* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Low and Medium Voltage Circuit Breakers
History of electromagnetic theory wikipedia , lookup
Electric machine wikipedia , lookup
Induction motor wikipedia , lookup
History of electric power transmission wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Current source wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Flexible electronics wikipedia , lookup
Thermal runaway wikipedia , lookup
Surge protector wikipedia , lookup
Protective relay wikipedia , lookup
Regenerative circuit wikipedia , lookup
Electrical substation wikipedia , lookup
Rectiverter wikipedia , lookup
Fault tolerance wikipedia , lookup
Ground (electricity) wikipedia , lookup
Integrated circuit wikipedia , lookup
RLC circuit wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
Residual-current device wikipedia , lookup
Circuit Breaker Basics The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable. A MCCB provides protection by combining a temperature sensitive device with a current sensitive electromagnetic device. Both these devices act mechanically on the trip mechanism. Circuit Breaker Basics (cont.) Depending upon the application and required protection, a MCCB will use one or a combination of different trip elements that protect against the following conditions: Thermal overloads; Short circuits; and Ground faults. Thermal Overload Thermal overload: In an overload condition, there's a temperature buildup between the insulation and conductor. If left unchecked, the insulation's life will drastically reduce, ultimately resulting in a short circuit. Short Circuit Usually, a short circuit occurs when abnormally high currents flow as a result of the failure of an insulation system. This high current flow, termed short-circuit current, is limited only by the capabilities of the distribution system. To stop this current flow quickly so that major damage can be prevented, the short circuit or instantaneous element of an MCCB is used. Ground Fault A ground fault actually is a type of short circuit, only it's phase-to-ground, which probably is the most common type of fault on low-voltage systems (600V or less). Usually, arcing ground-fault currents are not large enough to be detected by the standard MCCB protective device. But, if left undetected, they can increase sufficiently to trip the standard protective device. Ground Fault (cont.) Prior to the introduction of electronic CBs, separate ground fault protection devices were used to provide this additional level of protection. Today's modern electronic CB has the ground fault protection as an integral part of the trip unit. Overload Trip Action Overload, or thermal trip action uses a piece of bimetal heated by the load current. This bimetal is actually two strips of metal bonded together, with each having a different thermal rate of heat expansion. They are factory-calibrated and not fieldadjustable. To trip the CB, this bimetal must deflect enough to physically push the trip bar and unlatch the contacts. Short Circuit Trip Action Uses an electromagnet having a winding that's in series with the load current. When a short circuit occurs, the current flowing through the circuit conductor causes the magnetic field strength of the electromagnet to increase rapidly and attract the armature. When this happens, the armature rotates the trip bar, causing the CB to trip. Short Circuit Trip Action The only time delay factor involves the time it takes for the contacts to physically open and extinguish the arc; this usually is less than one cycle. Magnetic elements are either fixed or adjustable, depending upon the type of CB and frame size. For example, most thermal magnetic breakers above the 150A frame size have adjustable magnetic trips. Circuit Breaker Ratings Arc Conditions The automatic operation of a circuit breaker occurs when there is an abnormal condition such as an overcurrent or short circuit. Overcurrent is electrical current in excess of the equipment limit, total amperage load of a circuit, or conductor or equipment rating. A short circuit is an unintentional connection of two ungrounded conductors that have a potential difference between them. Arc Interruption Arc Interruption Racking LVPCB Racking LVPCB Racking LVPCB http://www.youtube.com/watch?v=4bBvmPRqfmo Remote Racking https://www.youtube.com/watch?v=I4-rwcDbPcQ https://vimeo.com/156623494 https://www.youtube.com/watch?v=8sc8QDdnwb A https://www.youtube.com/watch?v=bVn8sl3AxRs DC Circuit Breaker DC circuit breakers work with the same principle of thermal protection and magnetic protection which is found in AC circuit breakers. Thermal protection trips: This protection mechanism is based on a bimetallic contact that heats, expands and trips the circuit breaker. Magnetic protection trips: This protection in a DC circuit breaker protects against short circuits and faults, which are drastically larger than an overload. DC Circuit Breaker A very important difference when interrupting alternating current and direct current is that the arc extinguishing point is higher for a DC circuit breaker. In direct current where voltage is continuous, the electric arc is constant and more resistant to interruption. For this reason, DC circuit breakers must include additional arc extinguishing measures: they typically have a mechanism to elongate and dissipate the electric arc in order to simplify interruption. DC Circuit Breaker DC Circuit Breaker