* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download IPN = 500 .. 1000 A AC/DC Current Transducer DHR-C10
Immunity-aware programming wikipedia , lookup
Audio power wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrical ballast wikipedia , lookup
Mechanical filter wikipedia , lookup
Power inverter wikipedia , lookup
Electrical substation wikipedia , lookup
Power engineering wikipedia , lookup
Current source wikipedia , lookup
Phone connector (audio) wikipedia , lookup
Power MOSFET wikipedia , lookup
Electrical connector wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Ground (electricity) wikipedia , lookup
Three-phase electric power wikipedia , lookup
Earthing system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Voltage regulator wikipedia , lookup
Surge protector wikipedia , lookup
Distribution management system wikipedia , lookup
Power electronics wikipedia , lookup
Buck converter wikipedia , lookup
Current mirror wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
AC/DC Current Transducer DHR-C10 The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 0-10V voltage output. IPN = 500 .. 1000 A Electrical data Primary Nominal C & AC Current D IPN (A.t.RMS) 500 2) 600 2) 1000 2) RL VC IC VSL ÎP Primary AC Current Max. Peak Value 1) IP (A) 1800 1800 1800 Output voltage (Analog) VOUT (VDC) 0-10 0-10 0-10 Load resistance Supply voltage2) Current consumption Output voltage limitation (0 - 10 V) Overload capability (Ampere Turns) Type Features DHR 500 C10 DHR 600 C10 DHR 1000 C10 ≥ 10 + 20 .. 50 30 < 14 30000 kW V DC mA V A.t Performance data X Accuracy @ IPN, TA = 25°C (excluding offset) Linearity error (1% of IPN .. ± IPN) L VOE Electrical offset voltage, TA = 25°C TCVOE Temperature coefficient of VOE ( 0..+60 °C) (-40..+70 °C) TCVOUTTemperature coefficient of VOUT (% of reading) tr Response time to 90 % of IPN step BW Frequency bandwidth (± 1 dB) e < ± 1 % of IPN < ± 1.0 % of IPN < ± 1.0 % of IPN ± 2.0 mV/K ± 4.0 mV/K ± 0.1 %/K < 150 ms DC 20..6000 Hz General data TA TS m IPxx Surrounding operating temperature Surrounding storage temperature Mass Protection degree - 40 .. + 70 - 40 .. + 85 260 IP20 °C °C g Notes :1) The Max. Peak AC Current is the highest peak level of the primary signal that is taken into account for accurate True RMS calculation. Yet the device is designed for maximum continuous True RMS value equal to IPN, whereas the output is limited by the above specified output limitation. 2) According to the UL 508 Standard for Safety for Industrial Control Equipment the primary current must not exceed 475 A.t.RMS through the transducer hole and the supply voltage must not exceed 42VDC.. ●● VFD and SCR waveforms current measurement ●● True RMS output ●● Panel mounting ●● Eliminates insertion loss ●● Isolated plastic case recognized according to UL94-V0 Advantages ●● Large aperture for cable up to Ø32mm ●● High isolation between primary and secondary circuits ●● Easy installation Applications ●● VFD Controlled Loads VFD output indicates how the motor and attached load are operating. ●● SCR Controlled Loads Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement. ●● Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power. Application domain ●● Energy and Automation Page 1/4 120426/00 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Current Transducer DHR-C10 Isolation characteristics Vb Vd Vw dCp dCl CTI Rated isolation voltage rms 3) 300 V according to the standard IEC 61010-1 and with the following conditions: - Reinforced isolation - Over voltage category CAT III - Pollution degree PD2 - Heterogeneous field Rms voltage for AC isolation test 4), 50 Hz, 1min 4.0 kV Impulse withstand voltage 4), 1.2/50 uS 7.3 kV Creepage distance 7.2 mm Clearance distance 7.2 mm Comparative tracking index (Group I) > 600 Notes :3) Between primary conductor voltage and ground. The voltage category could be improved according to the insulation characteristic given by the cable manufacturer. The UL 508 Standard for Safety for Industrial Control Equipment requires that only insulated conductors are used as primary circuit with this transducer. 4) Between primary (completely filling the aperture) and secondary. Transfer characteristics Output in V 10 -Ipn 0 +Ipn Page 2/4 120426/00 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Current Transducer DHR-C10 Safety and warning notes In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. Caution! Risk of danger Ignoring the warnings can lead to serious injury and/or cause damage! The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturers’ operating instructions. Caution! Risk of electrical shock When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a built-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 3/4 120426/00 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions DHR-C5 (in mm. 1 mm = 0.0394 inch) Dimensions DHR-C10 (in mm. 1 mm = 0.0394 inch) 25 Dimensions DHR-C5 (in mm. 170mm = 0.0394 inch) 60 25 70 60 4. 60 25 4 40.60 40 70 40 10 10 6.80 8.30 32 6.80 4 20.34 22.28 4 2.50 2.50 10 90 2.50 25.60 25.60 8.30 8.30 4.60 8.30 7 78 6 6 78 Plug in connector: FKC2.5/4-ST-5.08 (Phoenix Contact) Plug in connector: Plug in connector: FKC2.5/4-ST-5.08 FKC 2.5/4-ST-5.08-RF (Phoenix Contact) (Phoenix Contact) 78 Connections Connections DHR ●● Wires Ø 2 mm • Wires up toup ∅ to 2 mm Connections DHR ●● Female connector provided (spring terminal blocks) • Female connector provided (spring terminal blocks) • Wires up to ∅ 2 mm ●● User-friendly spring-cage connection for no-tool direct • User-friendly spring-cage connection for no-tool direct conductor • Female connector provided (spring terminal blocks) conductor connection connection • User-friendly spring-cage connection for no-tool direct conductor connection Mechanical characteristics Output Connector 1(Vcc) 2(NC) 3(Vout) 4(GND) 24 VDC Power 4 15 7 4.60 33.80 33.80 4.60 33.80 90 6 15 15 25.60 90 8.30 15 22.28 6.80 6.80 8.30 25 15 6.80 22.28 25 25 15 6.80 70 70 32 32 4. 60 70 60 Output Connector 1(Vcc) 2(NC) 3(Vout) 4(GND) Mechanical characteristics 24 VDC Power ●● General tolerance ±1 mm Ø 32.0 mm ±1 mm ● ● Panel mounting • Primary aperture ∅ 32.0 mm Ø 4.6 mm • General tolerance ±1 mm 4 holes ● ● Distance between holes 70.0 78 mm • Panel mounting 4 holes 4.6&mm • Primary aperture ∅ 32.0 mm ∅mm (see between above dimensions) • Distance holes 70.0 & 78 mm • Panel mounting 4 holes ∅ mm 4.6 mm panel holes mounting, use70.0 M4 screws (not supplied) with (see&above dimensions) • DistanceFor between mm 78 mm appropriate length to panel´s thickness, and tighten to (see abovebydimensions) For panel mounting, replace M4 screws new one (not supplied) Forwith panel mounting, replace M4panel´s screws thickness. by new one (not supplied) 0.75Nm +/-20% appropriate lengthtorque. to (+) Mechanical characteristics ●● Primary aperture • General tolerance (+) (-) (-) (-) (-) 10k 10k (+) Load (+) Loadmeter etc) (Controller, with appropriate length to panel´s thickness. (Controller, meter etc) Remarks Remarks ●● The temperature of the primary busbar can not exceed Remarks +24VDC +24VDC Is Is Ip OUT OUT Ip GND GND 120426/00 080725/15 080725/15 90 °C. • The temperature of the primary busbar can not exceed 90 °C. • The temperature ofperformances the primary canbest not with exceed 90 busbar °C. ●● Dynamic arebest the a primary • Dynamic performances arebusbar the with a primary • Dynamic performances are the best with a primary busbar busbarfilling completely filling aperture. the primary aperture. completely the primary completely filling the primary aperture. ●● is This is a standard model. For different versions • This a standard model. For different versions (supply voltages, • This is a standard model. For different versions (supply voltages, (supply voltages, different measurements...), outputs, bidirectional different outputs, bidirectional please different outputs, bidirectional measurements...), please measurements...), please contact us. contact us. contact us. Page 4/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 4/4 Page 4/4 www.lem.com www.lem.com www.lem.com