Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
THREE DIMENSIONAL RECONSTRUCTION OF EXOSKELETON BY CONFOCAL MICROSCOPY TROCHANTER OF FRONT LEG Confocal microscopy: DAVID NEFF LAURA QUIMBY FAITH FRAZIER CONVERTING CONFOCAL MODELS OF EXOSKELETON TO MODELS FOR FINITE ELEMENT ANALYSIS TROCHANTER OF HINDLEG CLAY FLANNIGAN, CASE WESTERN PEGLEG EXPERIMENTS: PHYSIOLOGY AND FINITE ELEMENT ANALYSIS STUDIES PEG LEG TESTS ON HINDLEG Clay Flannigan, Case Western FORCE FLEX FORCE EXTEND RESULTS - RECEPTORS SIGNAL FORCES AS AN ARRAY - SOME GROUPS ARE EXCITED BY EXTERNAL LOAD AND MUSCLE CONTRACTIONS AND CAN PROVIDE POSITIVE FEEDBACK TROCHANTERAL GROUP 3 SENSILLA ENCODE FORCED FLEXIONS: PHYSIOLOGY ABLATION EXPERIMENTS STRAINS PRODUCED BY EXTENSOR MUSCLE CONTRACTIONS: SOME GROUPS CAN MEDIATE POSITIVE FEEDBACK POSITIVE FEEDBACK DECLINES AS LEG IS EXTENDED STRAINS DURING STANCE PHASE: S. Ramasubramanian, G. Nelson, Case Western Fy Fz Fx Femur and Tibia Attached to Trochanter - FT Joint Angle from Kinematic Studies, Forces applied at Levels (Fx, Fy, Fz) for early, middle and late stance.(Kinematic Data from J. Watson, R. Ritzmann; Force Data from R. Full) STRAINS DURING MIDSTANCE PHASE: S. Ramasubramanian, Case Western LEG LOADING RESULTS -ARRAY ENCODES FORCE DIRECTION (FORCE POSTERIOR, FLEXION) -ARRAY ENCODES FORCE MAGNITUDE TROCHANTERAL FORCE SENSORS AS LOAD CELL: Fx, Fy and Fz INDEPENDENTLY VARIED ARRAY CAN DETECT INCREASES IN FORCE VECTORS Summary: ENCODING PROPERTIES OF CAMPANIFORM SENSILLA- signal level of load rate of change of force, provide active signal for sudden decreases MODELING THROUGH FINITE ELEMENT ANALYSIS - trochanteral campaniform sensilla encode forces as a array; some groups provide positive feedback in limited ranges of joint angles LEG DESIGN/ANATOMY DETERMINES SPECIFICITY OF AFFERENT INPUTS FEA Modeling Studies:Strain in Exoskeleton 1- Exoskeleton is a tubular structure that is rigid (modulus =3160 N/mm^2); fixed beam analysis is useful 2- Receptors located on proximal ends of segments and are subject to large bending forces when end of leg is pushed against substrate TIBIAL EXTENSOR MUSCLE TIBIAL SENSILLA TROCHANTERAL EXTENSOR MUSCLE TROCHANTERAL SENSILLA 3- Strains also result from muscle contractions: • Muscles with insertions near receptors produce strains; locally distribution depends upon shape • Muscles located close to body can produce bending along length of leg Three Dimensional Reconstruction of Exoskeleton by Confocal Microscopy Converted to FEA Model CLAY FLANNIGAN, ROGER QUINN CASE WESTERN RESERVE FEA MODEL Confocal microscopy: DAVID NEFF LAURA QUIMBY FAITH FRAZIER FORCE RECEPTORS ON TROCHANTER The trochanteral segment contains the largest number of strain sensing campaniform sensilla in the leg. These receptors have been characterized physiologically and their responses have been modeled by Finite Element Analysis. The trochanteral receptors can provide precise information about the magnitude, direction and rate of forces applied to the femur. Insect-Like Hexapods •Robot II - “stick insect” •6 symmetric 3 DOF Legs - 18DOF •Locomotion controller Robot II uses network of inter-leg •Robot III - cockroach influences •Pneumatic actuation •Able to walk over rough and unstable terrain •24 DOF: 5 front, 4 middle, 3 rear Robot III •Currently shows high Cockroach Anatomy •5 leg segments: coxa, trochanter, femur, tibia, tarsus •CT, FT are 1 DOF, hinge-like and articulate about 2 condyles •Large muscles of the coxa insert on the trochanter Coxa Tibia Tarsus Femur Trochanter Cockroach Leg Muscle Definition Trochanter •Approximately 2.5 mm in length for the adult P. americana •Outer surface is smooth; inner surface has variable topology Dorsal Coxal Condyles •Coxa attaches via 2 condyles on the anterior Femur and Distalposterior sides Proximal y •Femur attachesFemoral viaCondyles 2 condyles on the distal Trochanter x anterior surface Anterior view trochanter Ventral Campaniform Sensilla •Campaniform Sensilla (CS) are cuticular caps in the exoskeleton innervated by a single nerve •Ellipsoidal with longaxis length from 6 to 24 mm Cuticle Cap Dendrite Sensory Neuron Axon Campaniform sensilla structure Trochanteral Campaniform Sensilla •CS found in 6 groups on the leg (10-15 in a group) •Within groups the CS are similarly oriented •4 groups on the trochanter Group 3 Group 4 Group 2 Anterior campaniform sensilla groups Group 1 Posterior campaniform sensilla group Confocal Modeling (Zill Lab) •Confocal microscope used to optically section the trochanter •Irradiation of the specimen with UV Light causes the cuticle to fluoresce •Microscope indexes its focal plane through the trochanter •Result: A series of bitmap images, when combined using specialized software, creates 3-D model of the trochanter Confocal Sections Meshed Trochanter Thickness Scale: red 6mm blue 265mm Anterior Posterior Trochanter-Femur Model Forced Flexion Anterior •Von Mises strain: 2 Posterior VM 1/ 2(( x y ) ( y z ) 2 ( z x ) 2 ) 3( 2xy 2yz 2zx ) STRUCTURE AND LOCATION OF CAMPANIFORM SENSILLA FUNCTION LIKE STRAIN GAUGES DETECT STRAIN IN EXOSKELETON COMPRESSIONS PERPENDICULAR TO CAP LONG AXIS EXCITE RECEPTOR TROCHANTERAL CAMPANIFORM SENSILLA: IMAGING BY CONFOCAL MICROSCOPY 1) OCCUR AS FOUR GROUPS (Gp1-4) 2) EACH GROUP HAS CONSISTENT ORIENTATION 3) GROUPS ARE ASSOCIATED WITH INTERNAL BUTTRESSES OR THICKENINGS OF EXOSKELETON OUTER SURFACE INNER SURFACE CONFOCAL IMAGES OF CUTICLE diI OUTFILL THREE DIMENSIONAL RECONSTRUCTION OF EXOSKELETON BY CONFOCAL MICROSCOPY Confocal microscopy: DAVID NEFF LAURA QUIMBY FAITH FRAZIER TROCHANTER OF FRONT LEG ACCURACY CONFIRMED BY SECTIONING MODEL/ORIGINAL TROCHANTER 3D RECONSTRUCTION SEM CONFOCAL and FEA models Confocal model FEA model Overlay comparison ACTIVITIES OF CAMPANIFORM SENSILLA ARE EVALUATED BY STRAINS AT LOCATION OF CUTICULAR CAPS - nodes corresponding to CS are located on the finite element model - Compressions (negative strain values) excite receptors Group 1, posterior trochanter Groups 2,3,4, anterior trochanter FEA PEGLEG EXPERIMENT BEHAVIORAL PARADIGM ATTACH PEG LEG PHYSIOLOGY PARADIGM BEND FEMUR SENSORY RECORDING FEA PEGLEG APPLY FORCES TO ATTACHED FEMUR, POINTS OF MUSCLE INSERTIONS PEG LEG TEST ON Blaberus Discoidalis FRONT LEG FORCE FLEX Group 3 short axis strain FORCE EXTEND Group 4 short axis strain RESULTS: Campaniform Sensilla - Function as a strain gauge array signals forces in all directions of load - Can provide positive feedback FINITE ELEMENT MODELLING OF STRAINS DURING WALKING Fz Fy Fx High speed video: Adam Noah Angela Ridgel Mid-stance Late stance SENSORY ACTIVATION PATTERNS DUE TO GROUND REACTION FORCES DURING STANCE Mid Stance 1.00E-03 8.00E-04 Short Axis Strain 6.00E-04 4.00E-04 2.00E-04 0.00E+00 -2.00E-04 0 1 2 3 4 5 -4.00E-04 -6.00E-04 -8.00E-04 -1.00E-03 Group •Groups 1 and 4 show excitation due to ground reaction forces throughout stance. •These sensilla groups could be responsible for signaling that leg is on substrate and bearing load.