Download Event Notification Module - Schneider Electric is the Global

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Microsoft Access wikipedia , lookup

Oracle Database wikipedia , lookup

SQL wikipedia , lookup

Database wikipedia , lookup

Concurrency control wikipedia , lookup

Team Foundation Server wikipedia , lookup

Relational model wikipedia , lookup

Microsoft Jet Database Engine wikipedia , lookup

PL/SQL wikipedia , lookup

Open Database Connectivity wikipedia , lookup

Database model wikipedia , lookup

Btrieve wikipedia , lookup

Ingres (database) wikipedia , lookup

Clusterpoint wikipedia , lookup

ContactPoint wikipedia , lookup

Microsoft SQL Server wikipedia , lookup

Transcript
Event Notification ModuleTM
Installation Guide
Version 7.0
63220-083-03A1
08/2012
Event Notification Module
63220-083-03A1
08/2012
Notices
StruxureWare, StruxureWare Power Monitoring, PowerLogic, Citect, and
Schneider Electric are either trademarks or registered trademarks of
Schneider Electric in France, the USA, and other countries. All other
trademarks are property of their respective owners.
2
© 2012 Schneider Electric. All Rights Reserved.
63220-083-03A1
08/2012
Safety Information
Important Information
Read these instructions carefully and look at the equipment to become
familiar with the device before trying to install, operate, service or
maintain it. The following special messages may appear throughout
this manual or on the equipment to warn of potential hazards or to call
attention to information that clarifies or simplifies a procedure.
The addition of either symbol to a “Danger” or “Warning” safety label
indicates that an electrical hazard exists which will result in personal injury if
the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
DANGER
DANGER indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not
avoided, can result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not
avoided, can result in minor or moderate injury.
NOTICE, is used to address practices not related to physical injury. The
safety alert symbol shall not be used with this signal word.
Please Note
Electrical equipment should be installed, operated, serviced and maintained
only by qualified personnel. No responsibility is assumed by
Schneider Electric for any consequences arising out of the use of this
material.
A qualified person is one who has skills and knowledge related to the
construction, installation, and operation of electrical equipment and has
received safety training to recognize and avoid the hazards involved.
© 2012 Schneider Electric. All Rights Reserved.
3
Table of Contents
63220-083-03A1
08/2012
Introduction ..................................................................................................5
Requirements ..............................................................................................5
Upgrade from Active Pager Module or Event Notification Solution ..............6
Standalone Installation ................................................................................7
Database Server Installation .....................................................................17
Application Server Installation ...................................................................25
4
© 2012 Schneider Electric. All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Introduction
Introduction
Event Notification Module (ENM) installation is one step in the commissioning of a system.
The ENM installer allows for a great deal of flexibility including both local and remote
database instances. To facilitate remote installation, the installer provides three install paths:
Complete Installation: The Event Notification Module and the SQL database will reside on
the same server host. The user selects an SQL instance on the local machine for the install to
configure the database server.
Database Server: Installs the database components on the target database server for Event
Notification Module.
Application Server: The user must select the target database server, but only the
application components will be installed. The user must install the database server first.
Requirements
Note the following system requirements when installing or using Event Management
solutions.
NOTE: For server systems where SQL Server will also be installed, refer to the SQL
requirements to ensure the system can support both SQL and ENM.
Hardware:
Component
Processor
Minimum Requirement
Quad Core
Memory
4 GB
Hard Drive
150 GB
Network
Software:
Component
Required
Operating System
Windows 7 64-bit or 32-bit
Windows Server 2008 SP2
Windows Server 2008 R2
SQL Server
MS SQL Server 2008 or 2008 R2
Language
English
Other
Internet Information Services Version 7.0 or higher
.NET Version 4.0
Internet Explorer 8 (In Compatibility Mode)
© 2012 Schneider Electric All Rights Reserved
5
Event Notification Module
Upgrade from Active Pager Module or Event Notification Solution
63220-083-03A1
08/2012
Upgrade from Active Pager Module or Event Notification Solution
ENM was previously called Active Pager Module (APM 6.3) or Event Notification Solution
(ENS 6.4). The APM 6.3 and ENS 6.4 applications were installed on systems with the
following configuration:
Windows 2008, SQL 2005 Express, IONE 6.0 SP1
To upgrade a system from APM 6.3 or ENS 6.4 to ENM 7.0, follow these steps:
1. Detach the APM database PLES_APM, if the customer wants to preserve this database.
2. Detach the History database PLES_AEHistory, if the customer wants to preserve the
historical data.
3. Uninstall APM and Alarm Sentry or ENS.
4. Upgrade SQL Express 2005 to SQL 2008 Standard or R2.
5. After successfully upgrading SQL server, attach the PLES_APM and PLES_AEHistory
databases if they were saved.
6. (Optional) Upgrade IONE 6.0 SP1 to SPM 7.0 or SPM 7.0.1.
7. On the ENM installer disc, browse to the LegacyCleanup folder.
8. Run the LegacyCleanup.bat file. This utility deletes any files left behind after uninstalling
APM and Alarm Sentry.
9. Start the ENM installer and follow the install steps based on the desired setup type:
•
•
•
6
Standalone - Refer to “Standalone Installation” on page 7.
Database Server - Refer to “Database Server Installation” on page 17.
Application Server - Refer to “Application Server Installation” on page 25.
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Standalone Installation
Standalone Installation
Follow these steps if you are installing the ENM application and the database on the same
server.
1. Insert the ENM Installation disc. The Event Notification Module installation screen
appears.
2. Under Installs, click Event Notification Module to start the installation. The installation
wizard appears.
You can also start the installation by browsing the files on the disc and running Setup.exe.
© 2012 Schneider Electric All Rights Reserved
7
Event Notification Module
Standalone Installation
63220-083-03A1
08/2012
3. License Agreement: Click on I Agree to proceed
4. Setup Type: Select Event Notification Module – Complete and click Next.
8
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Standalone Installation
5. File Destination: Click Next to install ENM in the default location. You can select a
different folder, if desired. You will be prompted to create a new folder if this is a new
install.
NOTE: To select a different install location, click the browse button with 3 dots.
© 2012 Schneider Electric All Rights Reserved
9
Event Notification Module
Standalone Installation
63220-083-03A1
08/2012
6. Database Server: The local database instance is selected by default. The format
displayed is “machine name\database instance”; please ensure it is correct. Enter the
Username and Password login credentials associated with the database and click Next.
NOTE: If you enter the wrong credentials, an error appears.
10
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Standalone Installation
7. Citect Credentials: Enter the credentials for PowerLogic SCADA if this component is
part of the server configuration.
8. Database Maintenance Credentials: Enter the Windows administrator login credentials
associated with the machine that ENM is being installed.
The username and password credentials get verified in the screen that follows.
© 2012 Schneider Electric All Rights Reserved
11
Event Notification Module
Standalone Installation
63220-083-03A1
08/2012
9. Check System: The ENM installer verifies if the requirements are met. If there are any
issues, the installer notifies you to correct the issue.
The installer verifies these items:
•
•
•
•
•
•
•
•
12
Operating System
Previous ENM installs
SQL Server version
Local SQL instance
SQL Server connection
ASP.NET
Database maintenance credentials
SQL Mixed Mode Authentication
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Standalone Installation
10. Ready to Configure: The configuration choices are displayed before being installed.
Please ensure that all items are correct before proceeding.
•
•
© 2012 Schneider Electric All Rights Reserved
Click Back to correct any items.
Click Install to continue. The Copy Files screen appears and the ENM files are
copied to the machine:
13
Event Notification Module
Standalone Installation
63220-083-03A1
08/2012
11. Advosol OPC Core Component: When prompted, accept the license agreement for
Advosol OPC Core Component. Click Next and complete the installation. This component
must be installed.
Configure System: The selected configuration settings are applied.
If any errors occurred, the “Configuration failed” message appears. Resolve the issues as
follows:
•
14
Select the configuration step that failed and click Open Log to diagnose the error.
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Standalone Installation
•
Click the Try Again link to complete that part of the installation.
Configuration Complete: After the ENM installer finishes configuring the system, the
“Configuration Complete” message appears.
© 2012 Schneider Electric All Rights Reserved
15
Event Notification Module
Standalone Installation
63220-083-03A1
08/2012
12. Complete: The Complete page appears after the install is successful.
•
•
Click the Installation Log link to view details recorded for the installation process.
Click Close to finish.
The StruxureWare Solutions shortcut is added to the Windows Desktop.
Refer to the Event Notification Module 7.0 User Guide for instructions to configure and use
ENM.
16
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Database Server Installation
Database Server Installation
Distributed installation requires two machines: the Database server and Application Server.
The ENM database is installed on the Database Server and ENM components are installed
on the Application Server.
NOTE: For a distributed system, install the Database Server before the Application Server.
1. Start the install by running the Setup.exe.
2. License Agreement: Click I Agree to continue.
© 2012 Schneider Electric All Rights Reserved
17
Event Notification Module
Database Server Installation
63220-083-03A1
08/2012
3. Setup Type: Select “Database Server” and click Next.
18
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Database Server Installation
4. File Destination: Click Next to install ENM in the default location. You can select a
different folder, if desired.
You will be prompted to create a new folder if it’s a new install.
5. Database Server: The local database instance is selected by default. The format is
“machine name\database instance”; please ensure it is correct. Enter the Username and
Password login credentials associated with the database and click Next.
© 2012 Schneider Electric All Rights Reserved
19
Event Notification Module
Database Server Installation
63220-083-03A1
08/2012
6. Citect Credentials: Enter the credentials for PowerLogic SCADA if this component is
part of the server configuration.
7. Database Maintenance Credentials: Enter the Windows administrator login credentials
associated with the machine that ENM is being installed.
The username and password credentials get verified in the screen that follows.
20
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Database Server Installation
8. Check System: The ENM installer verifies if the requirements are met. If there are any
issues, the installer notifies you to correct the issues.
The installer verifies the following items:
•
•
•
•
•
•
© 2012 Schneider Electric All Rights Reserved
Operating System
SQL Server version
Local SQL instance
SQL Server connection
Database maintenance credentials
SQL Mixed Mode Authentication
21
Event Notification Module
Database Server Installation
63220-083-03A1
08/2012
9. Ready to Configure: The configuration choices are displayed before being installed.
Please ensure that all items are correct before proceeding.
•
•
Click Back to correct any items.
Click Install to continue. The Copy Files screen appears. The ENM files are copied to
the machine:
10. Configure System: The selected configuration settings are applied.
If any errors occurred, the “Configuration failed” message appears. Resolve the issues as
follows:
•
22
Select the configuration step that failed and click Open Log to diagnose the error.
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Database Server Installation
•
Click the Try Again link to complete that part of the installation.
11. Configuration Complete: If successful the following screen appears.
© 2012 Schneider Electric All Rights Reserved
23
Event Notification Module
Database Server Installation
63220-083-03A1
08/2012
12. Complete: The Complete screen appears after the install is successful.
•
•
24
Click the Installation Log link to view details recorded for the installation process.
Click Close to finish.
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Application Server Installation
Application Server Installation
NOTE: For a distributed system, install the Database Server before the Application Server.
1. Start the ENM installer on the Application Server.
2. License Agreement: Click I Agree to continue.
3. Setup Type: Select “Application Server” and click Next.
© 2012 Schneider Electric All Rights Reserved
25
Event Notification Module
Application Server Installation
63220-083-03A1
08/2012
4. File Destination: Click Next to install in the default location. You can select a different
folder, if desired. You will be prompted to create a new folder if this is a new install.
5. Click Yes to create the new folder.
6. Database Server: The local database instance is selected by default. The format
displayed is “machine name\database instance”; please ensure it is correct. Enter the
Username and Password login credentials associated with the database and click Next.
26
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Application Server Installation
7. Database Maintenance Credentials: Please enter Windows administrator login
credentials associated with the machine that ENM is being installed.
The username and password credentials get verified in the screen that follows.
8. Check System: The ENM installer verifies if the requirements are met. If there are any
issues, the installer notifies you to correct the issues.
The installer verifies the following items:
•
•
•
© 2012 Schneider Electric All Rights Reserved
Operating System
SQL Server connection
Database maintenance credentials
27
Event Notification Module
Application Server Installation
63220-083-03A1
08/2012
9. Ready to Configure: The configuration choices are displayed before being installed.
Please ensure that all items are correct before proceeding.
•
•
28
Click Back to correct any items.
Click Install to continue. The Copy Files screen appears and the ENM files are
copied to the machine:
© 2012 Schneider Electric All Rights Reserved
63220-083-03A1
08/2012
Event Notification Module
Application Server Installation
10. Advosol OPC Core Components: When prompted, accept the license agreement for
Advosol OPC Core Component. Click Next and complete the installation. This component
must be installed.
Configure System: The selected configuration settings are applied. After the ENM
installer finishes configuring the system, the “Configuration Complete” message appears.
If any errors occurred, the “Configuration failed” message appears. Resolve the issues as
follows:
•
•
© 2012 Schneider Electric All Rights Reserved
Select the configuration step that failed and click Open Log to diagnose the error.
Click the Try Again link to complete that part of the installation.
29
Event Notification Module
Application Server Installation
63220-083-03A1
08/2012
11. Complete: The Complete screen appears after the install is successful.
•
•
Click the Installation Log link to view details recorded for the installation process.
Click Close to finish.
The StruxureWare Solutions shortcut is added to the Windows Desktop.
Refer to the Event Notification Module 7.0 User Guide for instructions to configure and use
ENM.
30
© 2012 Schneider Electric All Rights Reserved
Event Notification ModuleTM 7.0
Installation Guide
Schneider Electric
295 Tech Park Drive, Suite 100
LaVergne, TN 37086 USA
For technical support:
[email protected]
(00) + 1 250 544 3010
Contact your local Schneider Electric sales
representative for assistance or go to
www.schneider-electric.com
Electrical equipment should be installed, operated, serviced, and maintained only by qualified
personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of
the use of this material.
63220-083-03A1 08/2012