Compliance Sheet of New Doctors Accommodation Building in Tikrit Educational Hospital The following Technical data shall be furnished and filled by the bidders: 1- Diesel Generator 500KVA UNDP specifications Three phase four wires, output voltages 100-400V, 50HZ, between 0.8 lagging, protection capability abiding by the standards of NEMA1 and IP23. General features: ● Composed of western diesel engine and European Type alternator ● Oil and fuel filter fitted, water separator ● Lube-oil drain valve fitted ● Electric starter motor 24 V. D.C ● Output range: Prime-500kVA / Standby-550KVA ● Engine model: 2506(A or C)-E15TAG2 ● Induction system: Turbocharged ● 8-hour operation base tank ● Key start / auto start ● Mechanical /Electrical governor ● 4 pole MCCB, set mounted starting battery ● Soundproof or weatherproof canopy ● Operation & Maintenance manual ● Special Integrated Steel Base tank and sprayed overall in gloss enamel paint Engine Specifications In-line direct injection 6-cylinder diesel engine. Type Water cooled, four cycle, Turbocharged Construction Two valves per cylinder, forged steel crankshaft and connecting rods, cast iron block. Starting 24 volt negative earth. battery charging alternator 35 amp on engine. Cranking current 640 amps at 0oc. Fuel System 24 volt fail safe actuator. Spin-on paper element fuel filters with Bosch fuel pump injection system with integral Bidders’ Offered specifications Electronic governor. Dual flexible fuel lines And connectors. Standard fuel water separator. Filters. Air cleaner with dry element and restriction indicator. Spin full flow lube oil filter. Oil cooler. Drain Tap Control Panels Standard Control Function ● Under / Over Mains Volts /Frequency ● External Remote control start output (load / un-load) ● Configurable relay outputs ● Synchronization auto / synchronization output ● All function telecom remote control ● Engine and Alternator instrumentation monitor ● Configurable input trip point by 9 users ● 4 user output trip point ● Control LCD brightness in low brightness environment ● PIN password ● Send SMS via GSM modem ● Reflect load relay output •Control vary trip point ● AC ALTERNATOR Alternator Technical Data European Type AC alternator ● Brushless, self exciting ● Class ‘H’ insulation ● Standard degree of protection is IP23 ● Self regulating ● With fan cooling ● Resist humid grease ● AC excitation, rotating rectification tube ● Stator grease insulation covered ● Rotator and excitation high polymer, Resist the corruption of oil and acid. ● Rotator balance is in accordance with BS5625 standard 12.5 ● High-quality lubrication sealed long-time bearing ● Rotator silicon steel close tight 2- Electrical Distribution Transformer 400 KVA # UNDP specifications 1- Transformer: Make: ABB, Schneider, Siemens ,LS or equivalent …… wound, 3-phase Rated Power:400KVA, Voltage :11000 V /416 V Current : 52.49 A / 1387.86 A Vector Group : Dyn11 Cooling type : ONAN Frequency:50Hz ●Temperature rise ………( i ) 45 K in top oil by thermometer ( ii ) 50 K in winding by resistance ●The efficiency (at unity power factor and 100% of rated power) of the transformer should be not less than 98.8% ● The duration of the short circuit to raise the temp. of windings from 1050 C to 2500 C should be not less than (5 Sec.) according to IEC 60076-part 5 –clause (4.1.5) ● The thickness of the radiator plates should be shock resistant and don’t affect heat dissipation according to tender requirements. ● The noise level should be ≤ 55 dB at 0.3 meter distance according to IEC standards. ● The low voltage winding must be of copper foil ● Off-load tap changer . . . . . five tapping for (± 2.5%, ± 5%) on the H.T winding for off-circuit operation Bidders’ Offered specifications externally. The mechanical operation must be of the robust and definite position type with a click indicating position arrived during tap changing with suitable pad-lock. ● System Highest Voltage. . H.V side 12 kV ● The 11 kV side terminal is to be flat bar only ● For 400 kVA transformers should be either box-type or plug-in type for H.V. side (according to the tender requirements) with glands and cable holes suitable for cable size of 1 x 50 mm2 , 12/20 kV. ● For L.V. side with glands and cable holes suitable for cable size of 1 x 240 mm2 ● The cables arrangement as specified below: For 400 KVA transformer 11x1x240 mm2 copper (4 holes per phase). 3- Window Air-Conditioner 24,000 BTU Heat/Cool UNDP specifications Performance EER Dehumid. (Pts/Hr) Dry Air Flow (CFM) dBA Level (Indoor / Outdoor) Est. Cooling Area (Sq. Ft.) BTU Performance 9.4 7.8 540 65/68 1001-1500 23,500 / 24,000 FEATURES Heating & Cooling Air Deflection Auto Swing Programmable Timer Fan Only Speed Indoor Fan Type Outdoor Vent / Exhaust Thermostat Control Remote Control Energy Saver Function Fan Speed: Cooling (Heating) Yes 4-Way Yes 12Hr, On/Off 3 Blower Yes Electronic Yes Yes 3 (3) Compressor Rotary Type Air Discharge Side by side Chassis Type ELECTRICAL RATINGS Voltage / 60 Hz Watts (Cooling) Rated Amps (Cooling) Slide In-Out 208/230 2,500/2,550 12.1/11.1 Bidders’ Offered specifications