LSC-7D
Lightning Strike Counter
Installation Instruction
Installation
Lightning Protection
Part of THE ALLTEC
®
PROTECTION PYRAMID
L E V E L : Lightning Protection
F U N C T I O N : Monitoring Lightning
Strikes assists in determining the need for
additional security such as grounding, surge
suppression and lightning protection.
The LSC-7D connections should be electrically attached
to the tower using 14 AWG (2.5mm2) insulated wire and
be separated by approximately 8.0 ft (2.4m). The inductive
voltage drop due to a lightning strike will actuate the counter.
A log should be kept to record the date and counter reading.
To test your counter, voltage may be momentarily applied
using a 9V battery in either polarity to actuate the circuit.
The LSC-7D requires a 0.5 μH inductance shunt
(approximately 8.0 ft conductor length) to count nature’s
smallest lightning strike (3 kA). This inductance can be in the
form of a wire length, tower, or pipe segment. To calculate,
use the following approximations:
• 0.3 μH per foot per wire
• 0.067 μH per foot for triangular tower leg
• 0.150 μH per foot for >/= 6” pipe
BENEFITS:
The LSC-7D connection must be in direct contact with the
metallic wire or metallic structure being monitored. Clean,
sand, or pierce as required.
No Maintenance: Requiring no external
power supply or internal battery for
operation.
NOTE: No user serviceable parts inside. Do not loosen
sealing nuts.
Sealing nuts adjacent to enclosure
(Do not loosen)
Easy to Install: Uses a 2-wire connection
to any metal conductor for lightning voltage
detection, conductor dimensions are
unimportant.
DCounte
m
CS-t7
rike bal.co
LnS
glo
ing
tec
A
LS
r
M
IN
ht
N
TE
R
Lig
w
SA
U
E IN
D
MA
C
O
N
N
EC
TI
O
Easy to Monitor: Easily viewable from the
front.
.all
ww
Weather Resistant: Includes a NEMA 4X/
IP66, UV stabilized polycarbonate enclosure
with surface mount flanges, UL94V-0 flame
rated and suitable for either indoor or
outdoor installation.
Installation nuts & lock washers
Size
Width
Height
5.5 inch (139.7mm) 3.5 inch (88.9mm)
www.alltecglobal.com
Depth
1.5 inch (38.1mm)
LSC-7D
Lightning Strike Counter
Installation Instruction
Installation Examples
Building Model
Tower Model
Tower Clamp
Conductor Clamp
C O N N E C T I O N T E R M I N A LS
8.0 ft (2.4 m)
0000002
8.0 ft (2.4 m)
LSC-7D
Lightning Strike Counter
www.alltecglobal.com
MADE IN USA
LSC-7D Unit
Tower Clamp
Conductor Clamp
CONNECTION TERMINAL S
MADE IN USA
000002
LSC-6D
www.alltecglobal.com
Lightning Strike Counter
LSC-7D Unit
SOLUTION PROVIDERS FOR AN ENERGIZED WORLD™
WORLD HEADQUARTERS
64 Catalyst Drive, Canton, North Carolina 28716 USA
TEL: +1.828.646.9290 | FAX: +1.828.646.9527
EMAIL: [email protected]
ALLTEC has offices located across the world. Go to www.alltecglobal.com/contact
to connect with your regional office.
www.alltecglobal.com
© 2015 ALLTEC | 420-003 | 4/29/2015