Download Mammography - X

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Electrification wikipedia , lookup

Utility frequency wikipedia , lookup

Ohm's law wikipedia , lookup

Power engineering wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Electrical ballast wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Current source wikipedia , lookup

Thermal runaway wikipedia , lookup

Electrical substation wikipedia , lookup

Three-phase electric power wikipedia , lookup

History of electric power transmission wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Triode wikipedia , lookup

Distribution management system wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power inverter wikipedia , lookup

Power MOSFET wikipedia , lookup

Rectifier wikipedia , lookup

Schmitt trigger wikipedia , lookup

Stray voltage wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Islanding wikipedia , lookup

Surge protector wikipedia , lookup

Power electronics wikipedia , lookup

Buck converter wikipedia , lookup

Voltage regulator wikipedia , lookup

Opto-isolator wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Mammography
X-ray Generator
Product Highlights
•
Complete range of X-ray Mammography Generators with 4kW/8kW
•
Designed for standard and digital mammography
•
HF 40 kHz X-ray Generator – improved efficiency
•
Simple, stable and solid construction means low maintenance costs over lifetime
•
All existing types of X-ray Mammography Tubes can be connected
Technical Features
•
Modern High Frequency, High Voltage X-ray Generator in oil-bath
•
Can be fitted with several different High Standard Mammo voltage jack connectors
•
External structure in Aluminium for better thermal dissipation even in case of heaviest Applications
•
High Voltage Detection Circuit with kV+ and mA feedback reading circuitries
•
Internal Thermal safety set at 57° Celsius, with rubber “lung” for the compensation of the oil volume
thermal variations
Technical Data
Max. High Voltage Range
20 to 40 kV
Max. mA Range in radiography
Max Generator’s Power
100 to 200 mA
4 / 8 kW
Output Voltage Frequency Ripple
40 kHz
Power Supply
4 or 8 kW Inverter
Option
•
Input and output command with CAN interface
All rights are reserved. Reproduction in whole or parts is prohibited without
the prior written consent of copyright holder.
X-Alliance reserves the right to make changes in specification and/or to
discontinue any product at any time without notice or obligation and will not be
liable for any consequences resulting from the use of this publication.
Printed in Germany
October 2009
4535-888-00101
Distributed by:
X-Alliance GmbH
Suhrenkamp 59-69
22335 Hamburg - Germany
Tel: +49 40 600 88 44 0
Fax: +49 40 600 88 44 44
www.x-alliance.com