* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Slajd 1
Standby power wikipedia , lookup
Electrical ballast wikipedia , lookup
Wireless power transfer wikipedia , lookup
Three-phase electric power wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Ground (electricity) wikipedia , lookup
Current source wikipedia , lookup
Power factor wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Electrical substation wikipedia , lookup
Audio power wikipedia , lookup
Stray voltage wikipedia , lookup
Power inverter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Electric power system wikipedia , lookup
Electrification wikipedia , lookup
Life-cycle greenhouse-gas emissions of energy sources wikipedia , lookup
Power over Ethernet wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power MOSFET wikipedia , lookup
History of electric power transmission wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Distribution management system wikipedia , lookup
Power engineering wikipedia , lookup
Earthing system wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
Surge protector wikipedia , lookup
Power supply wikipedia , lookup
Alternating current wikipedia , lookup
PA DE O FM RTMEN ARINE EL N IC O R T C E SPICE modelling of PFC controller Krzysztof Górecki, Janusz Zarębski Department of Marine Electronics Gdynia Maritime University, POLAND T S Outline Introduction Structure and principle of operation of the device UC3853 Model of the device UC3853 Results Conclusions 2 Introduction (1) Switched mode power supplies commonly used in electronic installations cause changes for worse of the quality of energy in the line. This phenomenon results from the fact that switched mode power supplies absorb a current from the line in the pulses form. Power supplies can be treated as the nonlinear RLC load of the line and the power consumed by switched mode power supplies comprises: active and reactive powers. The second quality of energy influences disadvantageously the operation of many installations connected to the power network, e.g. electrical machines, causing an additional increment of their winding temperature. 3 Introduction (2) The important parameter characterizing the electrical installation influencing the electrical energy quality is the power factor (PF). To obtain a high value of PF, a switched mode power supply input current should be formed in such a way as to get the sinusoidal course of current synchronized with the course of the line voltage. To get the proper shape of the input current, special circuits of power factor correction (PFC) are used. 4 Introduction (3) Currently, the predominant role is played by active PFC consisting of dc-dc converters and special integrated circuits working as a PFC controller. Today, a lot of concerns offer such circuits, that realize different algorithms of power factor corrections. Designing and analysing electronic circuits demand the use of credible models of circuit elements, acceptable by the proper software, e.g. SPICE. There is no information about the models of PFC controllers for SPICE. 5 In the paper In this paper the authors present a new model of a PFC controller realizing the control of the average value of current. For the considerations the device UC3853 (Texas Instruments) has been chosen. 6 Structure and principle of operation of the device UC3853 IAC IMO ICOMP REF VCC 7.05 V/7 V VCOMP EA MULT FB CA COMP FF R Q X2 3V OVP 3.9 kW VCC/8 OS OUT S 15 V GND 3.15 V/3 V SYNC 11.5 V/9.5 V SYNC OSC The considered device consists of nine blocks enabling the control of the average value of the input current and the output voltage as well as two protection blocks. The control of the current and voltage is realized by the error amplifier (EA), the multiplier (MULT), the squaring circuit (X2), the current amplifier (CA), the PWM comparator (COMP), the oscillator (OSC), the RS flip-flop (FF) and the output stage (OS). The device also includes the blocks protecting the overvoltage at the device output and too low value of the supply voltage. 7 Model of the device UC3853 Vcomp IMO IAC ICOMP 60 Riac G1 4 Rwp Gmn R1 icomp1 1 E_pwm VCC FB E_ovp ovp 50 E_wp 21 E_kw R2 2 Vosc Rout E_inwr 3 Vosc1 7 E_inw OUT 8 E_and •The model of the device UC3853 has developed according to the principles of formulating integrated circuits models for SPICE and the catalogue data. •The presented model consists of 2 controlled current sources, 6 controlled voltage sources, 2 independent voltage sources, 5 resistors and 2 NAND gates. •The detailed description of the sources efficiency – see proceedings 8 Results (1) The tested switched-mode power supply containing the controller UC3853 DBP Iin L DD01 DD02 LF CF Vin DD03 N2 CIN RAC1 RM0 IAC RCZ 7 VCOMP RVC 8 FB CVC CVCZ UC 3853 6 IMO CCZ Q C0 Vout R0 RB1 RVI1 RAC2 5 ICOMP DFF RS DD04 CCP DOUT RQ RB2 1 VCC 2 OUT 3 GND 4 RVI2 DQ DM0 CFF2 CFF1 RVD2 RVD1 9 Results (2) Vin = 150 V 3 450 400 1 350 -1 Iin [A] Vout [V] 300 250 200 -3 -5 150 100 -7 50 -9 0 0 0,04 0,08 0,12 t [s] 0,16 0,2 0 0,04 0,08 0,12 0,16 0,2 t [s] •The nominal value of Vout is 130 ms after switching on this device •The input current is sinusoidal, but its amplitude is changing with time. In the steady state, this amplitude slightly exceeds 1 A 10 Results (3) Vin = 310 V 2 400 0 350 -2 300 -4 Iin [A] Vout [V] 450 250 200 150 -6 -8 -10 -12 100 -14 50 -16 0 0 0,04 0,08 0,12 t [s] 0,16 0,2 0,24 -18 0 0,04 0,08 0,12 0,16 0,2 0,24 t [s] •The results of switching-on the overvoltage protection circuit at the beginning of the power supply operation is shown. •Not before reaching 110 ms, the power supply input current is of the desirable sinusoidal form. •In the steady state the measured characteristics are qualitatively similar to the calculated ones 11 Conclusions In the paper the new SPICE model of the monolithic PFC controller UC3853 is proposed. The results of the analysis of the power supply with this PFC device, confirm the correctness of the model. The presented results of the analysis confirm the proper description of all the blocks of the device responsible for regulation of the output voltage and the input current of the device as well as the overvoltage protection circuit. The model can be useful for designers of power supply systems, especially such systems with the PFC circuit. In spite of the fact that the model was investigated for the device UC3853 only, it can be used for other PFC controllers based on the conception of controlling the current average value. The drawback of the model is long time of an analysis to get the steady state, which can reaches even a few hours In further investigations the authors will elaborate a special algorithm, which will enable shorting the analysis of the considered class of the 12 power supply systems.