* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Datasheet - Pump Centre
Electrical ballast wikipedia , lookup
Power engineering wikipedia , lookup
Electrical substation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electric battery wikipedia , lookup
Current source wikipedia , lookup
Three-phase electric power wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Schmitt trigger wikipedia , lookup
Stray voltage wikipedia , lookup
Power inverter wikipedia , lookup
Uninterruptible power supply wikipedia , lookup
Rechargeable battery wikipedia , lookup
Surge protector wikipedia , lookup
Voltage regulator wikipedia , lookup
Alternating current wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Buck converter wikipedia , lookup
Opto-isolator wikipedia , lookup
WIMES 3.07 Page 20 APPENDIX C - DATA SHEETS UNINTERRUPTIBLE POWER SUPPLIES PROJECT TITLE (P) PROJECT REFERENCE NUMBER (P) PROJECT LOCATION (P) UPS SUPPLIER (P/S) DOCUMENT REFERENCE (P) REVISION (P) DATE (P) REFERENCE DRAWINGS INCLUDED (Y/N) (P) * - indicates Purchaser’s default requirement. 3.0 OPERATING ENVIRONMENT AND SITE DETAILS 1 2 3 Operating Environment (P) Site Location Inland/coastal Rural/urban/industrial UPS Location () Inside (heated) Inside (unheated) Other (specify) EMC Environment () 1st environment – C1 1st environment – C2 2nd environment – C3 Deviations From Normal Conditions (P) Unusual Environmental Conditions (P) 4.0 ELECTRICAL CHARACTERISTICS SUPPLY Service Service AND 4.2 Load Characteristics 1 Type of Load () (P) PLC, SCADA, instrumentation Valve actuator Other (specify) PLC, SCADA, Instrumentation Supply Details (V, Hz, Ph, tolerances) Current (A) Power factor Non Linear Load (Y/N) Crest Factor Valve Actuator Supply Details (V, Hz, Ph, tolerances) Current Details (A) Nominal operating Maximum operating Starting Power Factor Other Load Type(s) (Specify Details) LOAD 4.1 Electrical Supply Characteristics 1 Voltage, Frequency and No. of Phases (P) 1 Voltage and Frequency Variations (+/- %) (P)1 Voltage variation Frequency variation 1 – If the UPS will be supplied from a diesel generator, the relevant voltage and frequency values shall be specified here. ISSUE 4 NOVEMBER 2015 WIMES 3.07 5.0 PERFORMANCE SPECIFICATION 5.1 General 1 Service Life (Years) (P) 5.3 Electrical Characteristics 5.3.1 Input Characteristics 1 a b c d e f g h i Input Characteristics (P/S) Rated input voltage (V) Rated input voltage tolerance (%) Rated input frequency (Hz) Rated input frequency tolerance (%) Number of phases Rated input current (A) Maximum continuous current (A) THD (current) at rated input current (%) Input power factor 5.3.2 Output Characteristics 1 a b c d e f g h i j k l m Output Characteristics (P/S) Rated output voltage (V) Rated output voltage tolerance (%) Rated output frequency (Hz) Rated output frequency tolerance (%) Number of phases Rated output apparent power (VA) Rated output active power (linear load) (W) Rated output active power (non-linear load) (W) Total voltage distortion (linear load) (%) Total voltage distortion (non-linear load) (%) Output fault clearing capability Overload capability Range of load power factor permitted ISSUE 4 Page 21 5.3.3 Batter and Battery Charger Characteristics 1 a b b c d Battery/Battery Charger (P/S) Battery rating (Ah) Cell voltage (V) Cell rating (Ah) Stored energy time at rated load (min) Restored energy time (to 90 % charge) (min) Characteristics 5.4 Noise 1 Noise Levels (dB(A)) (P/S) Maximum (70*) (P) Actual (S) 5.5 Life Cycle Costs 5.5.1 Efficiency 1 Efficiency (P/S) Minimum (90*) (P) Actual (S) 5.5.2 Service Lives and Costs of Components 1 Expected Service Lives of Components (P/S) Life (x 103 hrs) (S) Component (P) Rectifier/charger Battery Inverter 2 Costs of Components (£)/Time Required to Replace Components (mins) (S) Component (specify) Cost Time Rectifier/charger Battery Inverter 5.5.4 Availability 1 Availability (P/S) Minimum (99.99*) (P) Actual (S) NOVEMBER 2015 WIMES 3.07 6.0 DESIGN SPECIFICATION 6.1 General 6.1.1 General 1 4 5 5 6 UPS Model Number (S) IP Rating (IP 21*) (P) Galvanic Isolation (P) Required (Y/N) Degree of Galvanic Isolation Required (P) Page 22 6.4 Battery (contd.) 3 a b Maintenance Bypass Facility Required (Y/N) (P) c 6.1.2 Weights and Lifting Arrangements 1 Weights (kg) (S) Weight of UPS Heaviest maintenance lift 6 6.1.4 O & M Manuals 1 Type Required/Provided () (P/S) Purchaser’s standard Supplier’s standard 6.2 Input Protection 1 Type of Protective Device (S) 1 Rating of Protective Device (A) (S) 6.3 Rectifier/Battery Charger 2 3 Charging Voltage to Vary with Ambient Temperature (Y/N) (P) Charging Voltage to Vary with Charge on Battery (Y/N) (P) 6.4 Battery 2 2 7 Battery Details (S) Cell/Monoblock Characteristics Voltage (V) Nominal capacity (Ah) Cut-off voltage (V) Cell/Monoblock Configuration Serial String Configurations Number of cells Parallel String Configurations Number of serial strings Number of cells per string Battery Characteristics Voltage (V) Nominal Capacity (Ah) Condition Monitoring System (P) Required (Y/N) Monitored Parameters () (P) Battery temperature Float current Float voltage AC/DC resistance On-line discharge characteristics Other (specify) Location () (S) In the UPS enclosure In a separate enclosure In separate racks Other (specify) 6.5 Configuration and Protection of Outgoing Circuits 1 Configuration and Protection of Outgoing Circuits (P/S) 6.6 Communications 1 Type of Communications Provided (P/S) Required/ Battery Design Life at 20oC (Years) (P/S) Battery to comply with BS 6920 (Y/N) (P/S) ISSUE 4 NOVEMBER 2015 WIMES 3.07 Page 23 6.7 Status Indications, Alarms and Telemetry Outputs 1 Status Indications Required/Provided () (P/S) Load on inverter Load on battery Battery charge remaining 1 Alarms Required/Provided () (P/S) Load on bypass Overload Low/high output voltage Inverter fault Battery charger fault Low battery voltage Over temperature 2 Telemetry Outputs () (P/S) Common fault Load on inverter Load on bypass Required/Provided2 2 – Indicate whether telemetry output is via a serial data connection (SDC) or volt free change-over contacts (VFC) ISSUE 4 NOVEMBER 2015 WIMES 3.07 Page 24 APPENDIX D – SUPPLIER’S SUPPLEMENTARY DATA SHEET INFORMATION Clause ISSUE 4 Supplementary Information NOVEMBER 2015