* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Diapositive 1 - Clinical Trial Results
Forensic epidemiology wikipedia , lookup
Start School Later movement wikipedia , lookup
Neonatal intensive care unit wikipedia , lookup
Fetal origins hypothesis wikipedia , lookup
Epidemiology of metabolic syndrome wikipedia , lookup
Preventive healthcare wikipedia , lookup
Adherence (medicine) wikipedia , lookup
Seven Countries Study wikipedia , lookup
Long-term care wikipedia , lookup
The Sleep Apnea cardioVascular Endpoints study (SAVE) R. Doug McEvoy Professor of Medicine, Adelaide Institute for Sleep Health Flinders University, AUSTRALIA [email protected] For the SAVE Investigators and Coordinators, on behalf of the SAVE Executive , Operations, and Advisory Committees Disclosures • Personal disclosure: Research funding - Philips Respironics, AirLiquide, ResMed and National Health and Medical Research Council (NHMRC) of Australia • Main funding for SAVE - Philips Respironics and NHMRC • Additional support - ResMed, Fisher&Paykel, Australasian Sleep Trials Network, Spanish Respiratory Society, and Fondo de Investigaciones Sanitarias Rationale – obstructive sleep apnea (OSA) • OSA causes repetitive night-time hypoxic episodes, sympathetic activation, BP surges, and cardiac stress • OSA associated with elevated BP, insulin resistance and endothelial dysfunction - improved by continuous positive airway pressure (CPAP) • OSA associated with an increased CV risk (stroke, coronary artery disease, heart failure) and sudden death (most at night) – reduced in observational studies with CPAP treatment • OSA affects 40-60% of CV patients • RCT clinical endpoint data lacking Objective • To determine if CPAP treatment of moderate to severe OSA in patients with CV disease would reduce the incidence of CV events Design • International, multicentre, prospective, open-label with blinded adjudication of endpoints, randomised controlled trial – CPAP + usual care – Usual care alone Patients Inclusion criteria Exclusion criteria • Age 45-75 years • Severe sleepiness or risk of fall-asleep accident • Coronary or cerebrovascular disease • Moderate-severe OSA – ApneaLink™, ResMed; 4% oxygen desaturation index, ODI, ≥ 12 events/hr1 • Able to use CPAP mask – Av. >3hrs/night during 1-week sham-CPAP run-in – Epworth sleepiness score >15; fall-asleep or near miss accident last 12 months; or commercial driver • Severe oxygen desaturation – >10% recording time with SaO2 <80% • Heart Failure NYHA Class III-IV • Cheyne Stokes respiration • Able and willing to give informed consent • Prior CPAP use 1. Ganter D et al. Respirology 2010;15:952-60 • Other condition which in opinion of investigator made patient unsuitable Outcomes • Primary outcome - composite of MI, stroke, hospitalisation for unstable angina, TIA or heart failure, and CV death • Secondary CV outcomes – Other composites: ischaemic CV events; major CV events; cardiac events; cerebral events – Individual components of primary outcome – New-onset atrial fibrillation, diabetes – All cause mortality Other outcomes • OSA symptoms - snoring, sleepiness (ESS), mood (HADS) • Health related quality of life (SF36) • Days off work due to sickness • Safety outcomes – Serious adverse events – Accidents causing personal injury, fall-asleep accidents or near miss accidents, traffic accidents Statistics Sample size - revised from 5,000 to 2,500 in 2012 – Challenges with recruitment - meta-regression showed strong relationship of AHI and CV events; blinded data of high event rates; good CPAP adherence – Power - 25% RR reduction for primary endpoint (α 0.05, 1-β 0.90) for av. 4.5 years FU; 6.86% annual event rate with usual care, av. CPAP 3 hr/night - for total of 533 events Statistics – ITT, P<0.047 for primary outcome (1 formal interim analysis) – Unadjusted survival analysis for time to first (adjudicated) event in Cox model – Sensitivity analyses - Covariate adjustments - stratification factors, region, severity of OSA; multiple events; events as clinician-reported – CPAP complier (>4 hrs/night) PP-matched Recruitment and Management Dec 2008 - Dec 2015 2717 patients from 89 centres in 7 countries International Coordinating Centre Core sleep laboratory Patient Flow 15,325 Screened 9481 Ineligible or declined 5844 ApneaLink sleep study 2598 Excluded 3246 Sham CPAP run-in 529 Excluded 2717 Randomised 1359 CPAP + Usual Care 1358 Usual Care 13 Withdrew consent or were excluded 17 Withdrew consent or were excluded 1346 included in ITT 1341 included in ITT Baseline Characteristics CPAP + usual care N=1346 Usual care N=1341 Age, mean, years 61 61 Male % 81 81 Ethnicity -Asian % 64 63 BMI, kg/m2 29 29 Snoring almost every day % 84 81 ODI 4% SaO2 dips/hr 28 28 AHI events/hr 29 30 Epworth sleepiness Score mean (0-24) 7.3 7.5 Baseline characteristics Coronary artery disease, % TIA/Stroke, % Systolic/ diastolic BP, mmHg Medical history, % Past or Current Smoking Hypertension Diabetes mellitus Medications, % BP lowering drugs, Lipid lowering drugs Antiplatelet/antithrombotic Oral anti-diabetic Insulin CPAP + Usual Care N=1346 Usual Care N=1341 51 49 132/ 80 51 49 131/ 79 57 79 30 55 78 29 78 60 75 22 6 78 60 75 22 6 CPAP adherence and OSA control Primary endpoint – neutral Hazard ratio (95% CI) 1.10 (0.91 - 1.32) Sensitivity and secondary CV analyses • No significant differences in primary outcome sensitivity analyses • No significant differences in analyses of: – Individual components of primary endpoint • Except rate of TIA hospital admissions higher in CPAP group, P=0.04 – Other CV composites – New-onset diabetes or newly diagnosed AF – All cause mortality Primary endpoint subgroups Sleepiness, mood, QoL, work and safety CPAP+Usual Care versus Usual Care • Improved – – – – Epworth sleepiness score (p<0.001) HADS anxiety (p=0.002) and depression (p<0.001) scores SF36 physical (p=0.002 ) and mental (p<0.001) component scores Work days lost because of ill-health (p<0.001) • No significant difference – Serious adverse events – Accidents Per protocol analysis CPAP good compliers (i.e. >4 hrs/night; n=561) matched 1:1 with usual care patients by propensity scores Composite primary outcome, no. (%) Components of primary endpoint CV Death Myocardial infarction Stroke Hospitalisation for heart failure Hospitalisation for unstable angina Hospitalisation for TIA Other vascular endpoints Composite of ischaemic CV events Composite of major CV events Composite for cerebral events Composite for cardiac events Hazard Ratio (95% CI) 0.80 (0.60 to 1.07) 0.13 0.90 (0.41 to 2.01) 1.19 (0.59 to 2.39) 0.56 (0.32 to 1.00) 0.81 0.63 0.05 0.82 (0.34 to 2.03) 0.99 (0.64 to 1.51) 0.22 (0.03 to 2.01) 0.67 0.95 0.18 0.81 (0.59 to 1.10) 0.69 (0.46 to 1.04) 0.52 (0.30 to 0.90) 1.01 (0.74 to 1.39) 0.17 0.08 0.02 0.93 P Conclusions • Addition of CPAP to usual care did not reduce CV events in patients with OSA and coronary or cerebrovascular disease – Risk of stroke may be reduced in patients with high levels of CPAP adherence • CPAP significantly improved daytime alertness, mood, quality of life, and reduced work-days lost because of ill-health McEvoy RD et al. NEJM 2016, 28 August [Epub ahead of print].