Dentomaxillofacial Radiology DMFR 174—14/11/2006—11:19——235188 Dentomaxillofacial Radiology (2007) 36, 1–6 q 2007 The British Institute of Radiology http://dmfr.birjournals.org RESEARCH Transtomography for implant placement guidance in non-invasive surgical procedures F Bousquet*,1, P Bousquet2 and L Vazquez3 1 3 Private Practice, Montpellier, France; 2Department of Perio Implantology, University of Montpellier, Montpellier, France; Department of Stomatology, Oral Surgery and Dentomaxillofacial Radiology, University of Geneva, Geneva, Switzerland Objectives: To illustrate the use of transtomography for the placement of implants using a radiopaque radiographic guide and to evaluate the accuracy of transtomography. Methods: The study included 11 implants inserted with minimally invasive procedures. Pre-, intraand post-operative examinations were performed with a ProMax panoramic unit implemented with transtomographic technique (Planmeca Oy, Helsinki, Finland). At each implant site, cross-sectional and longitudinal intraoperative transtomograms were taken through a radiopaque reference guide to control and adjust the drilling axis. The effective axis on post-operative transtomograms was compared with the planned axis correction estimated on intraoperative images. Radiopaque guides, used as the gold standard, were measured on intraoperative cross-sectional slices to evaluate image distortion. Results: Intraoperative transtomograms, with the reference guide inserted in the bone, gave clear images of the cortical plates and accurate information of drilling length and axis which allowed the surgeon to adjust pilot drilling axis in 6/11 (54.5%) sites, including sites with narrow bone ridges. The implant axis on the post-operative tomogram compared with the planned axis correction showed an angle difference ranging from 0.88 to 3.48. The image distortion on cross-sectional slices ranged from 0.03 mm to 0.52 mm, resulting in a distortion ratio ranging from 0% to 6% when expressed in percentages. Conclusions: Transtomographic examination performed with a radiographic reference guide during implant surgery can provide the necessary and accurate information for implant placement. Transtomography distortion appears to be less important than in other conventional tomographic systems and comparable with CT scan distortion. Dentomaxillofacial Radiology (2007) 36, 1–6. doi: 10.1259/dmfr/91082519 Keywords: dental implants, tomography, distortion, mandible Introduction Various imaging techniques, including conventional radiography and CT, are used for the pre-surgical planning of implant placement. Conventional tomography is the method of choice to obtain cross-sectional information of small regions of interest for implant planning.1 Tomograms before dental implant placement will help determine the height, width, inclination and undercut of the alveolar bone, as well as the location of anatomical structures such as the mandibular canal, the submandibular gland fossa, the maxillary sinus and the nasal fossa.2,3 Cross-sectional images, using films or photostimulable phosphor (PSP) plates obtained with panoramic radiographic units, showed similar image performance and are acceptable for dental Q1 *Correspondence to: Frédéric Bousquet; E-mail: [email protected] Received 30 November 2005; revised 3 May 2006; accepted 18 June 2006 implant placement planning.4 In a study on phantom heads, Welander et al5 tested transtomography, which employs the narrow beam of an advanced direct digital panoramic machine. They showed that this new tomographic scanning technique, which cannot be used in other panoramic units with a sensor technique, gave images with properties comparable with those of conventional tomography. In conventional implant placement surgery, a large full-thickness periosteal flap is reflected to visualize the bone contour before drilling, whereas flapless and minimally invasive procedures maintain a better blood supply to the site by leaving the periosteum intact on the buccal and lingual aspects of the ridge.6,7 However, these “blind” procedures make it more difficult to evaluate the shape of the alveolar bone; as the risk of cortical plate perforation is increased, flapless surgery is limited to straightforward cases with a favourable bone crest.8 – 10 DMFR 174—14/11/2006—11:19——235188 Transtomography and implants Frédéric Bousquet et al 2 The aim of this article is to illustrate how transtomography, when used with a radiopaque radiographic guide, can assist the surgeon during implant placement. The protocol developed in the present study allowed to evaluate the accuracy of transtomography. Methods Between January and October 2005, nine partially edentulous patients (six females and three male patients), age ranging from 31 to 76 years (mean age 53 years), were treated using flapless surgery or a minimally invasive procedure. The implants were inserted in 11 sites (in one incisor site in the maxilla, in seven molar and three premolar sites in the mandible). Pre-operative planning included clinical and radiographic examination. All patients were examined using a ProMax panoramic unit implemented with transtomographic technique (Planmeca Oy, Helsinki, Finland). This digital panoramic unit can make image layer thickness ranging from 1 mm to 36 mm and combines a longitudinal and cross-sectional transtomograms in one composite image. An image layer thickness of 3 mm was chosen for this study. The exposure values were 66 kV, 1 mA and 8 s. Implant position and length were estimated by measuring the crestal width and the distance from the top of the ridge to the critical anatomic structures (cortical plates, undercuts, concavities or mandibular canal) on the panoramic image (1.2 magnification factor) and on a composite image (1.4 magnification factor; Figure 1). All measurements were taken with the computed Planmeca measurement program which allows the calibration of the image on the screen. The ProMax panoramic with transtomographic digital unit offers three picture grabbing modes. The three resolution modes are: normal resolution (one picture pixel equals four physical pixels), enhanced resolution (one picture pixel equals three physical pixels) and high resolution (one picture pixel equals two physical pixels). The size of the physical pixel is 33 mm. After picture calibration Figure 1 Pre-operative longitudinal and cross-sectional transtomograms. The horizontal lines are drawn with the Planmeca program to improve the assessment of critical anatomic structures. The distance from the top of alveolar crest to the lingual undercut is 10 mm. The distance from the top of the alveolar crest to the superior border of the mandibular canal is 13 mm. The occlusal registration key, used to position the patient, is also visible Dentomaxillofacial Radiology for panoramic or transtomographic images (1.2 or 1.4 magnification factor, respectively), measurements were carried out in normal resolution mode (i.e. 132 mm representing the size of four physical pixels), leading to values precised to two decimals. Angle measurements were carried out with the Dimaxis computerized compass program joined to the ProMax panoramic unit, which gave degree values precised to one decimal. Consequently, to ensure accuracy of the measurement system, results were not rounded off. An individualized silicon occlusal registration key was used for patient positioning during pre-, intra- and postoperative transtomography. Throughout surgery, to avoid injury to the inferior alveolar nerve and other critical anatomic zones, the drilling length through the mucosa and the bone before transtomographic control was maintained 2 mm shorter than the estimated distance to these zones. The first drilling, performed with the pilot drill, respected the axis corresponding to the planned implant axis. A custom-made radiopaque radiographic reference guide made of titanium alloy (Ti6Al4V) was inserted in the bone after the first drilling. The reference guide consists of a 2 mm diameter intrabony part, either 5.50 mm or 9.60 mm long. The intrabony part of the 9.60 mm long guides has notches which make it easier to take measurements on the images (Figure 2). The extrabony part of the radiographic guide is 1.5 mm high, 4 mm in diameter and protrudes out of the mucosa. At each implant site, cross-sectional and longitudinal intraoperative transtomograms were taken with the radiopaque reference guide securely sutured to the adjacent teeth or to the surrounding mucosa. The position of the reference guide on the transtomographic images allowed three-dimensional control of the planned surgical drilling trajectory (Figure 3), so the drill’s axis could be adjusted as necessary. After full drilling and enlargement, implants were inserted. Ten implants were Branemark Tiunite Mk3 (Nobelbiocare France, Paris, France) and one was a Replace Select Tapered (Nobelbiocare France). 5/11 (45.4%) implants were 13 mm long, 3/11 (27.3%) implants were 11.5 mm long and 3/11 (27.3%) implants were 10 mm long. Figure 2 Three radiographic reference guides. The intrabony part, with or without notches, measures 9.60 mm for the long guides and 5.50 mm for the short one. The extrabony part may be sutured to the mucosa DMFR 174—14/11/2006—11:19——235188 Transtomography and implants Frédéric Bousquet et al Figure 3 Intraoperative transtomogram showing the axis of the radiopaque reference guide needing an estimated angle correction of 108. The bone height available for full drilling was controlled on the crosssectional view and estimated to 13 mm For the purposes of this study, post-operative transtomography (Figure 4) was used to evaluate the inserted implant; the effective axis of the implant on the postoperative images was compared with the planned axis rectification estimated on intraoperative images. The radiopaque guide, used as the gold standard in this study, was measured on the intraoperative cross-sectional slices to evaluate the image distortion. The measurements were carried out thrice on the screen using the Planmeca program after calibration of the image; the recorded value was the measure having the biggest difference with the gold standard. Measurements of the intrabony part of the reference guide on the slices were compared with the real intrabony length of the guide. Results Comparison of the pre-, intra- and post-operative transtomograms showed no artefact produced by either the titanium guide or the dental implant. Composite images (cross-sectional and longitudinal slices), with optional alignment of the different zones on the two images, improved the visualization of the bone contours and anatomic limits at each site (Figure 1). In 7/11 (63.6%) sites, the crest width was less than 7 mm (ranging from 5.2 mm to 6.5 mm) and a lingual undercut or a buccal concavity was obvious on pre-operative tomograms in 8/11 (72.7%) sites. All intraoperative transtomograms gave clear images of the cortical plates and information of drilling length and Figure 4 Post-operative transtomogram showing the inserted implant with an effective angle correction of 10.88 3 axis which allowed the surgeon to adjust pilot drilling axis in 6/11 (54.5%) sites, including sites with narrow bone ridges. The effective axis of the implant on the postoperative transtomogram, compared with the estimated axis rectification planned when necessary on the intraoperative transtomography, showed an angle difference ranging from 0.88 to 3.48. Post-operative transtomograms confirmed that all implants had been placed as planned and that the implants did not intrude on critical anatomic structures. Measurements of the guide on cross-sectional slices compared with the gold standard showed a distortion ranging from 0.03 mm to 0.52 mm (maximum overestimation 0.03 mm, maximum underestimation 0.52 mm), resulting in a distortion ratio ranging from 0% to 6% when expressed in percentages. Discussion Welander et al5 described how advanced panoramic machines that combine a translational movement with a pendular movement of the beam and detector make direct digital transtomographic images and can be utilized for the same purposes as conventional tomography. Transtomography produces almost instant results and allows quick measurements on the screen with a computed program. This made transtomography more appropriate in our study than conventional tomography using films or PSP plates. In addition, the panoramic machine’s compact size allowed it to be installed in the operating room. The surgeon rapidly and conveniently performed intraoperative investigations in the shortest time (with no discomfort to the patient) as the panoramic machine was within a few paces of the operating table. Positioning of the patient was facilitated by means of the individualized silicon key. The present image distortion (maximum overestimation 0.03 mm, maximum underestimation 0.52 mm) can be compared with other previous studies on distortion using different tomographic systems. In a conventional spiral tomography study on human cadavers, Serhal et al11 used a digital calliper for the measurements and reported a maximum overestimation of measured distances of 1.05 mm and a maximum underestimation of 1.36 mm. The 0% – 6% distortion reported with CT scan12 and the 0% – 5.2% distortion reported with limited cone-beam CT12 are similar to our results with transtomography (distortion ranging from 0% to 6%). As the distortion with transtomography, using a ProMax panoramic unit implemented with transtomographic technique, and the CT scan distortion are similar, transtomography may be considered as an imaging tool providing accurate information for implant planning. In this study, the radiographs were produced with 66 kV, 1 mA, during 8 s and the emitted dose was 51 mGy cm22. Absorbed dose for a composite image (one longitudinal slice and one transversal slice) was 6 mSv – 8 mSv and 3 mSv – 4 mSv for a single slice (information given by the manufacturer, Planmeca Oy). These absorbed doses are comparable with results reported by Lecomber Dentomaxillofacial Radiology DMFR 174—14/11/2006—11:19——235188 Transtomography and implants Frédéric Bousquet et al 4 et al.13 The absorbed dose was 2 mSv for one linear crosssectional tomogram slice and 314 mSv for a CT scan examination. Other previous works showed absorbed doses ranging from 4 mSv to 6.1 mSv for a conventional spiral cross-sectional tomography14 and 3 mSv for one slice of conventional tomography.15 Intraoperative transtomography using a radiographic guide may be considered as a form of navigation surgery; three-dimensional information allows the surgeon to rectify the drill’s axis when needed. We believe it is more flexible than reported navigation surgeries for dental implants needing a CT scan, a computer software and a template for implant guidance.16 – 19 Navigation surgical procedures requiring a CT scan appear to be better suited for large edentulous zones or full arch rehabilitations, whereas a transtomographic navigation protocol, resulting in a reduced absorbed dose, may be considered a safe procedure for implant placement in small edentulous zones. This transtomographic navigation protocol may also improve flapless surgical procedures; currently reported, limitations with these blind procedures are a narrow alveolar ridge and the presence of anatomical undercuts.8 – 10 When an undercut of more than 158 is detected radiologically, or when the width of the ridge is less than 7 mm, flapless procedures are no longer possible; a traditional flap reflection is then recommended to allow better visibility.8 – 10 With a radiographic guide and transtomography, the risks of critical anatomic zones injury and of cortical plate perforation were minimized, allowing implant placement in all cases, including sites presenting a narrow ridge, a buccal concavity or a lingual undercut. In conclusion, transtomographic examination performed with a radiographic reference guide during implant surgery can provide the necessary and accurate information for implant placement. This protocol may be especially valuable during blind surgical procedures as cortical plates or critical anatomic structures may be approached when needed without increasing the risk of damaging them. Distortion of the images appears to be less important than with other conventional tomographic systems and comparable with CT scan distortion. References 1. Dula K, Mini R, Van der Stelt PF, Buser D. A radiographic assessment of implant patients: decision-making criteria. Int J Oral Maxillofac Implants 2001; 16: 80 –89. 2. Tyndall DA, Brooks SL. Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000; 89: 630 – 637. 3. Thunthy KH, Yeadon WR, Nasr HF. An illustrative study of the role of tomograms for the placement of dental implants. J Oral Implantol 2003; 29: 91 –95. 4. Peltola JS, Mattila M. Cross-sectional tomograms obtained with four panoramic radiographic units in the assessment of implant site measurements. Dentomaxillofac Radiol 2004; 33: 295 – 300. 5. Welander U, Li G, McDavid WD, Tronje G. Transtomography: a new tomographic scanning technique. Dentomaxillofacial Radiol 2004; 33: 188 – 195. 6. Ramfjord SF, Costich ER. Healing after exposure of periosteum on the alveolar process. J Periodontol 1968; 39: 199 –207. 7. Wood DL, Hoag PM, Donnenfeld OW, Rosenfeld LD. Alveolar crest reduction following full and partial thickness flaps. J Periodontol 1972; 43: 141 – 144. 8. Campelo LD, Camara JR. Flapless implant surgery: a 10-year clinical retrospective analysis. Int J Oral Maxillofac Implants 2002; 17: 271 –276. 9. Kan JY, Rungcharassaeng K, Ojano M, Goodacre CJ. Flapless anterior implant surgery: a surgical and prosthodontic rationale. Pract Periodont Aesthet Dent 2000; 12: 467– 474. 10. Hahn J. Single-stage, immediate loading, and flapless surgery. J Oral Implantol 2000; 26: 193 –198. 11. Serhal CB, Van Steenberghe D, Quirynen M, Jacobs R. Localisation of the mandibular canal using conventional spiral tomography: a human cadaver study. Clin Oral Implants Res 2001; 12: 230 – 236. Dentomaxillofacial Radiology 12. Kobayaschi K, Shimoda S, Nakagawa Y, Yamamoto A. Accuracy in measurement of distance using limited cone-beam computerized tomography. Int J Oral Maxillofac Implants 2004; 19: 228 –231. 13. Lecomber AR, Yoneyama Y, Lovelock DJ, Hosoi T, Adams AM. Comparison of patient dose from imaging protocols for dental implant planning using conventional radiography and computed tomography. Dentomaxillofac Radiol 2001; 30: 255 –259. 14. Dula K, Mini R, Van Der Stelt PF, Sanderink CC, Schneeberger P, Buser D. Comparative dose measurements by spiral tomography for pre implant diagnostic: the Scanora machine versus the Cranex Tome radiography unit. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2001; 91: 735 –742. 15. Ekestubbe A, Thilander-Klang A, Lith A, Gröndahl HG. Effective and organ doses from scanography and zonography: a comparison with periapical radiography. Dentomaxillofac Radiol 2004; 33: 87 –92. 16. Fortin T, Champleboux G, Lormée J, Coudert JL. Precise dental implant placement in bone using surgical guides in conjunction with medical imaging techniques. J Oral Implantol 2000; 26: 300 – 303. 17. Fortin T, Isidori M, Blanchet E, Perriat M, Bouchet H, Coudert JL. An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: a clinical report on immediate loading. Clin Implant Dent Relat Res 2004; 6: 111 – 119. 18. Casap N, Wexler A, Persky N, Schneider A, Lustmann J. Navigation surgery for dental implants: assessment of accuracy of the image guided implantology system. J Oral Maxillofac Surg 2004; 62: 116 – 119. 19. Casap N, Tarazi E, Wexler A, Sonnenfeld U, Lustmann J. Intraoperative computerized navigation for flapless implant surgery and immediate loading in the edentulous mandible. Int J Oral Maxillofacial Implants 2005; 20: 92 –98.