Temp Valve Aux Air Main Air Aux Fan Main Fan Supply Input Load Fridge Hold Run Aux Lamp Main Lamp Aux Gas Main Gas Reset Inner Temp Presure Lower Raise Cool Heat Light 2 Light 1 Servo 2500 - What is it? Distributed PID Control and I/O file/ 1 Temp Valve Aux Gas Main Gas Aux Lamp Main Lamp Aux Air Main Air Aux Fan Light 2 Light 1 Servo Main Fan Supply Input Load Fridge PLC Hold Run Reset Inner Temp Presure Lower Raise Cool SCADA Heat 2500 - Eurotherm Distributed Control & I/O 2900 PC300 LCM 2700 (in future) Distributed I/O and EUROTHERM PID file/ 2 2500 Features Aux Gas Main Gas Aux Air Main Lamp Aux Lamp Main Fan Main Air Aux Fan Supply Light 2 Load Input Reset Light 1 Fridge Hold Valve Run Presure Lower Raise Cool Inner Temp Heat Temp Servo 4, 8, 16 way bases 2, 4 or 8 loops per base AI2, AI3, AI4, AO2, RLY4, LGC4, DI4, DI8 modules iTools Windows Configurator Hot swap I/O module Expandable Three Year Warranty file/ 3 Control Loops Loop Break Up to 8 loops per base Each loop can be: - Single PID loop - Ratio control - Cascade pair - Overide control With standard analogue output – OR TPO outputs – OR Raise / Lower output for valve positioning. ON_OFF Sing le SP Selector B_PID + Cascade OP_CON v L_PID v + VP v To OP Driver Override PV Selector Feed Forward User Wiring User Variables: Analogue functions: Digital functions: 8 real values 16 e.g. *,/,+,-, sample and hold, and lots more. 16 e.g. OR,AND,XOR,LATCH<,> file/ 4 2500 DIN Rail Controller •Executes 2 loops @ 110mSec, 8 loops @ 220mS • Soft User “Wiring”. • Configuration by “iTools” on a PC Plug-In I/O Modules circuitry - low cost - optional fuses - SW configured Plug-in I/O Controller- * dual analogue input * dual analogue output * quad digital input * quad logic out * quad relay output Aux Lamp Aux Gas Main Gas Aux Air Main Lamp Main Fan Main Air Aux Fan Supply Light 2 Load Input Reset Light 1 Fridge Hold Valve Run Presure Lower Raise Cool Temp Heat Inner Temp - 2 loop control - cascade control - Soft Wiring - ST, Gain sched. etc - I/O Servo • H3048 based (32bit) DIN-rail or wall mount I/O Network Terminals I/O Bases MODBUS Profibus-DP …... One for every wire Plug in terminal Units With or without fuses From 4 up to a maximum of 16 modules file/ 5 2500 DIN Rail Controller The unit is supplied as follows: Aux Lamp Aux Gas Main Gas Main Air Aux Air Main Lamp Main Fan Aux Fan Supply Light 2 Load Input Reset Light 1 Fridge Hold Run Presure Valve Lower Raise Cool Temp Heat Inner Temp Base, 2500B Controller Module, 2500C I/O Modules, 2500M Terminal Strips, 2500T Power Supply, 2500P Servo I/O Modules file/ 6 Power supply An external 24 VDC power supply is required. The voltage range 18 VDC to 28 VDC A system with 4 analog inputs, 4 analog outputs, 4 digital inputs and 4 digital outputs requires 0.5 amps. Eurotherm offers 3 24VDC supplies 2.5 amp (60 watt 5 amp (120 watt) 10 amp (240 watt) The Eurotherm supply has: Will hold up power for 20-37 ms. On power fail Has watchdog relay file/ 7 DIN rail mount 4, 8, or 16 way units Temp Gas Main Gas Aux Lamp Main Lamp Air Main Air Fan Reset Light 2 Light 1 Servo Main Fan Supply Input Load Fridge Hold Run Valve Pressure Lower Raise Cool Inner Temp Terminal units snap in Heat 2500 - Base Modules changeable “live” (except relay) file/ 8 Terminal Unit, 2500T One for each module including IOC Three Analog input terminal units, – TC – DC/ RTD – ma. Fuses available for relay output (July 99) One terminal for every wire file/ 9 The Control Module (IOC) Aux Lamp Aux Gas Main Lamp Main Air Aux Air Main Fan Aux Fan Supply Load Input Reset Fridge Hold Run Presure Valve Lower Raise Cool Temp Currently 4 variants Heat Inner Temp Main Gas Light 1 Light 2 Servo The IOC goes in the left most slot Data acquisition only Data acquisition with Application Blocks 2, 4 or 8 PID loops 2, 4 or 8 PID loops with Application Blocks IOC does all calculations; PID, Application Blocks, communications file/ 10 IOC Status LED’s LED Color ON ALL OFF * Green Normal operation S Yellow Stand-by (future) Self test failed on power up C Yellow Configuration LED Colour Yellow ON IO network or configuration port communicating *S C OFF X LED X Colour Red X Red ON IOC reset or Module missing, faulty or wrong type Flashing Power on self test failed OFF Normal operation 2500 file/ 11 IOC Configuration port Will appear at both Address 255 & the address set by the address switches Addresses between 65 and 254 software settable only with all switches set to zero RJ11 Socket on the IOC RS232 port Max baud rate is 9600 Using this socket outs the IOC in Config. mode * S C X 2500 RJ45 Socket on the Terminal Unit RS 485 Max baud rate is 32,400 Terminator required in the last socket file/ 12 Communications- (Control Module) 2900 or Computer The 2500 system allows communications using either MODBUS or PROFIBUS Terminator The MODBUS addresses are selected by the DIL switch on the termination assembly beneath the IOC P Parity on P Parity off O Odd E Even 8 7 6 5 4 3 2 1 P O 32 16 8 4 2 1 P E Modbus Address Switch position RJ45 Comms Line Terminator ON OFF Address 05, Parity off file/ 13 2500M/AI2 2-channel Analogue input Module Low level range High level range Resolution -100 to +100mV 0-20mA or 0-10Vdc <2uV for low level inputs <0.2mV for high level inputs Better than 0.2OC +/- 1OC or +/- 0.2% of reading Low and high offsets can be applied All common types, RTD, Zirconia probe 330 to 15Kohm Linearity Calibration accuracy User calibration Thermocouple types Potentiometer input Dual T/C 1+ 1- 2+ 2- 3-wire Pt100 4-wire Pt100 H1 H1 H2 H2 Zirconia Dual V or Probe Dual mA mV hi Z input H1 H1 H2 H1 H2 H2 I1 B1 I2 B2 I1 B1 I2 B2 I1 B1 I2 B2 I1 B1 I2 B2 I1 B1 I2 B2 A1 C1 A2 C2 A1 C1 A2 C2 A1 C1 A2 C2 A1 C1 A2 C2 A1 C1 A2 C2 A1 C1 I1 B1 C1 PRT PRT I2 I1 A1 A2 C2 PRT I2 A2 C1 A1 mA B2 C2 PRT Zi V C2 A2 mA C1 A1 C1 A1 C2 A2 V Functional insulation * C2 A2 Zi file/ 14 2500M/AI3 3-Channel high level Analogue Input Modules Input range Resolution Linearity Calibration accuracy User calibration Power Supply Three Channel Milli-amps (mA) Isolated 24v Supply Two wire Tx, Three Channel Milli-amps (mA) Remote powered two wire Tx P1 P2 P3 P1 P2 C1 C2 C3 I1 I2 P3 C1 C2 C3 I3 I1 C1 I1 -20mA to +20mA < 0.5uA <0.003% of range +/- 0.01% of range, 0.05% of reading Low and high offsets can be applied nominal 24Vdc @ 25mA for two wire transmitters I3 C1 P1 mA I2 mA C2 I2 C2 P2 mA Functional insulation * mA C3 I3 mA C3 P3 mA file/ 15 2500M/AO2 2-channel Analogue output Module Range 0-20mA, 0-10VDC (isolated) Resolution 1 part in 10,000 Analogue output functions Selectable using User Wiring Output Load Up to 600 ohms 1+ 11- 1+ 2+ 2- V V 1- 1+ 1- 1+ 2- 2+ R R mA mA file/ 16 2500M/DI4 4-channel Digital Input Module Contact closure inputs Switching voltage: As supply (18 to 30Vdc) Switching current: 10mA (Initial, 1mS 100mA sink for clean switching) (isolated from system, shared common) 24Vdc Logic inputs Off state: -3 to 5Vdc @ <-0.4mA On state: 10.8 to 30Vdc @ 2.5mA (isolated from system, shared common) Digital input functions Selectable using User Wiring 1 2 C C V+ V+ 1 C 4 3 C C 2 24Vdc Logic Inputs C 1 2 C C C V+ V+ C C + - + - 3 C 4 C + - + - Link for voltage mode V+ V+ C C Contact Inputs 4 3 C C C + 18-30Vdc 1 C 2 C 3 C 4 C file/ 17 2500M/DI8 8-channel Digital Input Module Contact closure inputs Open circuit voltage: 24V dc nominal Short circuit current: 10mA Off state: <100ohm input resistance On state: >28Kohm input resistance Logic inputs (current sinking) Off state: -3 to 5Vdc On state: 10.8 to 30Vdc @ <10mA Digital input functions Selectable using iTools 1 3 C1 C2 2 1 C1 4 2 5 7 1 C3 C4 6 3 3 C1 C2 8 2 C2 4 4 5 7 C3 C4 6 8 1 C1 2 3 C2 4 + - + + - + Functional isolation 5 C3 6 7 C4 Contact Inputs 8 5 C3 6 7 C4 8 + - + + - + Logic Inputs file/ 18 2500M/DO4 4-channel Relay output Module Switching current & volts • Max: 2A, 264Vac resistive • Min: 12Vdc/ac, 100mA (Will work with 2500 logic inputs) Digital output functions B1 B2 B3 B4 • Time Proportioning control, • Motorised valve control • Alarms and events (3 n/o, 1 c/o relay) A1 A2 A3 A4 C4 A1 B1 A2 B2 A3 B3 B4 A4 C4 file/ 19 2500M/DO4/LOGIC 2500M/DO4/24V 4-channel mA logic output 4-channel voltage logic output Quad 10mA logic output • As supply (12-30Vdc), 10mA current source (isolated from system, shared common) Quad 24Vdc logic output • Voltage source as supply, 100mA max (isolated from system, shared common) Self-powered • In the pipe-line Digital output functions • PID Time Proportioning, motorised valves. • On/off - for alarms and events. 1 2 3 C C C 4 C V+ V+ C V+ V+ C Both types of Outputs C C + 12-30Vdc C 1 C 2 C 3 C 4 1 2 3 4 file/ 20