Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
S6 Statistical Process Control PowerPoint presentation to accompany Heizer and Render Operations Management, 10e Principles of Operations Management, 8e PowerPoint slides by Jeff Heyl © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 1 Statistical Process Control The objective of a process control system is to provide a statistical signal when assignable causes of variation are present © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 2 Statistical Process Control (SPC) Variability is inherent in every process Natural or common causes Special or assignable causes Provides a statistical signal when assignable causes are present Detect and eliminate assignable causes of variation © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 3 Natural Variations Also called common causes Affect virtually all production processes Expected amount of variation Output measures follow a probability distribution For any distribution there is a measure of central tendency and dispersion If the distribution of outputs falls within acceptable limits, the process is said to be “in control” © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 4 Assignable Variations Also called special causes of variation Generally this is some change in the process Variations that can be traced to a specific reason The objective is to discover when assignable causes are present Eliminate the bad causes Incorporate the good causes © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 5 Samples (d) If only natural causes of variation are present, the output of a process forms a distribution that is stable over time and is predictable © 2011 Pearson Education, Inc. publishing as Prentice Hall Frequency To measure the process, we take samples and analyze the sample statistics following these steps Prediction Weight Figure S6.1 S6 - 6 Samples To measure the process, we take samples and analyze the sample statistics following these steps Frequency (e) If assignable causes are present, the process output is not stable over time and is not predicable ? ?? ?? ? ? ? ? ? ? ? ? ? ?? ?? ? Prediction Weight Figure S6.1 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 7 Control Charts Constructed from historical data, the purpose of control charts is to help distinguish between natural variations and variations due to assignable causes © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 8 Process Control Frequency Lower control limit (a) In statistical control and capable of producing within control limits Upper control limit (b) In statistical control but not capable of producing within control limits (c) Out of control Size (weight, length, speed, etc.) © 2011 Pearson Education, Inc. publishing as Prentice Hall Figure S6.2 S6 - 9 Types of Data Variables Characteristics that can take any real value May be in whole or in fractional numbers Continuous random variables © 2011 Pearson Education, Inc. publishing as Prentice Hall Attributes Defect-related characteristics Classify products as either good or bad or count defects Categorical or discrete random variables S6 - 10 Central Limit Theorem Regardless of the distribution of the population, the distribution of sample means drawn from the population will tend to follow a normal curve 1. The mean of the sampling distribution (x) will be the same as the population mean m 2. The standard deviation of the sampling distribution (sx) will equal the population standard deviation (s) divided by the square root of the sample size, n © 2011 Pearson Education, Inc. publishing as Prentice Hall x=m sx = s n S6 - 11 Control Charts for Variables For variables that have continuous dimensions Weight, speed, length, strength, etc. x-charts are to control the central tendency of the process R-charts are to control the dispersion of the process These two charts must be used together © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 12 Setting Chart Limits For x-Charts when we know s Upper control limit (UCL) = x + zsx Lower control limit (LCL) = x - zsx where x = mean of the sample means or a target value set for the process z = number of normal standard deviations sx = standard deviation of the sample means = s/ n s = population standard deviation n = sample size © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 13 Setting Control Limits Hour 1 Sample Weight of Number Oat Flakes 1 17 2 13 3 16 4 18 n=9 5 17 6 16 7 15 8 17 9 16 Mean 16.1 s= 1 © 2011 Pearson Education, Inc. publishing as Prentice Hall Hour 1 2 3 4 5 6 Mean 16.1 16.8 15.5 16.5 16.5 16.4 Hour 7 8 9 10 11 12 Mean 15.2 16.4 16.3 14.8 14.2 17.3 For 99.73% control limits, z = 3 UCLx = x + zsx = 16 + 3(1/3) = 17 ozs LCLx = x - zsx = 16 - 3(1/3) = 15 ozs S6 - 14 Setting Control Limits Control Chart for sample of 9 boxes Variation due to assignable causes Out of control 17 = UCL Variation due to natural causes 16 = Mean 15 = LCL | | | | | | | | | | | | 1 2 3 4 5 6 7 8 9 10 11 12 Sample number © 2011 Pearson Education, Inc. publishing as Prentice Hall Out of control Variation due to assignable causes S6 - 15 Setting Chart Limits For x-Charts when we don’t know s Upper control limit (UCL) = x + A2R Lower control limit (LCL) = x - A2R where R = average range of the samples A2 = control chart factor found in Table S6.1 x = mean of the sample means © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 16 Control Chart Factors Sample Size n Mean Factor A2 Upper Range D4 Lower Range D3 2 3 4 5 6 7 8 9 10 12 1.880 1.023 .729 .577 .483 .419 .373 .337 .308 .266 3.268 2.574 2.282 2.115 2.004 1.924 1.864 1.816 1.777 1.716 0 0 0 0 0 0.076 0.136 0.184 0.223 0.284 Table S6.1 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 17 Setting Control Limits Process average x = 12 ounces Average range R = .25 Sample size n = 5 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 18 Setting Control Limits Process average x = 12 ounces Average range R = .25 Sample size n = 5 UCLx = x + A2R = 12 + (.577)(.25) = 12 + .144 = 12.144 ounces From Table S6.1 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 19 Setting Control Limits Process average x = 12 ounces Average range R = .25 Sample size n = 5 UCLx LCLx = x + A2R = 12 + (.577)(.25) = 12 + .144 = 12.144 ounces UCL = 12.144 = x - A2R = 12 - .144 = 11.857 ounces LCL = 11.857 © 2011 Pearson Education, Inc. publishing as Prentice Hall Mean = 12 S6 - 20 R – Chart Type of variables control chart Shows sample ranges over time Difference between smallest and largest values in sample Monitors process variability Independent from process mean © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 21 Setting Chart Limits For R-Charts Upper control limit (UCLR) = D4R Lower control limit (LCLR) = D3R where R = average range of the samples D3 and D4 = control chart factors from Table S6.1 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 22 Setting Control Limits Average range R = 5.3 pounds Sample size n = 5 From Table S6.1 D4 = 2.115, D3 = 0 UCLR = D4R = (2.115)(5.3) = 11.2 pounds UCL = 11.2 LCLR LCL = 0 = D3R = (0)(5.3) = 0 pounds © 2011 Pearson Education, Inc. publishing as Prentice Hall Mean = 5.3 S6 - 23 Mean and Range Charts (a) (Sampling mean is shifting upward but range is consistent) These sampling distributions result in the charts below UCL (x-chart detects shift in central tendency) x-chart LCL UCL (R-chart does not detect change in mean) R-chart LCL Figure S6.5 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 24 Mean and Range Charts (b) These sampling distributions result in the charts below (Sampling mean is constant but dispersion is increasing) UCL (x-chart does not detect the increase in dispersion) x-chart LCL UCL (R-chart detects increase in dispersion) R-chart LCL Figure S6.5 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 25 Control Charts for Attributes For variables that are categorical Good/bad, yes/no, acceptable/unacceptable Measurement is typically counting defectives Charts may measure Percent defective (p-chart) Number of defects (c-chart) © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 26 Control Limits for p-Charts Population will be a binomial distribution, but applying the Central Limit Theorem allows us to assume a normal distribution for the sample statistics UCLp = p + zsp^ sp = ^ LCLp = p - zsp^ where p z sp^ n = = = = p(1 - p) n mean fraction defective in the sample number of standard deviations standard deviation of the sampling distribution sample size © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 27 p-Chart for Data Entry Sample Number 1 2 3 4 5 6 7 8 9 10 Number of Errors Fraction Defective 6 5 0 1 4 2 5 3 3 2 .06 .05 .00 .01 .04 .02 .05 .03 .03 .02 80 p = (100)(20) = .04 © 2011 Pearson Education, Inc. publishing as Prentice Hall Sample Number Number of Errors 11 6 12 1 13 8 14 7 15 5 16 4 17 11 18 3 19 0 20 4 Total = 80 sp^ = Fraction Defective .06 .01 .08 .07 .05 .04 .11 .03 .00 .04 (.04)(1 - .04) = .02 100 S6 - 28 p-Chart for Data Entry UCLp = p + zsp^ = .04 + 3(.02) = .10 Fraction defective LCLp = p - zsp^ = .04 - 3(.02) = 0 .11 .10 .09 .08 .07 .06 .05 .04 .03 .02 .01 .00 – – – – – – – – – – – – UCLp = 0.10 p = 0.04 | | | | | | | | | | 2 4 6 8 10 12 14 16 18 20 LCLp = 0.00 Sample number © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 29 p-Chart for Data Entry UCLp = p + zsp^ = .04 + 3(.02) = .10 Fraction defective Possible LCLp = p - zsp^ = .04 - 3(.02) = 0 assignable causes present .11 .10 .09 .08 .07 .06 .05 .04 .03 .02 .01 .00 – – – – – – – – – – – – UCLp = 0.10 p = 0.04 | | | | | | | | | | 2 4 6 8 10 12 14 16 18 20 LCLp = 0.00 Sample number © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 30 Patterns in Control Charts Upper control limit Target Lower control limit Normal behavior. Process is “in control.” Figure S6.7 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 31 Patterns in Control Charts Upper control limit Target Lower control limit Figure S6.7 © 2011 Pearson Education, Inc. publishing as Prentice Hall One plot out above (or below). Investigate for cause. Process is “out of control.” S6 - 32 Patterns in Control Charts Upper control limit Target Lower control limit Figure S6.7 © 2011 Pearson Education, Inc. publishing as Prentice Hall Trends in either direction, 5 plots. Investigate for cause of progressive change. S6 - 33 Patterns in Control Charts Upper control limit Target Lower control limit Figure S6.7 © 2011 Pearson Education, Inc. publishing as Prentice Hall Two plots very near lower (or upper) control. Investigate for cause. S6 - 34 Patterns in Control Charts Upper control limit Target Lower control limit Run of 5 above (or below) central line. Investigate for cause. Figure S6.7 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 35 Patterns in Control Charts Upper control limit Target Lower control limit Erratic behavior. Investigate. Figure S6.7 © 2011 Pearson Education, Inc. publishing as Prentice Hall S6 - 36