* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Download instructions to tenderers
Transistor–transistor logic wikipedia , lookup
Radio transmitter design wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Integrating ADC wikipedia , lookup
Operational amplifier wikipedia , lookup
Schmitt trigger wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power MOSFET wikipedia , lookup
Surge protector wikipedia , lookup
Voltage regulator wikipedia , lookup
Current mirror wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Code Description DL SUN-WIND24V HYBRID SOLAR / WIND ENERGY TRAINER – didactic equipment The trainer must be composed of two sub‐systems, one for the generation of electric energy from solar photovoltaic energy through a solar panel and the other for the generation of electric energy from wind energy through a wind turbine. In this trainer, one of the two inverters, acting as master, must synchronize the frequency of the second inverter, acting as slave, to allow creating a connection between the two outputs that operate as a single line with double available power. The Trainer must be composed of the following items. ROLLING SYSTEM WITH PHOTOVOLTAIC MODULE AND CALIBRATED CELL 2 pcs - This mobile system must incorporate a solar module 85W - 12V, a cell to measure solar radiation and a sensor for measuring the temperature of the module. The supporting structure must consist of a cart with wheels on which the panel shall be fixed through a hinge allowing changing the vertical inclination. Components: 1) Calibrated cell 2) Photovoltaic module 3) Output connectors of a photovoltaic module 4) Connector for calibrated cell and for the temperature sensor 5) Junction box of the photovoltaic module 6) Hinges for the panel inclination Solar panel parameters: Maximum Output power 90W ±5% Open circuit voltage 21,50V Short circuit current 5,35A Voltage @ maximum power point 18,40V Current @ maximum power point 4,90A Max-System Voltage 600V Pm Temperature Coefficients –0,12 %/ºC VOC Temperature Coefficients –0,076 V/ºC Cell efficiency 18 Number of cells 32 Cell technology monocrystalline NOCT 47 ±1 °C SOLAR SIMULATOR 2 pcs - This system must be provided to light the photovoltaic panel inside the classroom or in case of cloudy day; it must be composed by 4 lamps to uniformly distribute the light over the PV module. It must be possible to control the intensity by the operator locally by a potentiometer o remotely by a DC signal. The control panel must include the following elements: Page 1 of 9 Code Description Automatic-Off-Manual selector Input for automatic (remote) control Main switch – differential circuit breaker Status and error indicators Intensity regulator, working in manual mode Main socket with protection fuse is on the bottom of the module. Technical features: Maximum Output power 1000W Maximum current 6A Operating Voltage 230VAC 50/60Hz Number of lamps 4 Single lamp power 250W Intensity regulation technology Microprocessor controlled dimmer Control signal range 0÷10VDC AEROGEN - This element of the trainer must be composed by the wind turbine and associated wind sensors, each installed on a standing pole. Additional components for the motorized version of the aerogenerator shall be: Stepper Motor Power supply Three-blade wind turbine providing 24V, 160W power with the following specifications: Weight 6 kg Rotor diameter 1.17 m Start-up Wind Speed 3.1 m/s Kilowatt hours/month 38 kWh/month @ 5.4 m/s avg. wind speed Maximum Wind Speed 177 Km/h Rated Power 160 watts @ 12.5 m/s wind speed Certifications CSA (certificate 1954979), CE Voltage regulation set point (default) 28.2V Regulator Adjustment Range: 27.2 to 34.0V (approximately) Tower loads Shaft Thrust 24Kg @ 160 Km/h wind speed (230 N @ 45 m/s) ANEMOMETER including both wind speed and wind direction sensors. The wind speed sensor must be made up with three cups attached to a rotating system and must produce 1 impulse for each revolution; meaning that the frequency provided shall be directly proportional to the wind speed. Sensor Type -Wind Speed - Wind cups and magnetic switch -Wind Direction - Wind vane with encoder Mechanical features Page 2 of 9 Code Description -Vane and Control Head - UV-resistant - Wind Cups - UV-resistant - Dimensions (length × width × height) - (250 mm × 276 mm × 415 mm) -Weight - 1.332 kg Output Serial digital signal, property protocol STEPPER MOTOR POWER SUPPLY – this item must be a portable unit for the autonomous supply of stepper motors used to power relevant turbines. It must be designed to meet the needs of motor control for the wind turbine present in relevant trainer providing a the motor control ability from a mains voltage. The adjustment of the speed of the motor (corresponding to a suitable configuration of voltage and output frequency of the signals on the phases of the motor) shall be performed manually by the operator or automatically through an external analogue signal. The output voltage must be galvanically isolated from the mains and safety standards shall be implicitly satisfied. The output must be protected against overload and short circuits. On the front panel, the module must include the following elements: Power Switch with Lamp; Control selector: Manual - off – automatic; Analog signal input terminals 0 ÷ 10V; Potentiometer for manual regulation of output power 0÷100%;Reset button: On the rear panel the following elements shall be included: Stepper motor connector; Main socket with fuse; Connector for programming system. The main socket with fuse and the socket for the connection of the motor must be located on the rear of the module. This module must be protected by means of electronic fuse and it shall be able to work with following mains: Nominal Output power 500W Nominal output current 6.2A Operating Voltage 90 ~ 264VAC Frequency range 47~63Hz Input current 115VAC 1.7A 230VAC 0.75A Intensity regulation technology microcontroller Control signal range 0÷10VDC STEPPER MOTOR used to simulate wind condition, if the trainer will be used indoor or in absence of wind: Voltage VDC 2.1 AMPS/PHASE 6.36 Resistance / Phase (Ohms)@25°C 0.33±15% Inductance / Phase (mH) @1KHz 3.0 ± 20% Holding Torque (Nm) [lb-in] 5.94 [52.57] Detent Torque (Nm) [lb-in] 0.21 [1.8585] Step angle (°) ± Step accuracy 1.8 ± 5% (NON-ACCUM) Back-EMF (V) (300 U/min) 23.15 Rotor Inertia (kg-m2) [Ib-in2] 2.7x10-4 [0.923] Weight (KG) [lb] 3.4 [7.5] Temperature rise : max 80°C (motor standstill; for 2 phase energized) Page 3 of 9 Code Description Ambient temperature -10°C ~ 50°C Insulation resistance100 MOhm (under normal temperature and humidity) Insulation class B 130° Dielectric strength 500VAC for 1 min. (between the motor coils and the motor case) Ambient humidity max.85% (no condensation) BATTERY AND AC INVERTER MODULE 2 pcs - module made to generate an island power distribution line, similar to the public local mains. It must include a battery pack for energy store. The battery pack must be accessible by 2 terminals +/- placed on panel, shown by a battery symbol. It must be designated to keep the battery bank charged by the electrical converter of energy sources. Inverter installed in the module shall convert 24VDC to alternating current and must have the following features: System voltage 24 V Continuous power 900 VA Power 30 min. 1100 VA Power 5 sec. 3000 VA Power asymmetric 500 VA Max. efficiency 94 % Own consumption standby / ON 0,7 W /10 W DC input side Battery voltage 21 V … 32 V Reconnection voltage (LVR) 25 V Deep discharge protection (LVD) current driven or by Steca Power Tarom AC output side Output voltage 230 VAC +/- 10 % Output frequency 50 Hz Load detection (standby) adjustable: 2 W ... 50 W Safety Safety class II (double insulated) Electrical protection reverse polarity battery, reverse polarity AC, over voltage, over current, over temperature Operating conditions Ambient temperature –20 °C … +50 °C Fitting and construction Cable cross-section battery / AC 16 mm2 / 1,5 mm2 Degree of protection IP 20 Dimensions (X x Y x Z) 212 x 395 x 130 mm Weight 9 kg Elements on the module: Page 4 of 9 Code Description Control panel: Power switch for Inverter and instruments; Battery connection: terminals Red+ and Black -; Display for DC Input; Display for AC Output; Mains output, for connecting loads; RJ45 socket for paralleling; SLAVE IN and SLAVE OUT sockets for RS485 bus; Mains output, for connecting loads and paralleling. Battery – 2 pcs 12V 100Ah in series connection Inverter Two display must be included in this module providing electrical status information for DC and AC lines, representing the input and output of the inverter. The AC instrument must provide the voltage, current and Power supplied by the inverter to the connected load. The DC instrument must provide the voltage, current and Power consumed by the inverter to provide the requested power at the output. CHARGE REGULATOR MODULE - Electronic module for charge regulation of the battery with the current supplied by the solar panel. It must include LCD display in order to provide information on situations; a graphic display must inform the user about all important system data and shall enables configuration and adjustment of the controller to the specific requirements of the individual system. Numerous clever functions shall allow the user to adjust the controller to the particular features of the system in question. Thanks to the significantly improved state of charge determination, the system shall be optimally controlled and the batteries shall be protected. This controller shall be used for system sizes of up to 2400 Wp at two battery voltage levels (12V, 24V). In the front panel, the module must include the following elements: Multifunction Display; SLAVE IN and SLAVE OUT sockets for RS485 bus; P.V. panel input; Battery connection; Output, for connecting DC loads; RJ45 socket for the parallel switch box; Output relay, programmable function; Output relay, programmable function. Battery Charger characteristics: Microcontroller digital accuracy PWM Charge mode, Multistage charging technology State of charge Load disconnection depending on SOC Temperature compensation Automatic detection of the voltage External temperature sensor for temperature compensation Remote temperature sensor (option) Modify parameters, through three keys: - Battery type selection (Sealed battery, Gel battery, Flooded battery) - Battery AH setting Common positive grounding or negative grounding on one terminal Integrated self test Monthly maintenance charge Integrated energy meter Two configurable multifunctional contacts Page 5 of 9 Code Description The regulator has protection against the following: Overcharge protection Deep discharge protection Reverse polarity protection of module and battery Reverse polarity protection by internal fuse Automatic electronic fuse Short circuit protection of load and module Open circuit protection without battery Reverse current to PV protection at night Over temperature and overload protection Battery overvoltage shutdown Technical features of the charge regulator: System voltage 24 V Own consumption 30 mA Boost time 30 minutes Self-consumption 4mA at night, 10mA at charging Temp. compensation -30mV/12V DC input side Module current 45 A Max. input voltage 60 VDC DC output side Load current 45 A programmable End of charge voltage 28.2 V Boost charge voltage 28.8 V Equalization charge 30 V Reconnection voltage (SOC / LVR) > 50 % / 25 V Deep discharge protection (SOC / LVD) < 30 % / 23.4 V Operating conditions Ambient temperature -10 °C … +60 °C Equipment Set battery type liquid electrolyte; solid electrolyte configurable via menu. PARALLEL SWITCH BOX – it must have one output (230V or 115V, depending on the connected inverters) on which load can be connected. The maximum available power shall depend on the size and the number of inverter. The parallel switch box also must allow communication with charge controllers. This must allow the PV system to be controlled depending on SOC Page 6 of 9 Code Description Description of connections: Master data input, RJ45 Master input, 230 V / 115 V Slave 2 input, 230 V / 115 V Slave 1 data input, RJ45 Consumer output 2, 230 V / 115 V Communication for charge controller, 2 x RJ45 LOAD AT MAINS VOLTAGE MODULE 2 pcs – This module must incorporate a 35W halogen lamp and a 5W LED lamp, working to the mains voltage. Each lamp must incorporate an ON/OFF control independent switch. HIGH POWER LOAD AT 24VDC MODULE 2 pcs - This module must incorporate 2x20W halogen lamp, working at 24V. The module must incorporate an ON/OFF control switch. LOW POWER LOAD AT 24VDC MODULE 2 pcs - This module must incorporate 2x7W LED lamp, working at 24V. The module must incorporate an ON/OFF control switch. VARIABLE RHEOSTAT MODULE - The variable logarithmic rheostat must allow loading the photovoltaic panel in order to detect the characteristic voltage-current curve. Rheostat range 0 ÷ 90 Ω. Maximum current 6A. SOLAR MEASURING INSTRUMENTS MODULE - The module must be made to perform the measurements of a photovoltaic system. It must include a series of instruments; input terminals +/- shall be placed on the left of each instrument and the output terminals must be on the right. It must provide DC, AC and environmental measurements. All instruments must show readings using the automatic decimal point position, starting from 1/1000 up to the maximum value of each measurement. Communication terminals must be located on the right low side of the panel; two RS485 connectors, one male and one female, must be available for the connection with the PC running the acquisition software and/or with other modules in a chain configuration. Instruments must support MODBUS RTU protocol over RS485 interface, used by the software application, available separately, to perform a guided analysis of the electrical characteristics on the modules of the trainer. It must be supplied by the Battery module; it also must have a switch to disconnect the module when not in use, leaving the experiment connections intact. The module must include 4 multifunction displays: No.2 for DC Measurements and displaying data for Voltage, Power and Current: DC voltage ± 65V DC current ± 20A Dc power autoscale No. 1 display for AC measurement: AC voltage 0-512V AC current ±20A Power Meter No. 1 display showing data for: Page 7 of 9 Code Description Solar irradiance meter 0÷1000 W/m2 Thermometer 0÷400°C Module connections and indicators: Connector for the calibrated cell and for the temperature sensor. Power supply connectors of the module. Voltage must be between 10V and 35V. Power switch, for the module ignition. Connectors for DC signals measuring: voltage, current and power. Connectors for AC signals measuring. Communication port , for the SW application interface. Multifunction display WIND MEASURING INSTRUMENTS MODULE The module must be made to perform the measurements of a wind energy system. It must include a series of instruments; input terminals +/- shall be placed on the left of each instrument and the output terminals shall be on the right. It must provide DC, AC and environmental measurements. All instruments must show readings using the automatic decimal point position, starting from 1/1000 up to the maximum value of each measurement. Communication terminals must be located on the right low side of the panel; two RS485 connectors, one male and one female, shall be available for the connection with the PC running the acquisition software and/or with other modules in a chain configuration. Instruments support MODBUS RTU protocol over RS485 interface, used by the software application, available separately, to perform a guided analysis of the electrical characteristics on the modules of the trainer. It must be supplied by the Battery module; it also must have a switch to disconnect the module when not in use, leaving the experiment connections intact. The module must include 4 multifunction displays: No.2 for DC Measurements and displaying data for Voltage, Power and Current: DC voltage ± 65V DC current ± 20A Dc power autoscale No. 1 display for AC measurement: AC voltage 0-512V AC current ±20A Power Meter Wind speed meter 0 ÷ 45 m/s Wind direction meter 0 ÷ 359° Module connections and indicators: Connector for the calibrated cell and for the temperature sensor. Power supply connectors of the module. Page 8 of 9 Code Description Voltage must be between 10V and 35V. Power switch, for the module ignition. Connectors for DC signals measuring: voltage, current and power. Connectors for AC signals measuring. Communication port , for the SW application interface. Multifunction display The trainer must include a three level vertical frame for the fitting of the modules. Complete with a set of connecting cables and with an experiment manual. It must be possible to perform the following exercises: Identification of the components Location of the photovoltaic module Measurement of the solar irradiation Measurement of the voltage of the photovoltaic module with no load Measurement of the short circuit current of the photovoltaic module Current voltage graph of the photovoltaic module Measurement of v and i of the photovoltaic module with overload Regulation and charging of the battery Direct current solar installation Alternating current installation Identification of the components Installing and testing wind turbine Installing and testing anemometer Connecting wind turbine and anemometer to the trainer Activating the braking action Regulating and charging battery Direct current wind installation Alternating current installation: standby function investigation Combined installation low voltage parallel connected, ac separated Combined installation low voltage separated, ac parallel connected Combined installation low voltage and ac parallel connected Page 9 of 9