Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Document Code UPS2000 V200R001 Feature Description Issue V1.0 Date 2014-06-28 HUAWEI TECHNOLOGIES CO., LTD. Copyright © Huawei Technologies Co., Ltd. 2014. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: [email protected] Tel: 0755-28560000 Fax: 0755-28560111 Issue V1.0 (2014-06-28) 4008302118 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. i UPS2000 Feature Description Contents Contents 1 Basic Features ................................................................................................................................. 1 1.1 Features ......................................................................................................................................................................... 1 1.2 Input Features ............................................................................................................................................................... 4 1.3 Bypass and Output Features ......................................................................................................................................... 5 1.4 Battery Features ............................................................................................................................................................ 8 1.5 System Features .......................................................................................................................................................... 10 1.6 User Interface Features ............................................................................................................................................... 10 1.7 Alarm Features ............................................................................................................................................................ 12 2 Optional Features ........................................................................................................................ 15 2.1 Environmental Features .............................................................................................................................................. 15 2.2 Power Distribution Features ....................................................................................................................................... 16 2.3 Battery Features .......................................................................................................................................................... 16 2.4 Monitoring Features.................................................................................................................................................... 18 A Acronyms and Abbreviations .................................................................................................. 20 Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. ii UPS2000 Feature Description 1 Basic Features 1 Basic Features This document is applied to UPS2000 V200R001. 1.1 Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Summary Feature No. Feature Name One Key-010101 The UPS2000 complies with the International Electrotechnical Commission (IEC), YD/T1095-2008, and other related standards and has passed Conformite Europeenne (CE) certification. One Key-010102 High system efficiency. 1 kVA: 88%; 2 kVA: 89%, 3 kVA: 90%. One Key-010103 The full-digital design improves system stability and maintainability. One Key-010104 Having a small footprint and high power density One Key-010105 Wide operating temperature ranging from 0°C–40°C One Key-010106 Abundant optional components contribute to an integrated solution. One Key-010107 Complying with the restriction of the use of certain hazardous substances (ROHS) R6 and 2002/95/EC One Key-010108 Input system: The UPS2000-1 kVA/2 kVA/3 kVA supports the single-phase input and output. One Key-010109 The UPS is protected to IP20. Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 1 UPS2000 Feature Description 1 Basic Features Benefits Feature Name Benefits The UPS2000 complies with the IEC, YD/T1095-2008, and other related standards and has passed CE certification. Meets all the requirements of safety, Electromagnetic compatibility (EMC), performance, and reliability. High system efficiency. 1 kVA: 88%; 2 kVA: 89%, 3 kVA: 90%. Improves system efficiency and reduces energy consumption. The full-digital design improves system stability and maintainability. This feature increases the power density and improves reliability. Having a small footprint and high power density This feature improves space utilization and provides reserved space for redundancy and expansion. Wide operating temperature ranging from 0°C–40°C The UPS supports a wide range of operating temperatures. Abundant optional components contribute to an integrated solution. This feature helps deliver all-around solutions that are easy to implement. Complying with the ROHS R6 and 2002/95/EC The UPS meets environmental requirements. Input system: The UPS2000-1 kVA/2 kVA/3 kVA supports the single-phase input and output. The supported voltage levels include: 200/208/220/230/240 V AC. Supports various input voltage levels. The UPS is protected to IP20. Provides dustproof function. Description Feature Name Description The UPS2000 complies with the IEC, YD/T1095-2008, and other related standards and has passed CE, TUV, and TLC certification. Meets the requirements of IEC62040 (safety, EMC, performance, and test method) and YD/T1095-2008 (China communications standards for UPS), provides the certification of CE to ensure that the product can be sold to the place where the corresponding certification is required. High system efficiency. 1 kVA: 88%; 2 kVA: 89%, 3 kVA: 90%. High system efficiency: 1 kVA: The total output power/the total input power = 88%. 2 kVA: The total output power/the total input power = 89%. 3 kVA: The total output power/the total input power = 90%. The full-digital design improves system stability and maintainability. The digital chip control improves system integration, anti-interference capability, reliability, and maintainability. Having a small footprint and high power density Improves the integration of the system and power output capacity per unit volume. Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 2 UPS2000 Feature Description 1 Basic Features Feature Name Description Wide operating temperature ranging from 0°C–40°C The UPS supports a wide range of operating temperatures. Abundant optional components contribute to an integrated solution. The abundant optional components can be flexibly configured to meet customer requirements in various scenarios. Complying with the ROHS R6 and 2002/95/EC RoHS is a mandatory standard developed by the EU legislation and has been officially carried out since July 1, 2006. This standard regulates the materials and processing standards of all electrical products, aiming to eliminate the use of six hazardous substances such as lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers in electrical products. The standard emphasizes that the content of lead cannot exceed 0.1%. Input system: The UPS2000-1 kVA/2 kVA/3 kVA supports the single-phase input and output. The supported voltage levels include: 200/208/220/230/240 V AC. The UPS2000-1 kVA/2 kVA/3 kVA supports single-phase input and output and various voltage input and output levels (200/208/220/230/240 V AC). The UPS is protected to IP20. IP20: 2: Prevent foreign objects with a diameter of greater than 12 mm and with a length of less than 80 mm from entering the cabinet; prevent fingers from touching the electrical components or moving components inside the cabinet; 0: No protection The first feature code involves dust prevention, and the second feature code involves water resistance. Enhancement N/A Dependencies N/A Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 3 UPS2000 Feature Description 1 Basic Features 1.2 Input Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Summary Feature No. Feature Name One Key-020101 Input system: The UPS2000-1 kVA/2 kVA/3 kVA supports the single-phase input and output. The supported input voltage levels include: 200/208/220/230/240 V AC. One Key-020102 Input voltage range: 110 V AC to 300 V AC One Key-020103 The input voltage and frequency have a wide range. The frequency is 40–70 Hz. One Key-020104 The input power factor (PF) is high: > 0.99 at full load One Key-020105 Total harmonic distortion of current (THDi): < 10% Feature Name Benefits Input system: The UPS2000-1 kVA/2 kVA/3 kVA supports the single-phase input and output. Meets requirements for single-phase input and output. Benefits The supported input voltage levels include: 200/208/220/230/240 V AC. Input voltage range: 110 V AC to 300 V AC This feature reduces the battery discharge possibility and lengthens the battery lifespan. The input voltage and frequency have a wide range. The frequency is 40–70 Hz. This feature reduces the battery discharge possibility and lengthens the battery lifespan. The input PF is high: > 0.99 at full load. The input PF is high, which improves energy utilization. THDi < 10% This feature improves voltage quality and reduces cable loss. Description Feature Name Description Input system: The UPS2000-1 kVA/2 kVA/3 kVA supports the single-phase input Supports single-phase input and output and various input and output voltage levels to Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 4 UPS2000 Feature Description 1 Basic Features Feature Name Description and output. satisfy diverse application scenarios in different regions. The supported input voltage levels include: 200/208/220/230/240 V AC. Input voltage range: 110 V AC to 300 V AC The input voltage ranges from 110 V AC to 300 V AC. When the system is not overloaded, the UPS works in normal mode. The input voltage and frequency have a wide range. The frequency is 40–70 Hz. The input frequency ranges from 40 Hz to 70 Hz. The UPS output frequency meets requirements. The input PF is high: > 0.99 at full load. The single-phase input PF can achieve at least 0.99 at full load. THDi < 10% The THDi is less than 10%. Enhancement N/A Dependencies N/A 1.3 Bypass and Output Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Summary Feature No. Feature Name One Key-030101 The output voltage level is configurable, including 200/208/220/230/240 V AC. One Key-030102 The rated output frequency is 50 Hz or 60 Hz. One Key-030103 The Output power factor is 0.8. One Key-030104 The output current peak factor is 3:1. One Key-030105 Dynamic voltage transient <5% One Key-030106 The THDu is small: ≤ 3% (linear load) or ≤ 6% (non-linear load). One Key-030107 The frequency tolerance is ±0.1 Hz (local frequency mode) One Key-030108 Powerful overload capacity: Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 5 UPS2000 Feature Description 1 Basic Features Feature No. Feature Name If the load is at 105%–110%, the UPS transfers to bypass mode in 10 minutes. If the load is at 110%–130%, the UPS transfers to bypass mode in 1 minute. If the load is at 130%, the UPS transfers to bypass mode in 3 seconds. One Key-030109 The UPS adapts well to capacitive loads. One Key-030110 The bypass voltage has a wide range: supports a maximum of 176–264 V. One Key-030111 The inverter rate frequency has a tolerance of ±3 Hz. One Key-030112 The UPS supports ECO mode. Benefits Feature Name Benefits The output voltage level is configurable, including 200/208/220/230/240 V AC. Satisfies various market requirements and allows for flexible voltage adjustments via clients. The rated output frequency is 50 Hz or 60 Hz. Customers can adjust the output voltage flexibly. The Output power factor is 0.8. With the output power factor being as high as 0.8, the system can connect to more loads at the same power. The output current peak factor is 3:1. The UPS supports non-linear loads. Dynamic voltage transient <5% The UPS provides high-quality output voltages. The THDu is small: ≤ 3% (linear load) or ≤ 6% (non-linear load). Enables the USP to support various loads. The frequency tolerance is ±0.1 Hz (local frequency mode) Enables the USP to support various loads. Powerful overload capacity: If the load is at 105%-110%, the UPS transfers to bypass mode in 10 minutes. This feature improves system reliability. If the load is at 110%-130%, the UPS transfers to bypass mode in 1 minute. If the load is at 130%, the UPS transfers to bypass mode in 3 seconds. The UPS adapts well to capacitive loads. The UPS supports non-linear loads. The bypass voltage has a wide range: supports a maximum of 176–264 V. Wide-range input voltage is supported. Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 6 UPS2000 Feature Description 1 Basic Features Feature Name Benefits The inverter rate frequency has a tolerance of ±3 Hz. This feature improves system reliability. The UPS supports ECO mode. The UPS is energy efficient and eco-friendly with good power supply. Description Feature Name Description The output voltage level is configurable, including 200/208/220/230/240 V AC. The output voltage level is configurable, including 200/208/220/230/240 V AC. The rated output frequency is 50 Hz or 60 Hz. The rated output frequency can be set to 50 Hz or 60 Hz. The Output power factor is 0.8. The active output power stays 80% of the total power. The output current peak factor is 3:1. The UPS meets the requirement that the peak output current triples the rated current. Dynamic voltage transient <5% When loads vary in the range of 0% and 100%, the output voltage varies within the tolerance of 5%. The THDu is small: ≤ 3% (linear load) or ≤ 6% (non-linear load). The THDu is small: ≤ 3% (linear load) or ≤ 6% (non-linear load). The frequency tolerance is ±0.1 Hz (local frequency mode) The frequency tolerance is ±0.1 Hz (local frequency mode) Powerful overload capacity: If the load is at 105%–110%, the UPS transfers to bypass mode in 10 minutes. Powerful overload capacity: If the load is at 105%–110%, the UPS transfers to bypass mode in 10 minutes. If the load is at 110%–130%, the UPS transfers to bypass mode in 1 minute. If the load is at 110%–130%, the UPS transfers to bypass mode in 1 minute. If the load is at 130%, the UPS transfers to bypass mode in 3 seconds. If the load is at 130%, the UPS transfers to bypass mode in 3 seconds. The UPS adapts well to capacitive loads. The UPS supports non-linear loads. The bypass voltage has a wide range: supports a maximum of 176–264 V. The bypass voltage range is at a maximum of 176 to 264 V and can be adjusted at a tolerance. The inverter rate frequency has a tolerance of ±3 Hz. The inverter tracking frequency tolerance is ±3 Hz. The UPS supports ECO mode. The bypass can supply power directly to loads if the bypass voltage is within the specified range. Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 7 UPS2000 Feature Description 1 Basic Features Enhancement N/A Dependencies N/A 1.4 Battery Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Summary Feature No. Feature Name One Key-040101 Battery voltage: A standard UPS2000-1 kVA: two batteries A UPS2000-1 kVA with extended backup time: three batteries A standard UPS2000-2 kVA: four batteries A UPS2000-2 kVA with extended backup time: six batteries A standard UPS2000-3 kVA: six batteries A UPS2000-3 kVA with extended backup time: eight batteries One Key-040102 The UPS supports lead-acid batteries (open or valve regulated). One Key-040103 The UPS supports one-button cold startup. During a mains outage, batteries can start the UPS to supply power to loads. One Key-040104 Intelligent management, automatic temperature compensation, backup time assessment, capacity monitoring, and battery self-check and maintenance Benefits Feature Name Benefits Battery voltage: A standard UPS2000-1 kVA: two batteries A UPS2000-1 kVA with extended backup time: three batteries A standard UPS2000-2 kVA: four batteries A UPS2000-2 kVA with extended backup time: six batteries A standard UPS2000-3 kVA: six batteries A UPS2000-3 kVA with extended backup time: eight batteries This feature provides various battery configuration methods. The UPS supports lead-acid batteries (open or valve The battery type can be selected Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 8 UPS2000 Feature Description 1 Basic Features Feature Name Benefits regulated). based on the actual requirements. The UPS supports one-button cold startup. During a mains outage, batteries can start the UPS to supply power to loads. This feature reduces maintenance costs and supports battery cold startup. Intelligent management, automatic temperature compensation, backup time assessment, capacity monitoring, and battery self-check and maintenance This feature maximizes battery utilization. Description Feature Name Description Battery voltage: A standard UPS2000-1 kVA: two batteries A UPS2000-1 kVA with extended backup time: three batteries A standard UPS2000-2 kVA: four batteries A UPS2000-2 kVA with extended backup time: six batteries A standard UPS2000-3 kVA: six batteries A UPS2000-3 kVA with extended backup time: eight batteries Various battery voltages are available, supporting diverse requirements of battery voltages for different models. The UPS supports lead-acid batteries (open or valve regulated). The UPS supports lead-acid batteries (open or valve regulated). The UPS supports one-button cold startup. During a mains outage, batteries can start the UPS to supply power to loads. Batteries supply power to loads if the mains is abnormal. Intelligent management, automatic temperature compensation, backup time assessment, capacity monitoring, and battery self-check and maintenance This feature maximizes battery utilization. Enhancement N/A Dependencies N/A Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 9 UPS2000 Feature Description 1 Basic Features 1.5 System Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Summary Feature No. Feature Name One Key-050101 Supports the ECO mode. Benefits Feature Name Benefits ECO mode supported The UPS2000 is efficient, energy-saving, and cost efficient. Feature Name Description ECO mode supported The bypass can supply power to loads when the requirements are met. Description Enhancement N/A Dependencies N/A 1.6 User Interface Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 10 UPS2000 Feature Description 1 Basic Features Summary Feature No. Feature Name One Key-060101 Provides user-friendly interface, displays information graphically on the LCD, and provides a buzzer for audible alarms. Both Chinese and English are supported. One Key-060102 Users can query and remotely download information. One Key-060103 Provides various external communications ports, such as the USB, RJ45, and DB9. It supports the network energy element management protocol, Modbus protocol, and SNMP. One Key-060104 Integrated management and monitoring of the equipment room, including the UPS One Key-060105 Remote monitoring, communication, and control are supported. Remote communication requires a short message system (SMS) modem on the client. Benefits Feature Name Benefits Provides user-friendly interface, displays information graphically on the LCD, and provides a buzzer for audible alarms. Both Chinese and English are supported. Provides all kinds of running data, operating status, and help information. Users can query and remotely download information. Provides historical records for preventive maintenance inspection. Provides various external communications ports, such as the USB, RJ45, and DB9. It supports the network energy element management protocol, Modbus protocol, and SNMP. Various communications and monitoring ports are available. Integrated management and monitoring of the equipment room, including the UPS Accesses network management system. Remote monitoring, communication, and control are supported. Remote communication requires an SMS modem on the client. This feature improves the maintenance and use efficiency and reduces the operating cost. Feature Name Description Provides user-friendly interface, displays information graphically on the LCD, and generates audible and visual alarms. Both Chinese and English are supported. Displays and queries real-time information on the LCD. Description Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 11 UPS2000 Feature Description 1 Basic Features Feature Name Description Users can query and remotely download information. Users can query and remotely download information. Provides various external communications ports, such as the USB, RJ45, and DB9. It supports the network energy element management protocol, Modbus protocol, and SNMP. Provides various ports, such as the USB, RJ45, and DB9, and supports access to the NetEco and network energy element management protocol. Integrated management and monitoring of the equipment room, including the UPS Monitors the UPS system by using the network management system Remote monitoring, communication, and control are supported. Remote communication requires an SMS modem on the client. The UPS has remote management, reporting, and control functions. Enhancement N/A Dependencies N/A 1.7 Alarm Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Summary Feature No. Feature Name One Key-070101 Startup failure One Key-070102 Overvoltage One Key-070103 Bus undervoltage One Key-070104 Bus voltage imbalance One Key-070105 Inverter soft startup failure One Key-070106 Inverter overvoltage One Key-070107 Inverter undervoltage One Key-070108 Inverter output short circuit One Key-07019 Battery overvoltage Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 12 UPS2000 Feature Description 1 Basic Features Feature No. Feature Name One Key-070110 Battery undervoltage One Key-070111 Overtemperature One Key-070112 Overload One Key-070113 Charger fault One Key-070114 Insufficient battery capacity One Key-070115 Bypass mode One Key-070116 Error Benefits Feature Name Benefits Startup failure Monitors the UPS and reports alarms in real time. Overvoltage Monitors the UPS and reports alarms in real time. Bus undervoltage Monitors the UPS and reports alarms in real time. Bus voltage imbalance Monitors the UPS and reports alarms in real time. Inverter soft startup failure Monitors the UPS and reports alarms in real time. Inverter overvoltage Monitors the UPS and reports alarms in real time. Inverter undervoltage Monitors the UPS and reports alarms in real time. Inverter output short circuit Monitors the UPS and reports alarms in real time. Battery overvoltage Monitors the UPS and reports alarms in real time. Battery undervoltage Monitors the UPS and reports alarms in real time. Overtemperature Monitors the UPS and reports alarms in real time. Overload Monitors the UPS and reports alarms in real time. Charger fault Monitors the UPS and reports alarms in real time. Insufficient battery capacity Monitors the UPS and reports alarms in real time. Bypass mode Monitors the UPS and reports alarms in real time. Error Monitors the UPS and reports alarms in real time. Startup failure Monitors the UPS and reports alarms in real time. Overvoltage Monitors the UPS and reports alarms in real time. Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 13 UPS2000 Feature Description 1 Basic Features Description Feature Name Description Startup failure Reports alarms when the mains soft startup or inverter soft startup fails. Overvoltage Reports alarms when the mains input voltage is higher than the normal range. Bus undervoltage Reports alarms when the bus voltage is lower than the normal range. Bus voltage imbalance Reports alarms when the bus voltage is unbalanced. Inverter soft startup failure Reports alarms when the inverter fails to start properly. Inverter overvoltage Reports alarms when the inverter output voltage exceeds the upper threshold. Inverter undervoltage Reports alarms when the inverter output voltage is lower than the lower threshold. Inverter output short circuit Reports alarms when an Inverter output short circuit occurs. Battery overvoltage Reports alarms when the battery voltage exceeds the upper threshold. Battery undervoltage Reports alarms when the battery voltage is lower than the lower threshold. Overtemperature Reports alarms when the UPS is experiencing a high temperature. Overload Reports alarms when the UPS is overloaded. Charger fault Reports alarms when the charger is faulty. Insufficient battery capacity Reports alarms when the battery capacity is insufficient. Bypass mode The buzzer alarm buzzes when the UPS enters the bypass mode. Error Reports alarms when the UPS is experiencing an error. Enhancement N/A Dependencies N/A Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 14 UPS2000 Feature Description 2 Optional Features 2 Optional Features 2.1 Environmental Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Summary Feature No. Feature Name One Key -080101 EMD optional component (ambient temperature and humidity sensor with two dry contact inputs) Benefits Feature Name Benefits EMD optional component (ambient temperature and humidity sensor with two dry contact inputs) Monitors the ambient temperature and humidity of the UPS to ensure that it works in a normal condition. Description Feature Name Description EMD optional component (ambient temperature and humidity sensor with two dry contact inputs) The EMD optional component ensures that the UPS system works at proper temperature and humidity. Enhancement N/A Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 15 UPS2000 Feature Description 2 Optional Features Dependencies N/A 2.2 Power Distribution Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Summary Feature No. Feature Name One Key -090102 AC power cable Benefits Feature Name Benefits AC power cable Provides input and output cables that support various input systems. Feature Name Description AC power cable AC power cable (250 V 16 A) applicable in the UK: black, 3-meter long, and C19SF Description Enhancement N/A Dependencies N/A 2.3 Battery Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 16 UPS2000 Feature Description 2 Optional Features Summary Feature No. Feature Name One Key-110101 Standard external battery box, which can be expanded in parallel. One Key-110102 External battery rack One Key-110103 External battery charger Benefits Feature Name Benefits Standard external battery box, which can be expanded in parallel. Provides battery cabinets for lead-acid batteries with a capacity less than 9 Ah. External battery rack Provides battery racks for lead-acid batteries with a capacity more than 26 Ah. External battery charger Provides large charging currents to fast charge the UPS with an extended backup time and reduce power failures. Description Feature Name Description Standard external battery box, which can be expanded in parallel. Provides battery cabinets for lead-acid batteries with a capacity less than 9 Ah. External battery rack Provides battery racks for lead-acid batteries with a capacity more than 26 Ah. External battery charger A 10 A large-current charger rapidly charges the large-capacity batteries. Enhancement N/A Dependencies N/A Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 17 UPS2000 Feature Description 2 Optional Features 2.4 Monitoring Features Availability This feature is introduced to UPS2000 V200R001 and later versions. Summary Feature No. Feature Name One Key-120101 SNMP card One Key-120102 Modbus card One Key-120103 Dry contact output card One Key-120104 Network management software Benefits Feature Name Benefits SNMP card Monitors and manages the UPS remotely. Modbus card Used for the building management system (BMS). Dry contact output card Manages and reports UPS status. Network management software Monitors the system on the WebUI. Description Feature Name Description SNMP card The SNMP card implements web monitoring over TCP/IP, supports remote control, and provides extended network ports. Modbus card The Modbus card obtains converted data over Ethernet port, transparently transmits data between the communication ports, such as RS232 to RS485, or TCPIC to RS485, and supports other transmission mode in various application scenarios. Users develop the interface by using configuration software or software provided by Huawei and monitor the system online and remotely over Modbus TCP. Dry contact output card The dry contact output card shuts down the UPS remotely or reports the USP battery status, bypass status, and faults. Network management software The network management software Monitors the system on the WebUI. Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 18 UPS2000 Feature Description 2 Optional Features Enhancement N/A Dependencies N/A Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 19 UPS2000 Feature Description A Acronyms and Abbreviations A Acronyms and Abbreviations Table 2-1 Acronyms and Abbreviations Acronym or Abbreviation Full Name IEC International Electrotechnical Commission CE Conformité Européenne TUV Technical Inspection Association ROHS Restriction of hazardous substances THDi Total harmonic distortion of current ECO Economic UPS Uninterruptible power supply PDU Power distribution unit STS Static transfer switch SNMP Simple network management protocol Issue V1.0 (2014-06-28) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 20