FDOOT801-A1 Multisensor fire detector for Railway l l l l l l Railway S-SIL 2 certified High availability level Auto addressable or stand alone configuration High immunity to deceptive phenomena Early and reliable detection of emerging fires Ecological material concept Building Technologies CPS Fire Safety Characteristics l Characteristics resistant to environment, interference factors as per EN50155 insulated as per EN50154 insensitive to impact, shocks as per EN61373 tamper protection signal processing with MCR algorithm protected electronics, high-quality components sophisticated sensor and electronics surveillance redundant, high-quality sensor system l Environmental benefits ecologically processing as per ROHS directive recyclable materials ecologically beneficial detector testing without gas – – – – – – – – – – – Multi-function fire detectors l – – – – – – – – Function multi-setup: Network with fire control panel FSVCU or stand alone works according to the scattered light principle with two sensors, optical forward and backward scattering opto-electronic sampling chamber holds off disturbing extraneous light but optimally detects both dark and light smoke particles four additional heat sensors increase the fire detector’s immunity to deceptive phenomena and allow a working mode in heat detector software can be set to multi-sensor smoke detector as per EN54-7 or heat detector as per EN54-5 two detection peripherals as LHD, MCP .. can be managed when connected on discrete inputs easy ‘plug & play’ installation/replacement when connected with FSVCU management of auxiliary fire protection peripherals with one multipurpose input and one output l – – – – – Application designed for railway applications for a high availability level for high safety purpose especially where SIL 2 is requested for the early and reliable fire detection in environments with deceptive phenomena for the early detection of flaming fires caused by the combustion of liquid and solid matters, as well as smoldering fires 2 Building Technologies CPS Fire Safety Installation l l Connectors : l IO/Power connector: UT001619PH l Can bus connectors for communication loop: 2 Sub D9 (male & female) Mounting: with x 4 M6 screws on the base plate. Integration could also be done through the ceiling with a round hole of 100mm and 4mm of thickness. 3 Building Technologies CPS Fire Safety Efficiency on board – – – Line replaceable unit: only detector exchange Auto diagnostic for pollution check Build in test design Dimensions 4 Building Technologies CPS Fire Safety Technical data Supply voltage DC 24 V Operating voltage Operating current (quiescent) DC 16... 30 V < 45 mA Alarm and Fault indicator 1 + 1 dry contacts Fire protection output Monitored detection input (LHD, MCP..) Monitored Multi purpose input 1 dry contact 2 1 Communication protocol System compatibility Can 2.0 B FSVCU Operating temperature Storage temperature -40... +85 °C -55... +85 °C ≤95 % rel. white, ~RAL 9010 Humidity Color Protection cat. EN60529/IEC529 IP41 Fire Detection Standards EN54-5, EN54-7 General Railways standard EN50155, EN50124 Railway development standards Railway Fire protection standards EN50126, 50128, 50129 EN45545-2 Approvals – Certifier S SIL 2 (pending) QS standards Siemens Standard SN 36350 Weight 360 g +-20g Details for ordering 5 Building Technologies CPS Fire Safety Type Part no Designation FDOOT801-A1 S54339-F100-A1 Multisensor fire detector Siemens Switzerland Ltd Infrastructure & Cities sector Building Technologies Division International Headquarters CPS Fire Safety Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Document no. A6V10400978_b_en_-- Edition 03.2014 © 2014 Copyright by Siemens Switzerland Ltd Data and design subject to change without notice. Supply subject to availability.