* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SP2 Series Wall‑mount Speaker Strobes
Fault tolerance wikipedia , lookup
Sound reinforcement system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Studio monitor wikipedia , lookup
Buck converter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Voltage optimisation wikipedia , lookup
Wassim Michael Haddad wikipedia , lookup
Transmission line loudspeaker wikipedia , lookup
Stray voltage wikipedia , lookup
Resilient control systems wikipedia , lookup
Surge protector wikipedia , lookup
Distribution management system wikipedia , lookup
Loudspeaker wikipedia , lookup
Loudspeaker enclosure wikipedia , lookup
Alternating current wikipedia , lookup
Opto-isolator wikipedia , lookup
Fire Alarm Systems | SP2 Series Wall‑mount Speaker Strobes SP2 Series Wall‑mount Speaker Strobes ▶ High intelligibility ▶ Low profile design ▶ Low current draw ▶ Power taps of ¼, ½, 1 and 2 watts ▶ Compatible with 25 V or 70.7 V distribution amplifiers ▶ Dual voltage in one unit (12 V and 24 V) ▶ Selectable candela settings of 15 cd and 15/75 cd for the 12 V model and 15, 15/75, 30, 75, and 110 cd for the 24 V model ▶ Synchronizable with the MDL Sync•Circuit Module The System Sensor SP2 Series Wall‑mount Speaker Strobes provide the sound quality essential to voice evacuation with a broad frequency range and low harmonic distortion for crystal clear sound performance, making them ideal for hotel, hospital, and commercial applications. The strobes have field‑selectable settings for 15, 15/75, 30, 75, and 110 cd. These speaker strobes have a field‑reversible strobe allowing the speaker to be mounted either on the right or left to avoid potential obstructions. Certifications and Approvals System Sensor holds these Listings and Approvals: Region Certification USA UL CSFM NYC/MEA UUKC: Signaling Appliances and Equipment for the Hearing Impaired (UL1971), UUMW: Speakers and Amplifiers for Fire Protective Signaling Systems (UL1480, UL1711, and UL2043) 7320-1653: 133 127‑02‑E Installation/Configuration Notes Compatible Products The following products are compatible with the SP2 Series Speaker Strobes: Category Product ID Product Description Control Panels Compatible with all 24 V Bosch Control Panels when used in continuous mode. For synchronization, use an SSMDL or SSMDLW Synchronization Module. Modules SSMDL Synchronization module (red) SSMDLW Synchronization module (white) Mounting Considerations These strobes can be mounted on the indicated back boxes for the indicated applications: Conduit Applications four‑inch square • Surface Mounted •* Flush Mounted • *Surface mounting on a four‑inch square back box requires the use of an SSBBS‑SP2 Back Box Skirt. Strobe Cautions Do not exceed: • • The voltage range for the chosen nominal voltage (8 V to 17.5 V for 12 V nominal or 16 V to 33 V for 24 V nominal) 70 strobes and a maximum line impedance of 4 Ω per loop when using a synchronization module www.boschsecurity.com 2 | SP2 Series Wall‑mount Speaker Strobes • The maximum line impedance of the control panel Wiring Note These strobe units are not recommended for use in coded or pulsed signaling circuits. The input terminals accept wires with diameters between 18 AWG (1.2 mm) and 12 AWG (2.3 mm). Parts Included Quant. Component 1 SP2 Speaker Strobe 1 Hardware pack 1 Literature pack Power Requirements Maximum Operating Strobe Current (12 VDC): 15 cd: 127 mA RMS 15/75 cd: 127 mA RMS Maximum Operating Strobe Current (12 VFWR): 15 cd: 112 mA RMS 15/75 cd: 135 mA RMS Maximum Operating Strobe Current (24 VDC): 15 cd: 59 mA RMS 15/75 cd: 69 mA RMS 30 cd: 90 mA RMS 75 cd: 160 mA RMS 110 cd: 209 mA RMS Maximum Operating Strobe Current (24 VFWR): 15 cd: 64 mA RMS 15/75 cd: 74 mA RMS 30 cd: 93 mA RMS 75 cd: 158 mA RMS 110 cd: 208 mA RMS Speaker Voltage (Input): 25.0 VRMS or 70.7 VRMS, selectable Strobe Voltage (Input): 12 VDC or FWR unfiltered or 24 VDC or FWR unfiltered Technical Specifications Trademarks Environmental Considerations Temperature (Operating): +32°F to +120°F (0° to +49°C) Mechanical Properties Candela Selections: 15 cd1, 15/75 cd1, 30 cd2, 75 cd2, or 110 cd2 Dimensions (H x W x D): 4.875 in. x 8.25 in. x 2.25 in. (12.4 cm x 21 cm x 5.7 cm) Material: Molded plastic enclosure incorporating a Xenon flashtube. Sound Level (UL Reverberant Room) at 10 ft (3 m): ¼ W: 75 dBA ½ W: 78 dBA 1 W: 81.2 dBA 2 W: 84 dBA Speaker Frequency: 400 Hz to 4 kHz Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringing the trademark. Sync•Circuit is a trademark of System Sensor in the United States and other countries. System Sensor is a registered trademark or a trademark of Pittway International, Ltd. in the United States and other countries. 1 When set at these settings (15 cd or 15/75 cd) the devices automatically work on both 12 V and 24 V power supplies. The 15/75 cd selection is listed at 15 cd per UL1971 but provides 75 cd on axis. 2 The strobe is not listed for 12 V operating voltages when set to these selections (30 cd, 75 cd, and 110 cd). When using a 12 V control panel, this device yields required light output only in the 15 cd and 15/75 cd settings. Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 [email protected] www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 [email protected] www.boschsecurity.com © Bosch Security Systems Inc. 2010 | Data subject to change without notice T1124663563 | Cur: en-US, V5, 4 Jul 2010 Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 [email protected] www.boschsecurity.com SP2 Series Wall‑mount Speaker Strobes | 3 Ordering Information SP2R1224MC Speaker Strobe (red) Red, 12 VDC or 24 VDC device with dual voltage capability (25 VRMS or 70 VRMS), field‑selectable taps from 1/4 W to 2 W, and field‑selectable strobe intensities of 15 cd, 15/75 cd, 30 cd, 75 cd, and 110 cd SP2R1224MC SP2W1224MC Speaker Strobe (white) White, 12 VDC or 24 VDC device with dual voltage capability (25 VRMS or 70 VRMS), field‑selectable taps from 1/4 W to 2 W, and field‑selectable strobe intensities of 15 cd, 15/75 cd, 30 cd, 75 cd, and 110 cd SP2W1224MC Accessories SSBBS‑SP2W Back Box Skirt (white) Back box must be a standard 4‑inch square by 2‑1/8 in. deep SSBBS-SP2W SSBBS‑SP2R Back Box Skirt (red) Back box must be a standard 4‑inch square by 2‑1/8 in. deep SSBBS-SP2R www.boschsecurity.com 4 | SP2 Series Wall‑mount Speaker Strobes Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 [email protected] www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 [email protected] www.boschsecurity.com © Bosch Security Systems Inc. 2010 | Data subject to change without notice T1124663563 | Cur: en-US, V5, 4 Jul 2010 Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 [email protected] www.boschsecurity.com