* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Uninterruptible Power Supply Unit for Universal Use QUINT
Ground (electricity) wikipedia , lookup
Electric power system wikipedia , lookup
Electrification wikipedia , lookup
Current source wikipedia , lookup
Electrical substation wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Audio power wikipedia , lookup
Power over Ethernet wikipedia , lookup
Stray voltage wikipedia , lookup
Power engineering wikipedia , lookup
Three-phase electric power wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Power inverter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power MOSFET wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Schmitt trigger wikipedia , lookup
Voltage regulator wikipedia , lookup
Distribution management system wikipedia , lookup
Alternating current wikipedia , lookup
Surge protector wikipedia , lookup
Voltage optimisation wikipedia , lookup
Buck converter wikipedia , lookup
Power supply wikipedia , lookup
Mains electricity wikipedia , lookup
Uninterruptible Power Supply Unit for Universal Use QUINT-BUFFER/24DC/20 1. Short Description Maintenance-Free Buffer Modules for Buffering Power Failures – Completely maintenance-free due to the capacitorbased energy storage device – Narrow design saves space on the DIN rail – Maximum system availability through reliable signaling – Increased buffer time for critical devices With QUINT BUFFER buffer modules, back-up power is stored in capacitors that are completely maintenance-free. The modules extend the mains buffering time of the power supply for 200 ms at 20 A, and for even longer with a lower current consumption. According to statistics, this solution addresses 80% of all mains failures. The buffer module also has increased energy capacity for peak load demands. In addition, modules can be connected in parallel to extend the buffer time. The devices have a narrow and uniform design, which makes them ideal for use on the DIN rail where space is limited. In addition, short wiring paths ensure order and clarity in the control cabinet. The power status must be determined quickly so that the right decision can be made in an emergency. Optimum signaling is thus required for maximum system availability. A floating PDT contact and an LED are provided for function monitoring. The connected devices can be divided into buffered and unbuffered loads using the isolated input. This extends the buffer time, which depends on the output current. If only fused, critical devices are protected, the buffer time is increased significantly. In addition, the isolated input protects the connected devices against errors in the internal network. Uninterruptible Power Supply Unit for Universal Use – QUINT-BUFFER/24DC/20 2. Technical Data 125 mm (4.921 in.) In p u t 130 mm (5.118 in.) O u tp u t P o w e r G o o d 64 mm (2.520 in.) QUINT-BUFFER/24DC/20 Buffer Module Solid Stranded [mm2] Input Output Signal 0.5 - 16 0.5 - 16 0.2 - 2.5 Torque AWG [Nm] 0.5 - 10 20 - 6 0.5 - 10 20 - 6 0.2 - 2.5 25 - 14 1.2 - 1.5 1.2 - 1.5 0.5 - 0.6 [lb in] 10.6 - 13.3 10.6 - 13.3 4.5 - 5.3 UuF 10 mm L [mm] (0.39 in.) 7 mm (0.28 in.) Description Type Order No. Uninterruptible power supply unit, with maintenance-free capacitor-based energy storage device QUINT-BUFFER/24DC/20 28 66 21 3 Technical Data Input Data 1 Input voltage range Maximum input voltage Protection against polarity reversal Transient surge protection Current consumption Suppressor diode (no load/charging/maximum) Charging time Charging delay Switching threshold (fixed/variable) Input fuse Output Data 2 Nominal output voltage Output voltage range Buffer voltage Nominal output current Output current limit in buffer mode Maximum transit current Buffer time Internal At 40°C (104°F) At 70°C (158°F) Uout = 24 V/Iout = 20 A Uout = 24 V/Iout = 1 A Shutdown (buffer mode) Power dissipation (ready/buffer mode) at 27 A Level of efficiency at 27 A Residual ripple (buffer mode) Can be connected in parallel to increase the buffer time Can be connected in parallel for redundancy Internal surge protection Resistance to return supply in buffer mode Signal Output Data Power Good active (High = buffer module charged) LED 6(flashing: buffer module charging) 24 V DC 22.5 - 30 V DC Yes 35 V DC 0.1 A/0.6 A/20.6 A < 27 s No < 22 V DC/(UIN - 1 V)/0.1 s Yes 24 V DC 22 - 28.5 V DC UIN - 0.8 V and > 22.0 V 20 A 27 A 27 A 20 A 0.2 s 4s > 4.5 s 2.5 W/9.8 W > 95% < 100 mVpp Yes Yes 35 V DC < 35 V DC +24 V/20 mA Yes Green LED Pcs. Pkt. 1 Uninterruptible Power Supply Unit for Universal Use – QUINT-BUFFER/24DC/20 Approvals/Standards Electrical equipment of machines (Surge Voltage Category III) Safety transformers for switched-mode power supply units Electrical safety (of IT equipment) Industrial control equipment CB scLheme B EN 60 204 EN 61 558-2-17 EN 60950/VDE 0805, UL/C-UL Recognized UL 60 950 u UL/C-UL Listed UL 508 U LISTED Shipbuilding Electronic equipment for use in electrical power installations Safety extra-low voltage Protection against electric shock, basic requirements for safe isolation in electrical equipment Germanischer Lloyd F EN 50 178/VDE 0160 PELV (EN 60 204)/SELV (EN 60 950) DIN VDE 0106-101 General Data Insulation voltage input/output to housing: Type test/routine test Degree of protection Class of protection MTBF Housing version Dimensions (W x H x D) + DIN rail (without PE connection) According to IEC 1709 (SN 29 500) AluNox (AlMg1), closed Weight Climatic Data Ambient temperature Humidity Vibration Approximately Operation Storage At +25°C (+77˚F), no condensation According to IEC 68-2-6 Shock (in all space directions) Pollution degree Climatic category According to IEC 68-2-27 According to EN 50 178 According to EN 60 721 1 kV/1 kV IP20 III > 500,000 h Yes (64 x 130 x 125 mm [2.520 x 5.118 x 4.921 in.]) (122 x 130 x 67 mm [4.803 x 5.118 x 2.638 in.]) 1 kg -25°C to +70°C (-13˚F to +158˚F) -40°C to +85°C (-40˚F to +185˚F) ≤ 95% < 15 Hz, amplitude ±2.5 mm 15 Hz - 150 Hz, 2.3g, tV = 90 minutes 30g 2 3K3 c Conformance With EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC EMC (Electromagnetic Compatibility) Noise Immunity According to EN 61000-6-2 • EN 61000-4-22) Electrostatic discharge (ESD) • EN 61000-4-31) Electromagnetic HF field • EN 61000-4-42) Fast transients (burst): • EN 61000-4-52) Surge current loads (surge): • EN 61000-4-61) Conducted interference Housing Contact discharge: Air discharge: Housing Frequency/field Input, output: Signal: Input, output, signal: I/O/S: Frequency/U0: Noise Emission According to EN 50081-2 • Radio interference emission • Radio interference voltage EN 55011 corresponds to CISPR11/EN 55022 corresponds to CISPR22/EN 61000 corresponds to IEC 1000 1) Criterion A: Normal operating characteristics within the specified limits. 2) Criterion B: Temporary adverse effects on the operating characteristics that the device corrects automatically. 3) Symmetrical: Cable to cable. 4) Asymmetrical: Cable to ground. 5) Class B: Industrial and domestic applications. QUINT-BUFFER/24DC/20 Level 4 8 kV 15 kV Level 3 80 - 1000 MHz/10 V/m 2 kV (Level 3)4) 1 kV (Level 2)4) 0.5 kV4)/0.5 kV3)/(Level 1) Level 3 0.15 - 80 MHz/10 V EN 55011 (EN 55022) Class B5) EN 55011 (EN 55022) Class B5) Uninterruptible Power Supply Unit for Universal Use – QUINT-BUFFER/24DC/20 3. Device View, Connections, and Control Elements QUINT BUFFER 3 – /20 DC .6A /24 3 C/0DC ER 21 FF 66 VD 0V 24.5-3 /20A BU 8 T o.: 2 2 2 DC IN N e: 24V A QUderg s/1 lta Or 3.6 Vo al ut: on Inperati : Optput: ime T Ouffer Bu GN D Po w Go er od Po w Go er od °C 70 F + 54 ° 5…+1 2 0 95 3… 60 04 -17 -1 EN 02 8-2 od o rG we Po 6 5 EN 615 EN 5 –2 L IA S AL STRL OV INDUTROENT PR AP DC 2 In 4 V pu t + – 1 U BF 6000 1 61 81EN 500 EN N M COUIP EQKA 43 D 20 A O ut pu + LIS t – TE n tio la g al s t tin i n nec n d a co R e ore f be in st ru ct i S AB www.interface.phoenixcontact.com – 4 2 s on 2 Figure 04 1 DC input: 24 V unbuffered 24 V DC input voltage (0.5 mm2 to 16 mm2 solid) (0.5 mm2 to 10 mm2 stranded) (20 - 6 AWG) Internal fuse 2 DC output: 24 V buffered 24 V DC output voltage (0.5 mm2 to 16 mm2 solid) (0.5 mm2 to 10 mm2 stranded) (20 - 6 AWG) The device is idling-proof and short-circuit-proof. 3 Green LED: Power Good 4 Active switching output: Power Good 5 Universal DIN rail adapter UTA 107 4. Safety Notes and Warning Instructions To ensure that the device can be operated safely and all functions can be used, please read these instructions carefully. Caution: Never carry out work when the power is turned on, this is highly dangerous. QUINT BUFFER is a built-in device. Installation and startup must only be carried out by qualified personnel. The relevant country-specific regulations (e.g., VDE, DIN) must also be observed. Before startup it is particularly important to ensure that: • All supply lines have sufficient fuse protection and are the correct size. • All output cables are the correct size for the maximum device output current or have separate fuse protection. • Sufficient convection is ensured. Uninterruptible Power Supply Unit for Universal Use – QUINT-BUFFER/24DC/20 5. Installation 5.1. Mounting The buffer module can be snapped onto all DIN rails according to EN 60715 and should be mounted horizontally (input terminal blocks facing downwards). Installation Dimensions QUINT BUFFER – /20 DC .6A /24 3 C/0DC ER 21 FF 66 VD 0V 24.5-3 /20A BU 28 T 2 C IN No.: :2 D QU erge 24Vs/1A lta rd O 3.6 Vo al ut: tion p In era : Optput: ime T Ouffer Bu GN D Po w Go er od Po w Go er od °C 70 + 54 °F 5…+1 0 -2 … 95 3 60 04 -17 -1 EN 02 8-2 d oo rG we Po 6 5 EN 615 EN 5 –2 L IA S AL STRL OV INDUTROENT N M PR COUIP AP EQ A DC 2 In 4 V pu t + – U t – 0-6 00 61 81-1 EN 500 EN K ED ST LI 20 A O ut pu + 43 BF n ti o ll a g s ta tin in nec a d con R e re fo be in s tr uc ti o S AB www.interface.phoenixcontact.com – No minimum spacing to other modules is required for proper operation of the device. -2 ns Figure 05 5.2. Narrow Mounting Position The device is supplied ready for installation in a narrow mounting position. Mounting: Place the module with the DIN rail guideway on the top edge of the DIN rail and then snap it downwards. Removal: Release the snap-on catch using a screwdriver and then detach the module from the bottom edge of the DIN rail. 5.3. Flat Mounting Position A flat mounting position can be achieved by mounting the module onto the DIN rail at a 90° angle. To do this, mount the DIN rail adapter (UTA 107) 7 as shown in Figure 07. No additional assembly material is required. Mounting screws: Torx T10 (torque 0.8 - 0.9 Nm). Mounting Removal Figure 06 Figure 07 Uninterruptible Power Supply Unit for Universal Use – QUINT-BUFFER/24DC/20 a) AC QUINT BUFFER Power Supply 4-POL QUINT BUFFER Unbuffered Load 4-POL – DC + Buffered Load – DC + b) AC QUINT BUFFER Power Supply 2-POL QUINT BUFFER Buffered Load 2-POL – DC + 5.4. Connection The following cable cross sections can be connected: 1 Input: 2 Output: 3 Signal: Solid [mm2] 0.5 - 16 0.5 - 16 0.2 - 2.5 Stranded [mm2] 0.5 - 10 0.5 - 10 0.2 - 2.5 AWG 20 - 6 20 - 6 25 - 14 Torque [Nm] 1.2 - 1.5 1.2 - 1.5 0.5 - 0.6 l For reliable and safe-to-touch connections: Strip 10 mm (0.39 in.) from the input and output side connector ends and 7 mm (0.28 in.) from the signal connector ends. To maintain UL approvals, use copper cables, which are designed for operating temperatures > +75°C (+167°F). To meet GL requirements, unused terminal compartments should be closed. 5.5. Input (1, Figure 04, Figure 08) The buffer module is connected to the output of the power supply via the "+" and "-" screw connections of the 24 V DC input (4-pos. connection). The output is isolated from the input by the internal diode. The stored power is only supplied to the output (Fig. 08a). If isolation is not required, the buffer module can also be connected to the power supply as a 2-pos. connection via the "+" and "-" screw connections of the DC output (Fig. 08b). Fuse Further device protection is not required, as an internal fuse is present. If the internal fuse is blown, this is most probably due to a device fault. In this case, the device should be checked in the factory. QUINT BUFFER Figure 08 GN D D /24 3 ER 21 FF 66 2 BU 28 : T . IN No :2 QUderge 2 lta Or 3 Vo al : t n u io Inperat : : Optput ime T Ouffer Bu Po w Go er od Po w Go er od d oo rG we Po 5 –2 L IA S AL STRL OV INDUTROENT PR AP DC 2 In 4 V pu t + – U LIS 20 A O ut pu + t – TE N M COUIP EQKA 43 D t la al s t ti i n nec n d o a c R e ore f be Figure 09 Uninterruptible Power Supply Unit for Universal Use – QUINT-BUFFER/24DC/20 Buffer time [s] 10.0 @ 24 V @ 28.5 V @ 22.5 V 1.0 0.1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Output current [A] 5.6. Output (2, Figure 04, Figure 08, Figure 10) All loads that must be supplied by the power stored in the buffer module in the event of a supply voltage failure ("Buffered Load"), are connected to the "+" and "-" screw connections of the DC output. It is recommended that all other loads, which do not require buffering in the event of a supply voltage failure ("Unbuffered Load"), are connected in parallel to the power supply. This increases the buffer time, as this time depends on the output current (see Figure 10). The internal diode ensures that the buffered loads are isolated from the unbuffered loads. 5.7. Signaling Output The Power Good signal output is connected via the "Power Good" and "GND" screw connections. The 24 V DC signal can be loaded with 20 mA maximum. 6. Method of Operation QUINT BUFFER supplies all connected devices with a regulated 24 V DC voltage without interruption for a load current of up to 20 A. When the 24 V supply voltage is applied, the integrated capacitor-based energy storage device is charged. In the event of a supply voltage failure, the stored power ensures that all connected devices continue to operate without interruption for up to 4 seconds. 6.1. Output Voltage The output voltage of the buffer module corresponds to the usual supply voltage. If the input voltage drops more than 1 V in the space of 0.1 seconds, buffering is enabled and the output voltage is regulated to this 19 20 Figure 10 value. The minimum switching threshold is 22 V. The device is electronically short-circuit-proof and idling-proof. In the event of an error, the output voltage is limited to 35 V. 6.2. Signaling The active signal output and an LED provide function monitoring. The signal output is connected via the "Power Good" and "GND" screw connections. Green LED: "Power Good" 3 ON Flashing Active signal output: "Power Good" 4 U = +24 V (with reference to "GND") • Supply voltage present • Buffer module charged • Buffer module ready U=0V (with reference to "GND") • Supply voltage present, buffer module charging • Supply voltage not present, the power stored in the buffer module (if available) is provided at the output. Meaning/ Description