* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Electrical and mechanical accessories
History of telecommunication wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrical engineering wikipedia , lookup
Flexible electronics wikipedia , lookup
Electronic engineering wikipedia , lookup
Regenerative circuit wikipedia , lookup
Power electronics wikipedia , lookup
Automatic test equipment wikipedia , lookup
Power MOSFET wikipedia , lookup
Electrical connector wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
RLC circuit wikipedia , lookup
NEMA connector wikipedia , lookup
Integrated circuit wikipedia , lookup
Index of electronics articles wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Functions and characteristics Electrical and mechanical accessories 044313 Compact NS100 to 630 (cont.) Remote tripping MX or MN voltage release A-100 MX or MN voltage releases are used to trip the circuit breaker. MN undervoltage release This release trips the circuit breaker when the control voltage drops below a tripping threshold: b tripping threshold between 0.35 and 0.7 times the rated voltage b circuit breaker closing is possible if the voltage exceeds 0.85 times the rated voltage. For a lower value, circuit breaker closing cannot be guaranteed. Circuit breaker tripping by an MN release meets the requirements of standard IEC 60947-2. Time-delay unit for an MN release Eliminates nuisance tripping due to transient voltage dips lasting 200 ms. It is used in conjunction with: b a 250 V DC MN release, control voltage 220/240 V AC b a 48 V DC MN release, control voltage 48 V AC. MX shunt release Trips the circuit breaker when the control voltage rises above 0.7 x Un. Control signals can be of the impulse type (u 20 ms) or maintained. Operation When the circuit breaker has been tripped by an MN or MX release, it must be reset locally. MN or MX tripping takes priority over manual closing. In the presence of a standing trip order, closing of the contacts, even temporary, is not possible. Mechanical characteristics b endurance is equal to 50 % of the mechanical endurance of the circuit breaker b the releases clip in behind the front cover b connection using wires up to 1.5 mm2, to integrated terminal blocks. Electrical characteristics b consumption: v pick-up (MX): < 10 VA v seal-in (MN and MNR): < 5 VA. b response time: < 50 ms. 047313 Motor-mechanism module When equipped with a motor-mechanism module, Compact NS circuit breakers feature very high mechanical endurance as well as easy and sure operation: b all circuit-breaker indications and information remain visible and accessible, including trip-unit settings and indications b suitability for isolation is maintained and padlocking remains possible b double insulation of the front face. Applications b local motor-driven operation, centralised operation, automatic distribution control b normal/standby source changeover or switching to a replacement source to optimise energy costs b load shedding and reconnection to optimise energy costs b synchrocoupling. Automatic operation b circuit-breaker ON and OFF controlled by two impulse-type or maintained control signals b automatic spring charging following voluntary tripping (by MN or MX), with standard wiring b mandatory manual reset following tripping due to an electrical fault. Manual operation b transfer to manual mode using a switch (9) with possibility of remote mode indication b circuit-breaker ON and OFF controlled by 2 pushbuttons b recharging of stored-energy system by pumping the lever 9 times b padlocking in OFF position. Installation and connection All installation (fixed, plug-in/withdrawable) and connection possibilities are maintained. Motor-mechanism module connections are made behind its front cover to integrated terminals, for cables up to 2.5 mm2. Accessories b keylock for locking in OFF position b operations counter for the Compact NS400 and NS630, indicating the number of ON and OFF cycles. The counter must be installed on the front of the motormechanism module. Characteristics Compact NS250H with motor mechanism 2 3 4 5 6 E21006 1 compact 2 NS400 H Ui 750V. Uimp 8kV. Ue Icu (V) (kA) 100 70 65 50 20 220/240 380/415 440 500/525 600/690 cat A Ics = 100% Icu IEC 947-2 UTE VDE BS UNE NEMA O OFF charged CEI In = 400A manu 10 auto 9 O I push OFF push ON 8 1 7 Motor mechanism MT100 to MT630 Response time (ms) 1 2 3 4 5 contact position indicator (suitability for isolation) outgoing-circuit identification labels spring status indicator (charged, discharged) locking device (keylock) locking device (OFF position), using 1 to 3 padlocks, shackle diameter 5 to 8 mm, not supplied 6 manual spring-charging lever 7 I (ON) pushbutton 8 O (OFF) pushbutton 9 manual/auto mode selection switch. The position of this switch can be indicated remotely 10 operations counter (Compact NS400/630) opening closing cycles/minute max. DC Rate Control voltage (V) < 600 < 80 4 24/30 - 48/60 110/130 - 250 48 (50 Hz) - 110/130 220/240 - 380/440 y 500 y 500 y 500 y 500 AC 50/60 Hz Consumption (1) DC (W) AC (VA) opening closing opening closing E21300 Electrical endurance Circuit breaker + motor-mechanism module, in thousands of operations (IEC 60947-2), at 440 V. 50 40 30 NS100 20 NS160 15 10 NS250 6 NS400 4 NS630 0,1 0,2 0,3 0,5 0,7 1 I/In (1) For NS100/250, motor "vibratory" type consider inrush current as 2 In during 10 ms cycling. A-101 Functions and characteristics Electrical and mechanical accessories Compact NS100 to 630 (cont.) 048287 Indications and measurement Voltage presence indicator The indicator detects and indicates that circuit breaker terminals are supplied with power. Installation b in the long or short terminal shields, via the knockouts b not compatible with the motor-mechanism module b upstream or downstream of the circuit breaker b degree of protection IP40, IK04. Electrical characteristics Operates on all networks with voltages ranging from 220 to 550 V AC. Current-transformer module 041892 Compact NS630L with voltage-presence indicator This module enables direct connection of a measurement device such as an ammeter or a Digipact power meter (not supplied). Installation b directly on the downstream circuit-breaker terminals b degree of protection IP40, IK04 b class II insulation between front and the power circuits b connection to 6 integrated connectors for cables up to 2.5 mm2. Electrical characteristics b transformer with 5 A secondary winding. b accuracy class 3 for the following output-power consumptions: v rating 100 A: 1.6 VA v rating 150 A: 3 VA v rating 250 A: 5 VA v rating 400/630A: 8 VA. Current-transformer module with voltage measurement outputs 045212 Compact NS630H with current-transformer module For direct connection of a digital power monitoring unit: Power Meter PM700, PM800, etc. (not supplied). Installation b mounts directly on the downstream terminals of the circuit breaker b degree of protection: IP40 and IK04 b class II insulation of front with respect to the power circuits b built-in connectors for cables from 1.5 to 2.5 mm2. Electrical characteristics b rated operational voltage Ue: 530 V b frequencies of measured values: 50…60 Hz b three CTs with 5 A secondary windings for the rated primary current IN v class 0.5 to 1 for rated power consumption values at the output: - 125 A, 150 A and 250 A ratings: class 1 for 1.1 VA - 400/600 A rating: class 0.5 for 2 VA v use a cable of 2.5 mm2 section up to 2.5 m long. b four voltage measurement outputs including protection with automatic reset. v voltage measurement output impedance 3500 Ω ±25 %, maximum current 1 mA. Ammeter and Imax ammeter modules Compact NS250L with ammeter module A-102 Ammeter module Measures and displays (dial-type ammeter) the current of each phase (selection of phases by 3-position switch in front). Imax ammeter module Measures and displays (dial-type ammeter) the maximum current flowing in the middle phase. The Imax value can be reset on the front. Installation b identical for both types of ammeter module b directly on the downstream circuit-breaker terminals b ammeter clips into module in any of four 90° positions, i.e. can be installed of devices mounted both vertically and horizontally b degree of protection IP40, IK04 b class II insulation between front and the power circuits. Electrical characteristics b ammeter module: accuracy class 4.5 b Imax ammeter module: accuracy ±6 % v maximum currents are displayed only if they last at least 15 minutes. 041896 Insulation-monitoring module This module detects and indicates an insulation drop on a load circuit (TN-S or TT systems). Operation is identical to that of a Vigi module, but without circuit-breaker tripping. Indication by a red LED in front. An auxiliary contact may be installed for remote insulation-drop indications. Installation b directly on the downstream circuit-breaker terminals b degree of protection: IP40, IK04 b double insulation of the front face. Electrical characteristics b settings: 100, 200, 500 and 1000 mA b accuracy: -50 +0 % b time delay following drop: 5 to 10 seconds b AC-system voltage: 200 to 440 V AC and 440 to 550 V AC. Compact NS250H with insulation-monitoring module 053172 Communicating auxiliaries Communicating versions of the auxiliary contacts and the motor-mechanism module also exist for integration in a Digipact communications system. They simply replace the standard electrical auxiliaries. Using the STR53UE and STR43ME trip units equipped with the COM communications option, it is possible to transmit data to Digipact modules: b settings b rms values of phase and neutral currents b current of the most heavily loaded phase b overload alarm in progress b tripping cause (overload, short-circuit, etc.). 054481 Compact NS equipped with communicating auxiliary contacts and motor-mechanism module Withdrawable Compact NS equipped with communicating auxiliary contacts A-103 Electrical and mechanical accessories Functions and characteristics Compact NS100 to 630 (cont.) Locking systems Locking in the OFF position guarantees isolation as per IEC 60947-2. Padlocking systems can receive up to three padlocks with shackle diameters ranging from 5 to 8 mm (padlocks not supplied). Control device Toggle Direct rotary handle MCC rotary handle Rotary handle Extended rotary handle Means Required accessories lock in OFF position lock in OFF or ON position lock in OFF position padlock padlock removable device fixed device lock in OFF position lock in OFF position lock in OFF position, door opening prevented lock in OFF position, motor mechanism locked out padlock keylock padlock padlock keylock padlock keylock locking device + keylock keylock locking device (keylock incorporated) E18620 E58545 Motor mechanism E58544 Function ON I pr of al ux O OFF Locking of the toggle using a removable device A-104 Locking of the toggle using a fixed device Locking of the rotary handle using a padlock or a keylock. 048803 Individual enclosures Compact NS and Vigicompact NS devices with two, three or four poles may be installed in individual enclosures. All fixed, front connections are possible, except right-angle and edgewise terminal extensions. Spreaders may be installed in the enclosures intended for Interpact Compact and Vigicompact NS250 to 630 devices. There are two models of enclosures: b heavy-duty metal individual enclosure, with: v metal enclosure v door with keylock and cut-out for rotary handle v direct rotary handle (CNOMO, IP55, IK08) v device mounting plate v removable plate (without holes) for cable entry through bottom b heavy-duty insulating individual enclosure, with: v polyester insulating enclosure v transparent cover, screwed, lead sealable, with cut-out for rotary handle v extended rotary handle v device mounting plate v removable plates (without holes) for cable entry through bottom and/or top. Dimensions (H x W x D in mm) b metal enclosures: v Compact and Vigicompact NS100 to 160: 450 x 350 x 250 v Compact and Vigicompact NS250: 650 x 350 x 250 v Compact NS400: 650 x 350 x 250 v Compact NS630 and Vigicompact NS400 to 630: 850 x 350 x 250 b insulating enclosures: v Compact and Vigicompact NS100 to 160: 360 x 270 x 235 v Compact NS250: 540 x 270 x 235 v Compact NS400 to 630: 720 x 360 x 235 v Vigicompact NS250 to 630: 720 x 360 x 235 Heavy-duty insulating individual enclosure for Compact NS D E44458 W H A-105 Electrical and mechanical accessories Functions and characteristics Compact NS100 to 630 (cont.) E23938 E23936 E23935 Escutcheons are an optional feature mounted on the switchboard door. They increase the degree of protection to at least IP40, IK07. E21265 Escutcheons ON I push to trip Front-panel escutcheon for rotary handle. Secures to the panel by four screws, from the front. For circuit breaker with motor mechanism and Vigi module, use the protection collar for front panel mounting (see below). Toggle cover b degree of protection IP43, IK07 b fits on the front of the circuit breaker. E22039 Front-panel escutcheons for toggle and Vigi module (NSA160). Secures to the panel, from the front. 80 40 0 120 A Protection collars maintain the degree of protection, whatever the position of the device (connected, disconnected). b front-panel escutcheons are mandatory (same as those for rotary handles and ammeter modules) b collars are mounted on the device using two screws b escutcheons are attached to the switchboard b a toggle extension is supplied with the collar. For the insulation-monitoring module, use the same elements as for the Vigi module. Front-panel escutcheons for motor mechanism, rotary handles, ammeter modules Same as for fixed devices. A-106 E21267 Front-panel escutcheons for ammeter module. Secures to the panel by four screws, from the front. Protection collar for toggle and Vigi module on withdrawable devices O OFF Outgoing-circuit identification E18595 Compact NS100 to 630 devices come with clip-in labels for hand-written indications. It is also possible to use pre-printed Telemecanique labels part number AB1-**: v Compact NS100 to 250: 8 digits v Compact NS400 to 630: 16 digits. P D E P. P O M P. P DE O push to trip Identification accessories Sealing accessories E18596 This option includes the elements required to fit lead seals to prevent: b front removal b rotary-handle removal b opening of the motor-mechanism module b access to auxiliaries b access to trip-unit settings b trip-unit removal b access to earth-leakage protection settings b terminal-shield removal b access to power connections. Sealing accessories A-107 Electrical and mechanical accessories Functions and characteristics E59224 Compact NS630b to 1600 (fixed version) Sealable terminal shield Terminal extension for cables with lugs Interphase barriers Connection kit for connectors Vertical connection adapter Spreader Phase barriers Spreader Rear connectors Auxiliary contact Voltage release I on I O push push ON Manual control with front connection OFF arged disch O OFF d trippe reset F 0 OF I on 012 53 Manual control with rear connection d trippe Direct rotary handle reset F 0 OF Electrical control with mixed connection tripped reset Extended rotary handle Communications module Connection kit for connectors Sealable terminal shield Escutcheon A-108 E59225 Compact NS630 to 1600 (withdrawable version) Terminal extention for cables with lugs Interphase barriers Vertical connection adapter Spreader Rear connectors Spreader Auxiliary contact Voltage release Chassis with front or rear connection I on I O push push ON Manual operation OFF d trippe disch arged O OFF reset F 0 OF I on 012 d trippe 53 Direct rotary handle reset F 0 OF Electrical operation tripped reset Communications module Escutcheon Extended rotary handle Transparent cover A-109 Electrical and mechanical accessories Functions and characteristics Compact NS630b to 1600 DB112530 Installation Fixed configuration E59227A E59226A Compact NS630b to 1600 circuit breakers may be installed vertically, horizontally or flat on their back. E59278 Fixed Compact NS800H Mounting on a backplate Withdrawable configuration E59228A E59229A Compact NS630b to 1600 circuit breakers should be installed vertically only. E45176 The withdrawable configuration makes it possible to: b extract and/or rapidly replace the circuit breaker without having to touch connections; b allow for the addition of future circuits at a later date. Mounting on rails Rear mounting on rails E59231 E59230 Mounting on a backplate E59281A Withdrawable Compact NS800H Device on mounting plate A-110 Device on rails E59232A Connected Test Disconnected Removed The multifunctional chassis for Compact NS630b to 1600 devices is particularly suited for incoming circuit breakers. Features include: b device connection and disconnection through a door, using a crank that can be stored in the chassis b three positions (connected, test and disconnected) that are indicated: v locally by a position indicator v remotely by carriage switches (3 for the connected position, 2 for the disconnected position and 1 for the test position) b circuit-breaker ON/OFF commands through a switchboard front panel. Locking There are extensive locking possibilities: b chassis locking in connected, disconnected and test positions using three padlocks and two keylocks, on the switchboard front panel b door interlock (inhibits door opening with breaker in connected position) b racking interlock (inhibits racking with door open) b locking in each of the connected, disconnected and test positions during device connection or disconnection. Continuation to the next position requires pressing a release button to free the crank. Other safety function Mismatch protection ensures that a circuit breaker is installed only in a chassis with compatible characteristics. E59267A The device may be in one of four positions on the chassis: b connected position. The power circuits and auxiliary contacts are all connected b test position. The power circuits are disconnected. The auxiliary contacts are still connected and the device can be operated electrically b disconnected position. The power circuits and auxiliary contacts are all disconnected, however the device is still mounted on the chassis. It can be operated manually (ON, OFF, "push to trip"). b removed position. All circuits are disconnected. The device simply rests on the chassis rails and can be removed. 3 4 5 1 6 7 8 9 10 2 1 2 3 4 5 6 7 8 9 10 mismatch protection door interlock racking interlock keylock locking padlock locking position indicator chassis front plate (accessible with cubicle door closed) crank entry reset button crank storage A-111 Electrical and mechanical accessories Functions and characteristics Compact NS630b to 1600 (cont.) Types of connection Fixed device Front connections (N, H, L) Connection by: Rear connections (N, H, L, LB) DB112482 DB112484 DB112483 DB112485 cables with lugs + Connection by: bars cables with lugs DB112488 DB112481 Vertical: DB112487 DB112486 Horizontal: bare cables (except L) DB112484 DB112480 DB112481 bars Simply turn a horizontal rear connector 90° to make it a vertical connector. Combination of front and rear connections (N, H, L) Connection by: DB112484 DB112485 Withdrawable device Front connections Connection by: DB112484 cables with lugs DB112485 DB112481 DB112491 bars Rear connections DB112484 cables with lugs DB112488 DB112481 DB112492 + Connection by: bars A-112 cables with lugs DB112482 bare cables (except L) DB112483 DB112481 E59237 E59236 bars + To ensure performance and isolation, depending on the type of circuit breaker (N, H, L, LB) and type of connection, certain isolation accessories are mandatory. Connections accessories Type of accessories For Compact NS630b to NS1600 N, H, L, LB - - - - N, H, L, LB N, H, L, LB N, H, L, LB N, H, L, LB N, H, L, LB - N, H, L, LB N, H, L Set of bare-cable connectors and terminal shields for ratings y 1250 A N, H Cable lug adapters N, H, L Interphase barriers DB107661 DB107666 - Vertical-connection adapters DB107660 Withdrawable: Front connection Rear connection DB107667 Fixed: Front connection Rear connection DB107668 N, H, L Connection shield DB107662 N, H, L Safety shutters with locking by padlocks (IP20) DB107669 - DB107665 (1) (2) Spreaders N, H, L Arc chute screen (1) (1) N, H, L, LB N, H, L, LB N, H, L, LB - - - - N, H, L, LB (standard) N, H, L, LB (standard) - - - (1) (2) (1) Mandatory for voltages u 500 V unless using the bare-cable connector + terminal shield kit. (2) Mandatory for fixed devices with L and LB performance levels, whatever the voltage. A-113 Electrical and mechanical accessories Functions and characteristics Compact NS630b to 1600 (cont.) Fixed, front-connection Compact NS630b to 1600 devices are equipped with terminals comprising captive screws for direct connection of bars. Other connection possibilities for bars include vertical-connection adapters for edgewise bars and spreaders to increase the pole pitch to 95 mm. If the vertical connection adapters are front oriented, then it is mandatory to install the arc chute screen in order to comply with the safety clearances. E46426A Bars Vertical-connection adapters E59239A E59238A E46431A E59235 E54540 Front connection of fixed devices E70750 E59240A Spreaders. E59241A Special sets of connectors and terminal shields may be used to connect up to four 240 mm2 copper or aluminium cables for each phase. Bare cable connection is possible for ratings up to and including 1250 A. E46887A E54457 Bare cables 4-cable connectors Cable lug adapters E59243A E70751 E59242A Cable lug adapters are combined with the verticalconnection adapters. One to four cables with crimped lugs (y 300 mm2) may be connected. To ensure stability, spacers must be positioned between the terminal extensions. If the cable lug adapters are installed over the top of the arc chute chambers, then it is mandatory to install the arc chute screen in order to comply with the safety clearances. E46427A E54456 Cables with lugs A-114 Rear connection of fixed devices Spreaders. E59247A E59248A E59257A E59236 Fixed, rear-connection Compact NS630b to 1600 devices equipped with horizontal or vertical connectors may be directly connected to flat or edgewise bars, depending on the position of the connectors. Spreaders are available to increase the pole pitch to 95 mm. E46431A E54540 Bars Cable lug adapters enable connection of one to four cables with crimped lugs (y 300 mm2). To ensure stability, spacers must be positioned between the terminal extensions. E46427A E54456 Cables with lugs E59250A E59249A Cable lug adapters A-115 Electrical and mechanical accessories Functions and characteristics Compact NS630b to 1600 (cont.) Front connection of withdrawable devices Vertical-connection adapters E59253A E46431A E59252A E59280 Withdrawable, front-connection Compact NS630b to 1600 devices are suitable for direct connection of bars. Other connection possibilities for bars include vertical-connection adapters for edgewise bars and spreaders to increase the pole pitch to 95 mm. E46426A E54540 Bars E59254A Spreaders E54456 Cable lug adapters enable connection of one to four cables with crimped lugs (y 300 mm2). To ensure stability, spacers must be positioned between the terminal extensions. E46427A Cables with lugs A-116 E59253A E59255A Cable lug adapters E54540 Rear connection of withdrawable devices Spreaders Cables with lugs Cable lug adapters enable connection of one to four cables with crimped lugs (y 300 mm2). To ensure stability, spacers must be positioned between the terminal extensions. E46427A E54456 E59260A E59259A E59258A E59282A Withdrawable, rear-connection Compact NS630b to 1600 devices equipped with horizontal or vertical connectors may be directly connected to flat or edgewise bars, depending on the position of the connectors. Spreaders are available to increase the pole pitch to 95 mm. E46431A Bars E59262A E59261A Cable lug adapters A-117 Functions and characteristics Electrical and mechanical accessories Compact NS630b to 1600 (cont.) Insulation of live parts Mounted on fixed, front-connection devices, this shield insulates power-connection points, particularly when cables with lugs are used E59263A E45190 Connection shield Connection shield These barriers are flexible insulated partitions used to reinforce isolation of connection points in installations with busbars, whether insulated or not. Barriers are installed vertically between front or rear connection terminals. They are mandatory for voltages u 500 V for both fixed and withdrawable products and for L and LB types, whatever the voltage. E79056 Interphase barriers Interphase barriers for fixed device, front connection E79057 Compact NS equipped with connection shield E59264A Interphase barriers for fixed device, rear connection Interphase barriers for withdrawable device, rear connection Mounted on the chassis, the safety shutters automatically block access to the disconnecting contact cluster when the device is in the disconnected or test positions (degree of protection IP20). When the device is removed from its chassis, no live parts are accessible. The shutters can be padlocked (padlock not supplied) to: b prevent connection of the device b lock the shutters in the closed position. A-118 E59265A Safety shutters (standard) Safety shutters Connection of electrical auxiliaries Connections are made directly to the auxiliaries once the front has been removed. Wires exit the circuit breaker through a knock-out in the top. OF1 CAO2 OF2 OF3 rotary handle E59286A CAO1 CAF2 CAF1 E59283A Fixed devices SD MN or MX SDE COM OF1 OF2 OF3 MN ou or MX Withdrawable devices Auxiliary circuits are connected to terminal blocks located in the top part of the chassis. The auxiliary terminal block is made up of a fixed and moving part. The two parts are in contact when the device is in the test and connected positions. E59287A COM SDE E59284A Manually operated device CT1 CE1 CE2 CE3 CD1 CD2 E59285A Electrically operated device Withdrawable device A-119 Functions and characteristics Electrical and mechanical accessories 044314 Compact NS630b to 1600 (cont.) Indication contacts Contacts installed in the device Changeover contacts are used to remote circuit-breaker status information and can thus be used for indications, electrical locking, relaying, etc. They comply with the IEC 60947-5 international recommendation. OF, SD and SDE changeover contacts All the auxiliary contacts opposite are also available in "low-level" versions capable of switching very low loads (e.g. for the control of PLCs or electronic circuits). Functions b OF (ON/OFF) - indicates the position of the main circuit breaker contacts b SD (trip indication) - indicates that the circuit breaker has tripped due to: v an overload v a short-circuit v an earth-leakage fault. v operation of a voltage release v operation of the "push to trip" button v disconnection when the device is ON. Returns to de-energised state when the circuit breaker is reset. b SDE (fault indication) - indicates that the circuit breaker has tripped due to: v an overload v a short-circuit v an earth-leakage fault. Returns to de-energised state when the circuit breaker is reset. b CAF / CAO (early-make or early-break function) - indicates the position of the rotary handle. Used in particular for advanced opening of safety trip devices (early break) or to energise a control device prior to circuit-breaker closing (early make). Installation b OF, SD and SDE functions - a single type of contact provides all these different indication functions, depending on where it is inserted in the device. The contacts clip into slots behind the front cover of the circuit breaker b CAF / CAO function - the contact fits into the rotary-handle unit (direct or extended). Electrical characteristics of the OF/SD/SDE/CAF/CAO auxiliary contacts Contacts Rated thermal current (A) Minimum load Utilisation cat. (IEC 60947-5-1) Operational 24 V current (A) 48 V 110 V 220/240 V 250 V 380/440 V 480 V 660/690 V Standard Low level 6 100 mA at 24 V AC12 AC15 DC12 6 6 6 6 6 2.5 6 5 0.6 6 4 0.3 6 2 6 1.5 6 0.1 - 5 1 mA at 4 V AC12 AC15 5 3 5 3 5 2.5 5 2 5 5 1.5 5 1 - DC14 1 0.2 0.05 0.03 - DC12 5 2.5 0.6 0.3 - DC14 1 0.2 0.05 0.03 - 056456 Connected, disconnected, test position carriage switches A single type of changeover contact can be mounted optionally on the chassis to indicate, depending on the slot where it is installed: b the connected (CE) position b the disconnected (CD) position. This position is indicated when the required clearance for isolation of the power and auxiliary circuits is reached b the test (CT) position. In this position, the power circuits are disconnected and the auxiliary circuits are connected. Installation b contacts for the connected (CE), disconnected (CD) and test (CT) positions clip into the upper front section of the chassis. Electrical characteristics of the CE/CD/CT auxiliary contacts Carriage switches for connected (CE), disconnected (CD) and test (CT) positions A-120 Contacts Rated thermal current (A) Minimum load Utilisation cat. (IEC 60947-5-1) Operational 24 V current (A) 48 V 110 V 220/240 V 250 V 380/440 V 660/690 V Standard Low level 8 100 mA at 24 V AC12 AC15 DC12 8 6 2.5 8 6 2.5 8 5 0.8 8 4 0.3 8 3 6 0.1 - 5 2 mA at 15 V AC12 AC15 5 3 5 3 5 2.5 5 2 5 5 1.5 - DC14 1 0.2 0.05 0.03 - DC12 5 2.5 0.8 0.3 - DC14 1 0.2 0.05 0.03 - PB10078-32 M6C programmable contacts These contacts, used with the Micrologic P control units, may be programmed via the control unit keypad or via a supervisory station with the COM communication option. They require an external power supply module. They indicate: b the type of fault b instantaneous or delayed threshold overruns. They may be programmed: b with instantaneous return to the initial state b without return to the initial state b with return to the initial state following a delay. M6C programmable contacts: circuit-breaker external relay with six independent changeover contacts controlled from the circuit breaker via a three-wire connection. Characteristics Minimum load Breaking capacity (A) p.f.: 0.7 M6C V AC V DC 240 380 24 48 125 250 100 mA/24 V 5 3 1.8 1.5 0.4 0.15 DB101170 M6C: external 24 V DC power supply required (consumption 100 mA). E45159 Rotary handles There are two types of rotary handle: b direct rotary handle b extended rotary handle. There are two models: b standard with a black handle b VDE with a red handle and yellow front for machine-tool control. Direct rotary handle E45161 Compact NS with a direct rotary handle Degree of protection IP40, IK07. The direct rotary handle maintains: b visibility of and access to trip unit settings b suitability for isolation b indication of the three positions O (OFF), I (ON) and tripped b access to the "push to trip" button b circuit breaker locking capability in the OFF position by one to three padlocks, shackle diameter 5 to 8 mm (not supplied). It replaces the circuit-breaker front cover. Accessories transform the standard direct rotary handle for the following situations: b a higher degree of protection (IP43, IK07) b machine-tool control, complying with CNOMO E03.81.501, IP54, IK07. Extended rotary handle Compact NS with an extended rotary handle Degree of protection IP55, IK07. This handle makes it possible to operate circuit breakers installed at the back of switchboards, from the switchboard front. It maintains: b suitability for isolation b indication of the three positions O (OFF), I (ON) and tripped b access to trip unit settings, when the switchboard door is open b circuit breaker locking capability in the OFF position by one to three padlocks, shackle diameter 5 to 8 mm (not supplied). The door cannot be opened if the circuit breaker is ON or locked. The extended rotary handle is made up of: b a unit that replaces the front cover of the circuit breaker (secured by screws) b an assembly (handle and front plate) on the door that is always secured in the same position, whether the circuit breaker is installed vertically or horizontally b an extension shaft that must be adjusted to the distance. The min/max distance between the back of circuit breaker and door is 218/605 mm. A-121 Electrical and mechanical accessories Functions and characteristics Compact NS630b to 1600 (cont.) 056421 Remote tripping This function opens the circuit breaker via an electrical order. It is made up of: b a shunt release (2nd MX) b or an undervoltage release (MN) b or a delayed undervoltage release (MN + delay unit). These releases (2nd MX or MN) cannot be operated by the communication bus. The delay unit, installed outside the circuit breaker, may be disabled by an emergency OFF button to obtain instantaneous opening of the circuit breaker. opening order E46554A E46553A Wiring diagram for the remote-tripping function E59433A Manually operated circuit breakers may be equipped with an MX shunt release, an MN undervoltage release or a delayed undervoltage release (MN + delay unit). Electrically operated circuit breakers are equipped as standard with a remoteoperating mechanism to remotely open or close the circuit breaker. An MX shunt release or an MN undervoltage release (instantaneous or delayed) may be added. opening order delayed opening order MX voltage release 10 12 3 6 delay unit C2 D2 instantaneous opening order MN MN MX C1 D2 D1 D1 Voltage releases (2nd MX) When energised, the 2nd MX voltage release instantaneously opens the circuit breaker. A continuous supply of power to the 2nd MX locks the circuit breaker in the OFF position. Characteristics Power supply V AC 50/60 Hz V DC Operating threshold Permanent locking function Consumption (VA or W) Circuit-breaker response time at Un 24 - 48 - 100/130 - 200/250 - 277 - 380/480 12 - 24/30 - 48/60 - 100/130 - 200/250 0.7 to 1.1 Un 0.85 to 1.1 Un pick-up: 200 (200 ms) hold: 4.5 50 ms ±10 Instantaneous voltage releases (MN) The MN release instantaneously opens the circuit breaker when its supply voltage drops to a value between 35 % and 70 % of its rated voltage. If there is no supply on the release, it is impossible to close the circuit breaker, either manually or electrically. Any attempt to close the circuit breaker has no effect on the main contacts. Circuit-breaker closing is enabled again when the supply voltage of the release returns to 85 % of its rated value. Characteristics Power supply V AC 50/60 Hz V DC Operating opening threshold closing Consumption (VA or W) MN consumption with delay unit (VA or W) Circuit-breaker response time at Un 24 - 48 - 100/130 - 200/250 - 380/480 24/30 - 48/60 - 100/130 - 200/250 0.35 to 0.7 Un 0.85 Un pick-up: 200 (200 ms) hold: 4.5 pick-up: 400 (200 ms) hold: 4.5 90 ms ±5 MN delay units To eliminate circuit-breaker nuisance tripping during short voltage dips, operation of the MN release can be delayed. This function is achieved by adding an external delay unit in the MN voltage-release circuit. Two versions are available, adjustable and non-adjustable. Characteristics Power supply V AC 50-60 Hz /DC Operating threshold Consumption of delay unit alone (VA or W) Circuit-breaker response time at Un A-122 non-adjustable 100/130 - 200/250 adjustable 48/60 - 100/130 - 200/250 - 380/480 opening 0.35 to 0.7 Un closing 0.85 Un pick-up: 200 (200 ms) hold: 4.5 non-adjustable adjustable 0.25 s 0.5 s - 0.9 s - 1.5 s - 3 s Electrically operated circuit breakers are equipped as standard with a motor mechanism module. Two solutions are available for electrical operation: b a point-to-point solution b a bus solution with the COM communication option. Electrically operated circuit breaker The motor mechanism module is used to remotely open and close the circuit breaker. It is made up of a spring-charging motor equipped with an opening release and a closing release. An electrical operation function is generally combined with: b device ON/OFF indication (OF) b "fault-trip" indication (SDE). Motor mechanism module V AC 50/60 Hz V DC Operating threshold Consumption (VA or W) Motor overcurrent Charging time Operating frequency E45163 Power supply Electrical closing order The release remotely closes the circuit breaker if the spring mechanism is charged. Release electrical characteristics are identical to those of an MX release (see above), the operating threshold is from 0.85 to 1.1 Un and the circuit-breaker response time at Un is 60 ms ±10. The Compact NS electrical operation function can be used to implement a synchro-coupling system. Electrical opening order The release instantaneously opens the circuit breaker when energised. The supply can be impulse-type or maintained. Release electrical characteristics are identical to those of an MX release (see above). Electrically operated Compact NS circuit breaker Wiring diagram of a bus-type electrical operation solution Wiring diagram of a point-to-point electrical operation solution E59434A E59435A 48/60 - 100/130 - 200/240 - 277 - 380/415 24/30 - 48/60 - 100/125 - 200/250 0.85 to 1.1 Un 180 2 to 3 In for 0.1 second maximum 4 seconds maximum 3 cycles per minute opening order opening order closing order A4 A2 B4 closing order A4 fault A2 B4 motor mechanism module motor mechanism module A1 82 closed open 84 12 14 OF1 SDE A1 81 11 COM OF supervisor SDE In the event of simultaneous opening and closing orders, the mechanism discharges without any movement of the main contacts. In the event of maintained opening and closing orders, the standard electrical operation solution provides an anti-pumping function by blocking the main contacts in open position. A-123 Electrical and mechanical accessories Functions and characteristics E45194 Compact NS630b to 1600 (cont.) Locking on manually operated devices Toggle locked by removable padlocking device Locking in the OFF position guarantees isolation as per IEC 60947-2. Padlocking systems can receive up to three padlocks with shackle diameters ranging from 5 to 8 mm (padlocks not supplied). Control device Toggle Direct rotary handle E45159 Rotary handle locked by a keylock CNOMO direct rotary handle Extended rotary handle Function Means Required accessories lock in OFF position lock in OFF or ON position lock in b OFF position b OFF or ON position lock in b OFF position b OFF or ON position lock in OFF position, door opening prevented padlock padlock removable device fixed device padlock keylock padlock keylock padlock keylock locking device + keylock locking device + keylock keylock Locking in ON position does not prevent the device from tripping in the event of a fault or remote tripping order. Locking on electrically operated devices E59436A 1 1 I O push push ON OFF 3 2 3 4 5 4 6 7 8 5 reset of mechanical trip indicator OFF pushbutton OFF position locking ON pushbutton springs charged indication pushbutton locking contact position indication operation counter ed harg disc 2 O OFF 6 7 012 53 Pushbutton locking 056446 056447 8 Access to pushbuttons protected by transparent cover The transparent cover blocks access to the pushbuttons used to open and close the device. It is possible to independently lock the opening OFF button and the closing ON button. The pushbuttons may be locked using either: b three padlocks (not supplied) b lead seal b two screws. Pushbutton locking using a padlock 056448 056449 Device locking in the OFF position OFF position locking using a keylock and padlocks OFF position locking using padlocks A-124 The circuit breaker is locked in the OFF position by physically maintaining the opening pushbutton pressed down: b using padlocks in standard (one to three padlocks, not supplied) b using a keylock (supplied). Keys may be removed only when locking is effective (Profalux or Ronis type locks). The keylocks are available in any of the following configurations: b one keylock b one keylock mounted on the device + one identical keylock supplied separately for interlocking with another device. A locking kit (without lock) is available for installation of a keylock (Ronis, Profalux, Kirk or Castell). E59267A Chassis locking 3 4 5 1 6 7 8 9 1 2 3 4 5 6 7 mismatch protection door interlock racking interlock keylock locking padlock locking position indicator chassis front plate (accessible with cubicle door closed) 8 crank entry 9 reset button 10 crank storage 10 Disconnected position locking by padlocks 056417 Disconnected position locking 056451 056450 2 Mounted on the chassis and accessible with the door closed, these devices lock the circuit breaker in the disconnected position in two manners: b using padlocks (standard), up to three padlocks (not supplied) b using keylocks (optional), one or two different keylocks are available. Profalux and Ronis keylocks are available in different options: b one keylock b one keylock mounted on the device + one identical keylock supplied separately, using the same key, for interlocking with another device b one (or two) keylocks mounted on the device + one (or two) identical keylocks supplied separately, for interlocking with another device. A locking kit (without locks) is available for installation of one or two keylocks (Ronis, Profalux, Kirk or Castell). Disconnected position locking by keylocks Door interlock Connected, disconnected and test position locking The connected, disconnected and test positions are shown by an indicator. The racking crank blocks when the exact position is obtained. A release button is used to free it. On request, the disconnected position locking system may be modified to lock the circuit breaker in any of the three positions, connected, disconnected and test. Door interlock Mounted on the right or left-hand side of the chassis, this device inhibits opening of the cubicle door when the circuit breaker is in connected or test position. It the breaker is put in the connected position with the door open, the door may be closed without having to disconnect the circuit breaker. 056452 Racking interlock Racking interlock This device prevents insertion of the crank when the cubicle door is open (device cannot be connected). Mismatch protection 056453 Mismatch protection ensures that a circuit breaker is installed only in a chassis with compatible characteristics. It is made up of two parts (one on the chassis and one on the circuit breaker) offering twenty different combinations that the user may select. Mismatch protection A-125 Electrical and mechanical accessories Functions and characteristics 056463 Compact NS630b to 1600 (cont.) Auxiliary terminal shield Other accessories Auxiliary terminal shield (CB) Optional equipment mounted on the chassis, the shield prevents access to the terminal block of the electrical auxiliaries. Operation counter (CDM) 056464 Operation counter The operation counter sums the number of operating cycles and is visible on the front panel. It is compatible with electrically operated devices. Escutcheon (CDP) Optional equipment mounted on the door of the cubicle, the escutcheon increases the degree of protection to IP40. It is available in fixed and withdrawable versions. Transparent cover (CCP) for escutcheon E45184 Escutcheon Optional equipment mounted on the escutcheon, the cover is hinged and secured by a screw. It increases the degree of protection to IP54 and the degree of protection against mechanical impacts to IK10. It may be used for withdrawable devices only. Blanking plate (OP) for escutcheon E45187 Transparent cover E59987 Used with the escutcheon, this option closes off the door cutout of a cubicle not yet equipped with a device. It may be used with the escutcheon for both fixed and withdrawable devices. Blanking plate A-126 Electrical and mechanical accessories Functions and characteristics Compact NS1600b to 3200 (fixed version) OFF OFF OFF OFF A-127 Electrical and mechanical accessories Functions and characteristics Compact NS1600b to 3200 (cont.) E45178 Installation Fixed circuit breakers E59271A Compact NS1600b to 3200 circuit breakers should be installed vertically only. OFF OFF Fixed Compact NS Mounting on rails E59281A Connection Front connection NS3200 E59272A E59726A NS1600 to 2500 OFF OFF OFF OFF Bars E59273 E59275A Bars may be directly connected to the terminals of Compact NS1600b to 3200 circuit breakers. NS1600b to 2500 OFF OFF E59728A E59727A E59274A NS1600b to 2500 with connection for vertical-connection adapters or NS3200 OFF OFF A-128 OFF OFF 044314 Indication contacts Contacts installed in the device OF, SD and SDE changeover contacts All the auxiliary contacts opposite are also available in "low-level" versions capable of switching very low loads (e.g. for the control of PLCs or electronic circuits). Changeover contacts are used to remote circuit-breaker status information and can thus be used for indications, electrical locking, relaying, etc. They comply with the IEC 60947-5 international recommendation. Functions b OF (ON/OFF) - indicates the position of the main circuit breaker contacts b SD (trip indication) - indicates that the circuit breaker has tripped due to: v an overload v a short-circuit v an earth-leakage fault v operation of a voltage release v operation of the "push to trip" button Returns to de-energised state when the circuit breaker is reset. b SDE (fault indication) - indicates that the circuit breaker has tripped due to: v an overload v a short-circuit v an earth-leakage fault. Returns to de-energised state when the circuit breaker is reset. Installation b OF, SD and SDE functions - a single type of contact provides all these different indication functions, depending on the position where it is inserted in the device. The contacts clip into slots behind the front cover of the circuit breaker. Electrical characteristics of the OF/SD/SDE auxiliary contacts Contacts Rated thermal current (A) Minimum load Utilisation cat. (IEC 60947-5-1) Operational 24 V current (A) 48 V 110 V 220/240 V 250 V 380/440 V 480 V 660/690 V Standard Low level 6 100 mA at 24 V AC12 AC15 DC12 6 6 6 6 6 2.5 6 5 0.6 6 4 0.3 6 2 6 1.5 6 0.1 - 5 1 mA at 4 V AC12 AC15 5 3 5 3 5 2.5 5 2 5 5 1.5 5 1 - DC14 1 0.2 0.05 0.03 - DC12 5 2.5 0.6 0.3 - DC14 1 0.2 0.05 0.03 - A-129 Electrical and mechanical accessories Functions and characteristics Compact NS1600b to 3200 (cont.) 056421 Compact NS1600b to 3200 circuit breakers may be equipped with an MX shunt release, an MN undervoltage release or a delayed undervoltage release (MN + delay unit). Remote tripping This function opens the circuit breaker via an electrical order. It is made up of: b a shunt release (2nd MX) b or an undervoltage release (MN) b or a delayed undervoltage release (MN + delay unit). These releases (2nd MX or MN) cannot be operated by the communication bus. The delay unit, installed outside the circuit breaker, may be disabled by an emergency OFF button to obtain instantaneous opening of the circuit breaker. MX voltage release opening order E46554A E46553A E59433A Wiring diagram for the remote-tripping function opening order delayed opening order 10 12 3 6 delay unit C2 D2 instantaneous opening order MN MN MX C1 D2 D1 D1 Voltage releases (2nd MX) When energised, the 2nd MX voltage release instantaneously opens the circuit breaker. A continuous supply of power to the 2nd MX locks the circuit breaker in the OFF position. Characteristics Power supply V AC 50/60 Hz V DC Operating threshold Permanent locking function Consumption (VA or W) Circuit-breaker response time at Un 24 - 48 - 100/130 - 200/250 - 277 - 380/480 12 - 24/30 - 48/60 - 100/130 - 200/250 0.7 to 1.1 Un 0.85 to 1.1 Un pick-up: 200 (200 ms) hold: 4.5 50 ms ±10 Instantaneous voltage releases (MN) The MN release instantaneously opens the circuit breaker when its supply voltage drops to a value between 35 % and 70 % of its rated voltage. If there is no supply on the release, it is impossible to close the circuit breaker, either manually or electrically. Any attempt to close the circuit breaker has no effect on the main contacts. Circuit-breaker closing is enabled again when the supply voltage of the release returns to 85 % of its rated value. Characteristics Power supply V AC 50/60 Hz V DC Operating opening threshold closing Consumption (VA or W) MN consumption with delay unit (VA or W) Circuit-breaker response time at Un 24 - 48 - 100/130 - 200/250 - 380/480 24/30 - 48/60 - 100/130 - 200/250 0.35 to 0.7 Un 0.85 Un pick-up: 200 (200 ms) hold: 4.5 pick-up: 400 (200 ms) hold: 4.5 90 ms ±5 MN delay units To eliminate circuit-breaker nuisance tripping during short voltage dips, operation of the MN release can be delayed. This function is achieved by adding an external delay unit in the MN voltage-release circuit. Two versions are available, adjustable and non-adjustable. Characteristics Power supply V AC 50-60 Hz /DC Operating threshold Consumption of delay unit alone (VA or W) Circuit-breaker response time at Un A-130 non-adjustable 100/130 - 200/250 adjustable 48/60 - 100/130 - 200/250 - 380/480 opening 0.35 to 0.7 Un closing 0.85 Un pick-up: 200 (200 ms) hold: 4.5 non-adjustable adjustable 0.25 s 0.5 s - 0.9 s - 1.5 s - 3 s 62191 Device locking Locking in the OFF position guarantees isolation as per IEC 60947-2. Padlocking systems can receive up to three padlocks with shackle diameters ranging from 5 to 8 mm (padlocks not supplied). Control device Toggle Function Means Required accessories lock in OFF position lock in OFF or ON position padlock padlock removable device fixed device Interphase barriers These barriers are flexible insulated partitions used to reinforce isolation of connection points in installations with busbars, whether insulated or not. Barriers are installed vertically between front connection terminals. 62190 Compact NS with toggle locked using a fixed device and padlocks Escutcheon (CDP) Optional equipment mounted on the door of the cubicle, the escutcheon increases the degree of protection to IP40. E79056 Compact NS with toggle locked using a removable device and padlocks E94383 Interphase barriers Escutcheon A-131 Test equipment Functions and characteristics Mini test kit 052172 047035 Compact NS100 to 630 test equipment for STR electronic trip units The mini test kit is a portable unit requiring no external power supply, used to check operation of the electronic trip unit and circuit-breaker tripping. It connects to the test connector on the front of the circuit breaker. Required power source: five 9 V alkaline batteries (not supplied). Portable test kit Mini test kit Portable test kit The portable test kit is used to check all aspects of the protection functions: b long time protection b short time protection b instantaneous protection b earth-fault protection. Required power source: 110 or 220 V AC, 50/60 Hz. Compact NS630b to 3200 test equipment for Micrologic control units Mini test kit 056466 The autonomous hand-held mini test kit may be used to: b check operation of the control unit and the tripping and pole-opening system by sending a signal simulating a short-circuit b supply power to the control units for settings via the keypad when the circuitbreaker is open (Micrologic P control units). Required power source: standard LR6-AA battery. Portable test kit The portable test kit is may be used to check: b the mechanical operation of the circuit breaker b the electrical continuity of the connection between the circuit breaker and the control unit b operation of the control unit: v display of settings v operating tests on the ASIC electronic component v automatic and manual tests on protection functions v test on the zone-selective interlocking (ZSI) function v inhibition of the earth-fault protection v inhibition of the thermal memory. Note These test kits are identical for all Compact NS630b to 3200 circuit breakers and all Masterpact NT and NW circuit breakers. Required power source: 110 or 220 V AC, 50/60 Hz. Portable test kit A-132 Display modules 057454 Perfectly integrated in the Compact and Masterpact ranges, Display modules are designed for use with Micrologic control units to provide instant and highly intuitive access to all the information provided by the circuit breakers, including device status, current, voltage and power values, etc. DMB300 and DMC300 display modules use the power and communications capabilities of the Micrologic control units to centralise the display of electrical values, status conditions and alarms of one or more Compact or Compact circuit breakers. The mounting and cabling system for the display modules ensures fast, easy and reliable installation. Start-up is immediate with no configuration or programming required. Display modules are high-performance devices combining: b simple and easy-to-read dials b powerful and accurate digital processing. Their small size and extensive communications capabilities make for easy and flexible installation and operation. Display modules DMB300 DMC300 Associated circuit breakers Type Number Compact or Masterpact equipped with Micrologic control units 1 to 4 1 to 16 Display DMB300 display module: basic and harmonic measurements Screen type Screen size Entry Black and white 240 x 64 pixels 5 buttons Colour, touch screen 5“, 320 x 240 pixels Touch screen Information displayed E79078 Currents (per phase) Currents I1, I2, I3, IN Maximum current Earth-fault and earth-leakage currents Demand current Maximum demand current DMC300 display module: measurements, harmonic analysis, diagnosis A A A P P P P P A A A P P P P P Voltages Phase-to-phase voltages (U1-2, U2-3, U3-1) Minimum/maximum phase-to-phase voltages Phase-to-neutral voltages (V1-N, V2-N, V3-N) Minimum/maximum phase-to-neutral voltages Frequency Voltage unbalance (% per phase) P P P P P P P P Power Active (P), reactive (Q) and apparent (S) power Power factor and cos Maximum power (P, Q, S) Demand power (P, Q, S) Maximum demand power (P, Q, S) P P P P P P P P P P Metering Active, reactive and apparent energy P P P On-line help On-line help is available for each type of information supplied by the module Circuit-breaker diagnostics Identification of control units Reading of protections Circuit-breaker status Type of trip Current alarms Maintenance indicator Installation diagnosis Indication of faulty devices Fault log A A A A P P P P P A A A A P P P P P P A A P P Installation and start-up Mounting Connection Mounted through door, without tools, using 6 spring-clips supplied with the mod. Prefabricated wiring systems Associated Micrologic control unit A = Micrologic A P = Micrologic P A-133 Connection of DMB300 display module Wiring system The wiring system is designed for low-voltage power switchboards. Installation requires no tools or special skills. The prefabricated wiring ensures both data transmission (Modbus protocol) and 24V DC power distribution for the display module and the communications modules on the Micrologic control units. 24 V DC power E59178 Display modules Functions and characteristics 1 2 E59081 ON ON ON n° 4n° 4 4 ON n° n° 3n°° 3 n° 4 n° 2n° 2 n° 3 n° 3 n° 1n° 1 n° 2 n° 2 OUTOUT n° 1 IN IN T IN ON OU 1 3 Reset push push 70 NX 32 ON Ir Ig Isd I ∆n Ii Ap reset Icu (kA) 100 100 85 Icw 85kA/1s cat.B ed Ics = discharg CDM 303: Connection cable between display module and junction block H2 Ue (V) 220/440 525 690 OFF Micrologic 100% Icu 50/60Hz O OFF 947-2 AS NEMA IEC UNE EN 60947-2 BS CEI UTE 012 VDE 53 com DMB300 Digipact volets shutters Test 1 2 I 3 U P ? select E59180A 4 NW 1251 2 H1 Uimp 12kV Ui 1000V 8kV Uimp Icu (kA) 100 85 Ue (V) 220/240 480/690 70 Micrologic Ir Ig Isd I ∆n Ii Ap reset I ON OOFF push push discharged O OFF ON Ics = UTE 012 100% Icu 947-2 CEI VDE BS IEC UNE NEMA 53 IN NW 1251 OUT n° 1 n° 2 n° 3 n° 4 ON H1 Uimp 12kV Ui 1000V 8kV Uimp Icu (kA) 100 85 Ue (V) 220/240 480/690 70 Micrologic Ir Ig Isd I ∆n Ii Ap reset I ON OOFF push push discharged O OFF Ics = IEC 100% 947-2 UTE VDE CJB 306 junction block Icu BS CEI UNE NEMA 53 E59179 012 Compact circuit breakers equipped with Micrologic control units and the Modbus eco COM option CCP 303: Connection cable between Masterpact or Compact and junction block Connection of DMC300 display module Maximum distance between module and circuit breaker: 1200 m 5 3 E59082 E59176A 4 2 2 4 2 1 H1 1251 12kV NW Uimp H1 1251 12kV NW Uimp Ui 1000V 8kV Uimp Ui 1000V 8kV Uimp Icu (kA) Ue (V) 220/240 480/690 70 Ir 70 Micrologic Ig Isd I ∆n Ii Ap reset Ir I ON OOFF Ig Isd I ∆n Ii Ap reset I ON push OOFF push push push discharged discharged O OFF O OFF Ics = 100% Icu Ig Isd I ∆n Ii Ap NX 32 ON d discharge Icu (kA) 100 100 85 Icw 85kA/1s cat.B Ics = 012 H2 Ue (V) 220/440 525 690 OFF reset 100% Icu 50/60Hz O OFF 947-2 AS NEMA IEC UNE EN 60947-2 BS CEI 3 UTE VDE Ics = 012 53 3 NW 1251 H1 Uimp Ui 1000V 8kV Uimp Ir NW 12kV Ap reset Ir I ON OOFF Ig Isd I ∆n Ii Ap I ON OOFF discharged O OFF Ics = IEC 100% push push ON Ap ed discharg reset O OFF NX 32 IEC 100% Icu 947-2 UTE VDE 012 BS CEI UNE NEMA 53 5 Icu (kA) 100 100 85 100% Icu NW 50/60Hz 1251 Ui 1000V 8kV Uimp 947-2 AS NEMA IEC UNE EN 60947-2 BS CEI UTE UNE NEMA Icw 85kA/1s cat.B Ics = Ics = BS CEI 53 H2 Ue (V) 220/440 525 690 OFF 70 Icu 947-2 UTE VDE 012 push push discharged Ig Isd I ∆n Ii 12kV Icu (kA) 100 85 reset push push Reset H1 Uimp Ue (V) 220/240 480/690 70 CCR 301: Roll of RS 485 cable (2 RS 485 wires + 2 power supply wires) Micrologic Ig Isd I ∆n Ii O OFF Ir 1251 Ui 1000V 8kV Uimp Icu (kA) 100 85 Ue (V) 220/240 480/690 70 Micrologic Micrologic 100% UTE VDE 53 3 E59177 push push 70 Ir Icu NEMA 947-2 IEC BS CEI UNE NEMA 947-2 IEC BS CEI UNE UTE VDE Reset Micrologic Icu (kA) 100 85 Ue (V) 220/240 480/690 100 85 Micrologic 70 H1 Uimp Ig Isd I ∆n Ii 1251 H1 Uimp Ui 1000V 8kV Uimp 12kV Icu (kA) 100 85 Ue (V) 220/240 480/690 70 Micrologic Micrologic Ir NW 12kV Icu (kA) 100 85 Ue (V) 220/240 480/690 VDE Ap reset Ir I ON OOFF Ig Isd I ∆n Ii Ap reset I ON push OOFF push discharged O OFF Ics = IEC 100% 947-2 UTE VDE 012 push push discharged O OFF Icu BS CEI Ics = UNE NEMA 53 IEC 100% 947-2 UTE VDE 012 Icu BS CEI UNE NEMA 53 CSD 309: SubD 9-pin connector for colour-coded connection of wires to screw terminals Compact circuit breakers equipped with Micrologic control units and the Modbus eco COM option A-134