (induction transmitter) 1875 Comes complete with 9V battery and operator’s manual. Ordering Example: TX20B-J1 + TX-BCA-100 + SL20 + RX20B-I-M, complete inductionpowered system for 1" shafts for -17 to 93°C (0 to 200°F) Type J thermocouple, $1950 + 1250 + 1890 + 2540 = $7630. C-42 ACCESSORIES TRANSMITTER SPECIFICATIONS Input Types: 120 Ω to 1 kΩ strain gage bridge, DC voltages, J or K thermocouples Bridge Excitation: 5 Vdc (strain gage only) Power Source: 9V battery (included) or induction power Operating Temp: -40 to 130°C (-40 to 266°F) Zero Temp Drift: 0.02%/°C Span Temp Drift: 0.02%/°C Dimensions: 37.5 W x 20.3 H x 17.3 mm D (1.48 x 0.80 x 0.68") CUSTOM-BUILT TO ORDER C One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | [email protected] www.omega.com UNITED KINGDOM www. omega.co.uk Manchester, England 0800-488-488 UNITED STATES www.omega.com 1-800-TC-OMEGA Stamford, CT. FRANCE www.omega.fr Guyancourt, France 088-466-342 CANADA www.omega.ca Laval(Quebec) 1-800-TC-OMEGA CZECH REPUBLIC www.omegaeng.cz Karviná, Czech Republic 596-311-899 GERMANY www.omega.de Deckenpfronn, Germany 0800-8266342 BENELUX www.omega.nl Amstelveen, NL 0800-099-33-44 More than 100,000 Products Available! Temperature Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire Flow and Level Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters pH and Conductivity Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation Data Acquisition Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers Pressure, Strain and Force Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves Heaters Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters click here to go to the omega.com home page EPG05