* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 7 With the protective cover closed, it is not possible to set the
Immunity-aware programming wikipedia , lookup
Ground (electricity) wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Power factor wikipedia , lookup
Power over Ethernet wikipedia , lookup
Spectral density wikipedia , lookup
Wireless power transfer wikipedia , lookup
Electrical ballast wikipedia , lookup
Transformer wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Audio power wikipedia , lookup
Electrification wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electric power system wikipedia , lookup
Electrical substation wikipedia , lookup
Power inverter wikipedia , lookup
Power MOSFET wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage regulator wikipedia , lookup
Transformer types wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Three-phase electric power wikipedia , lookup
Stray voltage wikipedia , lookup
Power engineering wikipedia , lookup
Buck converter wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Surge protector wikipedia , lookup
Utility frequency wikipedia , lookup
Power electronics wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
E60254B E60253B View the settings and measurements Micro logic 5.0 b close the protective cover for the dials b access to the dials is blocked and it is no longer possible to make fine adjustments using the keypad Micro 7 logic logic 5.0 Micro E60490B With the protective cover closed, it is not possible to set the protection functions. However, it is possible to set metering functions and alarms, as well as view all measurements, settings and histories. 5.0 Micrologic P b if necessary, install a lead seal to protect the settings b settings may be viewed at any time using the keypad. Caution! If you notice that the tab on the back of the protective cover has been broken off, contact the Schneider after-sales support department to replace the cover. Schneider Electric Setting up the Micrologic control unit Setup Select the command Select. Select the command Power sign P+ P- By default, Micrologic P uses P+ for the power flowing from top to bottom terminals. The selected direction of flow is valid for: b measurement of power and the power factor b measurement of energy b load shedding and reconnection depending on power. P+ Confirm. Choose. VT ratio E71626A VT ratio E71625A Enter the voltage-transformation ratio E71624A Micrologic setup Power sign E71644B Power sign E71643B Select the sign of the power E71642B Micrologic setup Power sign VT ratio VT ratio Primary If the supply voltage for the control unit exceeds 690 V, an external voltage transformer must be installed. Primary Primary 690V 690V 690V Secondary Secondary Secondary 690V 690V 690V To display the true voltage values, enter the transformation ratio between the primary and secondary voltages of the transformer. Note that if Digipact display modules are used, the rated distribution-system voltage must be entered. then Select either the: b primary voltage b secondary voltage. Select the command Go on to the next setting. 400Hz If the phase-rotation protection function is activated, the 400 Hz frequency may not be selected. If the 400 Hz frequency is selected, the phase-rotation protection function is disabled. Select. 42 System frequency 50 - 60Hz Choose. Micrologic P E71629A System frequency E71628A Enter the rated frequency E71627A Micrologic setup System frequency then Enter the voltage. System frequency 50 - 60Hz Confirm. Schneider Electric