Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
TETRA Data Applications for Gas and Oil Dubai, September 2013 Funk-Electronic Piciorgros GmbH Michael D. Piciorgros (CEO) Why and not …. P25 DMR WiMAX WiFi GSM, Edge, 2G, 3G, (4G) Other digital Wireless Systems Piciorgros GmbH * Germany … because ? Try to compare all technical and commercial aspects of the following presentation with the optional technologies and the decision will be easy! Piciorgros GmbH * Germany Requirements for Gas and Oil Applications Piciorgros GmbH * Germany Typical Requirements for Gas and Oil Remote measurement of physical values at the Wellheads: Temperature Pressure Flow Rate Alarms Measurement for Cathodic Corrosion Protection (CP): Voltage Current Alarms Siren Alarming at Plants Action in Control Direction (from Control Room) Leak Detection (and other) Alarms Action in Alarm Direction (to Control Room) Piciorgros GmbH * Germany SCADA Requirements Different PLC (RTU) Vendors: Siemens Emerson General Electric Schneider Electric Different Protocols that are used for different Oil Fields: DNP3, Modbus RTU, Modbus ASCII Sinaut, IEC 60870-5-101 Modbus ASCII ROC, BSAP, ... and more Number of PLC (RTU) per Application Can differ from 2-3 up to several hundred per Oil Field Piciorgros GmbH * Germany CP (Cathodic Protection) Requirements Low Polling speed: Polling can be one per hour or even less Direct Access of Voltage and Current from Gas or Oil Pipeline: Low data volume and low data speed application Embedded I/O Requirement from TETRA device Piciorgros GmbH * Germany Additional Requirements: Secured Communication: Authentication Encryption On Shore and Off Shore Applications (Oil Platforms) Parallel use of Voice and Data Wide Temperature operating range Mixed IP and non IP based Data Communication Over The Air (OTA) Software Upgrade Remote Configuration Access to Outstations via WEB Browser Piciorgros GmbH * Germany How many Gas and Oil sites can be polled with TETRA? Typically a complete polling cycle for Gas and Oil Application should not last more than 5 minutes. Assuming that a polling cycle with the Modbus RTU or DNP3 protocol over TETRA with SDS lasts one Second, 60 sites could be polled per one minute and 5 * 60 sites = 300 sites in 5 minutes on one (of the four) TETRA time slots When using a TETRA Data Gateway like the TGW-100, multiple polling nodes can use the same TETRA time slot in parallel without reducing the polling rate. And in case that 4 polling nodes will be used, the total number of sites that can be polled in 5 minutes will be: Number of Polling Cycles in 5 minutes = 300 * 4 = 1200 Remark: The 1200 pollings use only one of the four TETRA time slots. Using all time slots would result in 1200 * 4 = 5000 poll cycles within 5 Minutes! Piciorgros GmbH * Germany TETRA Modem Design Piciorgros GmbH * Germany TETRA Modem for DIN Rail mounting with two serial Ports, one Ethernet Port and an Audio (voice) Port Piciorgros GmbH * Germany TETRA Modem as before with additional embedded analog and digital I/O Piciorgros GmbH * Germany TETRA Data Network Structure Radio-to-Radio Communication Piciorgros GmbH * Germany SCADA using SDS based Radio-to-Radio Communication SCADA Control Room Serial Interface SDS Public Lighting TMO-100 Serial Communication SDS SDS TMO-100 I/O Command and Control Device TMO-100 SDS Serial Interface Tetra Switch TMO-100 Piciorgros GmbH * Germany PLC / RTU TETRA Data Network Structures using a Data Gateway for SDS and Packet Data (IP) Piciorgros GmbH * Germany Highly Redundant TETRA Packet Data and SDS Gateway for SCADA Critical Operation Piciorgros GmbH * Germany Highly Redundant TETRA Packet Data Gateway for SCADA Critical Operation Supported Protocols: MODBUS-RTU IEC60870-5-101 DNP3 ROC BSAP PakBus Siemens SINAUT any customer specific or proprietary protocols Piciorgros GmbH * Germany Redundant TETRA Packet Data Gateway for SCADA Critical Operation Features: COM Port: RS-232 or RS-485/422 AUX Port: RS-232 or RS-485 Ethernet Port: One (TGW-100) or two (TGW-100R) Ethernet interface: RJ-45, 10/100 MBPS Power Supply: Dual Power Supplies – hot swappable Piciorgros GmbH * Germany SCADA – using a TETRA SDS Gateway SCADA Control Room TMO-100 I/O … or Serial Interface SDS Two Serial Interfaces SDS TGW-100 SDS Gateway TMO-100 Command and Control Line Device IP Communication SDS Serial Interface Tetra Switch TMO-100 Piciorgros GmbH * Germany Analog and Digital I/O PLC / RTU Performance Test with SDS-Gateway on ONE SCCH/MCCH: Infrastructure: TETRA with one carrier TETRA Data Link: One SCCH Data Compression: OFF Data nodes: One or more polling nodes, each polling 10 TMO-100 Protocol: Modbus RTU Polling Target: Polling different numbers of bytes from inside the TMO100 SDS: 20 Bytes One Node Two Nodes Three Nodes Four Nodes Eight Nodes 65 130 200 250 295 SDS: 100 Bytes 285 SDS: 200 Bytes 265 Table showing polls per minute Piciorgros GmbH * Germany Performance Test with SDS-Gateway on FOUR SCCH/MCCH: Infrastructure: TETRA with one carrier TETRA Data Link: MCCH plus three SCCH Data Compression: OFF Data nodes: One or more polling nodes, each polling 10 TMO-100 Protocol: Modbus RTU Polling Target: Polling different numbers of bytes from inside the TMO100 SDS: 20 Bytes One Node Two Nodes Three Nodes Four Nodes 16 Nodes (on each TS) (on each TS) (on each TS) (on each TS) (on each TS) 210 410 600 760 880 SDS: 100 Bytes SDS: 200 Bytes Table showing total polls (on all time slots) per minute (values rounded) Piciorgros GmbH * Germany SCADA – using a Packet Data Gateway SCADA Control Room TMO-100 I/O … or Serial Interface PD Two Serial Interfaces PD TGW-100 SDS Gateway TMO-100 Command and Control Line Device, CP Interface IP Communication PD Serial Interface Tetra Switch TMO-100 Piciorgros GmbH * Germany Analog and Digital I/O PLC / RTU SCADA – using direct IP Communication SCADA Control Room IP PD TMO-100 PD Direct IP Communication to TETRA SwMi TMO-100 I/O CP, Command and Control Line Device PD IP Tetra Switch TMO-100 Piciorgros GmbH * Germany AMR, PLC or RTU TMO-100 TETRA Data Modem Feature List Piciorgros GmbH * Germany Embedded Web-Browser Piciorgros GmbH * Germany Embedded IP and TETRA Router Piciorgros GmbH * Germany Embedded mySCAD Micro SCADA Piciorgros GmbH * Germany Embedded mySCAD Micro SCADA Piciorgros GmbH * Germany PLE - Powerful Java Graphic Editor Piciorgros GmbH * Germany No Cryptic Formulas for Logic design Piciorgros GmbH * Germany Powerful embedded Micro PLC Piciorgros GmbH * Germany TMO-100 TETRA Data Modem Features Piciorgros GmbH * Germany TMO-100 - TETRA related Features SDS can be up to 255 bytes (2047 Bit) long. Type TL and TL 4 Packet Switched Data (IP) supported Single and Multi Slot Packet Data supported Secondary Control Channel supported Automatic PPP Link set up to the TETRA Switch Router Function with Port Forwarding and NAT Up to 3 Watt RF Output Power Authentication, Encryption Voice feature even with active Packet Data Link Build in Tetra Monitor (local and remote) via embedded Web Server Field Strength Indicator on the Front Panel Short Data or SDS can be sent as alarms (low field strength ...) 350 MHz, 380 MHz, 410 MHz 450 MHz and 800 MHz available Piciorgros GmbH * Germany TMO-100 – Protocol and I/O related Features All digital and analog I/O isolated Serial Port COM / AUX available as RS-232 or RS-485/(422) Level 1 Protocol: Timeout or 3964R Device Protocol to access internal Registers: Modbus RTU, Modbus IP, IEC60870-5-101 Serial Protocols supported: Modbus RTU, DNP3, IEC 60870-5-101, PakBus, BSAP, ROC, … user Defined … Ethernet 10/100 MBit IP-Port for Local Network UDP and TCP over TETRA supported E-Mail and TFTP supported Embedded Web Server as Configuration Tool Modbus/IP, IEC 60870-5-104, DNP3/IP, … others … Low Power Consumption: <3 Watt Piciorgros GmbH * Germany PicoLogo™ – User Application Interface Easy to use graphical user interface Optimized for Tetra Infrastructure Basic Logic Functions (and, or, exor, … ) Complex Logic Functions (delay on, delay off, flip flop, …) Analog Functions (analog compare, … ) Timer and Clock Functions (time, date, Dynamic Text Message generation for Alarms and Status GPS Functions (position, … ) Modbus RTU Slave (set and read register, coil, … ) Modbus RTU Master (set and read register, coil, … ) E-Mail send (sending text and alarm messages by e-mail) SNMP Trap (automated machine messaging) … more … Piciorgros GmbH * Germany TMO-100 – Embedded Web Server Web Server to be used local or over TETRA as … Configuration Tool for the Device, Protocols and IP Parameter, Configuration Tool for TETRA Network Parameter, Configuration for the Voice Option TETRA Monitor Device Monitor Error Log Web Server can be accessed locally using the IP Port and remotely over the TETRA Infrastructure Easy to be used with any Web Browser (Firefox, Internet Explorer, … ) Piciorgros GmbH * Germany TMO-100 – Voice Option Standard 8 Pin Connector for Mic. Speaker handset One Group Number (GISSI) to be programmed Eight individual Numbers (ISSI) to be programmed ISSI and GISSI to be programmed locally or remotely using the embedded Web Server Select ISSI / GISSI by Voice Handset Automatic PPP disconnect when pressing PTT Automatic PPP re connect after Voice timeout or reject Piciorgros GmbH * Germany Different SCADA Applications Piciorgros GmbH * Germany ME, Gas and Oil Piciorgros GmbH * Germany Open Pit Mining (Water Level Control) Piciorgros GmbH * Germany Turkey, Mining Application – TETRA DMO Mode Piciorgros GmbH * Germany Asia, Utility (Energy Companies) Pole Mounted Switches Piciorgros GmbH * Germany Waste Water Treatment Plant (Germany) Piciorgros GmbH * Germany Piciorgros GmbH * Germany Funk - Electronic Piciorgros GmbH Claudiastr. 5 51145 Köln-Porz Germany Thank you very much for your interest in our Products www.piciorgros.com www.TetraModem.com Piciorgros GmbH * Germany