Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Cadence Schematic Capture and Simulation Before using Cadence for the first time, we need to create directories in which Cadence will store the design we create. While you can store the designs in any location. To create this directory execute the following commands: cd mkdir cadence mkdir cadence/mylibs Execute the command icfb& to start Cadence. You should be presented with the Command Interpreter Window (CIW) and Library Manager windows as shown below: Note: When you exit the Cadence design environment not all processes started by the application will be stopped. Unless you ensure that you kill all cadence processes when you exit, hercules will become slower and less responsive. When you are finished using Cadence or if Cadence crashes on you, please make sure to kill your processes. To kill all Cadence processes, run the following command: ps -ef | grep $logname | grep cadence | awk '{print $2}' | xargs kill -9 Figure 1 Command Interpreter Window Library Creation It is strongly recommended that you create a library for each tutorial or lab assignment using a descriptive library name. The create a library for the tutorial, use the following procedure as shown below: • • • • • Using the Library Manager Window, select File => New => Library. Enter the library name mylib in the Name field. Enter the path ~/cadence/mylibs in the Path field. Select the appropriate tech library under Technology Library. Click OK. Edward Gatt 2008© 1 Figure 2 Create Library Window Creating a New Design During the curse of each lab assignments, you will have to create several designs, including schematics, layouts and test circuits. For each of these items, you can create the designs using the following procedure as shown below: • • • • • Using the Library Manager Window, select File => New => Cell View. Select mylib_rlc from the Library Name drop-down menu. Enter the cell name rlc in the Cell Name field. Enter the view name schematic in the View Name field. Select Composer-Schematic from the Tool drop-down menu. Edward Gatt 2008© 2 Figure 3 Create Schematic Window Schematic Capture You should be presented with a empty Composer window as shown: Figure 4 Schematic Window Edward Gatt 2008© 3 Cadence provides many different ways for adding components to your schematic and/or changes options. While designing a circuit, you can use the menus, toolbar (icons on the left side of the screen), or keystroke to accomplish the same task. If you use the toolbar, as you move the mouse over each toolbar icon, a popup description will indicate the functionality. To demonstrate how to create a schematic design, we will be designing the circuit shown here. Figure 5 Schematic Example Adding Component Instances • • • • • Click on the Instance icon or select Add => Instance. You will be presented with two windows, the Component Browser and the Add Instance windows. From the Component Browser Window, under Library, select analogLib. Click on the Flatten checkbox, to provide the full list of components available in this library. Select the component res from the list. By selecting the resistor component, the corresponding information will be filled in the Add Instance window. Edward Gatt 2008© 4 Figure 6 Select Component Window The Add Instance window will also allow us to customize the component we are adding to our schematic. In this case, we would like to adjust the value of the resistor we are adding to 22 K Ohms. As shown below, we simply enter the desired value into the Resistance field. Figure 7 Changing Instance Properties Edward Gatt 2008© 5 • • • • • • Within the schematic editing window, as you move the mouse you should see the outline of a resistor. Place two resistor within your schematic as shown in the completed schematic shown above. Using the same procedure, add a 47n F capacitor, cap, as shown in the completed schematic. Using the same procedure, add a 500m H inductor, ind, as shown in the completed schematic. Using the same procedure, add a ground, gnd, as shown in the completed schematic. When completed, to exit the Add Instance mode, close the Add Instance window and within the schematic editing window hit Escape. Similarly, when editing a schematic or layout, to deselect a given tool, you can simply hit the Escape key. In order to rotate a component instance, you can either select the component by clicking and press r or you select the component and select Edit => Rotate. Adding IO Pins We now need to add IO pins to your design using the following procedure. • • • • • Click on the Pin icon or select Add => Pin. You will be presented with the Add Pin dialog as shown here. Under the Pin Names field, enter Vin Vout. We will initially select the Direction as Input. Within the schematic window, place the first pin, Vin as shown in the completed schematic. After placing the first pin, you should notice that the Pin Names field in the Add Pin window now only contains, Vout. We now need to change the pin Direction to Output and place the Vout as shown in the completed schematic. Figure 8 Create Pins Window Edward Gatt 2008© 6 Connection Wires Now that all of our components and IO pins have been added we need to connect the components together with wire. To connect components within wire, use the following procedure. • • Click on the Wire icon or select Add => Wire (narrow). You will be presented with the Add Wire dialog as shown here. Within the schematic editing window, draw wires by selecting a starting point and dragging the mouse to the desired endpoint. You can create wires to connect components together, to connect two existing wires together, and connecting a component to existing wire. Figure 9 Add Wire Window Modifying Instance Properties We often will need to change the properties of a component we have added to a design. While we could simply delete the component and add the correct component, we can also modify the properties directly. • • • • You currently should have two 22K Ohm resistors in your design. However, looking at the completed schematic, the vertical resistor on the right should be 75 Ohms instead. Select the resistor by clicking on it once. Click on the Properties icon, select Edit => Properties => Object, or press the q key. You will be presented with the Edit Object Properties window as shown here. Modify the Resistance to 75 Ohms and click on OK. Edward Gatt 2008© 7 Figure 10 Instance Properties Window Saving your Designs While you can simply save your design by click on the Save icon or selecting Design => Save, there is a better way to save you designs use the Check and Save. • • • • • Select Design => Check and Save. This option will check you design for any errors or warnings that may be present. You will notified of errors by a visual indicator within your design as well as the error or warnings information within the CIW window. If you created your schematic properly, you should see the following message in the CIW window shown here. If you have errors, you will see small flashing squares within the schematic editing window. Read the error and warning messages within the CIW windows and the correct the errors/warnings as necessary. Once correct, check and save your design by selecting Design => Check and Save. Quick Usage Reference The following are some keyboard shortcuts for commonly used commands. • • • • • • • Press p to add pins. Press q to after selecting a component to edit properties. Press w to add wires. Press f to fit the schematic to the schematic window. Press l to label a wire. Press Up or Down arrow to scroll your design. Press ESC to terminate any of the operation within the schematic window. Edward Gatt 2008© 8 Printing a Design For all of your labs, you will need to turnin printouts of the designs you created. In order to print your schematic, use the following procedure. • Select Design => Plot => Submit. You will be presented with the Submit Plot window as shown here. Figure 11 Submit Plot Window • Click on Plot Options... in the lower right hand corner of the window. You will be presented with the Plot Options window as shown here. Edward Gatt 2008© 9 Figure 12 Plot Options Window • • • • • • Select the Plotter Type as Postscript. Select the Paper Size as 8x10.5. Select the Send Plot Only to File option and enter the desired schematic name, i.e., rlc_schematic. Click on OK. Back in the Submit Plot window, click the OK button. The printed schematic, in EPS format, should now be located within your cadence directory. Creating a Symbol View You now need to create a Symbol view of your circuit. The symbol view is a black-box view that describes a circuit or component as a box with only inputs and outputs visible. • • To create the symbol view, we will create the Symbol cellview from or schematic cellview. Select Design => Create Cell View => From Cellview... to automatically create the symbol. Edward Gatt 2008© 10 You will be presented with Cellview From Cellview window shown here. Figure 13 Create Cellview from Cellview Window • • • • • • • • • • • • Ensure From View Name is schematic and To View Name is symbol. Click on OK You should be presented with the Symbol Editing Window. The outside red box defines the selection region region when selecting the symbol within a schematic design. The inside green box defines the dimension of the symbol as it would be shown within a schematic design. The cdsTerm("Vout") is a label that displays the pin names or the net names (Vout). The cdsParam(1,2,3) are labels that display parameters of an instance, e.g. 75 Ohm. The cdsName("") is a label that displays the instance or cell name, e.g. rlc1. Expand both the green and red boxes by selecting and drag the box edges. Relocate the input and output pins to the center of the expanded symbol. Relocate the cdsName items to the lower portion of the symbol. You should now add a label to the symbol to describe the symbol. Click on the Label icon or select Add => Label. You will be presented with the Add Symbol Label window shown here. Figure 14 Edward Gatt 2008© 11 • • • • Enter RLC as the Label. Change the Font Height to 0.15. Place the label inside the symbol within the Symbol Editing window. Your final symbol should look similar to the following. Check and save the symbol view. Figure 15 Cellview Window Creating a Test Circuit (Schematic) Yo now need to create a schematic that will be used to test your circuit design. • • • From the Library Manager Window, select File => New => Cell View. Select mylib_rlc from the Library Name drop-down menu. Enter the cell name test_rlc in the Cell Name field as shown here. • First, you must add will add the RLC component you just create. Click on the Instance icon or select Add => Instance. Edward Gatt 2008© 12 • • • • • • • • • Again, you will be presented with two windows, the Component Browser and the Add Instance windows. From the Component Browser Window, under Library, select mylib_rlc. Select the component rlc from the list and place the component within your test schematic. From the analogLib library, add a vsin component. Before adding the component to your design, set the AC Magnitude to 1 V. Set the Offset Voltage to 0 V. Set the Amplitude to 50m V. Set the Frequency to 1M Hz. Add a 1p F capacitor, cap, and Ground, gnd to the test schematic and connect the test schematic as shown here. Figure 16 Cell with Supplies • Select Add => Wire Name.... You will be presented with the following window. Edward Gatt 2008© 13 Figure 17 Add Wire Name • • • • In the Name field enter Vin Vout. Switching back to the Schematic Editing window of your test circuit, add the wire names to the circuit by selecting the wires connected to the input Vin and output Vout of the RLC component. Your final test circuit schematic should look similar to the following. Check and save the test circuit schematic. Initializing the Simulation Environment Using the test schematic you just created, you now will simulate your circuit design using Cadence's Analog Environment. For most of the labs, you will use a similar procedure to simulate the schematic and layout designs you will create. The following provides an overview of the procedure required to simulate a schematic design. • • From the schematic window of your test circuit, select Tools => Analog Environment. You will be presented with the Affirma Analog Environment window as shown here. Edward Gatt 2008© 14 Figure 18 Affirma Analog Circuit Design Environment Window • The design area should indicate which schematic you are simulating, which is most cases should be the schematic view of your test circuit. Simulation Engine There are many different simulation engines. For this course will we be using the SpectreS simulation engine. • • In the analog environment window, select Setup => Simulator/Directory/Host. You should be presented with the window shown here. Figure 19 Choose Simulating Engine Edward Gatt 2008© 15 • • • • Select the Simualator as spectreS Ensure the Project Directory is ~/cadence/simulation. Click on the OK button. If you are prompted to "Save Current State," select Yes and enter the state name as state1. Choosing Analyses In addition to different simulation engines, there are also different types of analyses. The following is a brief breakdown of the different analyses available. • • • • Transient Analysis: This provides the transient output response of the circuit with respect to time. The user specifies the time period and the time variant input waveform while the simulator calculates the output response. AC Analysis: This simulates the AC performance of the circuit as a function of frequency, and is based upon the small-signal frequency response model. DC Operating Point: This analysis simply determines the D.C. operating point of the circuit based on the parameters present on the schematic assuming all capacitors opened and all inductors shorted. It is the default mode and is automatically performed before any other analysis in order to determine the initial state of the circuit. DC Sweep Mode: This generates DC transfer characteristics for the circuit by varying a user specified independent source over a range of values. For this lab we will using three of the available analyses types to simulation the circuit. • • • • • Click on the Choose Analysis icon, or select Analysis => Choose. In the window that appears, select the Analysis as tran. You should now be presented with the following window. In the Stop Time field, enter 3u. In the lower left hand corner, ensure that Enabled is selected. Click on the Apply button. By selecting Apply instead of OK, you can continue to add more analyses without reopening the window. If you were to click OK, instead the Choosing Analyses window will be closed. Edward Gatt 2008© 16 Figure 20 Transient Analysis • • • • • • • • • We now need to add an AC analysis. To do so, first select the Analysis as ac. You should be presented with the following window Set the Sweep Variable to Frequency. Set the Sweep Range to Start-Stop. Set the Start to 0.01k. Set the Stop to 10k. Set the Sweep Type to Logarithmic. Set the Points Per Decade to 20. In the lower left hand corner, ensure that Enabled is selected. Click on the Apply button. Edward Gatt 2008© 17 Figure 21 ac analysis • • • We now need to add a DC sweep analysis. To do so, first select the Analysis as dc. You should be presented with the following window Set the Sweep Variable to Component Parameter. Click on the Select Component button. At this point you should switch to your test schematic window and click on the vsin component you added earlier. Edward Gatt 2008© 18 Figure 22 dc analysis • • You will then be presented with the Select Component Parameter window shown here. Select the component parameter dc and click the OK button. Edward Gatt 2008© 19 Figure 23 Component Parameter Window • • • • • Back in the Choosing Analyses window, set the Sweep Range to Start-Stop. Set the Start to 0. Set the Stop to 100. In the lower left hand corner, ensure that Enabled is selected. As we are finished adding analyses, you can click on the OK button. Edward Gatt 2008© 20 Your Affirma Analog Environment window should look similar to the following. Figure 24 Affirma Window with Simulation List Plotting Simulation Data Before you can simulate the design, we first need to select which signals, inputs, and outputs you want to simulate. While there are several methods that you can use to select the simulation outputs, the most convinient method is described here. • • • Select Outputs => To Be Plotted => Select on Schematic. You should now swich back to your Schematic Editing window of your test circuits and select the wires you previously labeled Vin and Vout. Your Your Affirma Analog Environment window should look similar to the following. Edward Gatt 2008© 21 Figure 25 Affirma Window Including Inputs/Outputs for Simulation Running the Simulation We can now simulate our design and view the simulation output to ensure proper functionality. • • Click on the Run Simulation icon or select Simulation => Run. You will be presented with the Waveform Window as shown here. Edward Gatt 2008© 22 Figure 26 Simulation Waveform Window • • • The waveform window consists of three separate plots for each of the three analyses you selected. you can switch between the different plots by clicking within the plot area. Select the DC Response plot. You should notice the 3 in the upper right corner of the plot is highlighted, indicating which plot is currently selected. Select Axes => to Strip. This will split the waveform for the DC Response into two separate plots for Vin and Vout. Repeat this process for the other two analyses. Double-click on the y-axis label of the Transient Response. The following window will be shown. Edward Gatt 2008© 23 Figure 27 • • • • • Fill in the Label field with Vout and click on OK. Repeat this process for the other plots. Use the Markers (A, B) to measure the output peak-to-peak amplitude of the Transient Response signal. Click on the Crosshair Marker A icon on the left. Click on a negative peak of the output waveform. Repeat for Crosshair Marker B, selecting the negative peak. The information for each marker, along with the delta (difference) between the two will be displayed at the bottom of the plot. We can also delete waveforms from the waveform window. To delete the bottom Vin-Vin plot of the DC Response section, click on the bottom waveform, and press the Del key on your keyboard. At this point, your Waveform Window should look similar to the following. Edward Gatt 2008© 24 Figure 28 Using Crosshair Markers Printing the Simulation Waveform To print the simulation results, use the following procedure. • Select Window => Hardcopy. You will be presented with the Hard Copy window as shown here. Edward Gatt 2008© 25 Figure 29 Plot Window • • • • • • Select the Display Type as psb. Select the Plotter Type as Postscript. Select the Paper Size as 8x10.5. Select the Send Plot Only to File option and enter the desired schematic name, i.e., rlc_simulation. Click on OK. The printed waveform, in EPS format, should now be located within your cadence directory. Edward Gatt 2008© 26