Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Index of electronics articles wikipedia , lookup
Power MOSFET wikipedia , lookup
Opto-isolator wikipedia , lookup
Integrating ADC wikipedia , lookup
Coupon-eligible converter box wikipedia , lookup
Current mirror wikipedia , lookup
Surge protector wikipedia , lookup
Television standards conversion wikipedia , lookup
Power electronics wikipedia , lookup
DCS800-E DC Drive Panel Solution 20...450 A DC PRE-MOUNTED PRE-ENGINEERD FAST INSTALLATION DIN EN ISO 9001 DIN EN ISO 14001 Standard Features • All necessary components installed • Easy installation: 'Ready for use' • Very short installation time • Reduces power-down-time in rebuilding projects to a minimum The DCS800-E Panel Solution The DCS800-E is a compact user-friendly Panel-Solution. It offers all needed components pre-mounted, fully wired and factory-tested. While mounting it into an empty cabinet the mechanical installation will be completed. This ready-to-use concept allows to squeeze the power-down-time in rebuilding projects to a minimum. The DCS800-E aims for revamping projects to replace old DC-Drives up to 450 A, where the most economic solution is to replace the whole drive including thyristor stack and field exciter. When re-using the power part in bigger-sized DCDrives please take our special Rebuild Kits in consideration, that are tailor made for special ancient converters (e.g. TYRAK8 Rebuild Kit for old ASEA TYRAK Series) and offer modern digital control and auxiliary electronics, while the thyristor stack and other powerparts can be re-used. Features DCS800-E mounted in old cabinet Main contactor DC fuses * Aux. transformer • Output currents from 25 to 450 A DC. • AC input voltage from 400, 525 to 600 V AC. • AC-Connection from top. Bottom-Connection can also be realized. • DC-connection from bottom of DCS-Module or from DC-fuses if ordered. • Pre-wired DC-Terminals at very bottom of DCSPanel as option for re-using existing motor cables. • DCS is fully tested with DC-motor acc. DCS800-E Enclosed Converters Test Specification. • Special solutions for Pulp&Paper (incl. Safety relay) available. • The DCS800-E is available in different types: - DCS800-E Standard - for standard applications with DCS800 converter modules. - DCS800-E Pulp and Paper - with safety relay for P&P-Applications. For every type a wide range of options is offered. DC output terminals * * as option DCS800-E bottom view User Benefits • Cost-Saving by reusing long-life components, like cabinet, power cables or busbars, incoming disconnector and line fuses and other power parts. • Digital technology with up-to-date communication interfaces and control performance offers increased process availability, quality and productivity. • Pre-engineered standard solution requires only a minimum of engineering time. • Pre-mounted components on a ready-to-connect panel offer reduced installation time. • System shut down time can be squeezed to a minimum. • Additional tools for simple assembly on site. DCS800-E top view DCS800-E side view Layout 5 20 51 3 DCS800-E consists of 3 separate units: • Power unit - Includes all power devices. • Aux unit - Includes all auxiliary devices - Can be mounted either on the left or on the right side of the power unit. • I/O unit - For IOB-2/3 and terminals. 5 19 1600 • All three units are fixed together to be mounted as one single unit. • They may also be mounted separately in different places for space saving and small cabinets. Mounting A mounting kit is available for Standard TYRAK 8/L cabinets (Types YxMK, YxML, YxMp). It consists of an upper and lower mounting support, that are screwed to the cabinet for easy fixing of the panel, and two sliding rails for easily sliding the whole DCS800-E-Panel into the cabinet. The Sliding Rails may be removed and re-used after the installation. Mounting kits for other types of cabinets on request. 51 5 DCS800-E draw_3d.dsf DCS800-E mounting supports With total dimensions of WxDxH=515x515x1600 mm the DCS800-E Panel can be used for most cabinets with a footprint of 600x600 mm. Sliding rails in cabinet bottom Load cycles DCS800-E Panel Solution unit types Unit type DC I ➀ [A] 400 V / 525 V DCS800-E01-0020-04/05-960t DCS800-E02-0025-04/05-960t DCS800-E01-0045-04/05-960t DCS800-E02-0050-04/05-960t DCS800-E01-0065-04/05-960t DCS800-E02-0075-04/05-960t DCS800-E01-0090-04/05-960t DCS800-E02-0100-04/05-960t DCS800-E01-0125-04/05-960t DCS800-E02-0140-04/05-960t DCS800-E01-0180-04/05-960t DCS800-E02-0200-04/05-960t DCS800-E01-0230-04/05-960t DCS800-E02-0260-04/05-960t DCS800-E01-0315-04/05-960t DCS800-E02-0350-04/05-960t DCS800-E01-0405-04/05-960t DCS800-E02-0450-04/05-960t DCS800-E01-0470-04/05-960t DCS800-E02-0520-04/05-960t 600 V DCS800-E01-0290-06-960t DCS800-E02-0320-06-960t DC II current 100 % 150 % 15 min 60 sec. [A] [A] DC III current 100 % 150 % 15 min 120 sec. [A] [A] DC IV current 100 % 200 % 15 min 10 sec. [A] [A] Field current Power loss [A] [kW] ➁ DC I ➀ IDC I continuous IDCI 100% 18 22 41 45 61 67 81 90 115 125 160 180 210 225 285 300 365 405 400 450 17 21 36 40 47 53 55 64 87 95 119 134 150 159 219 228 285 316 308 345 27 32 55 59 73 80 70 96 130 142 180 201 225 239 329 342 428 475 462 517 16 20 33 37 44 50 41 62 83 91 118 131 141 150 211 222 275 306 290 330 26 31 51 56 68 75 66 93 123 136 178 197 212 225 316 333 413 459 435 495 14 18 32 36 44 50 41 61 83 91 99 111 124 132 192 200 254 283 275 308 30 35 68 72 93 100 91 122 166 186 198 223 248 264 384 400 509 567 550 616 6 6 6 6 6 6 6 6 6 6 15 15 15 15 20 20 20 20 20 20 <0.58 <0.58 <0.65 <0.65 <0.72 <0.72 <1.00 <1.00 <1.00 <1.00 <1.51 <1.51 <1.51 <1.51 <1.89 <1.89 <2.47 <2.47 <2.57 <2.57 260 285 214 235 300 330 192 211 268 294 192 210 344 377 DCF503 DCF503 <1.85 <1.85 t DC II 15 min Voltage class: (example: DCS800-E02-0025-04-960t) 4 ⇒ 400V 5 ⇒ 525V 6 ⇒ 600V ➀ = Given Ratings are typical values for mounting in IP 21 cabinets; actual values may differ and are strongly depending on the cabinet and its cooling, especially with higher protection classes ➁ = Values are valid for Standard Scope of delivery without options 100% 150% DC III IDC III for 15 min 15 min 150% DC IV Table 1: DCS800-E types t=1 ⇒ Standard type t=2 ⇒ P&P type IDC II for 15 min and 100% IDC IV for 15 min IDCIV 15 min 200% 100% t DCS 8 Aux. Transformer T2 incl. F2 and MCB F5 on secondary side Fusing of Auxiliary Circuits with MCBs Single Wires are tinned Complete set of drawings in a binder Control panel DCS800-PAN Field Exciter Circuit 6/15/20 A X X X X X X X X X X • X X X • X X X X X X X X X X X X X X • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Remarks Standard Scope of Delivery DCS800 module Main Contactor K1 Standard Fuseholder incl. Semiconductor Fuses F1 Power unit has Protection Class IPauc AC-connection at top of F1, DC-connection at DCS-Module bottom (if DC-Fuses are selected, DC-connection is at botton of DC-fuses) Auxiliary Devices Digital I/O-board IOB-2x Converter Fan contactor K8 EStop Time Relay K15 Safety Relais A04 acc. to P&P Standard DCS 8 00-E 0 00-E 0 x (S t d) x (P & P) Scope of delivery and options DCS800-S01/S02-0025...0520 (Design current 22-450A DC) Fuseholder incl. Disconnecting device as option as standard for 1.5m long pre-mounted AC- and DC-cables check options not possible, when 2nd Fex is installed (shared Motion) T2 primary side not connected to incoming AC-Supply, but to terminals. Connection to be done by user. as standard as standard as standard mounted on converter module for 400 V and 525 V types Options (price see pricelist) Mounting Kit For light Industrial Environment depending on line and field voltage replaces Standard Fuseholder incl. K6, F6, F60 not possible, when 2nd Fex is installed (shared Motion) also necessary for Residual Current Detection inside converter module inside converter module incl. K11+K12 inside converter module inside converter module loose delivery, free of use can be used for encoder, IOB-2x, IOB-3 for RDIO RAIO suitable for TYRAK8 types 3 pc. AC-cables connected to the AC-fuseholder plus 2 pc DC output terminals at the very bottom of the power unit 2 Mounting Supports to be screwed into the old cabinet plus 2 rails for sliding the Kit easily into the cabinet, to be removed after mounting. Details see mounting instruction. • • • 3ADW 000 210 R0101 REV A 02_2006 Power Devices Line Chokes L1 Type NDxx uk=1% Field Transformer T3 Fuseholder incl. Disconnecting Function (F1) Motor Fan Supply for Motor Currents/A (please specify when ordering): 0.4-0.63; 0.63-1; 1-1.5; 1.5-1.7; 1.7-2.3; 2.3-3; 3-3.8; 3.8-4.8; 4.8-6.3; 6.3-8 DC-Fuse-Holder and DC-Fuses for Armature Circuit I/O Options Analogue I/O-Board IOB-3 RDIO Digital extension board RAIO Analogue extension board 24V Supply 2A Local I/O Control with latching function Electrical Disconnect K16 Aux Control Voltage 115V (IOB-22) Fieldbusadapter DDCS Communication board Other Options Coated Boards Cable Marking A2 plus Prepared for UL certification (Cabling and Aux-Fuses) Door Mounting Kit for Panel DCS800-PAN 2 pc cable W0205 + W0206, each 7x1mm², 4m Spare cable 4*2*0.5, 4m long Isolation switch replacement kit AC and DC Connection cables ABB Automation Products 68526 Ladenburg • GERMANY Phone +49(0) 62 03 71-0 Fax +49(0) 62 03 71-76 09 www.abb.com/motors&drives e-mail: [email protected] *210R0101A6080000* *210R0101A6080000* K11 K12 X7:18 1 X3: 2 AITAC _ + AI2 _ + AI3 _ + 4 5 6 7 8 if there are intermediate terminals 3 9 AI4 _ A10 SDCS-IOB-3 AI1 _ + Slot 3 Slot 2 K15 K16 X7:14 ELECTR. DISCONNECT 4x DDCS interface X33 X34 K15 Slot 1 E-STOP R-Fieldbus adapter K12 X7:12 X7:13 X7:10 X7:9 X7:11 + DC800-E0x...9601 (Standard) 10 residual current detection 11 Field X4: 3x Analogue Output 1.5/5mA current source 12 ±10V voltage source Burden resistor 100 Converter fan Motor fan K3 DO2 K10 DO3 (K10) DO8 X96: 1 K1 Mains contactor (DO3) F5 2 K8 X6: 1 A9 K6 2 K1 3 5 6 7 K16 X7:12 K11 4 SDCS-IOB-2x K15 X7:9 K12 8 2 1 2 DO2 DO3 DO4 5 1 11 10 9 8 7 6 5 4 3 2 5 6 5 6 M ~ 2 1 X2: 1 K8 690V 660V 600V 575V 525V 500V 450V 415V 400V 380V 3 4 1 3 2 4 1 2 V M 3~ U 2 4 3 F2 DO5 DO6 DO7 DO8 K1 (K10) Field Mains contactor K3 _ T + the polarities are shown for motoring Fans K6 K8 T 3 option depending on the unit type X2: 4 14 115V 13 T2 F6 K6 230V 12 F60 W X4: 1 2 3 4 5 6 7 8 X5: 1 2 3 4 5 6 7 8 DO1 Power supply (PIN-4) X99: 1 Interface to ext. UPS K16 / K15 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 COM Control board (CON-4) K8 X2:4 Fan X2:5 Klixon K6 F60 DO1 Reset DCS800-PAN Panel PC K11 X7:15 START ON K1 X7:17 STOP X7:16 X7:14 OFF X7:13 Circuit diagram wiring by customer X5:1...10 depending on converter size X7:1/X7:2 Motor fan starter L1 1 V1 4 3 5 W1 PE 6 Converter module DCS800 U1 2 L3 + C1 M D1 _ depending on converter type the wiring and the components F1, K1, L1 are different K1 Fuse switch F1 L2 Main supply L1 + X1: 5 3 _ Field exciter unit (PIN-4) L3 K3 F3 3 4 6 5 L13 _ DCS800-E_ans a.dsf + DCF 503-0035 2 1 L11 L12 option for 600 V included for 400 V and 525 V DCS800-PAN Panel PC Safety circuit Safety A04 relay Circuit diagram Status display K11 1 X3: 2 AITAC _ + 4 AI3 _ + 5 6 7 8 9 AI4 _ SDCS-IOB-3 AI2 _ + Slot 2 E-STOP MONITOR K15 if there are intermediate terminals 3 A10 AI1 _ + Slot 3 X33 X34 Slot 1 K11 4x DDCS interface R-Fieldbus adapter DI7 A04 DO4 + 10 residual current detection 11 Field K3 DO2 K10 DO3 (K10) DO8 X96: 1 K1 Mains contactor (DO3) K15 2 K8 X6: 1 A9 K6 2 K1 3 4 5 6 SDCS-IOB-2x 7 8 2 1 2 DO2 DO3 DO4 5 1 11 10 9 8 7 6 5 4 3 2 1 5 6 5 6 M ~ 2 1 X2: 1 K8 690V 660V 600V 575V 525V 500V 450V 415V 400V 380V 3 3 4 1 4 2 2 V M 3~ U 2 4 3 F2 DO5 DO6 DO7 DO8 K1 K15 (K10) E-Stop monitor Field Mains contactor K3 Prev. of Start E-STOP _ T + the polarities are shown for motoring Fans K6 K8 T 3 option depending on the unit type X2: 4 14 115V 13 T2 F6 K6 230V 12 F60 W X4: 1 2 3 4 5 6 7 8 X5: 1 2 3 4 5 6 7 8 DO1 Power supply (PIN-4) X99: 1 Interface to ext. UPS F5 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 COM Control board (CON-4) Converter fan K8 X2:4 Fan Klixon X2:5 X4: 3x Analogue Output 1.5/5mA current source 12 ±10V voltage source Burden resistor 100 Motor fan K6 F60 DO1 DCS800-E0x...9602 (DCS800-E P&P) depending on converter size X5:1...10 Safety relay A04 X7:1/X7:2 Motor fan starter L1 V1 4 3 W1 PE 6 5 Converter module DCS800 U1 2 1 L3 + C1 M D1 _ depending on converter type the wiring and the components F1, K1, L1 are different K1 Fuse switch F1 L2 Main supply L1 + X1: 5 3 _ Field exciter unit (PIN-4) L3 K3 F3 4 3 L12 6 5 L13 _ DCS800-E_ans P&P a.dsf + DCF 503-0035 2 1 L11 option for 600 V included for 400 V and 525 V