Download OPTION 140-50 Current Coil

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

History of electromagnetic theory wikipedia , lookup

Stepper motor wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Loudspeaker wikipedia , lookup

Commutator (electric) wikipedia , lookup

Wireless power transfer wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Ohm's law wikipedia , lookup

Opto-isolator wikipedia , lookup

Buck converter wikipedia , lookup

Skin effect wikipedia , lookup

Current source wikipedia , lookup

Electric machine wikipedia , lookup

Transformer types wikipedia , lookup

Loading coil wikipedia , lookup

TRIAC wikipedia , lookup

Tesla coil wikipedia , lookup

Capacitor discharge ignition wikipedia , lookup

Alternating current wikipedia , lookup

Inductor wikipedia , lookup

Multimeter wikipedia , lookup

Magnetic core wikipedia , lookup

Rectiverter wikipedia , lookup

Ignition system wikipedia , lookup

Coilgun wikipedia , lookup

Resonant inductive coupling wikipedia , lookup

Transcript
OPTION 140-50 Current Coil
•
•
•
•
•
•
•
For clamp ampermeters calibration up
to 1000 A
•
Multiplying coefficient x50, x25
•
Option for series M-140 / M-142 /
M-141 / M-103 Calibrators
MEATEST, spol. s r.o., Kš írova 118a, 619 00 Brno, CZ
Tel. +420 543250886(7)
www.meatest.cz
Fax: +420 543250890
[email protected]
Technical data
Maximum input current
20 A / 5 min
Number of windings
x 25, x 50
Accuracy:
± 0.3 % for DC current
± 0.3 % for AC current to 100 Hz
Temperature range
5 oC - 40 oC
Weight
approx. 1,2 kg
Cross section area of the post
25 x 13 mm ( 25 turns )
24 x 26 mm ( 50 turns )
Dimensions:
Note:
195 x 125 x 40 mm
Range of applicable current versus frequency ratio can be limited by loading features of
tested clamp ammeter, due to exceeding max. compliance voltage of the calibrator in curren t
mode. Load impedance of current coil is created of combination of current coil impedance and
magnetic coupling of ammeter tongs.
OPTION 140-50 is 50 and 25 turn current coil. It is created by copper wire coil of circular
form, which is encapsulated in epoxy foam. Current coil is equipped with three standard
instrument terminals.
In connection with multifunction calibrator series M-140 / M-140i / M 141 / M-142 / M-142i /
M-103 AC and DC clamp ammeters can be calibrated in range to 1000 A. The coil has to be
connected to the current output terminals +I and –I in calibrator through cables. To avoid
additional errors during calibration of clamp ammeters recommended mutual position of
current coil to device under test is shown on following figure. Calibration of clamp ammeters
should be performed on place where no magnetic conductive parts are presented otherwise
error due to distortion of magnetic field around coil can influence uncertainty of calibration.
Option 140-50
Option 140-50
x25
METER
x50
METER