Download 1 Basic Features - Support

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Variable-frequency drive wikipedia , lookup

Transcript
Document Code
UPS2000
V200R001
Feature Description
Issue
V1.0
Date
2014-06-28
HUAWEI TECHNOLOGIES CO., LTD.
Copyright © Huawei Technologies Co., Ltd. 2014. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address:
Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website:
http://www.huawei.com
Email:
[email protected]
Tel:
0755-28560000
Fax:
0755-28560111
Issue V1.0 (2014-06-28)
4008302118
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
i
UPS2000
Feature Description
Contents
Contents
1 Basic Features ................................................................................................................................. 1
1.1 Features ......................................................................................................................................................................... 1
1.2 Input Features ............................................................................................................................................................... 4
1.3 Bypass and Output Features ......................................................................................................................................... 5
1.4 Battery Features ............................................................................................................................................................ 8
1.5 System Features .......................................................................................................................................................... 10
1.6 User Interface Features ............................................................................................................................................... 10
1.7 Alarm Features ............................................................................................................................................................ 12
2 Optional Features ........................................................................................................................ 15
2.1 Environmental Features .............................................................................................................................................. 15
2.2 Power Distribution Features ....................................................................................................................................... 16
2.3 Battery Features .......................................................................................................................................................... 16
2.4 Monitoring Features.................................................................................................................................................... 18
A Acronyms and Abbreviations .................................................................................................. 20
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
ii
UPS2000
Feature Description
1 Basic Features
1
Basic Features
This document is applied to UPS2000 V200R001.
1.1 Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Summary
Feature No.
Feature Name
One Key-010101
The UPS2000 complies with the International Electrotechnical
Commission (IEC), YD/T1095-2008, and other related standards and
has passed Conformite Europeenne (CE) certification.
One Key-010102
High system efficiency. 1 kVA: 88%; 2 kVA: 89%, 3 kVA: 90%.
One Key-010103
The full-digital design improves system stability and maintainability.
One Key-010104
Having a small footprint and high power density
One Key-010105
Wide operating temperature ranging from 0°C–40°C
One Key-010106
Abundant optional components contribute to an integrated solution.
One Key-010107
Complying with the restriction of the use of certain hazardous
substances (ROHS) R6 and 2002/95/EC
One Key-010108
Input system: The UPS2000-1 kVA/2 kVA/3 kVA supports the
single-phase input and output.
One Key-010109
The UPS is protected to IP20.
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1
UPS2000
Feature Description
1 Basic Features
Benefits
Feature Name
Benefits
The UPS2000 complies with the IEC,
YD/T1095-2008, and other related standards
and has passed CE certification.
Meets all the requirements of safety,
Electromagnetic compatibility (EMC),
performance, and reliability.
High system efficiency. 1 kVA: 88%; 2 kVA:
89%, 3 kVA: 90%.
Improves system efficiency and reduces
energy consumption.
The full-digital design improves system
stability and maintainability.
This feature increases the power density
and improves reliability.
Having a small footprint and high power
density
This feature improves space utilization
and provides reserved space for
redundancy and expansion.
Wide operating temperature ranging from
0°C–40°C
The UPS supports a wide range of
operating temperatures.
Abundant optional components contribute to
an integrated solution.
This feature helps deliver all-around
solutions that are easy to implement.
Complying with the ROHS R6 and
2002/95/EC
The UPS meets environmental
requirements.
Input system: The UPS2000-1 kVA/2 kVA/3
kVA supports the single-phase input and
output. The supported voltage levels include:
200/208/220/230/240 V AC.
Supports various input voltage levels.
The UPS is protected to IP20.
Provides dustproof function.
Description
Feature Name
Description
The UPS2000 complies
with the IEC,
YD/T1095-2008, and other
related standards and has
passed CE, TUV, and TLC
certification.
Meets the requirements of IEC62040 (safety, EMC,
performance, and test method) and YD/T1095-2008 (China
communications standards for UPS), provides the
certification of CE to ensure that the product can be sold to
the place where the corresponding certification is required.
High system efficiency. 1
kVA: 88%; 2 kVA: 89%, 3
kVA: 90%.
High system efficiency:
1 kVA: The total output power/the total input power = 88%.
2 kVA: The total output power/the total input power = 89%.
3 kVA: The total output power/the total input power = 90%.
The full-digital design
improves system stability
and maintainability.
The digital chip control improves system integration,
anti-interference capability, reliability, and maintainability.
Having a small footprint
and high power density
Improves the integration of the system and power output
capacity per unit volume.
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2
UPS2000
Feature Description
1 Basic Features
Feature Name
Description
Wide operating
temperature ranging from
0°C–40°C
The UPS supports a wide range of operating temperatures.
Abundant optional
components contribute to
an integrated solution.
The abundant optional components can be flexibly
configured to meet customer requirements in various
scenarios.
Complying with the ROHS
R6 and 2002/95/EC
RoHS is a mandatory standard developed by the EU
legislation and has been officially carried out since July 1,
2006. This standard regulates the materials and processing
standards of all electrical products, aiming to eliminate the
use of six hazardous substances such as lead, mercury,
cadmium, hexavalent chromium, polybrominated biphenyls,
and polybrominated diphenyl ethers in electrical products.
The standard emphasizes that the content of lead cannot
exceed 0.1%.
Input system: The
UPS2000-1 kVA/2 kVA/3
kVA supports the
single-phase input and
output. The supported
voltage levels include:
200/208/220/230/240 V
AC.
The UPS2000-1 kVA/2 kVA/3 kVA supports single-phase
input and output and various voltage input and output levels
(200/208/220/230/240 V AC).
The UPS is protected to
IP20.
IP20:
2: Prevent foreign objects with a diameter of greater than 12
mm and with a length of less than 80 mm from entering the
cabinet; prevent fingers from touching the electrical
components or moving components inside the cabinet;
0: No protection
The first feature code involves dust prevention, and the
second feature code involves water resistance.
Enhancement
N/A
Dependencies
N/A
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3
UPS2000
Feature Description
1 Basic Features
1.2 Input Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Summary
Feature No.
Feature Name
One Key-020101
Input system: The UPS2000-1 kVA/2 kVA/3 kVA supports the
single-phase input and output.
The supported input voltage levels include: 200/208/220/230/240 V
AC.
One Key-020102
Input voltage range: 110 V AC to 300 V AC
One Key-020103
The input voltage and frequency have a wide range. The frequency is
40–70 Hz.
One Key-020104
The input power factor (PF) is high: > 0.99 at full load
One Key-020105
Total harmonic distortion of current (THDi): < 10%
Feature Name
Benefits
Input system: The UPS2000-1 kVA/2
kVA/3 kVA supports the single-phase
input and output.
Meets requirements for single-phase input and
output.
Benefits
The supported input voltage levels
include: 200/208/220/230/240 V AC.
Input voltage range: 110 V AC to 300 V
AC
This feature reduces the battery discharge
possibility and lengthens the battery lifespan.
The input voltage and frequency have a
wide range. The frequency is 40–70 Hz.
This feature reduces the battery discharge
possibility and lengthens the battery lifespan.
The input PF is high: > 0.99 at full load.
The input PF is high, which improves energy
utilization.
THDi < 10%
This feature improves voltage quality and
reduces cable loss.
Description
Feature Name
Description
Input system: The UPS2000-1 kVA/2
kVA/3 kVA supports the single-phase input
Supports single-phase input and output and
various input and output voltage levels to
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4
UPS2000
Feature Description
1 Basic Features
Feature Name
Description
and output.
satisfy diverse application scenarios in
different regions.
The supported input voltage levels include:
200/208/220/230/240 V AC.
Input voltage range: 110 V AC to 300 V AC
The input voltage ranges from 110 V AC to
300 V AC. When the system is not
overloaded, the UPS works in normal mode.
The input voltage and frequency have a
wide range. The frequency is 40–70 Hz.
The input frequency ranges from 40 Hz to
70 Hz. The UPS output frequency meets
requirements.
The input PF is high: > 0.99 at full load.
The single-phase input PF can achieve at
least 0.99 at full load.
THDi < 10%
The THDi is less than 10%.
Enhancement
N/A
Dependencies
N/A
1.3 Bypass and Output Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Summary
Feature No.
Feature Name
One Key-030101
The output voltage level is configurable, including
200/208/220/230/240 V AC.
One Key-030102
The rated output frequency is 50 Hz or 60 Hz.
One Key-030103
The Output power factor is 0.8.
One Key-030104
The output current peak factor is 3:1.
One Key-030105
Dynamic voltage transient <5%
One Key-030106
The THDu is small: ≤ 3% (linear load) or ≤ 6% (non-linear load).
One Key-030107
The frequency tolerance is ±0.1 Hz (local frequency mode)
One Key-030108
Powerful overload capacity:
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5
UPS2000
Feature Description
1 Basic Features
Feature No.
Feature Name
If the load is at 105%–110%, the UPS transfers to bypass mode in 10
minutes.
If the load is at 110%–130%, the UPS transfers to bypass mode in 1
minute.
If the load is at 130%, the UPS transfers to bypass mode in 3 seconds.
One Key-030109
The UPS adapts well to capacitive loads.
One Key-030110
The bypass voltage has a wide range: supports a maximum of
176–264 V.
One Key-030111
The inverter rate frequency has a tolerance of ±3 Hz.
One Key-030112
The UPS supports ECO mode.
Benefits
Feature Name
Benefits
The output voltage level is configurable,
including 200/208/220/230/240 V AC.
Satisfies various market requirements
and allows for flexible voltage
adjustments via clients.
The rated output frequency is 50 Hz or 60 Hz.
Customers can adjust the output
voltage flexibly.
The Output power factor is 0.8.
With the output power factor being as
high as 0.8, the system can connect to
more loads at the same power.
The output current peak factor is 3:1.
The UPS supports non-linear loads.
Dynamic voltage transient <5%
The UPS provides high-quality output
voltages.
The THDu is small: ≤ 3% (linear load) or ≤ 6%
(non-linear load).
Enables the USP to support various
loads.
The frequency tolerance is ±0.1 Hz (local
frequency mode)
Enables the USP to support various
loads.
Powerful overload capacity:
If the load is at 105%-110%, the UPS transfers to
bypass mode in 10 minutes.
This feature improves system
reliability.
If the load is at 110%-130%, the UPS transfers to
bypass mode in 1 minute.
If the load is at 130%, the UPS transfers to
bypass mode in 3 seconds.
The UPS adapts well to capacitive loads.
The UPS supports non-linear loads.
The bypass voltage has a wide range: supports a
maximum of 176–264 V.
Wide-range input voltage is supported.
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6
UPS2000
Feature Description
1 Basic Features
Feature Name
Benefits
The inverter rate frequency has a tolerance of ±3
Hz.
This feature improves system
reliability.
The UPS supports ECO mode.
The UPS is energy efficient and
eco-friendly with good power supply.
Description
Feature Name
Description
The output voltage level is configurable,
including 200/208/220/230/240 V AC.
The output voltage level is configurable,
including 200/208/220/230/240 V AC.
The rated output frequency is 50 Hz or 60
Hz.
The rated output frequency can be set to 50
Hz or 60 Hz.
The Output power factor is 0.8.
The active output power stays 80% of the
total power.
The output current peak factor is 3:1.
The UPS meets the requirement that the peak
output current triples the rated current.
Dynamic voltage transient <5%
When loads vary in the range of 0% and
100%, the output voltage varies within the
tolerance of 5%.
The THDu is small: ≤ 3% (linear load) or
≤ 6% (non-linear load).
The THDu is small: ≤ 3% (linear load) or ≤
6% (non-linear load).
The frequency tolerance is ±0.1 Hz (local
frequency mode)
The frequency tolerance is ±0.1 Hz (local
frequency mode)
Powerful overload capacity:
If the load is at 105%–110%, the UPS
transfers to bypass mode in 10 minutes.
Powerful overload capacity:
If the load is at 105%–110%, the UPS
transfers to bypass mode in 10 minutes.
If the load is at 110%–130%, the UPS
transfers to bypass mode in 1 minute.
If the load is at 110%–130%, the UPS
transfers to bypass mode in 1 minute.
If the load is at 130%, the UPS transfers to
bypass mode in 3 seconds.
If the load is at 130%, the UPS transfers to
bypass mode in 3 seconds.
The UPS adapts well to capacitive loads.
The UPS supports non-linear loads.
The bypass voltage has a wide range:
supports a maximum of 176–264 V.
The bypass voltage range is at a maximum of
176 to 264 V and can be adjusted at a
tolerance.
The inverter rate frequency has a tolerance
of ±3 Hz.
The inverter tracking frequency tolerance is
±3 Hz.
The UPS supports ECO mode.
The bypass can supply power directly to loads
if the bypass voltage is within the specified
range.
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7
UPS2000
Feature Description
1 Basic Features
Enhancement
N/A
Dependencies
N/A
1.4 Battery Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Summary
Feature No.
Feature Name
One Key-040101
Battery voltage:
A standard UPS2000-1 kVA: two batteries
A UPS2000-1 kVA with extended backup time: three batteries
A standard UPS2000-2 kVA: four batteries
A UPS2000-2 kVA with extended backup time: six batteries
A standard UPS2000-3 kVA: six batteries
A UPS2000-3 kVA with extended backup time: eight batteries
One Key-040102
The UPS supports lead-acid batteries (open or valve regulated).
One Key-040103
The UPS supports one-button cold startup. During a mains outage,
batteries can start the UPS to supply power to loads.
One Key-040104
Intelligent management, automatic temperature compensation,
backup time assessment, capacity monitoring, and battery self-check
and maintenance
Benefits
Feature Name
Benefits
Battery voltage:
A standard UPS2000-1 kVA: two batteries
A UPS2000-1 kVA with extended backup time: three
batteries
A standard UPS2000-2 kVA: four batteries
A UPS2000-2 kVA with extended backup time: six
batteries
A standard UPS2000-3 kVA: six batteries
A UPS2000-3 kVA with extended backup time: eight
batteries
This feature provides various
battery configuration methods.
The UPS supports lead-acid batteries (open or valve
The battery type can be selected
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8
UPS2000
Feature Description
1 Basic Features
Feature Name
Benefits
regulated).
based on the actual requirements.
The UPS supports one-button cold startup. During a
mains outage, batteries can start the UPS to supply
power to loads.
This feature reduces maintenance
costs and supports battery cold
startup.
Intelligent management, automatic temperature
compensation, backup time assessment, capacity
monitoring, and battery self-check and maintenance
This feature maximizes battery
utilization.
Description
Feature Name
Description
Battery voltage:
A standard UPS2000-1 kVA: two batteries
A UPS2000-1 kVA with extended backup time:
three batteries
A standard UPS2000-2 kVA: four batteries
A UPS2000-2 kVA with extended backup time:
six batteries
A standard UPS2000-3 kVA: six batteries
A UPS2000-3 kVA with extended backup time:
eight batteries
Various battery voltages are
available, supporting diverse
requirements of battery voltages for
different models.
The UPS supports lead-acid batteries (open or
valve regulated).
The UPS supports lead-acid batteries
(open or valve regulated).
The UPS supports one-button cold startup. During
a mains outage, batteries can start the UPS to
supply power to loads.
Batteries supply power to loads if the
mains is abnormal.
Intelligent management, automatic temperature
compensation, backup time assessment, capacity
monitoring, and battery self-check and
maintenance
This feature maximizes battery
utilization.
Enhancement
N/A
Dependencies
N/A
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9
UPS2000
Feature Description
1 Basic Features
1.5 System Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Summary
Feature No.
Feature Name
One Key-050101
Supports the ECO mode.
Benefits
Feature Name
Benefits
ECO mode supported
The UPS2000 is efficient, energy-saving, and cost efficient.
Feature Name
Description
ECO mode supported
The bypass can supply power to loads when the requirements
are met.
Description
Enhancement
N/A
Dependencies
N/A
1.6 User Interface Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
10
UPS2000
Feature Description
1 Basic Features
Summary
Feature No.
Feature Name
One Key-060101
Provides user-friendly interface, displays information graphically on
the LCD, and provides a buzzer for audible alarms. Both Chinese and
English are supported.
One Key-060102
Users can query and remotely download information.
One Key-060103
Provides various external communications ports, such as the USB, RJ45,
and DB9. It supports the network energy element management protocol,
Modbus protocol, and SNMP.
One Key-060104
Integrated management and monitoring of the equipment room,
including the UPS
One Key-060105
Remote monitoring, communication, and control are supported.
Remote communication requires a short message system (SMS)
modem on the client.
Benefits
Feature Name
Benefits
Provides user-friendly interface, displays
information graphically on the LCD, and provides
a buzzer for audible alarms. Both Chinese and
English are supported.
Provides all kinds of running data,
operating status, and help
information.
Users can query and remotely download
information.
Provides historical records for
preventive maintenance inspection.
Provides various external communications ports, such
as the USB, RJ45, and DB9. It supports the network
energy element management protocol, Modbus
protocol, and SNMP.
Various communications and
monitoring ports are available.
Integrated management and monitoring of the
equipment room, including the UPS
Accesses network management
system.
Remote monitoring, communication, and control
are supported. Remote communication requires an
SMS modem on the client.
This feature improves the
maintenance and use efficiency and
reduces the operating cost.
Feature Name
Description
Provides user-friendly interface, displays
information graphically on the LCD, and generates
audible and visual alarms. Both Chinese and
English are supported.
Displays and queries real-time
information on the LCD.
Description
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
11
UPS2000
Feature Description
1 Basic Features
Feature Name
Description
Users can query and remotely download
information.
Users can query and remotely
download information.
Provides various external communications ports,
such as the USB, RJ45, and DB9. It supports the
network energy element management protocol,
Modbus protocol, and SNMP.
Provides various ports, such as the
USB, RJ45, and DB9, and supports
access to the NetEco and network
energy element management
protocol.
Integrated management and monitoring of the
equipment room, including the UPS
Monitors the UPS system by using
the network management system
Remote monitoring, communication, and control
are supported. Remote communication requires an
SMS modem on the client.
The UPS has remote management,
reporting, and control functions.
Enhancement
N/A
Dependencies
N/A
1.7 Alarm Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Summary
Feature No.
Feature Name
One Key-070101
Startup failure
One Key-070102
Overvoltage
One Key-070103
Bus undervoltage
One Key-070104
Bus voltage imbalance
One Key-070105
Inverter soft startup failure
One Key-070106
Inverter overvoltage
One Key-070107
Inverter undervoltage
One Key-070108
Inverter output short circuit
One Key-07019
Battery overvoltage
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
12
UPS2000
Feature Description
1 Basic Features
Feature No.
Feature Name
One Key-070110
Battery undervoltage
One Key-070111
Overtemperature
One Key-070112
Overload
One Key-070113
Charger fault
One Key-070114
Insufficient battery capacity
One Key-070115
Bypass mode
One Key-070116
Error
Benefits
Feature Name
Benefits
Startup failure
Monitors the UPS and reports alarms in real time.
Overvoltage
Monitors the UPS and reports alarms in real time.
Bus undervoltage
Monitors the UPS and reports alarms in real time.
Bus voltage imbalance
Monitors the UPS and reports alarms in real time.
Inverter soft startup failure
Monitors the UPS and reports alarms in real time.
Inverter overvoltage
Monitors the UPS and reports alarms in real time.
Inverter undervoltage
Monitors the UPS and reports alarms in real time.
Inverter output short circuit
Monitors the UPS and reports alarms in real time.
Battery overvoltage
Monitors the UPS and reports alarms in real time.
Battery undervoltage
Monitors the UPS and reports alarms in real time.
Overtemperature
Monitors the UPS and reports alarms in real time.
Overload
Monitors the UPS and reports alarms in real time.
Charger fault
Monitors the UPS and reports alarms in real time.
Insufficient battery capacity
Monitors the UPS and reports alarms in real time.
Bypass mode
Monitors the UPS and reports alarms in real time.
Error
Monitors the UPS and reports alarms in real time.
Startup failure
Monitors the UPS and reports alarms in real time.
Overvoltage
Monitors the UPS and reports alarms in real time.
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
13
UPS2000
Feature Description
1 Basic Features
Description
Feature Name
Description
Startup failure
Reports alarms when the mains soft startup or inverter soft
startup fails.
Overvoltage
Reports alarms when the mains input voltage is higher than the
normal range.
Bus undervoltage
Reports alarms when the bus voltage is lower than the normal
range.
Bus voltage imbalance
Reports alarms when the bus voltage is unbalanced.
Inverter soft startup
failure
Reports alarms when the inverter fails to start properly.
Inverter overvoltage
Reports alarms when the inverter output voltage exceeds the
upper threshold.
Inverter undervoltage
Reports alarms when the inverter output voltage is lower than
the lower threshold.
Inverter output short
circuit
Reports alarms when an Inverter output short circuit occurs.
Battery overvoltage
Reports alarms when the battery voltage exceeds the upper
threshold.
Battery undervoltage
Reports alarms when the battery voltage is lower than the lower
threshold.
Overtemperature
Reports alarms when the UPS is experiencing a high
temperature.
Overload
Reports alarms when the UPS is overloaded.
Charger fault
Reports alarms when the charger is faulty.
Insufficient battery
capacity
Reports alarms when the battery capacity is insufficient.
Bypass mode
The buzzer alarm buzzes when the UPS enters the bypass mode.
Error
Reports alarms when the UPS is experiencing an error.
Enhancement
N/A
Dependencies
N/A
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
14
UPS2000
Feature Description
2 Optional Features
2
Optional Features
2.1 Environmental Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Summary
Feature No.
Feature Name
One Key -080101
EMD optional component (ambient temperature and humidity
sensor with two dry contact inputs)
Benefits
Feature Name
Benefits
EMD optional component (ambient
temperature and humidity sensor with
two dry contact inputs)
Monitors the ambient temperature and humidity
of the UPS to ensure that it works in a normal
condition.
Description
Feature Name
Description
EMD optional component (ambient
temperature and humidity sensor with
two dry contact inputs)
The EMD optional component ensures that the
UPS system works at proper temperature and
humidity.
Enhancement
N/A
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15
UPS2000
Feature Description
2 Optional Features
Dependencies
N/A
2.2 Power Distribution Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Summary
Feature No.
Feature Name
One Key -090102
AC power cable
Benefits
Feature Name
Benefits
AC power cable
Provides input and output cables that support various input systems.
Feature Name
Description
AC power cable
AC power cable (250 V 16 A) applicable in the UK: black, 3-meter
long, and C19SF
Description
Enhancement
N/A
Dependencies
N/A
2.3 Battery Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
16
UPS2000
Feature Description
2 Optional Features
Summary
Feature No.
Feature Name
One Key-110101
Standard external battery box, which can be expanded in parallel.
One Key-110102
External battery rack
One Key-110103
External battery charger
Benefits
Feature Name
Benefits
Standard external battery box,
which can be expanded in parallel.
Provides battery cabinets for lead-acid batteries with
a capacity less than 9 Ah.
External battery rack
Provides battery racks for lead-acid batteries with a
capacity more than 26 Ah.
External battery charger
Provides large charging currents to fast charge the
UPS with an extended backup time and reduce
power failures.
Description
Feature Name
Description
Standard external battery box, which
can be expanded in parallel.
Provides battery cabinets for lead-acid batteries
with a capacity less than 9 Ah.
External battery rack
Provides battery racks for lead-acid batteries with a
capacity more than 26 Ah.
External battery charger
A 10 A large-current charger rapidly charges the
large-capacity batteries.
Enhancement
N/A
Dependencies
N/A
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
17
UPS2000
Feature Description
2 Optional Features
2.4 Monitoring Features
Availability
This feature is introduced to UPS2000 V200R001 and later versions.
Summary
Feature No.
Feature Name
One Key-120101
SNMP card
One Key-120102
Modbus card
One Key-120103
Dry contact output card
One Key-120104
Network management software
Benefits
Feature Name
Benefits
SNMP card
Monitors and manages the UPS remotely.
Modbus card
Used for the building management system (BMS).
Dry contact output card
Manages and reports UPS status.
Network management software
Monitors the system on the WebUI.
Description
Feature Name
Description
SNMP card
The SNMP card implements web monitoring over TCP/IP, supports
remote control, and provides extended network ports.
Modbus card
The Modbus card obtains converted data over Ethernet port,
transparently transmits data between the communication ports, such as
RS232 to RS485, or TCPIC to RS485, and supports other transmission
mode in various application scenarios. Users develop the interface by
using configuration software or software provided by Huawei and
monitor the system online and remotely over Modbus TCP.
Dry contact
output card
The dry contact output card shuts down the UPS remotely or reports
the USP battery status, bypass status, and faults.
Network
management
software
The network management software Monitors the system on the
WebUI.
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
18
UPS2000
Feature Description
2 Optional Features
Enhancement
N/A
Dependencies
N/A
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
19
UPS2000
Feature Description
A Acronyms and Abbreviations
A
Acronyms and Abbreviations
Table 2-1 Acronyms and Abbreviations
Acronym or Abbreviation
Full Name
IEC
International Electrotechnical Commission
CE
Conformité Européenne
TUV
Technical Inspection Association
ROHS
Restriction of hazardous substances
THDi
Total harmonic distortion of current
ECO
Economic
UPS
Uninterruptible power supply
PDU
Power distribution unit
STS
Static transfer switch
SNMP
Simple network management protocol
Issue V1.0 (2014-06-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
20