* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Analyzing the forces within transtibial prosthetic sockets and design
Buck converter wikipedia , lookup
Current source wikipedia , lookup
Portable appliance testing wikipedia , lookup
Automatic test equipment wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
Phone connector (audio) wikipedia , lookup
AC power plugs and sockets wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
Industrial and multiphase power plugs and sockets wikipedia , lookup
Analyzing the forces within unilateral transtibial prosthetic sockets and design of an improved force minimizing socket Christine Bronikowski, Amanda Chen, Jared Mulford, Amy Ostrowski Advisor: Aaron Fitzsimmons, The Surgical Clinic Problem Statement • Lack of research in the socket interface between the artificial limb and the residual limb, specifically force profiles ▫ Majority of research based on models with historically proven success and qualitative assessments Current Process for Constructing a Transtibial Socket 1. Transtibial Patient Evaluation a. Limb measurements b. Skin type and integrity c. Range of motion d. Hand dexterity e. Fine and gross motor skills f. Cognition 2. Gel Liner Interface Material Selection a. Most common: Urethane, thermoplastic elastomer, silicone 3. Fit Gel Liner to Patient Current Process for Constructing a Transtibial Socket (cont.) 4. Cast and measure over gel liner 5. Modify negative model a. Computer modeling b. Hand modification 6. Fabricate positive check socket 7. Fit positive check socket – static and dynamic assessments 8. Fit final laminated socket Current Socket Designs Designed on a case-by-case basis for individual patients Problems with Current Models ▫ Skin abrasion ▫ Pain or discomfort ▫ Tissue breakdown at the skin surface and within deep tissues ▫ Pressure ulcerations and resultant infections at the socket interface Many of these problems arise from forces at prosthetic interfaces Project Goals • Acquire accurate measurements of perpendicular forces acting on the residual limb of transtibial amputee during various movements • Pinpoint regions with highest forces • Design a socket system in which forces are optimally distributed throughout the residual limb-socket interface • Increase overall patient comfort Forces Acting on the Limb • Shear– resulting from frictional forces between skin and socket ▫ Can be minimized using socket liners • Perpendicular Method of Force Analysis • Force Sensing Resistor (FSR) placed between liner and socket • Very thin– will not cause variation in force determination • Decrease in resistance with increasing force, which leads to increasing output voltage Circuit Design Circuit design: current to voltage converter Vout=Vref*(-RG/RFSR) QuickTime™ and a TIFF (Uncompressed) decompressor are needed to see this picture. Circuit Design Placement of FSRs • Impractical to cover every area of the residual limb with sensors • One FSR used in each area of clinical interest, 9 total Pressure Tolerant •Patellar tendon •Medial tibial flare •Mid shaft of fibula •Medial tibial shaft Pressure Sensitive •Distal end of tibia •Distal end of fibula •Fibular head •Anteromedial tibia •Hamstring tendons Design/Safety Considerations • Wire thickness ▫ Thin enough to prevent interference with force data ▫ Thick enough to remain durable during movement • FSR-wire connection ▫ Must not break during testing • Transportability ▫ Must move from treadmill to ramp area quickly • Power Supply Preliminary Trial at The Surgical Clinic Recent Work • Alterations based on the preliminary test ▫ FSRs reinforced with nonconductive epoxy ▫ Circuit rebuilt ▫ Transportable Encasement • Prosthetic leg testing • Voltage calibration • Drift correction • NI LabVIEW / RIO Current Status • • • • Preparing to test with Cody on Friday, Feb. 11th Developing LabVIEW module to record data Attempting to get in contact with Dr. Robinson Calibrating Voltage – Force curve Future Work • Conduct trials with additional patients ▫ Test on multiple surfaces (incline, flat, stairs) • Analyze results, determine regions containing peak forces • Test several different types of sockets with Cody • Design and develop new socket: provide more cushioning in areas of greatest force • Determine success from patient feedback and peak force reduction in critical regions References Engsberg, J.R., Springer, M.J.N., and J.A. Harder. (1992). Quantif ying interface pressures in below-knee-amputee sockets. J Assoc Child Prosthet Orthot Clin 27(3), 81-88. Houston, V. L., Mason, C.P., LaBlanc, K.P., Beattie, A.C., Garbarini, M.A., and E.J. Lorenze. Prelim ary results with the DVA-Tekscan BK prosthetics socket: residual lim b stress measurement system. In: Proceedings fo the 20t h Annual Meeting American Academy of Orthotist and Prosthetist, Nashvill e TN. P 8-9 Jendrzejczyk, D. J. (1985). Flexible Socket Systems. Cli n. Prosthet. Orthot. 9 (4), 27-31. Lee, W.C., and M. Zhang. Using computational simulation to aid in the prediction of socket fit: a prelimi nary study. Med Eng Phys. 2007 Oct;29(8):92 3-9. Polli ack, A.A., Sieh, R.C., Craig, D.D., Landsberger, S., Mcneil , D.R., and E. Ayyappa. Scientifi c vali dation of two commercial pressure sensor systems for prosthetic socket fit. Prosthetics and Orthotics International, 2000, 24, 63-73. Sanders, J.E., Daly, C.H., and E.M. Burgess (1993). Cli nical measurement of normal shear stresses on a transtibial stump: Characteristics of wave-form shapes during walking. Prosthet Orthot Int 17, 38-48.