Battery backup enable/disable (Link PLK2) Available on NC942B controllers only NC942/NC942B Link PLK2 enables or disables the call controller’s 500mAHr rechargeable battery Fit!to backup facility. Note that this facility is available on NC942B call controllers only. Enable battery When enabled (link PLK2 fitted), the NC942B’s onboard battery backup supply PLK2 will continue to power the system for approximately 24 hours (standby) plus 15 minutes (alarm running time) in the event of a mains failure. This will be indicated by the controller’s ‘ON’ LED flashing green approximately once per second. One Zone Call Controller Should the mains supply remain disconnected for a prolonged period of time, the battery backup facility will automatically shutdown to prevent the batteries from deep discharge. The default setting for Link PLK2 is link not fitted/battery disabled. This is to conserve battery life and ensure the safety of the controller during storage/transit. Note that the shorting link required to enable the facility is provided in the controller’s accessory pack. Sounder and LED test facility Pressing the controller’s RESET button when link PLK1 is fitted in the Reset (a) position will make its sounder and alarm LED activate. When released, the LED and sounder will switch off. ! This equipment must be installed and maintained by a suitably skilled and technically competent person. This Call Controller is a piece of Class 2 equipment. However, any metal parts used during installation (i.e. metal back box) MUST be earthed. The earth termination point on the One Zone Call Controller is provided for installer convenience only and, as such, should only be used if an earth connection is not required elsewhere. BASIC OPERATION The green power 'ON' indicator indicates that the call controller is powered up. When a standard call is triggered at any device connected to the controller (see figure 1), the controller’s sounder will generate a constant tone and its red 'CALLING' LED will illuminate. The call controller’s relay will also activate and any external equipment connected to the controller’s relay contacts (see page 3) will operate as configured. Depending on how Link PLK1 has been configured (see page 3), pressing the controller’s 'RESET' button will (a) reset the call (b) mute the call or (c) have no effect. (Note that standard calls can also be cancelled at the device that originated the call if it has a reset facility or via a remote reset point). If an emergency call is triggered on a device connected to the controller, the call controller’s sounder will pulse and its red 'CALLING' LED will flash. The controller’s relay will also pulse and any external equipment connected to the controller’s relay contacts (see page 3) will operate as configured. Note that emergency calls override standard calls and can only be reset at the device from which they were generated. GENERAL TECHNICAL SPECIFICATION Mains supply: Output: Indicators: Sounder: Controls: IP Rating: Dimensions: Voltage: 230V a.c.; Max current: 23mA; Frequency: 50Hz. Voltage: 12V d.c.; Current: 140mA; Volt-free relay contacts (NO/C/NC) rated at 30V d.c. @ 1A Red alarm present LED; Green supply present LED (flashes green on NC942B model only when battery back up is active) Active in alarm. ‘RESET’ Button (link selectable for reset, mute or no function). IP31 when correctly installed. 147 x 87 x 39mm (WxHxD). Mounts on 25mm UK double gang back box. © 2005. Approved Document No: DNU0942000 Rev 1. We reserve the right to alter product specifications at our discretion and without prior notice. Errors and omissions excepted. This manual has been carefully checked prior to publication. However, no responsibility can be accepted by the manufacturer or distributors of this equipment for any misinterpretation of an instruction or guidance note or for the compliance of the system as a whole. The NC942 is a one zone call controller with a built-in mains to regulated 12V d.c. 140mA power supply. Its features include a volume adjustable sounder, a link-selectable mute/reset button, a Power ‘ON’ LED, an Alarm ‘CALLING’ LED and a volt-free relay output (for optional interfacing to externally powered beacons, strobes or other ancillary devices). It also features a Braille text label for ease of use by the visually impaired. The NC942B call controller includes all of the above plus an additional on-board rechargeable battery backup facility providing up to 24 hours standby and 15 minutes alarm running time. Both controllers are fully compatible with our entire range of 800 Series Call System components, making them ideal for virtually all single zone applications including disabled persons toilet alarms. I N S T A L L A T I ON I N S T R U C T I O N S Approved Document No: DNU0942000 Rev 1 • Page 1 of 4 INSTALLATION ENGINEER SELECTABLE FUNCTIONS ALWAYS ENSURE THE MAINS SUPPLY IS ISOLATED BEFORE MAKING ANY CONNECTIONS. Figure 2 : Rear view of the NC942/NC942B Call Controller The call controller should be sited internally on a standard UK double gang back box (minimum depth 25mm) in an area where it is readily accessible by the person(s) designated to use it. The area should be clean and dry and the ambient light and sound levels should allow the status of the indicators and internal sounder to be seen and heard. Any likelihood of tampering or vandalism should also be taken into account. Reset Volume VR1 CONN2 Figure 1 : Example NC942/NC942B Call Controller Wiring NEGATIVE Three cores of four core stranded burglar alarm cable Mute PLK1 L RECHARGEABLE BATTERY BACKUP SUPPLY COVER N NC942B MODEL ONLY SIGNAL CONN3 RLY1 Fit to Enable PLK2 battery +VE SIGNAL -VE NO C NC POSITIVE Spr Sig -Ve Sig -Ve +Ve RESET ON F U S E Sig -Ve CALL Reset button operation ALERT Call Call NC942/NC942B Call Controller 1mm2 T&E RESET CALLING RESET 3A Switch Fused Spur +Ve NC806CS Overdoor Light c/w Sounder Call NC809DBB Reset NC802DEB-1/2 NC807C Ceiling Pull Point c/w Sounder Emergency Call Point A maximum of five 800 Series devices (ceiling pulls, call points, overdoor lights, reset points, etc.), can typically be connected to the call controller. Always refer to the installation instructions supplied with each device before installation Mains wiring The general requirement for the mains supply to the call controller is fixed wiring, using three core cable of not less than 1mm2. This should be fed from an isolating switched fused spur, fused at 3A, which is marked appropriately and secure from unauthorised operation. Live and neutral should be connected to the controller’s L and N terminals respectively. If a plastic back box is used, make the earth connection to the terminal marked at connector block CONN2. If a metal back box is used, the earth connection must be made to back box’s earth bonding point. All external wiring brought into the unit must be adequately insulated with PVC or Neoprene. (Link PLK1) Link PLK1 allows the call controller’s on-board RESET button to be set up to:- CONN2 L N (a) Reset the system In this position, pressing the controller’s RESET button when a standard call is active will return the controller to its normal state. (b) Mute the system In this position, pressing the controller’s RESET button when a standard call is active will mute the controller’s on-board sounder. (c) Have no effect In this position (no link fitted), pressing the controller’s RESET button when a standard call is active will have no effect. ! Reset!!!!!!!!!!!!!!!Mute Reset!!!!!!!!!!!!!!!Mute Reset!!!!!!!!!!!!!!!Mute Many authorities insist that a call system’s reset function is carried out at ‘point of source’ (i.e. in the room in which the call was made). This is to ensure that the person who raised the alarm is visited. As such, the default setting for Link PLK1 is link not fitted/no effect. Volume control (Potentiometer VR1) All mains wiring should be provided in accordance with the current edition of the IEE Wiring Regs (BS 7671) or in accordance with the relevant national wiring rules. Potentiometer VR1 can be used to adjust the level of the call controller’s on-board sounder. Turning the control clockwise with a terminal screwdriver will increase the volume, turning it anti-clockwise will decrease it. Extra low voltage (ELV) wiring On-board volt-free relay operation Four core stranded burglar alarm cable is ideal for the extra low voltage wiring on most installations. The call controller includes an on-board volt-free relay with normally open (NO), normally closed (NC) and common (C) contacts. The relay contacts are rated at 30Vd.c. @ 1A and can be used to switch optional externally powered devices such as sounders, strobes or the extra low voltage coils of mains controlling relays. All extra low voltage wiring must be carefully planned before starting the job. Always segregate extra low voltage wiring from the mains wiring. In the event of a short circuit on the extra low voltage wiring, an internal self-resetting fuse will temporarily isolate the system until the fault is cleared. The Call Controller is also protected by a non-serviceable thermal fuse in its transformer winding which will blow if there is a serious malfunction. If this happens, return the controller for repair. Approved Document No: DNU0942000 Rev 1 • Page 2 of 4 (no!link!fitted) Volume (RLY1) CONN3 C 1 -Ve +Ve NC -Ve SIG +Ve NO NC C NO When no calls are on the system, the normally closed contact is made. When an alarm signal is present, the relay switches and the normally open contact is made. Muting the system will have no effect on the relay’s operation. Approved Document No: DNU0942000 Rev 1 • Page 3 of 4