* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Solid Solutions in a Fluid Environment
Survey
Document related concepts
Transcript
DTS Fluid Power Solid Solutions in a Fluid Environment FLUID POWER COMPONENTS • Auburn Planetary Gear Drives • Char-Lynn Motors •Eaton • Goodyear Hoses •Vickers DTS Fluid Power Your Single Source for Fluid Power We make it our job to understand the fluid power intricacies for your industry. We provide technological solutions and world class products to keep your production running efficiently and cost effectively. From complete power units, hydraulic and electrical components to certified fluid power specialists and repair services, DTS Fluid Power is your single source for your fluid power components and services. DTS Fluid Power was founded in 1979 as Hickmann Fluid Power and changed its name to DTS Fluid Power in 1991. It became a valued supplier of hydraulic components to Original Equipments Manufacturers (OEM) in the Michigan market. It is the leading mobile OEM supplier for fluid power products and has a team of skilled engineers to design your mobile equipment, industrials circuits or refurbishment projects. DTS Fluid Power is a subsidiary of Applied Industrial Technologies, a $2.0 billion MRO provider and resource for product technologies such as fluid power, power transmission, bearings, industrial rubber products, linear technologies and maintenance supplies. Our customers have access to local expertise and the benefits of more than 400 Applied locations in North America working together to get you the parts you need. The Leader in Engineered Hydraulic Systems to the Mobile OEM Marketplace. Accumulators Gauges Planetary Gear Drives Oil Air Tobul Pressure Devices Lenz Stauff Auburn Gear Durst-Terrel Heco Gear Box Power Unit-Systems Hub City DTS Products Delta Fenner-SPX Vickers Brakes and Clutches Mico Coolers Thermal Dynamics AKG Couplings LoveJoy Hayes Cylinders Eaton Cross Energy Yates Custom DTS Prince Electronic Controls Eaton EFX Kar-Tech Omnex NBB Controls Filters Vickers Schroeder Industries Zinga Fittings Brennan Anchor Dixon Flow Dividers – Gear Casappa Delta Flow Meters Hedland Webster Instruments General Hose & Accessories Goodyear Engineered Products Parker Dixon Reel Craft Hose, Hose Ends & Equipment Goodyear Engineered Products Parker/Dayco “Ultra Clean” Hose Cleaning System Industrial Hose Goodyear Engineered Products Hose Master “Stainless Hose” Parker Lubrication Systems Dropsa Motors Eaton Casappa Voac Cross Char-Lynn Poclain Delta Eaton Linde Prince Vickers Over Hung Load Adapters Helland-Zero-Max Pipe Clamping Dixon Hydrazorb-Unitrol Stauff Pumps Eaton/Vickers Casappa Voac/Parker Prince Linde Quick Disconnect Safeway Tank & Hydraulic Accessories Lenz Lube Devices Nason Stauff Vescor Zinga Valves Vickers Husco Walvoil Modular Controls Aron Brand Hydraulics Cross Northman Dixon Energy Rub Vonberg Parker Winches RKI Formulas CYLINDERS HYDRAULIC PUMPS & MOTORS CYL AREA = DIAMETER x .7854 (IN ) Annulus Area or EREA = CYL AREA – ROD AREA (IN2) CYL FORCE = PRESSURE x AREA (LBS) ADJ. GPM ON RET = CYL AREA x GPM EREA ACTUAL TORQUE = THEO TORQUE x MECH. EFF. 100 HP OUT = HP IN x OVERALL EFF. 100 CYL TIME (SEC) = AREA x STROKE x .26 GPM CYL SPEED (FT/MIN) = STROKE x 5 TIME(SEC) ACTUAL MOTOR RPM = THEO RPM x VOL. EFF. 100 TORQUE (IN-LBS) = PSI x DISP (IN3) 6.28 CYL SPEED (FT/MIN) = GPM x 19.25 AREA CYL HP = CYL SPEED x CYL FORCE 33,000 OVERALL EFF. = MECH. EFF. X VOL. EFF. 100 TORQUE (IN-LBS) = HP x 63025 RPM TUBE AREA (IN2) = GPM x .3208 OIL VELOCITY HYD HP = PSI x GPM 1714 2 2 ACTUAL PUMP = THEO GPM x VOL. EFF. 100 GPM VEHICLE SIZING FORMULAS RPM = MPH x 168 LR PNEUMATICS P1V1T2 = P2V2T1 (Use Absolute Values) GPM = RPM x DISP (IN3) 231 COMP CFM = AREA x STROKE TIME (SEC) x 28.8 PNEUMATIC HP = COMPRESSED CFM x PSI 229 LR = LOADED RADIUS TE = TRACTIVE EFFORT WD = WEIGHT ON DRIVE WHEELS ADC = ADHESION COEFFICIENT RR = ROLLING RESISTANCE GR = GRADE RESISTANCE DP = DRAW BAR PULL TORQ = TE x LR WHEEL SLIP = WD x ADC x LR TORQ TE = RR + GR + DP OTHER FLUID POWER FORMULAS VELOCITY (Ft./Sec.) = GPM .3208 Inside d2 (.7854) (Surface Area Ft.2) x T∆ (Temp. Diff in °F between oil and surrounding air) AREA OF CIRCLE = D2 .7854 BURST PRESSURE OF PIPE = 2T (Wall Thick In.) x (Tensile of Mat. PSI) OR TUBING (PSI) O.D. (Outside Dia. In. CIRCUMFERENCE = dπ One Watt will raise the temperature of 1 gal. of oil by 1 °F per hour. BTU/HR. = PSI x 1-1/2 Pipe Schedule 80 Grad C @ 200°F: H.P. = PSI x GPM x .00058 Size 3/8 3/4 1 1-1/4 1-1/2 2 3 4 6 1 CU. IN. = 16.39C C = (°F – 32) 1.8 F = (°C x 9/5) + 32 H.P. (RADIATING CAPACITY) = .001 x A Pipe(In.) Wall .126 .154 .179 .191 .200 .218 .300 .337 .432 PSI 3800 3850 3860 3330 3100 .2770 2840 2540 2300 10 Ft/Sec GPM 4 14 22 40 55 91 206 365 813 15 Ft/Sec GPM 5 20 33 60 83 138 310 548 1220 Note: Above ratings are approximate Headquarters 3560 Busch Drive Grandville, MI 49418 PH: 616.538.3759 FAX: 616.538.3798 Illinois 2240 Landmier Road Elk Grove, IL 60007 PH: 847.758.1705 FAX: 847.758.1710 Michigan 31731 Sherman Dr Madison Heights, MI 48071 PH: 248.585.9500 FAX: 248.585.0855 A subsidiary of: WARNING: Injury, death, property damage, and/or equipment failure may result from the misuse or misapplication of the products featured in this publication. The information in this publication is provided “AS IS,” WITHOUT any WARRANTY OF THE INFORMATION’S ACCURACY OR THE PRODUCTS’ SUITABILITY FOR ANY PARTICULAR USE. © 2008 Applied Industrial Technologies, Inc. All Rights Reserved. C-1008-0920-4903 Corporate Headquarters 1 Applied Plaza Cleveland, Ohio 44115 Toll Free Phone: 1-877-279-2799 Applied.com