* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Logic gates applications
Operational amplifier wikipedia , lookup
Digital electronics wikipedia , lookup
Power MOSFET wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Schmitt trigger wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Transistor–transistor logic wikipedia , lookup
Crossbar switch wikipedia , lookup
Applications of the NAND gate (a) Burglar alarm When the switch is closed one input of the NAND gate is LOW. When the LDR is in the light the other input is LOW. This means that if either of these things happen, i.e. the switch is closed or the light is on one of the inputs is LOW, the output is HIGH and the buzzer sounds. Figure 1 (b) Freezer warning buzzer When the thermistor is COLD its resistance is LARGE and the input to the NAND gate is high. Since the NAND gate is connected as an INVERTER the output is LOW. As the thermistor warms up its resistance decreases, the voltage across it falls and the input to the NAND gate falls. When it becomes low enough the output becomes HIGH and the buzzer sounds. Figure 2 How would you adjust the temperature at which the buzzer came on? Further circuits using logic gates The following four circuits demonstrate some further practical applications of logic gates, the function of each circuit being explained. A push-button lock To open the lock the solenoid must be activated and this can be done by pressing both switches A and B. If B is pressed before A, however, the buzzer will sound. +5V A B LOCK 0 1 A light-activated burglar alarm When the switch is in position A the buzzer stays off whatever the illumination of the light-dependent resistor. If the switch is closed in position B the buzzer will come on, however, and stay on when a brief flash of light (perhaps from the torch of a burglar) falls on the light-dependent resistor. The buzzer may only be turned off by returning the switch to position A. +5V A R B 0 A safety thermostat The two contacts X and Y are near the top of the hot water tank and are normally covered with water so that there is a contact between them. The thermistor is also in the water. If the water is too cold and if the contacts are also covered the heater comes on. The temperature at which this occurs may be set by the variable resistor R. +5V X contacts R Y 0 An automatic watering system This is designed to water plants only if the contacts, which may be buried in the soil, are too dry and it is night-time. The relay closes and starts the pump only if both these conditions are fulfilled. (Presumably somebody waters the plants in the daytime because if the switch is pressed the water pump works regardless.) +5V R M pump 0 2