Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Whole body MRI – How I do it and what it tells you Prof. Anwar Padhani Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, United Kingdom Email: [email protected] The idea of whole body MRI (WB‐MRI), acquiring multiple image stacks across the entire body is not new. Since the 1990s, conventional T1 and short‐tau inversion recovery (STIR) techniques have been investigated as methods for tumor detection [1‐3]. These initial studies did demonstrate relatively high sensitivity, specificity and diagnostic accuracy for malignant lesion detection in a variety of tumor types [1, 2, 4‐8]. However, whole body MRI did not gain widespread acceptance despite its promise of being as accurate as FDG‐PET for malignant lesion detection in the bones [9‐13]. Important negating factors to clinical deployment include the need to use multiple sequences in multiple imaging planes before and after contrast medium. Whole body MRI protocols have to be tailored by tumor type and were time consuming to acquire, view, analyze and report [14, 15]. However, substantial improvements have been made in MR hardware and software innovations, which allow multi‐part MR examinations to be performed with a relative easy workflow [15, 16]. The advent of continuous moving table technology allows even more efficient scanning [7, 16‐19]. Dedicated software enables the imaging data acquired at different anatomical stations and in different imaging planes to be quickly stitched and fused together to facilitate analysis and reporting. Today, most modern state‐of‐the‐art MR scanners, can perform whole‐body MRI from the vertex to the mid‐thighs with T1‐weighted, fat‐suppressed T2‐ weighted or STIR, and diffusion weighted imaging sequences supplemented T1‐weighted and T2W‐weighted spinal images in less than 60 minutes, thus making WB‐MRI a viable clinical tool. A key recent development has been the addition of whole body diffusion weighted (DW) sequences which makes it possible to do away with the need to use IV contrast medium for routine WB‐MRI examinations [20, 21]. WB‐DWI is now considered to be an integral component of WB‐MRI examination that improves reading performance [22]. This is because WB‐DWI it enables “at a glance” assessments, immediately drawing attention to potential abnormal regions and thus helping to reduce image interpretation times of anatomical WB‐MRI [20]. Working whole body MRI protocol without using IV contrast medium Patients are best imaged on a 1.5T system equipped with multiple surface coils. Our imaging studies are done in the following sequence order, after obtaining appropriate whole body scout images. We do not use IV contrast medium injections although the literature suggests that it use may be beneficial for the detection of bone, lungs, liver and brain metastases – see below [23‐ 25]. 1. Whole spine: T1‐weighted, turbo spin‐echo sagittal images. Images are acquired in two stations (cervico‐dorsal spine and lower dorsal with lumbo‐sacral region) and composed into single images for display purposes. TR=180ms, TE=10ms, bandwidth=195Hz/pixel, 11 slices, 4mm slice thickness, 0.8mm gap, echo‐train length =3, refocusing flip angle=180⁰, field of view=342x380cm, matrix 177x256. Total imaging time for both stations= 2:12 minutes. 2. Whole spine: T2‐weighted, turbo spin‐echo sagittal images with spectral fat suppression. Images are acquired in two stations (cervico‐dorsal spine and lower dorsal Proc. Intl. Soc. Mag. Reson. Med. 20 (2012) with lumbo‐sacral region) and composed into single images. TR=4500ms, TE=101ms, bandwidth=252Hz/pixel, acceleration factor=2, 11 slices, 5mm slice thickness, echo‐train length=29, refocusing flip angle=150⁰, field of view=342x380cm, matrix 256x256. Total imaging time for both stations= 2:36 minutes. 3. Whole body: T1‐weighted, gradient‐echo axial images from vertex to upper mid thighs. TR=130ms, TE=4.8/2.4ms, bandwidth=470Hz/pixel, acceleration factor=2, 5mm slice thickness, flip angle=70⁰, field of view=336x430cm, matrix 175x320. Continuous table movement (5.9 mm/s) are used during data acquisition, employing multiple breath‐ holds for the neck, chest and abdomen and shallow breathing for the pelvis and thighs. Total imaging time = 3:00 minutes. 4. Whole body: T2‐weighted, short‐tau inversion recovery (STIR) axial images with half‐ fourier single shot turbo spin echo (HASTE) readouts of the data from vertex to upper mid thighs. TR=1000ms, TE=75ms, Inversion time=170ms, bandwidth=501Hz/pixel, acceleration factor=2, 5mm slice thickness, echo‐train length =208, flip angle=150⁰, field of view=350x430cm, matrix 208x256. Continuous table movement (5 mm/s) are used during data acquisition, employing breath‐holds for the neck, chest and abdomen and shallow breathing for the pelvis and thighs. Total imaging time = 4:00 minutes. 5. Multi‐station WB‐DWI for 1.5T using the machine parameters given in the table below in 4 stations. Machine parameters for WB‐DWI at 1.5T Imaging sequence Free breathing, single shot spin‐echo echo planar imaging Repetition time 9,000ms Echo time 68ms No of slices 200 (4 stations x 50 slices/station) Field of View 450 x 450 cm (variable) Matrix 128 x 128 interpolated to 256 x 256 Number of signal averages 6 Fat suppression scheme Short‐tau inversion recovery (STIR, TI=180ms) Diffusion encoding Trapezoidal gradients, trace weighted, bipolar gradient scheme Parallel imaging factor Grappa, pat factor 2, 30 reference lines Section thickness/gap 5mm/0mm overlap b‐values (s/mm2) 50 and 900 Receiver bandwidth 1628 Hz/pixel Acquisition time/station 5:51 minutes Proc. Intl. Soc. Mag. Reson. Med. 20 (2012) 6. Diffusion weighted b900 images from all 4 diffusion imaging stations are grouped and reconstructed as axial and coronal 5mm slices. Whole body 3D‐maximum intensity projection of b900 images are displayed as rotating images (every 3 degrees=120 images) using an inverted grey‐scale. 7. The ADC for all slices is calculated using the two b‐values obtained monoexponential fitting of log signal intensity (SI) versus b values: S900 = S50 × exp (− b × ADC), where S900 is the signal intensity at b of 900 s/mm2 and S50 is the signal intensity at b of 50 s/mm2 (the ADC represents the slope of the curve). Lesion detection with whole body MRI with WB‐DWI – a brief review of the literature The ability of WB‐MRI to detect lesions is highly dependent on tumor histological type and grade as well as on anatomic location. Thus, in our experience detection ability is good for breast cancers, myeloma and lymphoma and for tumors with highly packed small cancer cells such as neuroendocrine tumors, small cell cancers and many childhood tumors [26‐30]. Metastatic diseases from these tumor types generally appear bright on high b‐value DW images. In contradistinction, primary tumors and metastases from renal cancers are sometimes less well seen, with clear cell metastases appearing relatively less conspicuous compared to other renal cancer histological subtypes; this may be related to the relatively greater water diffusivity in the clear cell cancers [31‐34]. Furthermore, it has been noted that well‐differentiated or low‐grade masses are less well seen probably because they often have a more normal appearing histomorphic structure [33, 35‐39]. The latter point is not a hard and fast rule because many cytological features aside from cellular density determine tumor grade. There are several anatomic “blind spots” where lesion detection is impaired (leading to false negative results) including the mediastinum, at the pulmonary hila and in the most cranial aspect of the left hepatic lobe just beneath the heart. At these sites, complex incoherent motion contributes to signal losses on high b‐value DW images. Motion‐related signal intensity losses may explain why metastatic lesions in the bone marrow of the anterior chest wall are sometimes relatively less conspicuous than lesions found in the spine & paraspinal regions. Lastly, small lung metastases are poorly shown on WB‐DWI although a sensitivity analysis by lesion size has not been done. The ability to detect lung metastases appears to improve by the use of contrast medium but not to the detection level of CT [40, 41]. The literature suggests that contrast enhancement may also be beneficial for the detection of bone, liver and brain metastases [23‐25, 41]. On the other hand, FDG‐PET and MRI have been found to be comparable at lesion detection in the bone marrow and both significantly more accurate than CT and BS for the diagnosis of bone metastases [9, 27, 42, 43] in a variety of cancers including lung cancer. MRI performance exceeds FDG‐PET in detecting bony metastases in breast cancer patients [44]. For example, a recent meta‐analysis demonstrated a high pooled sensitivity of 0.899 (95% CI, 0.845– 0.939) and high specificity of 0.918 (95% CI, 0.882–0.946) [8]. A sub‐group analysis found that addition of DWI decreased the specificity of WB‐MRI in bone metastases detection; the subgroup of WB‐MRI without DWI had higher pooled specificity (0.961, 95% CI 0.922–0.984) than the subgroup of WB‐MRI without DWI (0.861, 95% CI 0.792–0.914) (P < 0.05) [8]. Causes of false positive increases in bone marrow signal intensity on DWI images include bone marrow edema caused by fractures, degenerative diseases, bone infarction, infection and hemangiomas. Other causes of false positive focal increases in signal intensity on DWI include Proc. Intl. Soc. Mag. Reson. Med. 20 (2012) isolated red bone marrow islands within yellow marrow and treated, but inactive lesions (T2‐ shine through). Many of these false positive increases in signal intensity on high b‐value images can overcome by performing image interpretations with ADC maps and conventional images. Causes of false negative results in the bone marrow tumor detection include low levels of tumor infiltration, skull vault and skull base metastases (due to the adjacent high signal intensity of the brain) and when metastases develop within hypercellular bone marrow. As a general rule, lytic bony metastases are better seen than pure sclerotic metastases because of lower water and cellular content of sclerotic and treated lesions [23, 27, 45]. References 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Eustace S, Tello R, DeCarvalho V, Carey J, Melhem E, Yucel EK. Whole body turbo STIR MRI in unknown primary tumor detection. J Magn Reson Imaging 1998; 8:751‐753. Steinborn MM, Heuck AF, Tiling R, Bruegel M, Gauger L, Reiser MF. Whole‐body bone marrow MRI in patients with metastatic disease to the skeletal system. J Comput Assist Tomogr 1999; 23:123‐129. Lauenstein TC, Freudenberg LS, Goehde SC, et al. Whole‐body MRI using a rolling table platform for the detection of bone metastases. Eur Radiol 2002; 12:2091‐2099. Ghanem N, Lohrmann C, Engelhardt M, et al. Whole‐body MRI in the detection of bone marrow infiltration in patients with plasma cell neoplasms in comparison to the radiological skeletal survey. Eur Radiol 2006; 16:1005‐1014. Herborn CU, Unkel C, Vogt FM, Massing S, Lauenstein TC, Neumann A. Whole‐body MRI for staging patients with head and neck squamous cell carcinoma. Acta Otolaryngol 2005; 125:1224‐1229. Brennan DD, Gleeson T, Coate LE, Cronin C, Carney D, Eustace SJ. A comparison of whole‐body MRI and CT for the staging of lymphoma. AJR Am J Roentgenol 2005; 185:711‐716. Engelhard K, Hollenbach HP, Wohlfart K, von Imhoff E, Fellner FA. Comparison of whole‐ body MRI with automatic moving table technique and bone scintigraphy for screening for bone metastases in patients with breast cancer. Eur Radiol 2004; 14:99‐105. Wu LM, Gu HY, Zheng J, et al. Diagnostic value of whole‐body magnetic resonance imaging for bone metastases: a systematic review and meta‐analysis. J Magn Reson Imaging. 2011; 34:128‐135. Yang HL, Liu T, Wang XM, Xu Y, Deng SM. Diagnosis of bone metastases: a meta‐analysis comparing (1)FDG PET, CT, MRI and bone scintigraphy. Eur Radiol 2011; 21:2604‐2617. Heusner T, Golitz P, Hamami M, et al. "One‐stop‐shop" staging: should we prefer FDG‐ PET/CT or MRI for the detection of bone metastases? Eur J Radiol 2011; 78:430‐435. van Ufford HM, Kwee TC, Beek FJ, et al. Newly diagnosed lymphoma: initial results with whole‐body T1‐weighted, STIR, and diffusion‐weighted MRI compared with 18F‐FDG PET/CT. AJR Am J Roentgenol 2011; 196:662‐669. Pfannenberg C, Schraml C, Schwenzer N, et al. Comparison of [68Ga]DOTATOC‐PET/CT and whole‐body MRI in staging of neuroendocrine tumors. Cancer Imaging 2011; 11:S38‐39. Kwee TC, Takahara T, Ochiai R, et al. Complementary roles of whole‐body diffusion‐ weighted MRI and 18F‐FDG PET: the state of the art and potential applications. J Nucl Med 2010; 51:1549‐1558. Proc. Intl. Soc. Mag. Reson. Med. 20 (2012) 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. Schaefer JF, Schlemmer HP. Total‐body MR‐imaging in oncology. Eur Radiol 2006; 16:2000‐2015. Schmidt GP, Reiser MF, Baur‐Melnyk A. Whole‐body MRI for the staging and follow‐up of patients with metastasis. Eur J Radiol 2009; 70:393‐400. Kruger DG, Riederer SJ, Grimm RC, Rossman PJ. Continuously moving table data acquisition method for long FOV contrast‐enhanced MRA and whole‐body MRI. Magn Reson Med 2002; 47:224‐231. Bornert P, Aldefeld B. Principles of whole‐body continuously‐moving‐table MRI. J Magn Reson Imaging 2008; 28:1‐12. Han Y, Weigel M, Huff S, Ludwig U. Whole‐body diffusion‐weighted imaging with a continuously moving table acquisition method: Preliminary results. Magn Reson Med 2011. Schaefer AO, Langer M, Baumann T. Continuously moving table MRI in oncology. Rofo 2010; 182:954‐964. Kwee TC, Takahara T, Ochiai R, et al. Whole‐body diffusion‐weighted magnetic resonance imaging. Eur J Radiol 2009; 70:409‐417. Padhani AR, Koh DM, Collins DJ. Whole‐Body Diffusion‐weighted MR Imaging in Cancer: Current Status and Research Directions. Radiology 2011; 261:700‐718. Fischer MA, Nanz D, Hany T, et al. Diagnostic accuracy of whole‐body MRI/DWI image fusion for detection of malignant tumours: a comparison with PET/CT. Eur Radiol 2011; 21:246-255. Northam M, de Campos RO, Ramalho M, et al. Bone metastases: evaluation of acuity of lesions using dynamic gadolinium‐chelate enhancement, preliminary results. J Magn Reson Imaging 2011; 34:120‐127. Costelloe CM, Kundra V, Ma J, et al. Fast dixon whole‐body MRI for detecting distant cancer metastasis: A preliminary clinical study. J Magn Reson Imaging 2011. Thomson V, Pialat JB, Gay F, et al. Whole‐body MRI for metastases screening: a preliminary study using 3D VIBE sequences with automatic subtraction between noncontrast and contrast enhanced images. Am J Clin Oncol 2008; 31:285‐292. Chen W, Jian W, Li HT, et al. Whole‐body diffusion‐weighted imaging vs. FDG‐PET for the detection of non‐small‐cell lung cancer. How do they measure up? Magn Reson Imaging 2010; 28:613‐620. Messiou C, Collins DJ, Morgan VA, Desouza NM. Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility. Eur Radiol 2011; 21:1713‐1718. Abdulqadhr G, Molin D, Astrom G, et al. Whole‐body diffusion‐weighted imaging compared with FDG‐PET/CT in staging of lymphoma patients. Acta Radiol 2011; 52:173‐ 180. Heusner TA, Kuemmel S, Koeninger A, et al. Diagnostic value of diffusion‐weighted magnetic resonance imaging (DWI) compared to FDG PET/CT for whole‐body breast cancer staging. Eur J Nucl Med Mol Imaging 2010; 37:1077‐1086. Kwee TC, Takahara T, Vermoolen MA, Bierings MB, Mali WP, Nievelstein RA. Whole‐ body diffusion‐weighted imaging for staging malignant lymphoma in children. Pediatr Radiol 2010. Wang H, Cheng L, Zhang X, et al. Renal Cell Carcinoma: Diffusion‐weighted MR Imaging for Subtype Differentiation at 3.0 T1. Radiology 2010; 257:135‐143. Paudyal B, Paudyal P, Tsushima Y, et al. The role of the ADC value in the characterisation of renal carcinoma by diffusion‐weighted MRI. Br J Radiol 2010; 83:336‐343. Proc. Intl. Soc. Mag. Reson. Med. 20 (2012) 5 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. Sandrasegaran K, Sundaram CP, Ramaswamy R, et al. Usefulness of diffusion‐weighted imaging in the evaluation of renal masses. AJR Am J Roentgenol 2010; 194:438‐445. Manenti G, Di Roma M, Mancino S, et al. Malignant renal neoplasms: correlation between ADC values and cellularity in diffusion weighted magnetic resonance imaging at 3 T. Radiol Med (Torino) 2008; 113:199‐213. Woodfield CA, Tung GA, Grand DJ, Pezzullo JA, Machan JT, Renzulli JF, 2nd. Diffusion‐ weighted MRI of peripheral zone prostate cancer: comparison of tumor apparent diffusion coefficient with Gleason score and percentage of tumor on core biopsy. AJR Am J Roentgenol 2010; 194:W316‐322. Tamada T, Sone T, Jo Y, et al. Apparent diffusion coefficient values in peripheral and transition zones of the prostate: Comparison between normal and malignant prostatic tissues and correlation with histologic grade. J Magn Reson Imaging 2008; 28:720‐726. Turkbey B, Shah VP, Pang Y, et al. Is Apparent Diffusion Coefficient Associated with Clinical Risk Scores for Prostate Cancers that Are Visible on 3‐T MR Images? Radiology 2011; 258:488‐495. Hambrock T, Somford DM, Huisman HJ, et al. Relationship between Apparent Diffusion Coefficients at 3.0‐T MR Imaging and Gleason Grade in Peripheral Zone Prostate Cancer. Radiology 2011; 259:453‐461. Inada Y, Matsuki M, Nakai G, et al. Body diffusion‐weighted MR imaging of uterine endometrial cancer: is it helpful in the detection of cancer in nonenhanced MR imaging? Eur J Radiol 2009; 70:122‐127. Platzek I, Zastrow S, Deppe PE, et al. Whole‐body MRI in follow‐up of patients with renal cell carcinoma. Acta Radiol 2010; 51:581‐589. Yi CA, Shin KM, Lee KS, et al. Non‐small cell lung cancer staging: efficacy comparison of integrated PET/CT versus 3.0‐T whole‐body MR imaging. Radiology 2008; 248:632‐642. Gutzeit A, Doert A, Froehlich JM, et al. Comparison of diffusion‐weighted whole body MRI and skeletal scintigraphy for the detection of bone metastases in patients with prostate or breast carcinoma. Skeletal Radiol 2010; 39:333‐343. Qu X, Huang X, Yan W, Wu L, Dai K. A meta‐analysis of (18)FDG‐PET‐CT, (18)FDG‐PET, MRI and bone scintigraphy for diagnosis of bone metastases in patients with lung cancer. Eur J Radiol 2011. Liu T, Cheng T, Xu W, Yan WL, Liu J, Yang HL. A meta‐analysis of 18FDG‐PET, MRI and bone scintigraphy for diagnosis of bone metastases in patients with breast cancer. Skeletal Radiol 2011; 40:523‐531. Eiber M, Holzapfel K, Ganter C, et al. Whole‐body MRI including diffusion‐weighted imaging (DWI) for patients with recurring prostate cancer: Technical feasibility and assessment of lesion conspicuity in DWI. Journal of Magnetic Resonance Imaging 2011; 33:1160‐1170. Proc. Intl. Soc. Mag. Reson. Med. 20 (2012) 6