Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 UNDERSTANDING ELECTRICAL SCHEMATICS Part 2 by Howard L. Pemper, CMS INTRODUCTION for example, shows both a normally open and a normally closed single-pole, single-throw (SPST) switch. This type of switch either opens or closes one circuit. Figure 1B shows a single-pole, double-throw (SPDT) switch. Again, only one circuit can be controlled at any given time, but in this case the switch has two different “connected” positions, which means that it can direct current to either of two paths. In this section, you will take a look at a packaged gas/electric system, which is a relatively complex heating and cooling unit. The wiring diagram for this equipment is more difficult than those you studied in Part 1—but again, the schematic as a whole can be simplified by breaking it down into its basic circuits. As you examine individual control circuits and the associated components that they operate, the overall diagram becomes easier to understand, as do the various machine functions. The schematics in this section may include some symbols with which you are not familiar. For your convenience, many of the schematic symbols currently used and recognized by the HVAC/R industry are collected in Figure 16 at the end of this chapter. A. Single-pole, single-throw (SPST) Normally closed (N/C) Normally open (N/O) SWITCH SYMBOLS B. Single-pole, double-throw (SPDT) Generally speaking, a wiring schematic shows the condition of a piece of equipment when there is no power being applied to the unit. Therefore, if a switch is depicted as being normally open (N/O) or normally closed (N/C), remember that the position of the switch is shown as it appears when there is no power applied to that circuit. If there is any deviation from this practice, there will be an explanatory note on the schematic. C. Double-pole, double-throw (DPDT) As you may know, a switch is characterized by the number of contacts (or poles) and the number of positions (or throws) it has. Think of the number of poles as the number of circuits that the switch can control at one time, and the number of throws as the number of paths a single circuit can take. Figure 1A, © 2003 by the Refrigeration Service Engineers Society, Des Plaines, IL Supplement to the Refrigeration Service Engineers Society. Figure 1. Switch symbols 1 630-141 Section 4A n Double-pole, single-throw (DPST) operation of the control. In Figure 3, for example, the temperature switch (RS-2) is shown with the arm above the contacts. This signifies that the switch opens on a rise in temperature and closes on a drop in temperature. The pressure switch (AFS-2) is shown with the arm below the contacts. This signifies that the switch opens on a drop in pressure and closes on a rise in pressure. Double-pole, double-throw (DPDT) An example of an SPDT limit switch (LS) is shown in Figure 4. When there is an increase in temperature, the contacts “C” to “N/C” move to the “N/O” position. When the temperature decreases, the contacts “C” to “N/O” move back to the “N/C” position. Relays Relays are electrically operated control switches. The schematic symbols used to represent relays are the same as those for manually operated switches, except that relay symbols often include a solenoid coil. There are several possible ways of depicting the solenoid coil. Figure 5 shows two different schematic representations of a DPDT relay. Note that multiplepole relays, like multiple-pole switches, are connected mechanically but not electrically. Three-pole, single-throw (3PST) Contactors Figure 2. Multiple-pole switches A contactor is a type of heavy-duty relay that handles higher voltages and higher currents than a control A switch that can control more than one circuit at a time is shown schematically as having more than one set of contacts. Look back at Figure 1C on the previous page. It shows an example of a double-pole, double-throw (DPDT) switch, which can control two circuits at the same time. The dashed line represents the mechanical connection, and tells you that the contacts move together, but are not connected electrically. Figure 2 above shows a few of the many other variations that are possible in depicting multiple-pole switches. RS-2 1 AFS-2 3 1 2 Figure 3. Temperature and pressure controls N/O Controls LS C Pressure and temperature controls are switches, too, and they also may be configured with various combinations of poles and throws. The position of the switch “arm” in the schematic symbol indicates the N/C Figure 4. SPDT limit switch 2 Coil Coil Figure 5. DPDT relays relay. Contactors appear nearly identical to relays on schematic diagrams. Some manufacturers employ contactors that use a single set of contacts. A “bus bar” is placed over the connection where the other set would be, as shown in Figure 6. Figure 16 at the end of this chapter includes many other symbols for switches and relays. L1 L2 T1 T2 Coil Figure 6. Two-pole contactor with bus bar THE BASIC DIAGRAM problems that you may encounter with a particular type of equipment. Let’s take a look at a “generic” schematic of a packaged heating/cooling unit. In order to illustrate the various options that may be possible with a unit of this kind, the schematic has been put together by taking parts from several different manufacturers. Because of its complexity, the schematic is broken into three parts. Figure 7 (spread across pages 4 and 5) shows the high-voltage components, and Figure 8 (pages 6 and 7) shows the low-voltage or control circuits. There normally is no “point-to-point” or line diagram with this type of schematic, but a component layout is often provided. This is shown in Figure 9 (pages 8 and 9). RELAYS As you saw earlier, relays can and do have many contacts. A single relay may have a function in two, three, or sometimes four different circuits. Its contacts may be located in various parts of the schematic, and you must know how to find them if you are to know how the unit works. In our generic diagram, several relays provide lockouts for the cooling and heating sections, which means that the two sections cannot come on at the same time. EQUIPMENT Locate control relay CR-1 at the bottom of Figure 8 (line 183). Now look at the detail shown in Figure 10A (found on page 10). As you can see, control relay CR-1 has five sets of contacts that are operated by one coil. The first two sets of contacts, CR-1a and CR-1b, are found on lines 42 and 48, respectively (see Figure 10B). The third set, CR-1c, is found on line 77 (see Figure 10C). The fourth set, CR-1d, is found on line 149 in the low-voltage section of the schematic (see Figure 10E). The last set, CR-1e, is found on line 90 (see Figure 10D). Remember that when a number in the right-hand margin of Figure 10A is underlined, it designates a set of normally closed (N/C) contacts. In order to service any piece of equipment, you first must know what you are working with. Even before you begin a visual inspection of the equipment itself, a quick look at the schematic will give you a general idea of the type of equipment and its components. In Figure 7, for example, it’s easy to spot the two compressors—therefore, you can assume that this is a two-stage cooling system. Likewise, in Figure 8 you can see two ignition systems—again, you can conclude that this is a two-stage heating system. With just a quick glance at the schematic, you have determined what the unit is. As you become more experienced, you also may have a good idea of the kinds of 3 Figure 7. High-voltage circuits 4 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 YEL 115 V 208 V CB-1 110 A BLU TRSF-1 230 V YEL BLK BLU YEL BLK YEL CR-1a 1 3 FU-1 8A GRY BLK BLK BLK GND 208/230-3Ø TB-1 BLU YEL BLK YEL BLU YEL BLK BLU YEL BLK IFMC CC-1 T3 T2 T1 T3 T2 T1 T2 L2 T2 OFMC-2 L1 T1 L2 OFMC-1 L1 T1 L3 L2 L1 L3 L2 L1 BLU YEL BLK YEL BLU YEL BLK 1 ATS 3 T3 L3 BLU T1 T2 CC-2 L2 L1 YEL BLK BLU YEL BLK R C S R C S C1 OFMC-2 C2 C1 OFMC-1 C2 CAP CAP IFM BLU YEL BLK BRN BRN COMP-1 BRN C2 OFMC-2 C2 OFMC-1 TRSF-1 OFM-2 OFM-1 29, 31 22, 24 COMP-2 Figure 7. High-voltage circuits (continued) 5 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 GRY GRY CR-7 IFRC IFRH 3 3 3 IDFMR 1 3 CR-1e 13 15 1 1 1 CR-2b 1 2 CR-1c 1 2 BLK 3 ASR-2 1 3 CR-2a 1 1 BLU BLU/RED 3 ASR-1 1 6 CR-1b 4 CCPS L 2 GRY GRY M OFC-2 M OFC-1 L HPS-1 2 HPS-2 2 120 V 220 V 120 V 2 ASR-2 3 1 220 V 2 ASR-1 3 1 C 3 C2 C1 IDFM C2 C1 USLV C1 IFMC C2 CC HTR-2 OFC-2 C1 TDR-2 C2 C1 CC-2 C2 OFC-1 4 TDR-1 6 C1 CC-1 C2 CC HTR-1 Heater TDR-2 LPS-2 Heater TDR-1 LPS-1 WHT C 1 BRN BRN BRN BRN BRN BRN BRN BRN BRN BRN OFC-2 TDR-1 C2 IDFM C2 USLV-1 C2 IFM C2 IFMC-2 CC HTR-2 CC HTR-1 OFC-2 C2 TDR-2 C2 CC-2 C2 CC-2 BRN 6 C2 CC-1 C2 CC-1 15, 17, 18 63 63, 68 9, 10, 12 48 48, 53 1, 3, 4 Figure 8. Low-voltage circuits 6 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97 96 95 IGN-2 IGN-1 C CB-2 3A LS 24 V 115 V 1 1 GVR-2 IGN PCB GVR-1 N/C N/O BLU BLK RS-2 RS-1 YEL 3 2 TRSF-2 WHT 1 1 IGN-2 AFS-2 IGN-1 AFS-1 2 3 1 CSb CSa 3 T1 T1 FS IGN-2 GVR-2 FS IGN-1 GVR-1 IGN GV-2 IGN GV-1 T2 T2 C1 CR-7 C2 VIO VIO VIO VIO VIO VIO T2 IGN PCB IGN-2 IGN-1 C2 TRSF-2 T2 GV-1 T2 CR-7 TRSF-2 Figure 8. Low-voltage circuits (continued) 7 188 187 186 185 184 183 182 181 180 179 178 177 176 175 174 173 172 171 170 169 168 167 166 165 164 163 162 161 160 159 158 157 156 155 154 153 152 151 150 149 148 147 146 145 144 6 9 6 3 3 HR-1a 1 HR-2a 1 HR-1b 4 HR-1c 7 HR-2b 4 5 CR-1d 12 CR-2c 10 4 2 LOGIC TDR-3 1 3 R G W2 W1 Y2 Y1 C C1 CR-1 C2 C1 CR-2 C2 C1 HR-1 C2 C1 HR-2 C2 C1 IFRC C2 C1 IFRH C2 C1 IDFMR C2 VIO VIO VIO VIO VIO VIO VIO VIO LOGIC C2 USLV-1 C2 CR-1 C2 CR-2 C2 CR-2 C2 CR-2 C2 HR-2 C2 HR-1 C2 IFRC 3 IDFMR C2 IFRH C2 IDFMR 42, 48, 77, 149, 90 63, 80, 146 161, 152, 149 158, 146 85 82 92 8 7 9 6 3 5 4 6 3 C2 C2 Figure 9. Component layout 8 TRSF-2 C1 C1 4 1 5 2 IFRH 5 2 6 3 6 3 C1 C1 5 2 6 3 4 1 TRSF-1 5 2 6 3 IDFMR 1 CCPS 2 C2 C2 4 1 HR-1 C2 C2 1 1 4 1 5 2 CR-7 5 2 AFS-2 2 AFS-1 2 C1 C1 4 1 HR-2 6 3 6 3 C2 C2 3 1 IGN-1 3 RS-2 1 RS-1 N/O C N/C LS T1 T2 IGN-2 GV-1 T1 GV-2 W2 W1 Y2 Y1 GVR-2 IGN PCB 2 1 IFRC 13 14 15 4 1 CR-2 G GVR-1 C1 C1 5 4 10 11 12 2 1 CR-1 R C T2 Figure 9. Component layout (continued) 9 8 5 7 4 6 9 3 TDR-2 L L 208/230/3-phase 2 1 COMP-1&2 TDR-1 220 V 120 V OFC-2 220 V 120 V OFC-1 C2 T2 T1 C1 L2 L1 OFMC-1 M M C1 T1 L1 1 3 1 3 1 C2 T2 L2 3 TDR-3 ASR-2 ASR-1 OFMC-2 2 4 2 4 2 CAP-2 CAP-1 C1 T1 L1 T2 L2 CC-1 C1 T1 L1 C2 T3 L3 T2 L2 IFMC T2 L2 CC-2 C2 T3 L3 C1 T1 L1 C2 T3 L3 Detail A 178 179 180 C2 CR-1 181 182 C1 CR-1 C2 183 C2 USLV-1 VIO 42, 48, 77, 90, 149 184 185 186 187 Detail B 37 38 39 40 FU-1 8A CR-1a 1 3 41 42 BRN C2 OFMC-1 C1 OFMC-2 C2 BRN C2 OFMC-2 ATS 1 43 44 C1 OFMC-1 C2 3 GRY BRN 45 46 47 48 CR-1b 4 ASR-1 6 1 OFC-1 3 L M 1 2 1 3 C1 CC-1 C2 BRN C2 CC-1 49 50 HPS-1 LPS-1 51 Detail C 75 76 77 CR-1c 1 2 CC HTR-1 GRY BRN CC HTR-1 78 79 87 88 89 Detail D CR-1e 13 15 USLV CCPS 1 2 C1 90 91 Detail E 147 148 149 150 7 9 HR-1c 10 12 CR-1d 151 152 Figure 10. Locating control relay contacts 10 C2 C2 USLV-1 CC-1 CR-1b ASR-1 OFC-1 HPS-1 LPS-1 Figure 11. Series circuit CIRCUITS flow is indicated by the arrows. Notice that the current must pass through all of the switches before it can energize the coil. If any of the switches is open, the coil cannot be energized. A schematic diagram can look complicated when viewed as a whole. However, as stated previously, it becomes much easier to analyze a problem if you break down the large diagram into smaller individual circuits. All electric circuits conform to one of three basic arrangements. Parallel circuits In a parallel circuit, there are two or more separate paths or branches for current flow. A parallel circuit arrangement allows any one of a number of controls or switches to energize a load. Look at Figure 12A, for example. When either of relay contacts IFRH or IFRC is closed, current will pass through the circuit and energize coil IFMC. However, note that both IFRH or IFRC must be open in order for the coil to be de-energized. Series circuits In a series circuit, components are arranged one after another, so that the same current flows through all of the components in one continuous path. Figure 11 shows an example of a number of switches and a relay coil connected in series. The direction of current A. Multiple switches, single load IFMC IFRH IFRC B. Single switch, multiple loads OFMC-1 CR-1a ATS OFMC-2 Figure 12. Parallel circuits 11 CC-1 CR-1b ASR-1 OFC-1 HPS-1 LPS-1 TDR-1 ASR-1 220 V TDR-1 120 V Heater OFC-1 Figure 13. Series-parallel circuit A single switch can energize several loads at the same time in a parallel circuit. All of the loads will get the same amount of current when the switch closes. In Figure 12B, for example, when switch CR-1a is closed, current will pass through the circuit and energize coil OFMC-1. And as long as thermostat ATS is closed, coil OFMC-2 also will be energized. multiple-path) circuits. Such a circuit allows some operations to proceed while stopping others. Seriesparallel circuits are primarily used in control and safety applications. The detail shown in Figure 13 above illustrates a series-parallel circuit. When switch CR-1b closes, current flows through both branches of the circuit. As long as all of the switches ASR-1, OFC-1, HPS-1, and LPS-1 are closed, current passes through the upper branch and energizes coil CC-1. If any of the switches is open, however, the current will be allowed to pass only through the lower branch to coil ASR-1. Series-parallel circuits As the name implies, a series-parallel circuit is a combination of series (or single-path) and parallel (or C1 IDFMR C2 IFRH C2 IDFMR IDFMR 1 2 3 1 2 3 4 5 6 4 5 6 C2 IFRH C1 IFRH C2 C1 IDFMR A. Schematic diagram C2 C1 B. Component diagram Figure 14. Terminal connections 12 C2 With all of the switches in the upper branch closed and coil CC-1 energized, current simultaneously passes through the TDR-1 contacts to the TDR-1 relay. This is a “delay-on-make” time-delay relay, which means that after a specified period of time, the TDR-1 contacts will open. This type of control is commonly used for low-pressure bypass during low ambient conditions. When coil CC-1 is energized, note that current also passes through the 120-V resistor, through the resistor marked “Heater,” and through differential pressure control OFC-1. This is an oil failure control. When oil pressure is sufficient, differential pressure control OFC-1 will open, thus taking the heater out of the circuit and preventing the OFC-1 contacts from opening. IGN-1 GVR-2 IGN-1 IGN PCB IGN-2 CONNECTIONS AND WIRING GVR-1 GVR-2 Figure 15. Relay connections on igniter printed circuit board In order to conserve wire and space, some manufacturers terminate more than one coil connection at the same point. This practice is depicted schematically as shown in Figure 14A, where the terminals from the IDFMR and the IFRH are taken off the same terminal connection. Note that the schematic shows two connections or wires at that point (the arrows point to the connection points). Because line diagrams are not used in complex schematics, the component diagram will show the terminal connections on the relays and other devices (see Figure 14B). contacts for the igniters are on the printed circuit board, but they cannot be physically replaced. The contacts themselves are usually shown enclosed in a “box” drawn with dashed or dotted lines. This same approach is used for the gas valve relay shown in Figure 15, and in some instances for fan relays as well. LEGENDS There normally isn’t enough space on a schematic to accommodate the full spelling of each component. A legend listing many of the abbreviations used in the schematic that you have been studying is shown on the next page. In some cases, a control or relay may not be shown as a replaceable item, or even as a component that can be tested. In Figure 15, for example, the timing 13 LEGEND AFS . . . . . Air flow switch IDFM . . . . . Inducer fan motor ASR . . . . . Anti short-cycle relay IDFMR . . . . . Inducer fan motor relay ATS . . . . . Air temperature switch IFM . . . . . Indoor fan motor CAP . . . . . Capacitor IFMC . . . . . Indoor fan motor contactor CB . . . . . Circuit breaker IFRC . . . . . Indoor fan relay (cooling) CC . . . . . Compressor contactor IFRH . . . . . Indoor fan relay (heating) CC HTR . . . . . Crankcase heater IGN PCB . . . . . Igniter printed circuit board CCPS . . . . . Capacity control pressure IGN . . . . . Igniter switch LPS . . . . . Low-pressure switch COMP . . . . . Compressor LS . . . . . Limit switch CR . . . . . Cooling relay OFC . . . . . Oil failure control CS . . . . . Centrifugal switch OFM . . . . . Outdoor fan motor FS . . . . . Flame sensor OFMC . . . . . Outdoor fan motor contactor FU . . . . . Fuse RS . . . . . Rollout switch GND . . . . . Ground TB . . . . . Terminal board GV . . . . . Gas valve TDR . . . . . Time-delay relay GVR . . . . . Gas valve relay TRSF . . . . . Transformer HPS . . . . . High-pressure switch ULSV . . . . . Unloader solenoid valve HR . . . . . Heating relay Note: Figure 16 on the following three pages shows many of the schematic symbols used in the HVAC/R industry today. 14 SWITCHES N/O or N/C or Closes on fall Closes on rise Pushbutton switches N/O Pressure SPST N/C Two-position Temperature H-O-A switch HAND SPDT OFF Liquid level AUTO Foot switches Flow DPST N/O N/C Limit Time-activated switches DPDT Differential pressure De-energized Energized RELAYS Coil SPST (N/O) Coil DPST Coil Coil Coil SPST (N/O) SPST (N/C) Coil Coil SPST (N/C) Coil SPDT DPST SPDT Coil Coil DPDT DPDT L1 L1 L2 Coil T1 2-pole contactor T2 L1 L2 Coil L2 L3 Coil T1 T2 T1 2-pole contactor with bus bar T2 3-pole contactor Figure 16. Schematic symbols 15 L1 L2 L3 T1 T2 T3 Coil T3 3-pole contactor with bus bar TRANSFORMERS Primary 115 V Current transformer Boost-and-buck transformer Secondary 24 V “Boosting” 24 V 460 V 230 V 208 V 120 V “Bucking” 2.5 V Common Multivoltage control transformers Common Tapped 460-V primary 460-V primary H1 H2 H3 H4 H1 H2 H3 H4 X1 X2 X3 X4 X1 X2 X3 X4 Variable 230-V secondary 120-V secondary 230-V primary Air core 115 V 10 kV 230-V primary H1 H2 H3 H4 H1 H2 H3 H4 X1 X2 X3 X4 X1 X2 X3 X4 460-V secondary Always consult the manufacturer’s nameplate for proper connections. High-voltage transformer Circuit breakers Fuses Cartridge or plug fuse 120-V secondary Thermal overload switch Fusible link Singlepole Doublepole Overload safety switch Triplepole Mechanical interlock Thermal overload Figure 16. Schematic symbols (continued) 16 Magnetic overload switch Ground connections Conductors Chassis ground Wires connected Wires crossing but not connected Thermocouple Earth ground Lamp Capacitor (fixed) Battery Terminal nearest ground Shielded cable ELECTRONIC COMPONENTS Transistors Multiple-conductor cable Diode C AND gate Number of conductors in conduit or cable B SCR Connectors E NPN NAND gate Male C B Female LED OR gate E PNP Engaged (plug and receptacle) Diac NOR gate D G Resistors S N-channel JFET Fixed Triac NOT gate D G Potentiometer Zener diode Variable S Buffer amp P-channel JFET Rheostat Tunnel diode Op amp Tapped UJT Photodiode Resistance heater Solenoid Thermistor MOV T Cad cell Figure 16. Schematic symbols (continued) 17 IGT Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, IL 60016 847-297-6464