Download Fuse Status Indicator Universal Power Alert

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Immunity-aware programming wikipedia , lookup

Audio power wikipedia , lookup

Electrification wikipedia , lookup

Current source wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power inverter wikipedia , lookup

Electrical ballast wikipedia , lookup

Ohm's law wikipedia , lookup

Electric power system wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Rectifier wikipedia , lookup

Schmitt trigger wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Ground (electricity) wikipedia , lookup

Triode wikipedia , lookup

Metadyne wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Earthing system wikipedia , lookup

Islanding wikipedia , lookup

Electrical substation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power MOSFET wikipedia , lookup

Power engineering wikipedia , lookup

Voltage regulator wikipedia , lookup

Buck converter wikipedia , lookup

Power electronics wikipedia , lookup

Distribution management system wikipedia , lookup

Opto-isolator wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Three-phase electric power wikipedia , lookup

Stray voltage wikipedia , lookup

Fuse (electrical) wikipedia , lookup

Alternating current wikipedia , lookup

Surge protector wikipedia , lookup

Voltage optimisation wikipedia , lookup

AC adapter wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
p421:Layout 7
7/8/09
3:55 PM
Page 1
Model
BFA
Fuse Status Indicator
Indicates Normal or Open Fuse Status
1-45/64
[43.26]
1
[25.4]
4
[101.6]
The BFA Fuse Status Indicator shows normal or open fuse and also reports connection
integrity. With a nominal 3-phase line voltage applied, the BFA Fuse Status Indicator flashes a normal LED green light that gives positive indication of a good fuse and integrity of the
wire connection to each side of the fuse. The indicator flashes a red fault LED when a fuse
is unconnected or open, if there is a lost connection to either side of the fuse, and if mismatched line and load wires are present. When phase loss occurs both fault and normal
LED’s will extinguish. The indicator will continue to indicate the status of the fuse during
a phase loss if a regenerated voltage is produced on the open phase from a rotating motor.
The BFA Fuse Status Indicator mounts externally to a panel and can be mounted vertically or horizontally. It can be used for all UL Fuses Class H, J, K, R, RK. It can be viewed
from a distance and has a universal input of 208-600 VAC.
Model BFA-100
Power Required: 2.5 VA @ 208 VAC
and 5.5 VA @ 480 VAC.
Temperature Ratings: Operate: 32 to
131°F (0 to 55°C), Storage: -40 to
185°F (-40 to 85°C).
Enclosure: 94 V-0 Flame Retardant
Black ABS Plastic, Panel Mount with
1/2” Plastic, Electrical Conduit Adaptor;
Encapsulated for Environmental
Protection.
Electrical Connections: (6) 2’, 18
AWG, 600V, 105°C PVC Stranded Wire
w/Wire Pin. Terminations, Jacketed with
18” Silt Nylon Corrugated Tubing, .556”
OD.
Weight: NET: 3.52 oz (99.8 g)
SHIPPING: 5.12 oz (145.1 g).
Agency Approvals: UL
Universal Power Alert
Process Control
Model
UPA-130
SPECIFICATIONS
Nominal Voltage: 208-600 VAC ±10
%, Phase-to-Phase, 50/60 Hz.
Max Continuous Voltage: 660 VAC,
Phase-to-Phase.
Rev. Connection Protected: Yes.
Detection Threshold: 10-15 VAC
Across Open Fuse.
Maximum Detector Leakage Current:
0.5 mA @ 600 VAC (Approx).
Indicators: Normal- (3) Green LEDs, 2
Flashes/Sec, Fault- (3) Red LEDs, 2
Flashes/Sec.
Maximum Rated Voltage: 750
VAC/1000 VDC (LINE-TO-LINE or
LINE-TO-GND).
Detection Thresholds: 29 VAC 3Phase, 40 VAC SINGLE-phase, 27
VDC (TYP CUTOFF).
Indicates the Presence of Stored Energy in Control Panels
M30 X 1.5 4G6G EXT
HEX NUT
Ø1-25/64
[Ø35.32]
SLEEVE
O-RING SEAL
Ø1-35/64
[Ø39.29]
1-1/4
[31.75]
1-3/16
[30.16]
3-3/64
[77.39]
The Model UPA-130 Power Alert reduces the risk of electrical arc flash by pre-verifying the electrical isolation from the outside of a control panel. The Universal Power Alert
is hardwired to the circuit breaker or main disconnect and has an LED indication whenever voltage is present. It is engineered with redundant circuitry, which allows it to be powered by the same voltage that it indicates. The eight detector UPA-130 visually alerts to the
presence of any dangerous AC or DC (stored energy) potentials occurring between any
combination of the four input lines (L1, L2, L3, GND). The UPA-130 Universal Power Alert
is designed to fit a 30mm knockout.
Model UPA-130
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Operational Range: AC Single or 3-Phase: 40 to 750 VAC 50/60/400 Hz, (LineTo-Line or Line-To-GND [UL approved 50/60 Hz]). DC or Stored Energy: 30 to
1000 VDC, (Line-To-Line or Line-To-GND).
Maximum Rated Voltage: 750 VAC/1000 VDC (Line-To-Line or Line-To-GND).
Detection Thresholds: 29 VAC 3-Phase, 40 VAC SINGLE-Phase, 27 VDC (TYP
CUTOFF).
Power Consumption: 1.2 Watts at 750 VAC.
Temperature Rating: Operate: -4 to 131°F (-20 to 55°C )
Storage: -40 to 185°F (-40 to 85°C ).
Enclosure: Totally Encapsulated for Environment Protection. NEMA 4X (IP66).
Electrical Connections: (4) 6 ft, 18 AWG 1000V, UL-1452.
Weight: 7 oz (198.45 g).
Agency Approvals: UL.
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
421