* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download AnyMedia Access System Release 1.6.2 PFU502 POWER FILTER
Power factor wikipedia , lookup
Standby power wikipedia , lookup
Buck converter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Wireless power transfer wikipedia , lookup
Voltage optimisation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Life-cycle greenhouse-gas emissions of energy sources wikipedia , lookup
Audio power wikipedia , lookup
Electric power system wikipedia , lookup
Electrification wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Alternating current wikipedia , lookup
Surge protector wikipedia , lookup
Power over Ethernet wikipedia , lookup
Power engineering wikipedia , lookup
Mains electricity wikipedia , lookup
Power supply wikipedia , lookup
Lucent Technologies Data Sheet 363-211-523, Issue 1 AnyMedia® Access System Release 1.6.2 PFU502 POWER FILTER UNIT (PFU) 1 Overview The Power Filter Unit (PFU) is designed as a plug-in and connects the DC powered AnyMedia Access System with the external power supply through one power supply bus (-48AE or -48BE) or two power supply busses (-48AE and -48BE). The PFU502 offers filtering and overvoltage protection to the outputs. 2 Features and Functions The main features/functions of the PFU502 are as follows: Noise filtering of both DC power inputs in both directions Protection of AnyMedia Access Systems against transient overvoltages Supply of redundant powering Voltage gap buffering up to 5 ms at nominal voltage Surge protection up to 1 kV Limiting inrush current in accordance with ETS 300 132-2. (05.02) 1 AnyMedia Access System Release 1.6.2 3 Description This data sheet describes the PFU502 plug-in (Comcode 109205716). The PFU502 is build up as an insertion circuit pack and connects the DC powered AnyMedia Access System with the external power supply through one power supply bus (-48AE or -48BE) or through two power supply busses (-48AE and -48BE). Each power supply bus is able to deliver the entire input power of approximately 453 W to the system. Half of the -48V DC input power is delivered by the -48A line and the common -48RTN line, the other half of the input power is delivered by the -48B line and the common -48RTN line. The PFU502 provides gradual charging of the capacitors. The inrush current surge is limited according ETS 300 132-2. Figure 1 shows the block diagram of the PFU502, the faceplate is shown in Figure 2. -48AE Surge Protection Filter Unit -48A O-ring diode -48BE Surge Protection -48RTN -48RTN FRMGND Figure 1 2 (05.02) -48B EMC Reduction and ESD Protection PFU502 Block Diagram 363-211-523 AnyMedia Access System Release 1.6.2 DANGER: ARCING Arcing on removing or inserting the Power Filter Unit. Arcing can cause burns to the hands and damage to the eyes. Ensure that the DC circuit-breakers on the fuse panel are in the “OFF” position before removing or inserting the Power Filter Unit. DANGER: HOT SURFACE After removing the Power Filter Unit the attached heatsink on the bottom of the printed circuit board can be very hot. It can cause burns to the hands. Ensure that the heatsink is not hot before touching it. 4 Installation and Testing There are no switches to set on this plug-in. 363-211-523 (05.02) 3 AnyMedia Access System Release 1.6.2 5 Faceplate Features and Options There are no LEDs and no buttons on the PFU502 faceplate. The faceplate of the PFU502 is shown in Figure 2. PFU5012 S n:m Lucent TURN POWER OFF BEFORE REMOVING THIS UNIT WARNING: HOT SURFACE BEHIND FACEPLATE Figure 2 6 PFU502 Faceplate Power Consumption Table 1 Power Consumption Typical value at 453W Nominal supply voltage PIN a Typical value in idle state -48 V DC approx. 0.06 W approx. 9.24 W a PIN means input power 4 (05.02) 363-211-523 AnyMedia Access System Release 1.6.2 7 Ordering Information Additional copies of this document (363-211-523) are available from the Customer Information Center: 8 Domestic Lucent Technologies manufacturing sites: call 1-888-LUCENT-8 (which translates to 1-888-582-3688) International Lucent Technologies manufacturing sites from the North America Region: fax orders to 1-317-322-6359, or e-mail requests to [email protected] Sites in Asia/Pacific, China, or CALA: fax orders to 1-317-322-6699, or e-mail requests to [email protected] Sites in EMEA: fax orders to 1-317-322-6699, or e-mail requests to [email protected]. Comments Comments about this document can be directed to: Lucent Technologies Network Systems GmbH Facsimile +49 9 11 526-35 45 9 Copyright Information Copyright © 2002 Lucent Technologies. All rights reserved. This material is protected by the copyright and trade secret laws of the United States and other countries. It may not be reproduced, distributed or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts or licensing, without the express written consent of the Customer Training and Information Products organization and the business management owner of the material. 363-211-523 (05.02) 5 AnyMedia Access System Release 1.6.2 6 (05.02) 363-211-523