Download QUICKTRONIC® PROStart® T5HO 347-480V

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Control system wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Flip-flop (electronics) wikipedia , lookup

Islanding wikipedia , lookup

Stray voltage wikipedia , lookup

Electrification wikipedia , lookup

Rectifier wikipedia , lookup

Buck converter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Alternating current wikipedia , lookup

Voltage optimisation wikipedia , lookup

Distribution management system wikipedia , lookup

Automotive lighting wikipedia , lookup

Mains electricity wikipedia , lookup

History of electric power transmission wikipedia , lookup

Schmitt trigger wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Opto-isolator wikipedia , lookup

Rectiverter wikipedia , lookup

LED lamp wikipedia , lookup

Fluorescent lamp wikipedia , lookup

Oil lamp wikipedia , lookup

Safety lamp wikipedia , lookup

Electrical ballast wikipedia , lookup

Transcript
<10% THD Electronic T5HO Fluorescent Programmed Rapid Start Systems
QUICKTRONIC® PROStart® T5HO 347-480V High Ambient Temp.
Normal Light Output
Professional Series
Lamp/Ballast Guide
54W T5 - PENTRON® HO
1 or 2-lamp
QTP2x54T5HO/347-480 PSN HT
Also operates:
FT55DL, FPC55, L58
Two lamp model can be wired
for one lamp operation.
Key System Features
■ 90°C maximum case temp.
■ 347-480V input voltage range
■ Low-profile (1.00" High)
■ 100% Ballast factor
■ QUICKSENSE® ballast
technology (end-of-lamp-life
sensing)
■ PROStart programmed start
■ Occupancy sensor
applications
SYLVANIA 347-480V
QUICKTRONIC HIGH
AMBIENT (HT) PHO operates
PENTRON HO, PENTRON HO
Circline, and DULUX® L T5
lamps with full lumen output and
optimal system performance.
SYSTEM 347-480V PHO HT
allows operation of the ballasts in
industrial applications using a
480V AC system. This eliminates
the need to rewire existing 480V
installations or to drop the voltage
by using expensive and bulky
transformers. The same product
can also be used for 347V applications, allowing for a reduction
in inventory model numbers.
SYSTEM 347-480V PHO HT is
specifically designed for high
ambient temperature applications. The ballast can be operated
at case temperatures of up to
90°C, making it an ideal choice
for high ambient settings such as
industrial high-bay lighting.
SYSTEM 347-480V PHO HT
ballasts contain QUICKSENSE
ballast technology, a patented
circuitry designed to shut down
the system reliably and safely
when lamps reach end-of-life.
Setting the standard for quality,
SYSTEM 347-480V PHO HT is
also covered by our QUICK 60+®
warranty, the first and most
comprehensive system warranty
in the industry.
SYSTEM 347-480V PHO HT is
available in a two lamp model to
cover a wide range of applications. The same ballast can be
wired for 1 or 2 lamp operation.
■ UL type CC rated
■ 0°F Starting
■ Operates at >40 Khz to reduce
potential interference with
infrared control systems
■ High power factor
■ Low harmonic distortion
■ Lightweight
■ UL, CSA, FCC
Application Information
SYLVANIA
QUICKTRONIC PHO
is ideally suited for:
■ Industrial high-bay
■ Commercial
■ Retail
■ Hospitality
■ Institutional
■ New Construction
■ Direct Lighting
■ Indirect Lighting
■ Surface Mount
■ Cove Lighting
46
System Information
SYSTEM 347-480V PHO HT
operates from 347V through
480V, 50 or 60Hz, eliminating
“wrong voltage” wiring errors
and reducing the number of
models in inventory by half.
PROStart ballasts provide
optimum starting conditions
to provide up to 100,000
switching cycles for use on
occupancy sensors and
building control systems.
QUICKSENSE ballast
technology helps to protect
against overheated bases
and sockets, as well as
cracking of the glass wall,
and uses dynamic end-oflamp-life sensing to avoid
false shutdowns caused by
some static sensing methods.
QUICKSENSE ballast
technology will auto reset
when the end-of-life lamps
are replaced with new ones.
System Type
Input
Wattage
Initial
Lumens
System
LPW
F40T12 - E.S. Magnetic Ballast (4-lamp)
F34T12 - E.S. Magnetic Ballast (4-lamp)
172
144
11590
9500
67
66
FO32T8/XP - QT4x32IS (4-lamp)
FP54T5 - QTP2x54T5HO/347-480 PSN HT (2-lamp)
114
121
10800
10000
95
83
The two lamp unit can be
wired for one lamp operation,
allowing for an additional 50%
reduction in inventory model
numbers.
SYSTEM 347-480V PHO HT
comes in a 25.4H or 30H mm
profile, and PENTRON lamps
are designed to provide peak
performance at 35°C fixture
ambient, allowing for smaller
and more innovative fixtures.
PROStart®
T5HO 347-480 HT
<10% THD Electronic T5 HO High Ambient Fluorescent Systems
Input
Voltage
(VAC)
Item
Number Description
Input
Current
(AMPS)
Lamp1
Type
3
3
Performance Guide
Rated
Ballast
Input System
Lumens No. of Factor System3 Power Efficacy
(lm)
Lamps (BF) Lumens (Watts) (lm/W)
49146 QTP 2x54T5HO/347-480 PSN HT 347-480 0.35/0.25 FP54T5HO
(49145)*
1
2
3
Normal Ballast Factor
2,3
5000
2
1
1.00
1.00
10000
5000
121/120
61
83
82
Also compatible with other manufacturer’s equivalent lamp types that meet ANSI standards.
Rated lamp lumens and performance data based on PENTRON® HO lamps.
At 35°C lamp ambient temperature.
*(49145) QTP 2x54T5HO/347-480 PSN HT: same as 49146, with leads.
COMING ATTRACTIONS: New High Ambient Model (90°C case temp) - COMING Q2 2006 - 49166 QTP4x54T5HO/480V PSN HT SCL.
Installation Notes
■ For 480V applications connect two phases (line and
line) to the input
■ For 347V applications connect line and neutral to the
input as shown (DO NOT CONNECT two phases of
347V to the same ballast)
Line
Input
■ Switching: Simultaneously disconnect all
ungrounded line conductors
480V
347V
Line
(Black)
Line
(Black)
Line
(Black)
Neutral
(White)
■ Ground ballast case: Install in accordance with the
National Electric Code
Line Input
Line Input
BALLAST
BALLAST
Red
LAMP
Red
Yellow
LAMP
Blue
1 LAMP
LAMP
2 LAMP
Dimensions:
Model QTP2x54 T5HO/347-480 PSN HT enclosure size:
Overall: 16.73"L x 1.18"W x 1.0"H (425mm L x 30mm W x 25.4mm H)
Mounting: 16.34" (415mm)
Wiring:
Push-in connectors (no leads provided)
Use 18AWG solid copper wire only
Packaging:
Quantity: 20 (no leads), 10 (leaded)
Weight: 2L: 0.88 lbs (0.40kg) each (approx)
Blue
Specifications4
Starting Method: Programmed Start
Ballast Factor: 1.00
Circuit Type: Series
Lamp Frequency: > 40 KHz
Lamp CCF: Less than 1.6
Starting Temp: 0°F minimum5
Input Frequency: 50/60 Hz
Low THD: < 10%
Power Factor: > 98%
Voltage Range: +/–10% of Rated
Input
UL Listed Class P, Type 1, Outdoor,
Type CC
CSA Certified
High Ambient Applications:
90°C Max. Case Temp. (3 yr. warranty)
Standard Ambient Applications:
70°C Max. Case Temp. (5 yr. warranty)
FCC 47CFR Part 18 Non-Consumer
Class A Sound Rating
ANSI C62.41 Cat. A Transient Protection
Dynamic End-of-Lamp-Life Sensing
Remote Mounting up to 18 feet5
4
Data based on PENTRON HO lamp types for
primary ballast application.
5
Operation below 50°F may affect light output
or lamp operation – see “Low Temp. Starting”
definition. Remote red leads up to 18 feet. Keep
blue leads <10 feet.
System Life / Warranty
QUICKTRONIC® products are covered
by our QUICK 60+® warranty, a comprehensive lamp and ballast system
warranty. For additional details, refer
to our QUICK 60+ warranty bulletin.
Item Number
49146 QTP 2 x 54 T5HO/347-480 PSN HT
Starting/Ballast Factor
QUICKTRONIC PROFESSIONAL
Line Voltage (347-480V)
Number of Lamps (2)
Primary Lamp Wattage
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828)
www.sylvania.com
Ordering Guide
Specifications subject to change
without notice.
47