Download UC16RL4 Raise-Lower Module - Energi

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Buck converter wikipedia , lookup

Stepper motor wikipedia , lookup

Control theory wikipedia , lookup

Flip-flop (electronics) wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Metadyne wikipedia , lookup

Power over Ethernet wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Electrical connector wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Relay wikipedia , lookup

Opto-isolator wikipedia , lookup

Protective relay wikipedia , lookup

Transcript
Unitron
Accessories
UC16RL4
UC16RL4 Raise-Lower Module
DESCRIPTION
DIN rail
The UC16RL4 is an external relay pack with 4 pairs of relays, which can be used in
Raise/Lower or Binary mode. A quick connector is included for ease of connection
with a UC controller.
MECHANICAL
Size
120 x 130 x 45 mm
Enclosure
Injection moulded ABS.
Note: 4 pads on the controller label allow information about each of the relay
pairs to be recorded. Accepts biro or felt tip pen.
Mounting
Weight
DIN rail.
430g (15.17 oz)
(4.72 x 5.12 x 1.78”)
Injection
Moulded
ABS
enclosure
120mm
ENVIRONMENTAL
Ambient Temperature
Note: This equipment is intended for field installation within another enclosure.
0° - 50°C (32°-122°F) ambient.
Ambient Humidity
0% - 90% RH non-condensing.
EMC Immunity
EN 50082-1
EMC Emmission
EN 55011 class B
130mm
45mm
WIRING
Termination
PCB mounted screw in terminals.
10 way DIL Quick Connector
Conductor Area
Max: AWG 12 (3.09 mm2)
Min: AWG 22 (0.355 mm2)
Note: Use Copper or Copper Clad Aluminium conductors only.
It is recommended that ferrules should be used with all screw terminals.
ELECTRICAL
Supply Requirements
24 V AC +/- 20% 50/60 Hz
Power Rating
8 VA
Indicator
Red light is on when power is supplied
INPUTS/OUTPUTS
Note: Screened cable is recommended for all input connections.
4 Inputs
Current: 10mA @ 10 V DC each input
Voltage: 0 to 10 V DC input only
Return: The Return wire is common to all inputs and is connected internally to the CMN terminal
Quick Connector: A quick connect to a UCxxPG-R controller is possible through the use of a 10 way ribbon cable
(Part No. CC12/CAB Nominal Length 457 mm.)
8 Relay Contacts
Inductive Load: 5A @ 250V AC
or 5A @ 30V DC
Resistive Load: 10A @250V AC
or 10A @ 30V DC
CONFIGURATION OPTIONS
There are two modes of operation: Raise/Lower and Binary conversion (see Modes panels on page 2).
Four links under the terminal cover allow mode selection for each pair of relays.
Any combination of Raise/Lower or Binary Mode outputs possible, e.g. 1 R/L and 3 Binary Mode outputs.
Each RL/4 input allows two relays to be controlled by one UC controller output
Cylon Controls Limited
Clonshaugh Industrial Estate
Clonshaugh
Dublin 17
Ireland
Tel: +353 (0) 1 2450 500
Fax: +353 (0) 1 2450 501
Email: [email protected]
Cylon Controls UK Limited
50 Centenary Business Centre,
Hammond Close,
Attleborough Fields,
Nuneaton,
Warwickshire CV11 6RY
Tel: +44 2476 327777
Fax: +44 2476 327878
Email: [email protected]
Due to Cylon's policy of continuous improvements these specifications may be upgraded without notice.
UCDS-0016 rev 4.04
 Cylon Controls Limited
1
Unitron
Accessories
"Power On"
LED
Inputs 1 - 4
Mode Selection jumpers
BINn
+ 4 -
LK1
LK2
LK3
BIN4
R/L4
R/Ln
BIN3
R/L3
BINn
BIN2
R/L2
R/Ln
BIN1
R/L1
+ 3 -
+ 2 -
+ 1 -
PWR
J2
Link 4
Link 3
Link 2
Link 1
RET 3
INPUT 4
RET 4
INPUT 3
RET 2
INPUT 2
INPUT 1
RET 1
CMN
24V AC
IMPORTANT
Earth this controller by
connecting the CMN wire
(Go), on the secondary side
of the 24V AC transformer,
to Earth at one point.
LK4
Power input (24v AC)
UC16RL4
10 Way Quick Connector
The Quick Connector has 2 "RET"
pins and inputs 1 - 8.
-
-
+
01
When the Quick Connector cable is
used it will connect the
UC controller outputs 1-4
to
UC16RL4 outputs 1-4.
In this case it is also possible to use
UC controller outputs 1-4
as 0 - 10 V analog outputs to other
devices if the relays corresponding to
each analog output are left unused.
-
+
-
+
02
03
01
03
02
04
Relay Pair set for
Binary conversion.
Legend
Pins covered
by jumper
Pins open
LED Indicators
+
04
unitron
Relay Pair set for
Raise-Lower interlock.
Each relay pair is represented by a
pair of LEDs, one yellow (marked
"-") and one green (marked "+").
When an LED is on, the
corresponding relay contact is
closed.
UC16RL4
Yellow (-) LED
Green (+) LED
NC NO
R/L1
01
Output Labels
R/L2
02
R/L3
03
04
05
NC NO COM NC NO COM NC NO COM NC NO COM
COM Common
NO Normally Open
NC Normally Closed
R/L4
06
07
NC NO COM NC NO COM NC NO COM NC NO COM
Outputs 1 - 8
Input
(24 V ac
supply)
Relay Relay
A
B
Green
LED
Yellow
LED
(+)
(-)
BINn
Mode selection
jumper set to "R/L":
R/Ln
Binary Conversion Mode
BINn
R/Ln
Raise/Lower interlock Mode
Red LED
COM
State of Relay Contacts when Relay
is not energised (LED is off).
08
Mode selection
jumper set to "BIN":
Contact Status
Red LED
(24 V ac
supply)
Input
unitron
Relay Relay
A
B
Green
LED
Yellow
LED
(+)
(-)
Off
Don't Care
Off
Off
Off
Off
Lower motor powered
Off
Don't Care
Off
Off
Off
Off
On
0V
Off
Off
Off
On
Lower motor powered
On
0V
Off
Off
Off
Off
On
4 V or 5 V
On
Off
Off
Off
No power to either motor
On
4V
On
Off
Off
Off
On
7 V or 10 V
On
On
On
Off
Raise motor powered
On
7V
On
On
On
On
On
10 V
Off
On
On
On
In Raise/Lower Mode, the interlock
wiring shown will only allow one motor
to be connected to mains at any time,
for all input voltages
R/L1
01
COM NC
NO
03
COM
NC
NO
R/L3
04
COM NC
NO
05
COM
NC
NO
R/L4
06
COM NC
NO
07
COM
NC
NO
08
COM NC
NO
COM
Live
G
NO
Live
NC
R/L2
02
Live or 24 V ac
G0
Lower
motor
-
Raise
motor
+
Neutral or 0 V ac
Raise/Lower valve
UCDS-0016 rev 4.04
 Cylon Controls Limited
2