* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 2 outputs, voltage and current
Electrical ballast wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrical substation wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Integrating ADC wikipedia , lookup
History of electric power transmission wikipedia , lookup
Schmitt trigger wikipedia , lookup
Surge protector wikipedia , lookup
Current source wikipedia , lookup
Stray voltage wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Voltage optimisation wikipedia , lookup
Voltage regulator wikipedia , lookup
Distribution management system wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Buck converter wikipedia , lookup
Analog output modules 2 outputs, voltage and current 2 Bosch Rexroth AG | Electric Drives and Controls Analog output modules 2 outputs, voltage and current Documentation •Inline analog output module •2 outputs: 0 to 20 mA, 4 to 20 mA, ±20 mA; 0 to 10 V, ±10 V •2-wire connection technique •Complete with accessories (connection plug and labeling field) Technical data R-IB IL AO 2/UI-PAC Local bus interface Designation Connection type Local bus Inline data jumper Supply for module electronics Current consumption of UANA Current consumption of UL Error message to the higher level systems Typ. 24 mA, max. 30 mA Typ. 55 mA, max. 65 mA Failure or undershooting of the logic voltage UL Analog Outputs Connection technology of the actuators Number Connection type Load / output load current output 2-wire connection 2 Spring-cage connection £ 450 W (current); ³ 1 kW (voltage) Output voltage range -10 to +10 V, 0 to +10 V Output current range 0 ... 20 mA, 4 ... 20 mA, -20 ... 20 mA Characteristics Measurement resolution 12 Bit Process data update including conversion time of D / A converter Ambient conditions < 1 ms Permissible temperature (operation) Permissible relative humidity (operation) Protection category -25 ... +55 °C 5 to 90%, no dewing IP20 Dimensions R-IB IL AO 2/UI-PAC Dimensions Electric Drives and Controls, PDF Version, Last Updated 2017-01-10, © Bosch Rexroth AG, Subject to Change Electric Drives and Controls | Bosch Rexroth AG Analog output modules 2 outputs, voltage and current Height H [mm] 141 Width B [mm] 12.2 Depth T [mm] 71.5 Order details Type code Material number: R-IB IL AO 2/UI-PAC R911173634 Electric Drives and Controls, PDF Version, Last Updated 2017-01-10, © Bosch Rexroth AG, Subject to Change 3 Bosch Rexroth AG Postfach 13 57 97803 Lohr, Germany Bgm.-Dr.-Nebel-Str. 2 97816 Lohr, Germany Tel. +49 9352 18-0 Fax +49 9352 18-8400 www.boschrexroth.com/electrics Local contact information can be found at: www.boschrexroth.com/adressen © Bosch Rexroth AG 2012 Subject to modification. Printed in Germany The data specified above only serve to describe the product. As our products are constantly being further developed, no statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.