* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Lightplane 1 Recessed (LP1R) Install Instructions
Loudspeaker wikipedia , lookup
Electrification wikipedia , lookup
Audio power wikipedia , lookup
Buck converter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Electrician wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power over Ethernet wikipedia , lookup
Power engineering wikipedia , lookup
Ground (electricity) wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Transmission line loudspeaker wikipedia , lookup
Three-phase electric power wikipedia , lookup
Gender of connectors and fasteners wikipedia , lookup
Single-wire earth return wikipedia , lookup
Overhead line wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Loudspeaker enclosure wikipedia , lookup
Alternating current wikipedia , lookup
Electrical wiring wikipedia , lookup
LIGHTPLANE 1 RECESSED Installation Guide IMPORTANT SAFETY INSTRUCTIONS When installing or using this recessed fixture basic safety precautions should be followed Read ALL INSTRUCTIONS before installing fixture. •This fixture is intended for installation in accordance with the National Electric Code and Local and State Codes and must be installed by a licensed electrical contractor. •DO NOT INSTALL FIXTURE WITHOUT A MINIMUM 1/2 INCH CLEARANCE ALL AROUND THE FIXTURE. ENSURE CLEARANCE AT TOP OF CHANNEL IS 1 INCH. • THIS FIXTURE IS FOR INSTALLATION IN NON NSULATED CEILINGS ONLY. •To prevent electrical shock, turn off electricity at fuse box before installing the fixture. •Turn off power and allow fixture to cool down before adjusting position of lamp gimbals. •Use AWG#14 wire only for supply to the fixture. Electrical Data Fixture uses a listed 120v rated single circuit track. Minimum 15 Amps Black Input White Neutral Ground DO NOT CONNECT BUILDING POWER DIRECTLY TO LED. PERMANENT LED DAMAGE, RISK OF FIRE AND ELECTROCUTION WILL RESULT. SAVE THESE INSTRUCTIONS Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com LIGHTPLANE 1 RECESSED - TRIM (LP1RT) DROP TILE CEILING - Installation Guide NOTICE: For proper installation, have a qualified electrician install this product. Before installation of any luminary onto an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same. CAUTION: EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH. 2” SPACING 9/16” SUSPENDED GRID CEILING (SHOWN) LPLR-1 (22 38”) 8-32 ALLTHREAD/BRACKET LOCATION BUILDING STRUCTURE BUILDING STRUCTURE CEILING BRACKET SUPPORT WIRE CEILING BRACKET T-GRID T-GRID T-GRID SUSPENDED CEILING BRACKET COVER PLATE SUSPENDED CEILING BRACKET 8-32 ALLTHREAD T-GRID T-GRID SCREWS SCREWS 2” 2” 4” 2” LAY IN INSTALLATION BRACKET & SUPPORT WIRE INSTALLATION 4” T-GRID INSTALLATION (WITH SLOTTED COVER) 8-32 ALLTHREAD 2” T-GRID INSTALLATION INSTALLATION EXAMPLES INSTRUCTION: 1. TURN OFF POWER at fuse box before installing fixture. 2. Install REMOTE DRIVER enclosure in an accessible location (distance as indicated by driver specification) from the LED. Provide conduit, Pull String or provide other access to bring CORD from the WIREBODY to the REMOTE DRIVER. Secure REMOTE DRIVER to building structure with hardware as needed. (By Others). 3. If Joining multiple LED segments remove back cover and secure segments together using JOINING BAR set screws. Each segment requires a separate CORD and may require a separate REMOTE DRIVER. 4. T-GRID should be installed to provide a 1in wide SURFACE OPENING for WIREBODY and LENS. Use appropriate support hardware as needed. (See Below) 5. Suitable SUPPORT RODS to building structure or appropriate brackets should be installed before installing fixture. The Suspended Ceiling must be independently supported from the fixture and spaced to fit the fixture width and length before installing the fixture. 6. While protecting finished parts and supporting the fixture, pull CORD(s) to the REMOTE DRIVER(s) and insert CORD through KNOCKOUT in the enclosure and connect to driver output. If connector is provided on the CORD than attach end of CORD to the connector. Secure excess CORD as needed. 7. Connect Building Power to the REMOTE DRIVER using U.L. approved wire connectors: connect the luminary neutral (white) to the supply neutral, connect the luminary line wire (black) to the supply line wire. Fasten ground wire(s) (Green) to ground wire. 8. Install WIREBODY into T-GRID using BRACKETS and secure with support hardware as needed using one of the suitable methods illustrated. 9. Install LENS(s) If needed. 10. Turn On Power Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com LIGHTPLANE 1 RECESSED - TRIM (LP1RT) DRYWALL - Installation Guide NOTICE: For proper installation, have a qualified electrician install this product. Before installation of any luminary onto an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same. CAUTION: EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH. BUILDING POWER SURFACE OPENING REMOTE DRIVER INSTRUCTION: 1. TURN OFF POWER at fuse box before installing fixture. 2. Install REMOTE DRIVER enclosure in an accessible location (distance as indicated by driver specification) from the LED. Provide Conduit, Pull String or provide other access to bring CORD from the WIREBODY to the REMOTE DRIVER. Secure REMOTE DRIVER to building structure with brackets or blocking as needed (By Others). Provide a 1-1/16 in. wide SURFACE OPENING for WIREBODY and appr priate support for SPRING CLIPS as needed. (See Below) CORD WIREBODY LENS 3 2 16 " 3. If Joining multiple LED segments remove back cover and secure segments together using JOINING BAR set screws. Each segment requires a separate CORD and may require a separate REMOTE DRIVER. V4. While protecting finished parts and supporting the fixture, pull CORD(s) to the REMOTE DRI 1-1/16” ER(s) and insert CORD through KNOCKOUT in Ceiling the enclosure and connect to driver output. If Cutout connector is provided on the CORD than attach end of CORD to the connector. Secure excess CORD as needed. 5. Connect Building Power to the REMOTE DRIVER using U.L. approved wire connectors: connect the luminary neutral (white) to the supply neutral, connect the luminary line wire (black) SPRING CLIP to the supply line wire. Fasten ground wire(s) INSTALLATION (Green) to ground wire. 6. Install WIREBODY into SURFACE OPENING using supplied SPRING CLIPS. 7. Install LENS(s) 8. Turn On Power Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com LIGHTPLANE 1 RECESSED - TRIMLESS (LP1RMUD) DRYWALL - Installation Guide NOTICE: For proper installation, have a qualified electrician install this product. Before installation of any luminary onto an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same. CAUTION: EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH. INSTRUCTION: 1. TURN OFF POWER at fuse box before installing fixture. 2. Install REMOTE DRIVER enclosure in an accessible location (distance as indicated by driver specification) from the LED. Provide Conduit, Pull String or provide other access to bring PLENUM CABLE from the EXTRUSION to the REMOTE DRIVER. Secure REMOTE DRIVER to building structure with brackets or blocking as needed (By Others). Provide a 1-7/16 in. wide SURFACE OPENING for WIREBODY and appropriate support for WIREBODY WING mounting. 3. If Joining multiple LED segments remove back cover and secure segments together using JOINING BAR set screws. Each segment requires a separate PLENUM CABLE and may require a separate REMOTE DRIVER. 4. While protecting finished parts and supporting the fixture, pull PLENUM CABLE(s) to the REMOTE DRIVER(s) and insert PLENUM CABLE through KNOCKOUT in the enclosure and connect to driver output. If connector is provided on the PLENUM CABLE then attach end of PLENUM CABLE to the connector. Secure excess PLENUM CABLE as needed. 5. Connect Building Power to the REMOTE DRIVER using U.L. approved wire connectors: connect the luminary neutral (white) to the supply neutral, connect the luminary line wire (black) to the supply line wire. Fasten ground wire(s) (Green) to ground wire. 6. Install WIREBODY into SURFACE OPENING by securing WIREBODY to blocking using MOUNTING HARDWARE by others. SHEETROCK shall then be placed over WIREBODY WING. PLASTER will then be used to fill in remaining gaps around WIREBODY LENS opening. 7. Install LENS(s) 8. Turn On Power Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com LIGHTPLANE 1 RECESSED - WALLWASH TRIM (LP1RWWT) DRYWALL - Installation Guide NOTICE: For proper installation, have a qualified electrician install this product. Before installation of any luminary onto an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same. CAUTION: EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH. BUILDING POWER INSTRUCTION: 1. TURN OFF POWER at fuse box before installing fixture. 2. Install REMOTE DRIVER enclosure in an accessible location (distance as indicated by driver specification) from the LED. REMOTE DRIVER Provide Conduit, Pull String or provide other access to bring CORD from the WIREBODY to the REMOTE DRIVER. Secure REMOTE DRIVER to building structure with brackets or blocking as needed (By Others). Provide a 1-7/8 in. wideoSURFACE OPENING for WIREBODY and appr priate support for SPRING CLIPS as needed. (See Below) WIREBODY SPRING CLIPS TOP COVER ACCESS Cord DRYWALL 3. If Joining multiple LED segments remove back cover and secure segments together using JOINING BAR set screws. Each segment requires a separate CORD and may require a separate REMOTE DRIVER. 4. While protecting finished parts and supporting the fixture, pull CORD(s) to the REMOTE DRI ER(s) and insert CORD through KNOCKOUT in the enclosure and connect to driver output. If connector is provided on the CORD than attach end of CORD to the connector. Secure excess CORD as needed. 5. Connect Building Power to the REMOTE DRIVER using U.L. approved wire connectors: connect the luminary neutral (white) to the supply neutral, connect the luminary line wire (black) to the supply line wire. Fasten ground wire(s) (Green) to ground wire. 6. Install WIREBODY into SURFACE OPENING using supplied SPRING CLIPS. 7. Turn On Power Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com LIGHTPLANE 1 RECESSED - TRIM (LP1RT) DROP TILE CEILING - Installation Guide NOTICE: For proper installation, have a qualified electrician install this product. Before installation of any luminary onto an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same. CAUTION: EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH. MAXIMUM REMOTE DRIVER DISTANCE* Driver 18 Wire Gauge 18 Wire Gauge w/ Remote Emergency LOW,MED,HI DECOR LOW,MED,HI DECOR 0/10V/ 120 ft 18 ft 10 ft 10ft DALI DMX 72 ft Consult Factory 10 ft Consult Factory HILUME/A3 22 ft 15 ft 10 ft 10 ft * aximum distance includes length of power feed cable suspended from remote driver to luminaire. Ex: 72' max length - 3' suspension = 69' available to run from remote driver to building power. Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com