* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Cathode ray oscilloscope
Variable-frequency drive wikipedia , lookup
Three-phase electric power wikipedia , lookup
Stray voltage wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Vacuum tube wikipedia , lookup
Chirp spectrum wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Buck converter wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Cavity magnetron wikipedia , lookup
Mains electricity wikipedia , lookup
Integrating ADC wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Tektronix analog oscilloscopes wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
The cathode ray oscilloscope This versatile instrument was developed by Brown in 1897 from the cathode ray tube. It has many uses, including voltage measurement, observation of wave forms, frequency comparison and time measurement. Figure 1 is a simplified diagram of a cathode ray oscilloscope. cathode (C) Focussing anode (A1) Y plates Electron beam X plates vacuum grid (G) +5 kV Accelerating anode (A2) Fluorescent screen Figure 1 At the centre of the instrument is a highly evacuated cathode ray tube with the following features: (a) a heated cathode C to produce a beam of electrons - a typical beam current is of the order of 0.1 mA; (b) a grid G to control the brightness of the beam; (c) an accelerating anode A2 - a typical potential difference between A2 and the cathode would be about +1000 V; (d) a pair of plates Y1 and Y2 to deflect the beam in the vertical direction; (e) a pair of plates X1 and X2 to deflect the beam in the horizontal direction; (f) a fluorescent screen F on which the beam of electrons falls - in many modern oscilloscopes this is coated with zinc sulphide, which emits a blue glow when electrons collide with it, while there are other coatings that glow for some seconds after the beam has passed so enabling transient events to be seen more clearly; (g) a graphite coating to shield the beam from external electric fields and to provide a return path for the electrons (see below); (h) a mumetal screen which surrounds the tube and shields it from stray magnetic fields. The focusing and accelerating systems are connected at different points along a resistor chain. Focusing is achieved by varying the voltage applied between the two anodes A1 and A2. Since secondary electrons are emitted from the screen when the electron beam hits it, the phosphor coating of the screen and the inner graphite layer of the tube are both earthed to prevent a large build-up of static charge on the tube. In the double beam oscilloscope there are two Y plates with an earthed plate between them to split the beam into two. Two traces are then observed on the screen. This can be most useful when comparing phase differences or making lapsed time measurements. 1 The deflection system The beam may be moved 'manually' in the X- and Y-directions by applying a d.c. or a.c. voltage to the X- and Y-plates. Alternatively it can be moved using the time base system. The time base circuit applies a saw-tooth waveform to the X-plates, as shown in Figure 2. The beam is moved from the lefthand side of the screen to the right during the time that the voltage rises to a maximum, and then is returned rapidly to the left as the voltage returns to zero. This fly-back time should be as short as possible. right right right left left left Figure 2 The rise time is usually between 1 s and 1 s for most oscilloscopes used in schools, but time base speeds of many seconds or of fractions of a microsecond can be obtained on more elaborate instruments. If a voltage is now applied to the Y-inputs, the variation of this voltage with time may be displayed on the screen. Some such variations are shown in Figure 3, together with the effect of various alterations of time base speed or input frequency. Cathode ray oscilloscope traces Figure 3 shows the appearance of the oscilloscope screen when a variety of different signals are applied to the Y-plates. The following diagram shows you various patterns that can be made on the screen with two different inputs d.c. input a.c. input 2 The speed of the time base will change what we see on the screen even if the input signal is kept the same. The following four diagrams show this. d.c. input with the time base off a.c. input with a slow time base d.c. input with the time base on a.c. input with a fast time base Because the deflection of the spot depends on the voltage connected to the Y plates the CR0 can be used as an accurate voltmeter. The oscilloscope is also used in hospitals to look at heartbeat or brain waves, as computer monitors, radar screens and is also the basis of the television receiver. 3 The cathode ray tube screen showing various inputs (a) time base off (the small circles have been added to help you see the spot) no input – spot adjusted left d.c input lower plate positive d.c input upper plate more positive a.c input no input d.c input – upper plate positive d.c input – lower plate positive low frequency a.c input high frequency a.c. input a.c input with a diode no input d.c input upper plate positive (b) time base on 4 large amplitude a.c input small amplitude a.c input a.c. input with a slow time base a.c input large Y gain voice or music a.c. input with a fast time base a.c input small Y gain full wave rectification 5 Measurements with the cathode ray oscilloscope The primary uses of the cathode ray oscilloscope (CR0) are to measure voltage, to measure frequency and to measure phase. (i) Measuring voltage Because of its effectively infinite resistance, the CR0 makes an excellent voltmeter. It has a relatively low sensitivity, but this can be improved by the use of an internal voltage amplifier. The oscilloscope must first be calibrated by connecting a d.c. source of known e.m.f. to the Y-plates and measuring the deflection of the spot on the screen. This should be repeated for a range of values, so that the linearity of the deflection may be checked. The known e.m.f. is then connected and its value found from the deflection produced. Most oscilloscopes have a previously calibrated screen giving the deflection sensitivity in volts per cm or volts per scale division. In this case a calibration by a d.c. source may be considered unnecessary. (ii) Measuring frequency Using the calibrated time base the input signal of unknown frequency may be 'frozen', and its frequency found directly by comparison with the scale divisions. Alternatively the internal time base may be switched off and a signal of known frequency applied to the X-input. If the signal of unknown frequency is applied to the Y-input, Lissajous figures are formed on the screen. Analysis of the peaks on the two axes enables the unknown frequency to be found. (iii) Measuring phase The internal time base is switched off as above and two signals are applied as before. The frequency of the known signal is adjusted until it is the same as that of the unknown signal. An ellipse will then be formed on the screen and the angle of the ellipse will denote the phase difference between the two signals We can see this in Figure 4. y Let be the phase difference between the two signals yo and let the signal applied to the x plates be x = x0sin(t) y1 = yosin and that applied to the y plates be y = yo sin (t+)). But when x = 0, sin(t) = 0, giving t = 0. At this point y = y1 = yo sin , and hence may be found. Examples of the traces for two particular phase differences are shown in Figure 5. y x Figure 4 y y1 = yosin yo yo y1 = yosin x x =0 Figure 5 = 90o = /2 c 6