Download OM-128HH - Rural Energy Enterprises

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Lumped element model wikipedia , lookup

Thermostat wikipedia , lookup

Transcript
Introducing
THE
OM-128HH
ON-DEMAND
• Complements the highest efficiency, aquastatic controlled, boilers that use low water temperatures.
• Internal thermostat control circuitry allows unit to communicate to zone valve or boiler controller an exclusive feature that no other convector has!
HYDRONIC HEATER
• Easy to use LED display panel with built in thermostat that instructs boiler when zone should come
on or off based on homeowners desired comfort requirement.
• Variable fan speed maximizes operating efficiency and fuel savings.
COMPACT
LOW-MASS WATER HEATER WITH
• Benefit of both radiant heat and convective heat.
87% AFUE EFFICIENCY SAVES CUSTOMERS
• Whisper quiet fan efficiently distributes heat evenly throughout the home.
AS MUCH
OR MORE THAN THE LEADING
• Heats an area of 300 to 1,000 square feet (heat output of 3,000 BTU per hour on low setting to
CAST 20,200
IRON BOILERS,
ATonHALF
BTU per hour
high). THE SIZE!
• Saves valuable wall space, replacing up to 37 feet of baseboard*.
• Can be installed in less than half the time of baseboard.
• 10-year heat exchanger limited warranty.
*Baseboard length calculated based on 550BTU/ft.
COOLING - HEATING PRODUCTS
Toyotomi Oil Miser OM-128HH SPECIFICATIONS
Model:OM-128HH
Type: Combustion:
Venting:
Heating System:
Purpose:
Oil Pressure Vapor
Forced Flue / Chimney Vent
On Demand
Hydronic Heating (1)
Ignition:
High Voltage Discharge Spark
Fuels:
No. 2 or No. 1 Low Sulfur Fuel Oil ASTM D396,
Ultra-Low Sulfur Diesel (ULSD) ASTM D975,
1-K Kerosene ASTM D3699
AFUE Efficiency:
87.1%
Hot Water Input:
148‚000 BTU/h
Hot Water Output:
128,900 BTU/h
Maximum Water Temperature: 176° F (approximately)
Water Flow Rate/
Temperature Rise:
6.2 gal./min (40° F rise)
4.1 gal./min (60° F rise)
3.1 gal./min (80° F rise)
Fuel Consumption:
1.05 gal/h
THE
Capacity of Heat Exchanger: 5.10 gal
Fuel System:
External tank (2) Gravity Fed
Dimensions (W x H x D):
12-5/8’’ x 27-3/4’’ x 22-1/2’’
Weight:
77 lbs. Empty
Electrical Rating:
120 Volts AC, 60 Hz
Ignition - 120W
Burning - 98W
OM-128HH
Required Accessories:Fuel filter, Flue pipe installation kit (Part #20476440) or Chimney installation
adapter kit (Part #20476430 – 5 inch kit or #20476415 – 4 inch kit)
Safety Device:Over-heat protector, Ignition safety device, Heat exchanger bi-metal switch,
Dual-Temperature fuse, Fusible link valve
Temp. Differential Setting:
3.6° F, 18° F, or 36° F (3 setting selector switch)
Nozzle: Quantity of Vapor:
Spraying Angle:
Spray Pattern:
0.85 GPH
60°
Delavan Type XA
Temperature Fuse:
282° F
TOYOTOMI USA, INC.
604 FEDERAL ROAD, BROOKFIELD, CT 06804
203-775-1909 WWW.TOYOTOMIUSA.COM
Electric Current Fuse:5 A,
7A (for external circulation pump or accessory)
(1) Check state and local codes/ordinances for permitted use.
Can also supply domestic hot water provided it is used with indirect storage tank.
(2) External tank to be purchased from local suppliers.
B1400029