Download FDOOT801-A1 Multisensor fire detector for Railway

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
FDOOT801-A1
Multisensor fire detector for Railway
l
l
l
l
l
l
Railway S-SIL 2 certified
High availability level
Auto addressable or stand alone configuration
High immunity to deceptive phenomena
Early and reliable detection of emerging fires
Ecological material concept
Building Technologies
CPS Fire Safety
Characteristics
l
Characteristics
resistant to environment, interference factors as per EN50155
insulated as per EN50154
insensitive to impact, shocks as per EN61373
tamper protection
signal processing with MCR algorithm
protected electronics, high-quality components
sophisticated sensor and electronics surveillance
redundant, high-quality sensor system
l
Environmental benefits
ecologically processing as per ROHS directive
recyclable materials
ecologically beneficial detector testing without gas
–
–
–
–
–
–
–
–
–
–
–
Multi-function fire detectors
l
–
–
–
–
–
–
–
–
Function
multi-setup: Network with fire control panel FSVCU or stand alone
works according to the scattered light principle with two sensors, optical forward and
backward scattering
opto-electronic sampling chamber holds off disturbing extraneous light but optimally
detects both dark and light smoke particles
four additional heat sensors increase the fire detector’s immunity to deceptive phenomena and allow a working mode in heat detector
software can be set to multi-sensor smoke detector as per EN54-7 or heat detector
as per EN54-5
two detection peripherals as LHD, MCP .. can be managed when connected on discrete inputs
easy ‘plug & play’ installation/replacement when connected with FSVCU
management of auxiliary fire protection peripherals with one multipurpose input and
one output
l
–
–
–
–
–
Application
designed for railway applications
for a high availability level
for high safety purpose especially where SIL 2 is requested
for the early and reliable fire detection in environments with deceptive phenomena
for the early detection of flaming fires caused by the combustion of liquid and solid
matters, as well as smoldering fires
2
Building Technologies
CPS Fire Safety
Installation
l
l
Connectors :
l
IO/Power connector: UT001619PH
l
Can bus connectors for communication loop: 2 Sub D9 (male & female)
Mounting: with x 4 M6 screws on the base plate. Integration could also be done through the
ceiling with a round hole of 100mm and 4mm of thickness.
3
Building Technologies
CPS Fire Safety
Efficiency on board
–
–
–
Line replaceable unit: only detector exchange
Auto diagnostic for pollution check
Build in test design
Dimensions
4
Building Technologies
CPS Fire Safety
Technical data
Supply voltage
DC 24 V
Operating voltage
Operating current (quiescent)
DC 16... 30 V
< 45 mA
Alarm and Fault indicator
1 + 1 dry contacts
Fire protection output
Monitored detection input (LHD, MCP..)
Monitored Multi purpose input
1 dry contact
2
1
Communication protocol
System compatibility
Can 2.0 B
FSVCU
Operating temperature
Storage temperature
-40... +85 °C
-55... +85 °C
≤95 % rel.
white, ~RAL 9010
Humidity
Color
Protection cat. EN60529/IEC529
IP41
Fire Detection Standards
EN54-5, EN54-7
General Railways standard
EN50155, EN50124
Railway development standards
Railway Fire protection standards
EN50126, 50128, 50129
EN45545-2
Approvals
– Certifier
S SIL 2 (pending)
QS standards
Siemens Standard SN 36350
Weight
360 g +-20g
Details for ordering
5
Building Technologies
CPS Fire Safety
Type
Part no
Designation
FDOOT801-A1
S54339-F100-A1
Multisensor fire detector
Siemens Switzerland Ltd
Infrastructure & Cities sector
Building Technologies Division
International Headquarters
CPS Fire Safety
Gubelstrasse 22
CH-6301 Zug
Tel. +41 41 724 24 24
www.siemens.com/buildingtechnologies
Document no.
A6V10400978_b_en_--
Edition
03.2014
© 2014 Copyright by
Siemens Switzerland Ltd
Data and design subject to change without notice.