MWS
D ES C R IPTION
MWS, Modular Wiring Systems, provide low cost installation of branch
circuit wiring for lighting and power. Using modular components
that plug together, MWS can be installed in a fraction of the time of
hardwiring. Plus, MWS offers the advantage of relocating fixtures and
outlets in future renovations.
®
Type
Catalog #
Project
Date
Comments
The MWS Drop Cable (DC) supplies power to out of system units that are
wall mounted or ceiling mounted.
Prepared by
MWS Drop cables may be plugged into the last fixture cable (FC) or from
a Splitter (SP) anywhere within the system.
DES IGN FEA TUR ES
• UL Listed under Standard 183 for
make or break under load.
• Copper conductors are THHN
insulated wire rated 90°C.
• Meets requirements of Article 604
of the National Electrical Code.
• Galvanized steel exterior with
integral keying for voltage and
amperage.
• MWS components assembled
with 12 AWG/10 AWG conductors
rated at 20 amperes with full size
ground wire.
• Cable end supplied with 1/2"
connector with locknut and 6" prestripped leads.
• DC cable allows you to easily
supply power to other system units
such as j-boxes, receptacles or
fixtures.
• Valox 365 constructed contact
housings are approved for
environmental air plenums.
DC
DIMENS IONA L D A TA
DROP CABLE
SYSTEM VIEW (not to scale)
5/8"
[16mm]
Side
Drop Cable
Extender Cable
1-7/8"
[47mm]
Splitter or
Circuit T
Modular Wiring System
Junction Box
or any Out of
System Unit
supplied by
others.
Extender Cable
Drop Cable (DC)
Supplies power to out of system units. (Fixtures, J-boxes, etc.).
4-3/8"
[112mm]
Top
Typical MWS Wiring System Application shown utilizing Drop
Cable (DC).
Consult MWS Installation, Application and Specification
Manual for additional comprehensive system information.
OR D ER ING INFOR M AT I O N
S A M P L E N U M B E R : 2 7 D C 1 2 /2 G 1 1
MWS AUTOCAD DRAFTING
MWS offers AutoCAD drafting to layout
MWS, providing the contractor with
additional benefits.
DC
Component
DC=DropCable
Conductors and Size
10/2G=#10, 2 Conductors Plus Ground
10/3G=#10, 3 Conductors Plus Ground
10/4G=#10, 4 Conductors Plus Ground
12/2G=#12, 2 Conductors Plus Ground
12/3G=#12, 3 Conductors Plus Ground
12/4G=#12, 4 Conductors Plus Ground
Cable Length (Feet)
05=5'
09=9'
11=11'
15=15'
Options
2N=2 Neutral (1)
MWS design layout time is reduced.
Bills of material are computer-generated
guaranteeing accuracy.
MWS drawing symbols and details
standardized.
Layouts are available on CD or e-mail.
To utilize this service and for additional
information, contact the MWS Sales
Department (888) 487-4887.
NOTES: (1)12/4G and 10/4G only.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative
for availability and ordering information.
SH IP P ING D A T A
Install dust covers on unused open ends.
Scale is exaggerated on fixtures and
MWS system applications.
Specifications and
dimensions subject to
change without notice.
YS
ER
TEM
S
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
All electrical boxes, conduit, connections
and switches by others.
C
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
UnitStandard
Wt.Qty./Carton
2.0 lbs.
12
3.0 lbs.
9
3.5 lbs.
8
S
Cable
Length
5'
9'
11'
D
Voltage
12=120V
20=208V
24=240V
27=277V
34=347V
48=480V
TIFIE
ADF031851