KL32-1.0-100, KL
KL32SB
32SB--1.0
1.0-1
-100
2-1.0
-1
00, KL
32SB
-1
00
KL3
KL32
1.0-1
-10
KL3
SB--1.0
1.0-1
-10
Description
� KL32-1.0-100, KL32SB-1.0-100 Stationary X-Ray Tube has one focus.
� The integrated high quality tube with glass design has one super imposed focal spot and a
reinforced anode.
� The high anode heat storage capacity ensures a wide range of applications for intra-oral dental
application. A special designed anode enables an elevated heat dissipation rate which leads to a
higher patient throughput and a longer product life. A constant high dose yield during the entire
tube life is ensured by the high density tungsten target. Ease of integration into system products
is facilitated by extensive technical support.
� Kailong product version adheres to international standards, e.g. CE and SFDA.
Features and customer benefits
� Elevated anode heat storage capacity and cooling
� Constant high dose yield
� Excellent lifetime
Print NO.SA0027
2
Release Date: 2012/6/14
2-1.0
-1
00, KL
32SB
-1
00
KL3
KL32
1.0-1
-10
KL3
SB--1.0
1.0-1
-10
Technical Data
Property
Specification
Type
Standard
KL32,KL32SB
Nominal input power(1s DC) of the anode
4800W
IEC 60613/1993
Anode heat storage capacity
31.5kJ
IEC 60613
Maximum cooling capacity of the anode
300W
Target angle (Ref: reference axis) X-ray tube and
X-ray tube assembly
IEC 60788
Tungsten
Anode material
Focal spot nominal value
15°
Ref: Reference axis
X-ray tube nominal voltage
Max. Tube Current
1.0
IEC 60336/1993
100 kV
IEC 60613
60mA DC
IEC 60613
Filament Current
1.9A Max.
Filament Voltage
3.9V Max.
Filament Characteristics
Permanent Filtration
Weight
Operation Limits
Ambient temperature
Relative humidity
Barometric pressure
Print NO.SA0027
Min. 0.8mm Al / 50 kV
IEC60522/1999
285 g
IEC 60613
Transport and Storage Limits
From 10 °C to 40 °C
From 30 % to 75 %
From 700 hPa to 1060hPa
3
Release Date: 2012/6/14
2-1.0
-1
00, KL
32SB
-1
00
KL3
KL32
1.0-1
-10
KL3
SB--1.0
1.0-1
-10
OUTLINE DRAWING
KL32-1.0-100
Print NO.SA0027
4
Release Date: 2012/6/14
2-1.0
-1
00, KL
32SB
-1
00
KL3
KL32
1.0-1
-10
KL3
SB--1.0
1.0-1
-10
KL32SB-1.0-100
Anode Thermal Characteristics
50
35
45
30
35
25
30
20
25
(kJs)
Heat (kHUs)
40
20
15
15
10
10
5
5
0
Cooling
100W
200W
300W
0
0
1
2
3
4
5
6
7
8
9
10
Time (Min.)
Maximum Rating Charts
(Absolute maximum rating charts)
Print NO.SA0027
5
Release Date: 2012/6/14
2-1.0
-1
00, KL
32SB
-1
00
KL3
KL32
1.0-1
-10
KL3
SB--1.0
1.0-1
-10
(DC)
Emission & Filament Characteristics
(AC)
14
4.5
4.3
4.1
3.9
10
Filament Voltage (V)
Tube Current (mA)
12
3.7
3.5
3.3
8
6
4
2
0
1.6
1.7
1.8
Filament Current (A)
Print NO.SA0027
6
40kV
60kV
3.1
2.9
80kV
2.7
2.5
100kV
1.9
Fila.
Release Date: 2012/6/14
2-1.0
-1
00, KL
32SB
-1
00
KL3
KL32
1.0-1
-10
KL3
SB--1.0
1.0-1
-10
Cautions!!!
X-ray tube will emit X–ray when it is energized with high voltage, Special knowledge should be
required and cautions need to be taken when handling it.
1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain and remove the tube.
When mounting tube inserts adopt proper caution, in order to avoid glass bulb breaking and fragments
projection. Please use protective gloves and glasses.
2. Tube insert connected to H.V. supply is a radiation source: be sure to take all necessary safety cautions.
3. Wash thoroughly with alcohol the external surface of tube insert (care of fire risk). Avoid contact of dirty
surfaces with cleaned tube insert.
4. Clamp system inside housing or self-contained units must not mechanically stress the tube.
5. After installation, check the right working of the tube (no fluctuation of tube current nor crackling).
6. Comply with insert thermal parameters, planning and programming the exposure parameters and cooling
pauses. Housing or self-contained units must be provided with an adequate thermic protection.
7. Voltages indicated in charts are valid for transformer supplied with ground center.
8. It is extremely important to observe the connection diagram and the grid resistor value. Any change
could modify the dimensions of the focal spot, also varying diagnostic performances or overloading
anode target.
9. Tube inserts contain environment polluting materials, particularly lead liner tubes. Please apply to
qualified operator for waste disposal, according to local regulation requirements.
10. When any abnormalities are found during operation, immediately switch off the power supply and
contact the service engineer.
Print NO.SA0027
7
Release Date: 2012/6/14
2-1.0
-1
00, KL
32SB
-1
00
KL3
KL32
1.0-1
-10
KL3
SB--1.0
1.0-1
-10
Notes
• This high vacuum product is produced according to state-of-the–art technology. To prevent implosion
please handle with care and use protective devices, e.g. glasses!
• In the interest of complying with legal requirements concerning the environmental compatibility of our
products (protection of natural resources, avoidance of waste) we endeavor to reuse components and to
return them to the production cycle. We guarantee the functioning, quality and life of these components
by taking extensive quality assurance measures, just as for factory-new components.
The described product (s) is/are not commercially
available. Content serves as preliminary information.
The Kailong Medical Instrument Co Ltd., is ISO 9001
certified, manufactures in accordance with the Quality
System Regulations (QSR) as defined by the Food and
Drug Administration (FDA) and endeavors to comply with
legal requirements concerning the environmental
compatibility of its products.
The reproduction, transmission or use of this document
or its contents is not permitted without express written
consent. Offenders will be liable for damages. Kailong
reserves the right to modify the design and specifications
contained herein without prior notice. All rights reserved,
particularly in connection with patent applications or
registrations of utility model or design.
© Kailong Medical Instrument Co Ltd.,
For further information, please contact:
Kailong Medical Instrument Co Ltd.,
Addres:6, No. 6 Road, Dongzhou Industrial Zone,
Fuyang, Hangzhou, China 311401
Fax: +86571 87195003
http://www.kailongx-ray.com
Print NO.SA0027
8
Release Date: 2012/6/14